EXCELPrime SINGLE WALL STOVE PIPE

Similar documents
SUBMITTAL RECORD. MODEL DuraSeal DS/DSD/DSID } DSD / DSID ONLY

Single-Wall, Double-Wall and Double-Wall Insulated Special Gas Vent. DuraSeal

RIVA I 66. Fire size Riva kW. Heat output

Declaration of Performance (DOP)

Direct Vent System. Gas Pellet Multi-Fuel CATALOG

Declaration of performance (DOP)

Right angle press-fit D-Sub connectors

AIR TERMINALS: COPPER

Declaration of performance (DOP)

Ideal protection for your electrics: häwa cable ducts

inserts

C O M M E R C I A L. CALGARY EDMONTON LETHBRIDGE

Round Self-Sealing HVAC SPIRAL DUCT & FITTINGS

BS up.v.c SOIL, WASTE, VENT PIPES AND FITTINGS

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

FasNSeal & FasNSeal W2. FasNSeal Flex. Single-wall and double-wall special gas vent systems. UL 1738 and ULC S636.

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Terminals, Lugs, and Fasteners

Connectivity Products

CABLE ROUTING SYSTEMS. WIRE CABLE TRAYS - standard open trays PRODUCT INFORMATION

Mounting Options. Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009

All-Fuel Chimney System

Call us on

SEPTEMBER C.CS.1000 / GB

STANDARD GAGE ACTION CONTENT. 03 Calipers Depth Calipers Micrometers Depth Micrometers Tool Sets Dial Gauges...

07. har-link Interface Connectors

Timken Lubrication Delivery Systems. Friction management solutions SM to keep systems running smoothly

TURCK Industrial Connectivity Products

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

401 west fields blvd El dorado springs, Missouri

Technical Data. Care and Maintenance

Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

07. har-link INTERFACE CONNECTORS

Standard Releasing Spear. Manual B215

Round Louvers. Adapters for , 45, 47 & 86. XV.3. Air Distribution

i-series Videoconference Fixture

PP-R & PVC-U Products Catalogue

Temperature Measurement SITRANS TS300

The fireplace is the heart of your home, a centrepiece to which friends and family gather... 2 Studio 3 Steel XS in Metallic Black

The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.

1.1. Cable Ties and Fixings Cable Ties Inside Serrated. UB-Series Cable Ties. Commercial Grade Cable Ties

PARTS VIEW FOR CIDV-30-20

Micrometers. Micrometer Heads

VAREC 5000/5010 SERIES FLAME ARRESTERS

FLEXBOX. Installation Guide

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

FLEXIMARK Cable Marking Systems

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Heat Exchanger Condenser Expanders

TMT470L Temperature Transmitter

Digital Menu Board Wall Mount Installation Instructions

this harness plugs into the back of the Digital Control Center and has individual sets of wires for each electrical component in the hopper shell

Modular plugs, accessories and tooling

SECTION TAPER-LOC DRY GLAZE GLASS RAILING SYSTEMS. A. Monolithic Tempered Glass Dry Glazed Railing Assemblies.

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

Installation Manual. Table of Contents

PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS

Installation Notes TII Model 341 Protector

Gas-actuated thermometer Stainless steel version Model 73

SECTION EGR ELEVATED GLASS RAILING SYSTEMS. A. Tempered Glass Wet Glazed in Elevated Railing Assemblies.

FLEX Ex Spring Clamp Terminal Base

Precision temperature control/sensing

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Adjust-O Magnet Squares

FISCHER MINIMAX TM SERIES

Stoves for fireplaces

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

Airetool Condenser Expanders Selection Guide G-900 Series Heat Exchanger and Condenser Tube Expanders. Airetool Heat Exchanger Condenser Expanders

New Products. Small Tool Instruments and Data Management INDEX. Micrometers. Micrometer Heads. Coolant Proof. Micrometer. Digimatic.

