Metasys Integrator Multistack Application

Similar documents
Metasys Integrator GE Lighting Application

Metasys Integrator Allen-Bradley Custom Application

Metasys Integrator United Power Application

Metasys Integrator Graham Application

Metasys Integrator Northern Application

Metasys Integrator Caterpillar Application

Metasys Integrator Powerware Application (previously the Exide Application)

Downloading Metasys Integrator 300 Series Code

Metasys Integrator Cutler-Hammer Application

Metasys Integrator 300 Series Commissioning

Metasys and Companion

N2 Dialer Module. Features and Benefits

Polling the N2 Network or Zone Bus for Devices

Ethernet IP Datalink. Introduction

Extended Digital Controller

Metasys System Configuration Tool (SCT)

Lab and Central Plant Controller

APPLICATION NOTE JC/85

Introduction to the N30 Supervisory Controller

Object Dictionary 1. Pager. Introduction

Metasys N1 Network Integration

TECHNICAL BULLETIN. Using M-Authorize. Using M-Authorize...2. Introduction Key Concepts... 3

Defining Points. Introduction

Direct Connect and Dial-Up on Windows 98

TC-9102 Terminal Controller

Introduction to DX LCD Display

Direct Connect and Dial-Up Connection on Windows 2000 Operating Systems

Network Terminal. Features and Benefits. Metasys Network Sales Resource Manual 635 Operator Devices Section Product Bulletin Issue Date 0190

Using Third-Party Remote Communications Software

BACnet Protocol Implementation Conformance Statement

FieldServer Driver - Serial FS Metasys N2

CF Terminal User s Guide

APPLICATION NOTE. N2 Dial Application. Using N2 Dial...3. Introduction...3. Key Concepts...4

Metasys Web Access. Provides full access to M-Alarm for monitoring and acknowledging alarm messages and generating alarm reports

Metasys Checkout Tool User s Guide

Display. Introduction

N30 Supervisory Controller Installation

Spreadsheet Applications

P2000 Commend Intercom Interface Option

FX Tools Express Software Package

ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

Control System (CS) Object

Modular Room Control (MRC) Series Expansion Board

The Monitoring Software of Chigo CMV DC Inverter Instruction Manual

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Metasys System Extended Architecture

Metasys for Validated Environments (MVE) Installation and Platform Requirements

LN Graphical Programming Interface (GPI) Tool

Network Port. Introduction Page 3. Engineering 9. Installation Procedures 13. Commissioning Procedures 17. Defining Objects 21

Working with Objects and the M-View Screen

Multistate Value/ BACnet Multistate Value

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

Trend Log/BACnet Trend Log

Metasys Web Access System Overview

AS-CVTPROx00-0 Zone Bus/N2 Bus Interface Converter

Analog Data (AD) Object

CCS Handheld VAV Balancing Tool Technical Bulletin

Guidelines and Recommendations for Better Graphics Performance with Integrated N1 Networks

Operator Workstation

IC232 PC- CARD USER S GUIDE

M-Tool. Features and Benefits System Configuration and Project Management. Allows fast adjustment and commissioning of systems

Metasys Installation and Platform Requirements

1550-N2 Revision 1.7 A-B Drives Protocol Interface September 1999

S300-DIN-RDR2SA Address Mode Configuration

Variable Air Volume Modular Assembly (VMA) 1400 Series

XT-9100 Technical Bulletin

MICROCOMPUTER CONTROL CENTER PART NO. FOR

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

Analog Input (AI) Object

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

VAV Modular Assembly (VMA) 1410/1420

M-Bus Central Unit. Use

Smart Equipment Controls (SEC)

Appendix A: Metasys Web Access (MWA) Server Installation Guidelines

Installing the DX LCD Display

1. Safety Danger Warnings Earthing and earth fault protection... 4

M-Alarm Multimedia Extension (MMX)

N2 Analog Input/ BACnet Analog Input

Static Pressure High Limit

GE Consumer & Industrial Electrical Distribution. AF-600 FP TM Metasys. Operating Instructions

