Solid State Remote Power Controller E

Similar documents
Magnetic and Hydraulic-Magnetic Circuit Breaker

Power distribution systems - accessories

Power distribution systems - accessories

Thermal-Magnetic Circuit Breaker 4220-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Solid State Remote Power Controller E /627

Thermal-Magnetic Circuit Breaker 2216-S

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Module 18plus. Description. 18plus

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Power distribution system SVS16-PB

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Electronic Overcurrent Protector REF16-S

VersaPoint I/O Module

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

93 SERIES. Timed socket for 34 series 93.68/93.69

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV

Section 4 Ground-Fault Protection Devices

1.5 Solid State Relays

Transistor drive 2c/4c 5A slim power relays

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

VersaMax IP I/O Module

Miniature Circuit Breakers for Railway Applications

Faults on the system Proximity switch connection technology:

Module no: LabelId: Operator:Phoenix 14:20:45, Mittwoch, 1. März 2000

CROWN LINE Power Bus Bar Distribution System

Zelio Control-modular measurement and control relays 1

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

RUC industrial relays of small dimensions

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

RSTI-EP Slice I/O. Digital Output Module

Miniature Circuit-Breaker IEC Series 8562

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Switching and controlling in the switch cabinet

Time Delay Values (E-Series)

PLC-RSC- 24DC/21 Order No.:

Model Number Structure

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

1492-SP Supplementary Protectors

Connecting cables for valves, plug pattern ZC, metric screw Type codes

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Classification Enclosure rating Input voltage Type of

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

PSR DC/ESP4/2X1/1X2

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Residual Current Devices drcm Digital

MasterINTERFACE 39 Series - Relay interface modules

Jtec 10kA Miniature Circuit Breaker

Temperature Switches

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Allen-Bradley 1492-RCDA4A40

Model Number Structure

ESS20 Electronic Circuit Breaker

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

LED Driver DC-String

Micro Contactor MA Series

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

fine-stranded solid V A mm mm V/8 kv/3 32 No AWG 600 V 30/35 No AWG 600 V 40 6 mm 9 mm aüigotucf+qkw h

8 24 V DC, 8 24 V DC,

SSR - Supplies - Relays

SITOP in the SIMATIC Design

Introduction Circuit Protection

Cube67 - Modular I/O station

ALLEN BRADLEY RELAY Bulletin 700-HF

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

LED Driver DC-String

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

Circuit Breakers Type CTI 25M, CTI 45MB

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

IELR Rail-Mount Series Magnetic Circuit Protectors

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

RM4JA01F current measurement relay RM4-J - range ma V AC

Operating Instructions Electronic Circuit Protector ESX10-TC-DC 12 V

LED Driver Linear / area dimming

Transcription:

Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient or where no protection against overload and short circuit or wire breakage monitoring of connected loads is provided. The use of a costly, high-capacity card becomes superfluous when only one or two powerful s are necessary. Using the SSRPC in combination with the module plus creates a new, very flexible system capable of being subsequently changed or extended. Busbars, pre-wired signal contacts and spring-loaded terminals reduce installation times considerably (see accessories). Typical applications Automation - interface module providing inexpensive power amplification at PLC s - optimum protection of individual loads by monitoring the load circuit Protection and control of - motors - solenoids - lamps Features Optimum load protection. Available in current ratings of.5 A; A; A; 4 A; 5 A. No derating required over entire temperature range! Fast short-circuit limitation and disconnection Time/current dependent overload disconnection (simulating thermal-magnetic CBE trip curve) Remote control Fault indication: LED and signal for overload/short-circuit signalisation, and wire break indication in the OFF condition (version -) and in the OFF and ON condition (version - and -) Fault storage: version - and - Physically isolated fault indication Compact plug-in type Plug-in design for use with power distribution system module plus Integral pre-wiring of common supply and signal contacts Ordering information Type No. E-48 SSRPC for PLC s wire break indication in OFF condition (standard) permanent wire break indication permanent wire break indication and fault storage 3 without wire break indication Voltage rating DC4 V (standard) Current ratings.5 A. A. A 4. A 5. A E-48 - DC4 V. A ordering example Technical data (T ambient = 5 C; at U N ) Load circuit Voltage rating (8...36 V) Current rating I N.5 A; A; A; 4 A; 5 A (other ratings to special order) Closed-circuit current I Contr typically.3 ma Min. load current -/-: wire break indication in OFF condition Optional: wire break indication in OFF and ON condition wire break ind. in OFF cond. R load typically kω wire break ind. in ON cond. I load < typ. 3 ma (.5/ A unit) I load < typ. ma (/4/5 A unit) Voltage drop U DSmax.5 V;.3 V;. V;. V;.3 V Switch-on/switch-off time t on /t off typ. 3 μs/ μs with resistive load Overload disconnection approx..5 (±.3) x I N after approx. ms Short-circuit current max. 5 A (with.5 A and A (self-limiting) current ratings) max. 5 A (with A/4 A/5 A current ratings) Short-circuit disconnection < μs Control input Control level between and Voltage rating Voltage controlled input U E DC V < low level < 5 V DC 8.5 V < high level < 36 V Input current I E... ma (8.5...36 V) Max. switching frequency f max khz Reset time after short-circuit/ overload disconnection ms Fault indication F contact max. switching voltage DC V AC 5 V max. interrupting capacity DC 3 W AC 6 W limiting continuous current A General data Temperature range C...6 C Insulation voltage DC V > MΩ (IEC 6664/VDE ) Mass 8 g Preferred types Preferred types Standard current ratings (A).5 4 5 E-48--DC4V- x x x x x E-48--DC4V- x x x x x 3/4-9