Contura 300 Contura i7. Cubic comfort

Stainless One-touch Fittings. Applicable Tubing. Tube material Tube O.D. Specifications. Thread Nut Sealant (Thread portion) Component Materials

90 Elbows Long Radius

Sensor Mounting Shells and Adaptors

Ø mm. SYSTEM KAN-therm. Steel. Traditional material in modern technology TECHNOLOGY OF SUCCESS ISO 9001

SCH 5S/10S/40S/80S. Stainless Steel/Carbon Steel Butt-welding Fittings

Hubbell Metal Raceway HBL3000 Series Product Applications

Standard Series Standard

AC Micro Style Cordsets and Receptacles

uniquely Clear view NEW Wohler VIS 350 Video inspection, position indicator, home function and locator The Measure of Technology

WHOLESALE PRICE LIST EFFECTIVE

Featured Products - RU Marking Standard on Hoffman brand

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

B&W RearView Camera Installation & Operation

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting

MIRROR POLISHED POSTS See page 46

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Extract from new. Device Connectivity catalogue. HARTING har-flex. People Power Partnership

07. har-link Interface Connectors

Contents. Page 2 TRCTFP101

ROLLING COUNTER SHUTTERS

Catalog C-035 Rev. C

Specification. Radiamatic Detectors and Accessories

MBE Mounts and Adapters

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

0.5mm Pitch Low-Profile Board-to-Board/Board-to-FPC Connectors

Male header, 100% protected against mismating, (1 x 1) mm straight solder pins Pin spacing 3.5 mm 3.81 mm. light gray <_ 8,5_> 3,5 1x1 <_ 9,3_>

PV-MOLD Nonmetallic Pole Riser System

Clamp Together Ducting Catalog

The Trade Soil & Waste Product Guide

Transcription:

SINGLE WALL STOVE PIPE

28 Technical Information Technical Information Certification has been tested and listed by Intertek Testing Services Applications is designed to be used as a connector between a freestanding oil, wood or coal burning stove and a masonry or metal chimney. Allowable Flue Gas Temperatures Max Continuous Brief Forced Firing Tested To 650 C (1200 F) 925 C (1700 F) 1150 C (2100 F) Clearance to Combustible Materials is certified for 18" clearance to combustible materials or otherwise specified by appliance manufacturer instructions. With the addition of a listed Heat Shield, the clearance can be reduced to: 6" dia. - 4" clearance from the shield 7" & 8" dia. - 6" clearance from the shield Construction Single Wall: 22ga steel Seam: Laser seam welded Paint: Forrest Stove Bright flat black Engineering and Design Considerations Maximum allowable overall height: must not exceed 10 feet in length and a maximum of two 90-degree elbows are permitted. To assemble, ensure that the shrunken end is facing down. Place one length on top of another and screw them together using the screws provided. There is no cutting required and all the screw holes are predrilled. easily fits most stoves including cast iron stoves and stoves with oval collars. Single wall stove pipe with smooth, clean lines. Heavy wall, 22ga steel. Laser welded to be perfectly round and does not require assembly like snap lock pipes. Has a 5 year, no questions asked replacement warranty. Without shielding, requires 18" clearance to combustibles in all diameters. With an UL Listed Heat Shield, clearance to combustibles can be reduced to 4" from the exterior of the shield for 6" or 6" clearance for 7 & 8". 4005717

Product Descriptions 29 Length (SW1, SW18, SW2, SW3, SW4) Slip Length (SW1S) Adjustable Length (SWA) Lengths are available in 12", 18", 24", 36" and 48" lengths; 6", 7" and 8" diameter. Slip Length will slide into a regular straight length allowing you to adjust the overall length of a straight run without cutting. The minimum adjustment can be reached only if the length used below the slip length is long enough to accept it. Adjustable Lengths combine a 36" length and a 36" slip length in one box. The SWA provides enough range that it is often the only component required for vertical installations. Length Adjustable Length Length SW1 12 10 5/8 SW18 18 16 5/8 SW2 24 22 5/8 SW3 36 34 5/8 SW4 48 46 5/8 Slip length Slip Length Code Min. Installed Length Max. Installed Length SW1S 1 3/8 10 5/8 SW6S 1 3/8 4 5/8 Adjustable Length Code A MIN. A MAX. B MIN. B MAX. SWA 40 68 38 5/8 66 5/8 Damper Section (SWD) Acts as a 5" length and has a butterfly type incorporated damper. In the closed position, the damper is still 20% open so as not to completely block the chimney. SWD 6 4 5/8 Tee (SWT) Combines a 90 transition with a clean out. Tee Cap (SWTP) not included. C 6SWT 10 5/8 4 1/4 4 3/4 7SWT 10 5/8 4 3/4 4 3/4 8SWT 10 5/8 5 1/4 4 3/4 Tee Cap (SWTP) Caps off the open portion of a Tee. 6SWTP 6 1 7SWTP 7 1 8SWTP 8 1