FX-DIS Local Controller Display Technical Bulletin

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

Gateway 1400 Reference Manual

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Digital Control Module 140

1.1.1 Software Version Introduction About this Manual References 2

Lumio Release Note Lumio Multi-Touch Communication Protocol

Tank Fluid Monitor 905-D6 WITS OPTION COMMUNICATION BOARD MANUAL IMPORTANT OPERATOR INFORMATION

T8800 series BACnet MS/TP Networked Thermostat Controller

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

Metasys System Extended Architecture Overview

Installation Instructions for: Channel Thermocouple Amplifier

Metasys N2 Communications Protocol Operating Instructions

ELAN DIGITAL SYSTEMS LTD. CF232 COMPACT FLASH CF+ CARD USER S GUIDE

Using Dial-Up with the NDM

Contents. Index 35. VLT HVAC Drive Metasys N2

Transcription:

Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Multistack Application lntroduction Page *3 Application Details *3 Component Requirements *5 Vendor Contact Information 6 Design Considerations 6 Cable Connections 7 Cable Pinouts 7 Connecting the Cable 7 Metasys Integrator Setup *9 Point Mapping Table 11 Metasys Network Setup *13 Mapping to a CS Object 13 Custom Integration *15 * Indicates those sections where changes have occurred since the last printing. 1998 Johnson Controls, Inc. 1 Code No. LIT-6295390 www.johnsoncontrols.com

2 Metasys Integrator Metasys Integrator Multistack Application

lntroduction This document explains the Metasys Integrator Multistack application. Use this document with the Metasys Integrator Technical Bulletin (LIT-6295130) in the Metasys Connectivity Technical Manual (FAN 629.5), which provides information on installing and commissioning Metasys Integrator. For information on vendor equipment, see Multistack documentation (obtainable from a Multistack representative). Application Details Metasys Integrator allows Multistack equipment to become an integral part of the Metasys and Metasys Companion Networks. Once a Multistack Modular Liquid Chiller is connected to a Metasys or Companion Network via the Metasys Integrator, its data is available to the full complement of Metasys Facility Management System (FMS) features, including Change-of-State (COS) monitoring, alarm notification, trend, and totalization. Up to 12 Multistack Modules can be connected together to create a chiller system. A Master Controller collects data from each of the connected chillers, and allows information and commands to be transmitted between chillers and non-multistack devices (such as Metasys Integrator). Each Metasys Integrator vendor port can connect to one Master Controller. Figure 1 shows Multistack and Metasys integration, and Figure 2 shows Multistack and Metasys Companion integration. Metasys Integrator Metasys Integrator Multistack Application 3

N1LAN Standard NCU RS-232 Master Controller Metasys Integrator Multistack Module Multistack Module Multistack Module Multistack Module UNT N2 Bus MULTI1 Figure 1: Multistack Modular Chillers and Metasys Integration Panel Unit M3 Workstation RS-232 Master Controller Metasys Integrator Multistack Module Multistack Module Multistack Module UNT N2 Bus Note: A PC version and converter may be substituted for the Panel unit. multcomp Figure 2: Multistack Modular Chillers and Metasys Companion Integration 4 Metasys Integrator Metasys Integrator Multistack Application

Component Requirements Metasys Release Requirements Metasys Companion Release Requirements Vendor Component Requirements To integrate Multistack Modular Chillers, you ll need the following: properly installed Master Controller and Multistack Modular Chillers RS-232 cable (for connecting the Multistack Modular Liquid Chiller to Metasys Integrator) Metasys Integrator N2 Bus (for connecting Metasys Integrator to the Metasys or Companion Network) portable PC for downloading vendor communication tables (.VCT files) and network setup information, and for running diagnostics cable for connecting portable PC to Metasys Integrator the correct vendor communication table (.VCT file) to download into Metasys Integrator (supplied on diskette) This document describes the RS-232 cable and the vendor communication tables. Multistack documentation describes their equipment. The remaining components are described in the Metasys Integrator Technical Bulletin (LIT-6295130) in the Metasys Connectivity Technical Manual (FAN 629.5). To integrate Multistack equipment into the Metasys Network, you ll need: Metasys Operator Workstation (OWS) software Release 4.0 or higher Metasys Integrator software/firmware Release 2.0 or higher To integrate Multistack equipment into the Metasys Companion Network, you ll need: Metasys Companion Release 4.0 or higher Metasys Integrator software/firmware Release 2.0 or higher RS-232 communication chip installed in Socket U34, next to the battery, marked HD6350 Integration between Metasys Integrator and Multistack has been tested with the Multistack Modular Liquid Chiller. Changes to this equipment or integration of Multistack products not discussed in this document will require additional software development and testing by Systems Products. For information on integrating other products, refer to the Custom Integration section in this technical bulletin. Metasys Integrator Metasys Integrator Multistack Application 5

