Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

Similar documents
James R Halama, PhD Loyola University Medical Center

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Philips SPECT/CT Systems

Fits you like no other

Fits you like no other

Dosimetry and Medical Radiation Physics section Division of Human Health. Quality Controls in Nuclear Medicine. IAEA-NMQC Toolkit

ISO ISO ISO OHSAS ISO

Introduction to Positron Emission Tomography

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Introduction to Emission Tomography

Symbia E and S System Specifications Answers for life.

3/19/2013. Outline. Objective. SPECT System Description. Calibration of an MR-Compatible, CZT Detector Based Stationary Small Animal SPECT system

Symbia T Series System Specifications Answers for life.

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Quantitative capabilities of four state-of-the-art SPECT-CT cameras

Micro-CT Methodology Hasan Alsaid, PhD

Continuation Format Page

8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial

연구용유방초음파질관리 원광대학병원김혜원

Medical Imaging BMEN Spring 2016

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

BME I5000: Biomedical Imaging

S. Guru Prasad, Ph.D., DABR

Quality control phantoms and protocol for a tomography system

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

AAPM Standard of Practice: CT Protocol Review Physicist

Corso di laurea in Fisica A.A Fisica Medica 4 TC

SPECT/CT Basics, Technology Updates, Quality Assurance, and Applications

Technical aspects of SPECT and SPECT-CT. John Buscombe

ACMP 25th Annual Meeting

Ch. 4 Physical Principles of CT

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Small Angle Gamma Ray Scatter: What Is The Impact On Image Quality

Emission Computed Tomography Notes

Performance Evaluation of the Philips Gemini PET/CT System

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Introduction to Biomedical Imaging

Mediso AnyScan. Single-Head and Dual-Head SPECT

Positron. MillenniumVG. Emission Tomography Imaging with the. GE Medical Systems

Educational Objectives SPECT/CT: Basics, Quality Assurance, and Clinical Applications

Master of Science Thesis. Activity quantification of planar gamma camera images

CT vs. VolumeScope: image quality and dose comparison

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Mediso AnyScan S Single-Head and Dual-Head SPECT

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

Computed Tomography Imaging: CT Protocol Management. Caveat 8/3/2017

GPU implementation for rapid iterative image reconstruction algorithm

Computer-Tomography II: Image reconstruction and applications

INTERNATIONAL STANDARD

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

If it matters to you, it matters to us

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

BEIJING HAMAMATSU PHOTON TECHNIQUES INC. Photon is our business BHP6602 Smart γ Camera Special NM Device for Details

Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Computer-Tomography I: Principles, History, Technology

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

3-D PET Scatter Correction

Fast Timing and TOF in PET Medical Imaging

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy

MEDICAL IMAGING 2nd Part Computed Tomography

DUE to beam polychromacity in CT and the energy dependence

Preparing for Part 2 of the ABR Diagnostic Physics Exam

V/Q Imaging Protocols

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

Constructing System Matrices for SPECT Simulations and Reconstructions

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3T MRI. Floris Jansen, GE Healthcare July, 2015

Lucy Phantom MR Grid Evaluation

Iterative SPECT reconstruction with 3D detector response

Quantitative imaging for clinical dosimetry

Inveon User Notes. Inveon Scanners and Inveon Acquisition Workplace 2.0

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

UNIVERSITY OF SOUTHAMPTON

QIBA PET Amyloid BC March 11, Agenda

A Comparison of the Uniformity Requirements for SPECT Image Reconstruction Using FBP and OSEM Techniques

Scaling Calibration in the ATRACT Algorithm

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Medical Image Processing in Nuclear Medicine. Andrew Todd-Pokropek University College London INSERM U494 Paris. Aims and Objectives

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Performance Evaluation of radionuclide imaging systems

Reconstruction from Projections

Image Acquisition Systems

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Transcription:

James R Halama, PhD Loyola University Medical Center Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program Learning Objectives 1. Be familiar with recommendations for acceptance and annual physics tests of gamma cameras for planar and SPECT imaging. 2. Be familiar with the tests of a SPECT/CT system that include the CT images for SPECT reconstructions and image registration. 3. Become knowledgeable of items to be included in test reports including CT dosimetry and display monitor measurements. 1