30 Product Descriptions Elbow (SW45, SW90) Are available in 45 and 90 6SW45 2 5/8 2 1/4 7SW45 2 7/8 2 1/4 8SW45 3 1/8 2 1/2 6SW90 4 3/4 5 3/8 7SW90 5 1/4 5 7/8 8SW90 5 3/4 6 3/8 Slip Elbow 90 (SW90S) Combines a 90 elbow and a slip length in one piece. Code A max. A min. B 6SW90S 19 3/4 4 5 5/8 7SW90S 19 3/8 4 1/2 6 1/8 8SW90S 19 1/8 5 6 5/8 Clean Out Elbow 90 (SW90C) Incorporates an easily removable inspection port that is large enough for a chimney brush. 6SW90C 4 5/8 6 7SW90C 5 1/8 6 1/2 8SW90C 5 5/8 7 Adjustable Elbow 90 (SWA90) The angle of this elbow is variable between 90 and straight. Patent Pending. 6SWA90 5 3/8 6 3/8 7SWA90 5 7/8 6 7/8 8SWA90 6 3/8 7 3/8

Product Descriptions 31 Increaser (SWSI) Small end male Designed to increase the diameter of a system to accommodate a range of flue sizes, appliances and installations. Note: Increasing chimney diameter can reduce draft and increase creosote formation. Be careful to use these components only when appropriate. C SWSI67 6 7 1/8 2 5/8 SWSI68 6 8 1/8 2 5/8 SWSI46 3 7/8 6 1/8 2 1/4 Reducer (SWSR) Small end female Designed to reduce the diameter of a system to accommodate a range of flue sizes, appliances and installations. Note: Decreasing chimney diameter even 1" can have a serious negative impact on chimney performance. Be careful to use these components only when appropriate. C SWSR76 7 6 1/8 2 1/2 SWSR87 8 7 1/8 2 1/2 SWSR86 8 6 1/8 2 1/2 Oval to Round Adapter (8SWOR) Connects to stoves with oval flue collars. Available in 8" only. C D E 8SWOR 9 7 7/8 8 5 3/4 10 3/8 12" Slip Flue Extension (SWEX) Can be used to replace the EXCEL Flue Extension (EX) in installations. This 12" long version will slip into a standard length, eliminating the need for a slip length. C MIN. C MAX. 6SWEX 5 7/8 8 1/2 10-3/4 Barometric Damper Adapter (SWBA) This adapter simplifies the connection between a barometric damper and an or ULTRABlack tee. 6SWBA 6 1/16 2 3/8 7SWBA 7 1/16 2 3/8 8SWBA 8 1/16 2 3/8

32 Product Descriptions Masonry Adapter (SWM) Connects 6" to a 7" or 8" masonry chimney thimble. Note: is not certified to pass through a combustible wall. An EXCELiner Insulated Thimble (ITH, page 39) must be used where there is a combustible wall between the stove and the masonry chimney. C D 6SWM 6 1/4 10 1/2 6 5/8 4 3/4 Masonry Plug (SWMP) Plugs the opening into an existing masonry chimney that had been previously used to vent another appliance. The Masonry Plug is capable of plugging a round opening up to 8" diameter and is lined with insulation to prevent cold drafts. C SWMP 10 1/2 5 7/8 4 3/4 Heat Shield (SW1HS, SW2HS, SW3HS, SW45HS, SW90HS) Reduces clearance required from combustible walls and ceilings. heat shields are UL listed in combination with only and will not reduce the clearance of other brands of stove pipe (each heatshield includes installed heatshield spacers). For other brands of single wall stove pipe, clearances will be reduced to those of an unlisted heat shield installation. Available in 12", 24", 36", 45 and 90 designs. Clearance Diameter Clearance to Combustibles from Shielding 6" 4" 7" 6" 8" 6" CONNECTOR 6" Ø ; 4" MIN. 7" AND 8" Ø ; 6" MIN. SHIELD 18" MIN. Heat Shield Spacer (SWHSS) Used to maintain 7/8" spacing where shields do not overlap. Code A SWHSS 7/8