Vendor Contact Information Design Considerations Multistack, Inc. 365 South Oak Street West Salem, WI 54669 Technical Support Phone: (608) 786-3400 FAX: (608) 786-3450 When integrating Multistack, consider the following: Make sure Multistack equipment is set up and running properly before integrating with Metasys or Companion. (The Multistack representative is responsible for operation of Multistack equipment.) The Master Controller baud rate is set to 2400 and is not adjustable. RS-232 cable distance between Metasys Integrator and the Master Controller can be a maximum of 50 feet. 6 Metasys Integrator Metasys Integrator Multistack Application

Cable Connections Cable Pinouts Use the following cable pinouts for the RS-232 connection between Metasys Integrator and the Multistack Master Controller: Vendor Port A or B on Integrator DB-9 Female RS-232 Port on Master Controlle DB-25 Male Signal RD TD GND Pin 2 3 5 RS-232 (50 ft. maximum) Pin 3 2 7 Signal Rx Tx GND MULTI2 Figure 3: Cable Pinouts Connecting the Cable Connect the female end of the RS-232 cable to either Vendor Port A or Vendor Port B on Metasys Integrator. Connect the male end to the Other Output Port (RS-232 Serial) on the Multistack Master Controller. Metasys Integrator Multistack Master Controller Vendor Port A or B RS-232 Cable Other Output Port (RS-232 Serial) MULTI3 Figure 4: Port to Port Connection Metasys Integrator Metasys Integrator Multistack Application 7

8 Metasys Integrator Metasys Integrator Multistack Application

Metasys Integrator Setup To set up Metasys Integrator, you ll use a portable PC connected to Metasys Integrator Terminal Port. Metasys Integrator setup involves: downloading the correct vendor communication table (.VCT file) setting up the ports setting up the network addressing The following table provides information specific to the Multistack application. For detailed procedures, see the Metasys Integrator Technical Bulletin (LIT-6295130) in the Metasys Connectivity Technical Manual (FAN 629.5). Table 1: Metasys Integrator Setup for Multistack Modular Liquid Chillers Vendor Communication Table (.VCT FILE) Multistack Modular Liquid Chiller Port Setup Baud Rate 2400 Word Length 8 Stop Bits 1 Parity Interface Network Setup Vendor Address 0* Timeout Value Poll Delay Performance Guide MS_MCHIL.VCT None RS-232 5000 ms 55 ms Approximate Scan Time 9 seconds (For a single device) * Although Multistack Chillers do not use addressing, Metasys Integrator requires a value for this parameter. Metasys Integrator Metasys Integrator Multistack Application 9

10 Metasys Integrator Metasys Integrator Multistack Application

Point Mapping Table The following table shows the points available for mapping in the Multistack Modular Liquid Chiller: To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Entering Chill Water Temperature point is 1. Table 2: Multistack Modular Liquid Chiller Points NPT 1 NPA 2 Unit Description 1 2 3 4 5 6 7 8 9 DegF DegF DegF DegF % % # # # Entering Chill Water Temperature Leaving Chill Water Temperature Entering Condenser Water Temperature Leaving Condenser Water Temperature Capacity Demand Current Faults Lead Compressor Number Number of Compressors On BI 1 Chill Water Flow 0=ok, 1=fault BI 2 Condenser Water Flow 0=ok, 1=fault BI 3 Low Chill Water Temp 0=ok, 1=fault BI 4 Power Failure Unit 0=ok, 1=fault BI 5 Phase Failure Unit 0=ok, 1=fault AO AO AO 1 2 3 DegF DegF % Upper Setpoint (Entering Chill Water) Lower Setpoint (Leaving Chill Water) Demand Limit Setpoint BO 1 Chiller Status 0=Off, 1=On 1 Network Point Type 2 Network Point Address Continued on next page... Metasys Integrator Metasys Integrator Multistack Application 11