Introduction This presentation is based on the recommendations of the TG177 Report in process of approval. Compiled by Nuclear Medicine experts including James R. Halama, Daryl Graham, Beth A. Harkness, S. Cheenu Kappadath, Mark T. Madsen, Richard J. Massoth, James A. Patton, Sharon L. White, Lawrence E. Williams, and Wesley W. Wooten. Specifies performance tests to be made on gamma cameras, SPECT and hybrid SPECT/CT systems for acceptance testing, annual physics surveys. A manual detailing the performance test procedures under widely varying conditions Primary reference is Performance measurements of gamma cameras: National Electrical Manufacturers Association (NEMA) Standards Publication, NU 1-2012 TG177 Report Details the performance test procedures under widely varying conditions. Described for acceptance and annual physics surveys Refers to IAEA Quality Control Atlas for Scintillation Camera Systems International Atomic for example test images Preparatory Steps for Successful Testing Identify types of exams performed planar, SPECT, and SPECT/CT Identify the radioisotopes used and corresponding collimators System calibrations Test equipment needed Locate manufacturer manuals 2

Radioisotopes to Test 99m Tc 57 Co needed for extrinsic tests At least one other radionuclide from the following: 201 Tl, 123 I, 67 Ga, 131 I, and 111 In. Choice based on clinical use An additional radionuclide is not needed if only 99m Tc is used Detector & System Calibrations Completed prior to testing Uniformity for 99m Tc and other radionuclides Most new systems have a uniformity calibration for 99m Tc only. The calibration is used for all other radioisotopes and energy windows selected Uniformity calibration for 57 Co is not routinely performed Center-of-rotation and multi-head alignment for SPECT SPECT/CT alignment Manufacturer Manuals Describe procedures for detector calibrations Provide performance specifications Describe QA procedures: What calibrations are performed by the user and frequency Routine tests and test frequency All must be included and documented in camera QA protocol 3

Test materials and Equipment Sites should provide: Radioisotopes to be used and dose calibrator (required) 57 Co Sheet source for extrinsic measurements Syringes and vials Quadrant bar-phantom of appropriate dimensions SPECT Phantom Physicist should provide: Capillary tubes for line sources Flask or dish to be used for sensitivity measurements Attenuating Cu plates for count rate characteristic measurements Photometer Outline of Tests Physical Inspections Planar Imaging SPECT Imaging Hybrid SPECT/CT Physical Inspection & Shielding Check condition of camera system Identify and note condition of collimators in clinical use Assess detector shielding qualitatively Acceptance test - use 1 mci 99m Tc in syringe and move source slowly (top and sides) while observing count rate Annual survey visually examine for possible damage to shielding Assess adequate room and operator shielding at acceptance testing, particularly for SPECT/CT. Note assessment in report. 4

Monitors Used for Image Processing Test monitors in the camera room that a technologist uses to review and process images measured annually Display SMPTE or TG18QC test pattern using processing display software or through the operating system Identify the 5% and 95% luminance patches Measure maximum and minimum luminance Measure luminance uniformity Note spatial resolution and linearity of bar pattern patches Monitors Used for Image Interpretation Evaluate monitors located in the vicinity of the gamma camera; evaluated annually May be evaluated by another physicist or other service. Note date of evaluation and test results Display requirements of monitors for NM not published. TG177 report recommends maximum luminance > 120 cd/m 2, minimum < 2 cd/m 2, and nonuniformity <20% Gamma Camera Planar Tests Flood-Field Uniformity Spatial resolution & linearity Energy resolution Sensitivity Count rate characteristics Multiple-window spatial registration 5

Intrinsic Flood-Field Uniformity Measurement of uniformity without collimator and point source. Done for each detector UFOV mask may be absent so long as performance criteria are met Assess visually, and quantitatively using NEMA IU & DU definitions Acceptance testing 99m Tc and at least one other radionuclide, unless 99m Tc is only used isotope Annual survey 99m Tc and optionally one other radionuclide Measurement Notes: Point source of spherical volume < 0.3 ml Position directly over detector at a distance of at least 4*UFOV. Shorter distance may need additional software correction Adjust activity to achieve 20-40 Kcps How many counts? Depends on detector size and scales by area 30 million for large FOV detectors 10 million if uniformity criteria can be met Note: count rate at edge is < 2% lower than center at 4 UFOV Extrinsic Flood-Field Uniformity Check uniformity for collimators used clinically Both acceptance and annual survey 57 Co sheet source with activity level for < 40 Kcps How many counts? Scales with size. For large FOV, acquire at least 10 million counts Quantitative analysis is optional 6

Intrinsic Off-Peak Uniformity Tests for crystal hydration & other detector problems Both acceptance and annual surveys Use 99m Tc point source and acquire flood images 126 & 154 kev and energy window 20% Visually evaluate images: Multiple hot spots indicate crystal hydration Atypical PMT pattern is due to possible PMT decoupling or other calibration deficiency Intrinsic Off-Peak Uniformity Tests for PMT coupling problems 126 kev 154 kev Intrinsic Spatial Resolution & Linearity Acceptance tests quadrant bar phantom for 99m Tc; NEMA slit phantom is optional Annual survey quadrant bar phantom for 99m Tc Calculate Spatial Resolution FWHM using Hander method on bar phantom images Slits & bars used to evaluate linearity by visual inspection 7