Technical description Connection diagram At the correct input voltage (> 8.5 V), the SSRPC will switch on a power transistor to connect the load to the plus pole of the load circuit supply ( ). The transistor will switch off when - the control voltage (U E ) is removed - there is a short-circuit/overload in the load circuit. Status indication is provided by two LEDs (red and yellow). Simulated thermal-magnetic overload protection occurs at approx..5 times rated current. See time/current characteristic curves. The SSRPC is fitted with blade terminals D 4644-A6.3-.8 and is suitable for plug-in mounting with various E-T-A sockets or module plus (see Accessories). Control circuit ON condition: If a voltage higher than 8.5 V is applied to the input terminals (I N against ), the control current (from the PLC) will flow through the opto coupler. The transistor will be conductive, status indication by yellow LED. OFF condition: A control voltage lower than 5 V will switch the transistor off. fault indication circuit F 4 6 yellow control and monitoring electronics red 5 LE Load circuit The load circuit switches depending on the control signal ( or ). It is electronically monitored for faults. In the event of a short-circuit the circuit is disconnected after max. μs whilst upon inadmissible overload it is disconnected according to the time/current curves shown. Typical time/current characteristics (T A = 5 C).5 A and A Fault indication F The fault indication circuit is physically isolated from the load and control circuits via a. In the OFF condition, this circuit (with closed contact) will provide wire break indication, with the transistor being open. The versions with fault storage () store the fault signal until the control voltage is re-applied. Visual fault indication by red LED. Trip time in ms Dimensions current limitation. I N 3 I (A) 66.6 56. A and 4 A 4 6 3 5.5.453.9 Trip time in ms This is a metric design and millimeter dimensions take precedence ( mm ) inch current limitation. I N 4 6 8 I (A) - 3/4

Functional diagrams Functional diagram wire break indication E-48-x wire breakage monitoring only in OFF condition E-48-x wire breakage monitoring in ON and OFF condition wire break wire break Functional diagram overload /short-circuit indication E-48-x without fault storage E-48-x with fault storage overload / short-circuit overload / short-circuit = input set / = switched through LED lights 3/4 -

R Connection diagram Wiring diagram Solid State Remote Power Controller E-48- with Module plus main circuit plus power supply PLC power supply for PLC for load I / O signalisation circuit... control circuit busbar fitted Separate power supply for load, PLC I/O and signal loop power supply Chassis earth connection directly between the two power supplies! LE power supply for PLC alternatively 3 PLC I/O Out In - 3 LE 3 LE 3 LE 3 4 >i jumper >i >i >i 4 4 4 4 load load load load n module plus SSRPC E-48- main circuit minus Caution: If there is no firm chassis earth connection when using several separate power supplies, the connected fault indication loop may lead to intermittent operation of the SSRPC and resultant operational hazards. Wiring diagram Accessories Common power supply for load, PLC I/O and signal loop common power supply PLC I/O Out In - Module plus For technical data see section Power Distribution Systems slot for fitting labels from Phoenix, Weidmüller, Wieland 3 LE >i 4 4.85 4.5 66.6.6 4 6 3 5 plus 5.4 load 63.48 slot for busbar 5 4.53 G-profile EN 35-G3 symmetrical rail EN -35x.5 6 5 5.36.984.984 max. 38 max.. 4 right-side terminal block Line Line 4 left-side terminal block module - 3/4

.3.55.9.63.8.335.38.5.9.6.5.9.6.68 Accessories for Single mounting sockets (with adapter) (up to 6 A max. load) -P-Si -P-Si-5 -P-Si -P-Si-5 (retaining clip Y 3 58 available on request) polarized blade terminal D 4644-A6.3-.8 (QC.) slot for fitting labels from Phoenix, Weidmüller 6.3.48 -P blade terminal D 4644 part C profile (xa.8-.8) (QC x.).8. -P retaining clip -way mounting socket 6-way mounting socket 3-P-Si 63-P-Si (retaining clip Y 3 58 3 available on request).4.9 64 4.4.3 5.4.4.9 64 polarized blade terminals D 4644-A6.3-.8 (QC.).5 6.5.49.46 5.4..84 6.8 6 x 6.8 = 4.8 6 x.68 =.6.8 retaining clip 8.5 5.8 6.5.56. 3 8 3.5 polarization recess (k) 4 (i) depth mm ( in.) 33.3.4 5 4.3.5.49 symmetrical rail EN -35x.5 adapter X49 3 (k) 4 (i) 45.8 G-profile EN 35-G3.5.49 5.984 polarized recess.5.49.9 5.95 4.4.3 3.5 6.36.9 max. 3 max..8 Connector bus links -P X 588 /.5 mmm, (AWG 6), brown (up to 3 A max. load) X 588 /.5 mm, (AWG 4), black (up to A max. load) X 588 3/.5 mm, (AWG 4), red (up to A max. load) X 588 4/.5 mm, (AWG 4), blau (up to A max. load) Busbar (-way) (supplied as a complete package) for type socket (for max. A continuous load), more positions available on request X 5 with terminal X 5 without terminal ~ ~.6 quick-connect tabs 6.3 (.) D 464 tinned brass, insulated Phoenix terminal AKG 35 max.cross section 35 mm (AWG ).6 Insulating sleeving for busbar (-way) Y 33 84 9.354 5.4 5.3 4.9.669.8.4 54.8 6.9 cylinder head screw M4x4 ISO nickel plated.9 M4 washer A 4.3 D 5 nickel plated female connector Cu rail, tin-plated pressure-relief joint (. mm (.43 in.) thick constriction) mounting clips Y 3 4 ( pcs needed per unit).9.5 8.35.39.5..5.49.3.8 M4.5.9.95 Installation drawing with mounting clips Y 3 4 6.4.38.9 6.5.6.8 8.5.335.9 3/4-3

- 4 3/4