Product Descriptions 33 Offset Tables Use this table if you are not installing an adjustable length between the elbows. Use this table if you are installing an adjustable length between the elbows. LENGTH BETWEEN OFFSETS 45 Elbows 45 Elbows LENGTH BETWEEN OFFSETS RISE OFFSET RISE OFFSET 6 INCH Ø 6 INCH Ø NO LENGTH 8 1/4 3 1/2 NO LENGTH + L6S - 11 1/2-6 3/4 6" SLIP LENGTH 11 1/2 6 3/4 12" LENGTH + L6S 16 3/4-19 12-14 1/4 12" LENGTH 15 3/4 11 12" LENGTH + L12S 16 3/4-23 1/4 12-18 1/2 18" LENGTH 20 15 1/4 18" LENGTH + L12S 21-27 1/2 16 1/4-22 3/4 24" LENGTH 24 1/4 19 1/2 24" LENGTH + L12S 25 1/4-31 3/4 20 1/2-27 36" LENGTH 32 3/4 28 18" + 12" LENGTH + L12S 28 1/2-35 23 3/4-30 1/4 SWA min 35 3/4 30 3/4 36" LENGTH + L12S 33 3/4-40 1/4 29-35 1/2 SWA max 55 1/2 50 1/2 SWA 36 1/2-55 1/2 31 3/4-50 1/2 7 INCH Ø 7 INCH Ø NO LENGTH 8 3/4 3 1/2 NO LENGTH + L6S - 12-7 6" SLIP LENGTH 12 7 12" LENGTH + L6S 17 1/4-19 1/2 12-14 1/2 12" LENGTH 16 1/4 11 1/4 12" LENGTH + L12S 17 1/4-23 3/4 12-18 3/4 18" LENGTH 20 1/2 15 1/2 18" LENGTH + L12S 21 1/2-28 16 1/4-23 24" LENGTH 24 3/4 19 1/2 24" LENGTH + L12S 25 3/4-32 1/4 20 1/2-27 1/4 36" LENGTH 33 1/4 28 18" + 12" LENGTH + L12S 29-35 1/2 23 3/4-30 1/2 SWA min 36 31 36" LENGTH + L12S 34 1/4-40 3/4 29-35 1/2 SWA max 55 3/4 50 3/4 SWA 37-55 3/4 32-50 3/4 8 INCH Ø 8 INCH Ø NO LENGTH 9 1/2 4 NO LENGTH + L6S - 12 3/4-7 1/4 6" SLIP LENGTH MAX 12 3/4 7 1/4 12" LENGTH + L6S 18-20 1/2 12 1/2-14 3/4 12" LENGTH 17 11 1/2 12" LENGTH + L12S 18-24 3/4 12 1/2-19 18" LENGTH 21 1/4 15 3/4 18" LENGTH + L12S 22 1/4-28 3/4 16 3/4-23 1/4 24" LENGTH 25 1/2 20 24" LENGTH + L12S 26 1/2-33 21-27 1/2 36" LENGTH 34 28 1/2 18" + 12" LENGTH + L12S 29 3/4-36 1/2 24 1/4-30 3/4 SWA min 37 31 1/4 36" LENGTH + L12S 35-41 1/2 29 1/2-36 SWA max 56 3/4 51 SWA 38-56 3/4 32 1/4-51 All measurements are in inches All measurements are in inches