40 35 30 25 20 15 10 5 0-5 0 50 100 150 FWHM 12.38 mm Hander Method The FWHM is calculated as follows: MTF = [2(s ROI2 -m ROI )] 1/2 /m ROI FWHM = 1.058w ROI [ln(1/mtf)] 1/2 s ROI & m ROI from circular ROI, w ROI is bar size 2.12, 2.54, 3.18, 4.23 mm bars Choose quadrant with bars just < expected FWHM Linearity Evaluation Visually inspect quadrant bar phantom for nonlinearity of the slits. The results may be reported as: no observable non-linearity just noticeable and may be less than 1 mm significant (fail) and may be greater than 1 mm. 2.12, 2.54, 3.18, 4.23 mm bars Extrinsic Spatial Resolution Measures system spatial resolution with an installed clinical collimator Acceptance test: measure FWHM for 99m Tc with a line source at a distance of 10 cm, and 57 Co flood source and quadrant bar phantom with one low energy collimator Annual survey - with 57 Co flood source and quadrant bar phantom with Low Side High Side Peak collimator used at acceptance 119.45 testing 14 121.6 24.15 132.25 18.15 134.4 11.29 125.85 Half Max 120.1 Half Max 132.5 Half Peak 8

Extrinsic Planar Sensitivity Detector sensitivity measured in CPM/uCi. Multiple detectors to be within 5% differences Measured for 99m Tc and one low energy collimator for both acceptance test and annual survey The sensitivity source configuration may be a Petri dish, culture flask, or syringe with a source/liquid thickness less than 3 mm 3 ml in 5 ml syringe Decay correct to 1 min. Energy Resolution Measured for 99m Tc only Acceptance testing quantitatively measured with a stored energy spectrum measure kev/channel by measuring distance between 99m Tc and one other radionuclide peak ( 57 Co) Annual survey may do quantitative measure, or by visual inspection of photopeak width at half-max Count Rate Performance Measure intrinsically with 99m Tc Acceptance testing: Optionally measure full count rate characteristic using either decay method, or attenuating Cu plates Measure maximum peak count rate Or optimally use two-source method to measure dead-time Annual survey: Measure maximum peak count rate (in air with point source in syringe) Optionally measure dead-time with two-source method 9

Multiple-Energy Window Spatial Registration Should be tested for nondigital signal processing systems Optional for cameras that use digital signal processing Isotopes that may be used are 201 Tl, 67 Ga or 111 In Measure and compare distances between bars at each energy SPECT Tomographic spatial resolution measured from SPECT acquisition of a line source Image quality test for artifacts, spatial resolution and contrast. Measured from SPECT acquisition of the Jaszczak phantom Center-of-rotation/multiple head registration (COR/MHR) calibration and QC - expected to be performed prior to testing. Tests performed for both acceptance testing and annual survey Tomographic Spatial Resolution Acquisition of 99m Tc line source at a 20 cm AOR Measure FWHM of PSF from reconstructed slices with FBP in both axial and tangential directions Measure FWHM of LSF for planar acquisition of line source at 20 cm distance Compare tomographic and planar spatial resolution. Should be less than 10% difference 10

40 35 30 25 20 15 10-5 Low Side High Side Peak 119.45 14 121.6 24.15 132.25 18.15 134.4 11.29 125.85 34.57 Half Max 120.1 Half Max 132.5 Half Peak 17.29 7 08:07:44 5 0 1200 1000 800 600 400 200 0-200 0 50 100 150 200 250 FWHM 12.38 mm 0 50 100 150 200 250 Low Side High Side Peak 136.5 424 138.6 668 149.3 514 151.4 308 143 971 Half Max 137 Half Max 149.6 Half Peak 485.5 FWHM 12.56 mm SPECT Spatial Resolution Measurement Fill 12 cm capillary tube with 99m Tc ~ 2 mci/ml Center the capillary tube parallel to and on the AOR, and set the radius-of-rotation to 20 cm Acquire 120-128 projection images with a high resolution matrix (128x128 with zoom 2) Reconstruct SPECT cross-sections using FBP Acquire planar stationary image of the capillary tube for each detector at 20 cm Draw line profiles across the SPECT and planar images, and measure the FWHM of the LSF across the images of the capillary tube FWHM of LSF Measurements Planar Image SPECT Slice Planar FWHM: 12.4 mm SPECT FWHM: 12.6 mm SPECT Image Quality Use ACR Accreditation protocol for acquisition and reconstruction with Chang s method for attenuation correction of the Deluxe Model Jaszczak phantom 32 million total counts 120 Projection images acquired over 360 degrees, unless cardiac system Use pixel matrix (128x128) with zoom to achieve pixels of 3-4 mm Use FBP reconstruction, clinical filter window, and attenuation correction 11