NPT 1 (Cont.) NPA 2 Unit Description 1 2 3 4 5 6 7 8 9 10 ADI 1 ADI 2 ADI 3 ADI 4 ADI 5 ADI 6 ADI 7 ADI 8 ADI 9 ADI 10 ADI 11 ADI 12 ADI 13 ADI 14 ADI 15 ADI 16 ADI 17 ADI 18 ADI 19 ADI 20 ADI 21 ADI 22 ADI 23 ADI 24 1 Network Point Type 2 Network Point Address 0-9% Capacity 10-19% Capacity 20-12% Capacity 30-39% Capacity 40-49% Capacity 50-59% Capacity 60-69% Capacity 70-79% Capacity 80-89% Capacity 90-100% Capacity Compressor 1 Status Compressor 2 Status Compressor 3 Status Compressor 4 Status Compressor 5 Status Compressor 6 Status Compressor 7 Status Compressor 8 Status Compressor 9 Status Compressor 10 Status Compressor 11 Status Compressor 12 Status Compressor 13 Status Compressor 14 Status Compressor 15 Status Compressor 16 Status Compressor 17 Status Compressor 18 Status Compressor 19 Status Compressor 20 Status Compressor 21 Status Compressor 22 Status Compressor 23 Status Compressor 24 Status Compressor Status 0 = Off 1 = On 2 = High Pressure Fault 3 = Low Pressure Fault 4 = Chill Water Temperature Fault 12 Metasys Integrator Metasys Integrator Multistack Application

Metasys Network Setup Metasys Network Setup is described in the Metasys Integrator Technical Bulletin (LIT-6295130) in the Metasys Connectivity Technical Manual (FAN 629.5). This section contains details specific to Multistack applications. Mapping to a CS Object Table 3: Software Model and CS Object Definition Application Software Model (on Models diskette) Display Attribute (recommended) NT Command Attribute (recommended) Multistack Modular Liquid Chiller MS_MCHIL.DDL BO1 Chiller Status AO1 Entering Chill Water Metasys Integrator Metasys Integrator Multistack Application 13

14 Metasys Integrator Metasys Integrator Multistack Application

Custom Integration For information on integrating products which are not discussed in this document, first refer to the Metasys Compatible Global Catalog, an online list of released Connectivity products. If this list does not provide the information you require, consider using the System Integration Project Data Sheet to request a custom contract from the System Integration Team. Both the Metasys Compatible Global Catalog and the System Integration Project Data Sheet can be accessed from The Advisor by performing the following steps: 1. Click on the Products button located on the left side of The Advisor home page. 2. Click on the Product Literature link. 3. Click on the Metasys link. 4. Click on the Sales button. 5. Click on the Connectivity Sales Resource Manual FAN 629 link. 6. Find the System Integration Project Data Sheet link in the table of contents. Click on this link to view an online copy of the System Integration Project Data Sheet, or click on the Metasys Compatible Global Catalog link below it to view a list of released Connectivity products. The System Integration Project Data Sheet (LIT-6290052) can also be found in the Metasys Connectivity Sales Resource Manual (FAN 629). Metasys Integrator Metasys Integrator Multistack Application 15

Notes Controls Group FAN 629.5 507 E. Michigan Street Metasys Connectivity Technical Manual P.O. Box 423 Metasys Integrator Release 8.0 Milwaukee, WI 53201 Printed in U.S.A. www.johnsoncontrols.com 16 Metasys Integrator Metasys Integrator Multistack Application