Jaszczak SPECT Phantom Jaszczak Deluxe (Data Spectrum Corporation; SPECT.com): Cold Rods 12.7, 11.1, 9.5, 7.9, 6.4, 4.8 mm Cold Spheres 31.8, 25.4, 19.1, 15.9, 12.7, 9.5 mm Small (Mini) for small FOV systems available 99m Tc SPECT & LEHR Collimator Jaszczak Deluxe Phantom Radius-of-Rotation 22 cm (less is better) Chang attenuation correction required with m=0.12/cm 6 mm/slice ACR Phantom Satisfactory Criteria: 19.1 mm sphere observed with high contrast 11.1 mm rods visible Chang Attenuation Correction Attenuation is calculated based on source depth and pre-assigned linear attenuation coefficient. Contour drawn to identify the external boundary of the object. Linear attenuation coefficient is for soft tissue and is assumed to be constant in the entire crosssection (for 140 kev, m=0.12/cm in presence of scatter) Distance (t) is the average depth for all acquisition angles. Correction is applied to all reconstructed slices. t 270 SPECT Slice t 0 t 180 Contour t 90 12

SPECT Phantom Uniformity Significant Ring Artifact! SPECT Phantom Marginal Ring Artifacts Evaluation for COR/MHR Accuracy Tomographic spatial resolution is within specification Sinogram and cyclogram of line source and phantom slices show no artifact 13

Evaluate Projection Images for COR and MHR Errors Left: Sinogram of the line source projections. No discontinuity observed between the two detector heads. Right: Linogram/Cyclogram of the line source projections. No discontinuity observed between the two detector heads. MHR Mis-Alignment in X Top detector misaligned with bottom detector, may lead to distortion and resolution loss in reconstructed images. Hybrid SPECT/CT Test gamma detectors for planar imaging performance Tomographic spatial resolution - test the SPECT as done for SPECT only systems with line source Image quality acquire Jaszczak phantom with same protocol as for SPECT only. Acquire CT of the phantom. Reconstruct using CT for attenuation correction SPECT and CT alignment perform manufacturer alignment test procedure, or evaluate alignment of CT with Jaszczak slices Performed for both acceptance testing and annual surveys 14

SPECT/CT Phantom Fusion SPECT/CT Phantom Fusion SPECT/CT Alignment SPECT & CT alignment procedures may be performed with the manufacturer phantom. 57 Co point sources can be imaged with whose location seen on both the SPECT and CT scans. Alignment should be to within 2 mm. Follow recommended test frequency by the manufacturer. Report results of the SPECT & CT alignment in annual physics survey. 15

CT Image Quality and Dose Assessment Testing of the CT component of the hybrid system may done separately by a CT trained QMP. Is necessary if the CT is used for diagnostic imaging. Recommend the following ACR CT Quality Control Manual Measure CTDI vol may be required by state regulations. Report dose for body SPECT/CT study, and for any adult and pediatric protocols used diagnostically. May include CT image quality and dose assessment in acceptance testing and annual survey reports SPECT/CT - CT Dose CTDI w measured for head and body sections Use standard methods to measure CT dose but with protocols used for SPECT. A challenge to measure on flat panel 14 cm x-ray detector of Philips Brightview. Typical doses of the CT ~1/10 to 1/3 of diagnostic CT. Note also doses for diagnostic CT scans done on unit. For annual physics survey, may report CT dose measurements on the unit made by another qualified medical physicist. SPECT/CT - CT Image Quality ACR CT Phantom may be used for evaluation Daily Perform HU accuracy and noise for water and evaluate for artifacts. Assess CT contrast, noise, spatial resolution monthly Of importance is CT # accuracy. CT# s are translated to SPECT linear attenuation coefficients. For annual physics survey report on HU accuracy, CT contrast, noise, spatial resolution. May be made by another qualified medical physicist. 16

How Long Does it Take? Conclusions Provided a comprehensive review of the testing of gamma camera and SPECT systems. NEMA documents were used a guideline, but tests reduced and simplified to reduce time for performance measurements. Hybrid SPECT/CT is tested as a gamma camera, but with CT for attenuation correction and for image registration. Additional registration test needed. Evaluation of the CT component may be completed separately. Reports of this testing may be included in reports for nuclear medicine testing. 17