TRENDS IN SWITCHGEAR SPECIFICATIONS

Similar documents
Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Medium Voltage Metal-Enclosed Power Capacitor Banks

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Circuit Breakers,Reclosers, Switches, and Fuses

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Medium Voltage Metal-Enclosed Harmonic Filter Systems

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Best practices for making switchgear safer.

Best practices for making switchgear safer

MV Network Switchgear, Protection and Control

Refurbishment of Switchgear and Switchgear Devices

Type VR Electrically Operated Ground and Test Device

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Air-insulated medium-voltage secondary distribution switchgear

LV MCC with Arc Flash Mitigation (AFM) Units

Fundamentals of Circuit Breaker Maintenance. AVO Training Institute, Inc. 2018

GE Industrial Solutions. Aftermarket Solutions. Product Portfolio

White Paper. UL Standards for Power Control System Equipment

aentron Energy System 1 to 900 Vdc

SECTION SWITCHGEAR

Innovation for MV distribution

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

ELECTRICAL SUPPORT SERVICES

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Innovation on Medium Voltage Switchgear

1510 MOTOR CONTROLLERS

ELG4125: System Protection

SIEBREAK-VCB 5-15 kv metal-enclosed interrupter switchgear usa.siemens.com/siebreak

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Benefits, offering and references

UniSec, MV AIS for Secondary Distribution Smart Grid applications

SERIES SD3800 / SD3810 SPECIFICATION

CENTERLINE 2500 Motor Control Centers

Enabling a Solid State Circuit Breaker

T107 - Installation Considerations for AC drives

Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

4. CIRCUIT BREAKERS. Functional Emergency Switching

Package Substation. The efficient solution for your electrical distribution network

SWITCHYARD SYSTEM BC1-SS-11-SD TRAINING SYSTEM DESCRIPTION NRG ENERGY, INC. BIG CAJUN 1

SECTION MEDIUM-VOLTAGE CIRCUIT BREAKER SWITCHGEAR (GAS-INSULATED, VACUUM)

Power Control Systems

Mitigating Arc Flash Hazards

PD-Series. Emergency Standby. General Description. Available Modes of Operation. Standard Features. User Interface. Communication and Controls

EFASOLAR PVStation Solutions

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER

It is the job of the protection system equipment to recognize and remove the fault.

satech TSB-14 MAIN FEATURES

SECTION DISCONNECT SWITCHES

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

TSC Schneider-PDI Agenda

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Medium Voltage Air Insulated Switchgear for Secondary Distribution Product overview

Intelligent Medium Voltage Circuit Breakers With Integral

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Power Systems Communications Implementation of IEC61850 in a Substation Environment

for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages

Survey on new electrical devices with different technology compared to existing electrical devices

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Quick Start Guide TS A

IEC & 2 standard. The reference for safe and reliable LV switchboards

SECTION METAL-CLAD MEDIUM VOLTAGE SWITCHGEAR (VacClad-W)

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

Siemens tiastar TM Motor Control Center (MCC)

MNS ACS880 Switchgear mounted industrial drives

ABB Medium Voltage Days 2016 Asset service innovation Solutions along the lifecycle

Description. Installation. Power supply

VisoVac padmount fault interrupter

This image cannot currently be displayed. Sarel Pelser. ABB Group May 27, 2014 Slide 1

Benefits of Limiting MV Short-Circuit Current in Large Data Centers

Microprocessor protection and automation devices

Arc protection relay. Features Three-phase overcurrent function. Application

VIP 40/45 VIP 400/410

OC IEEE IAS/PES Meeting February 21, 2013

Earth-fault Relay SPAJ 110 C. Product Guide

Standards Update Notice (SUN) Issued: August 11, 2017

UBC Technical Guidelines Section Edition Primary Unit Substation Page 1 of 14

2 in 1 LAN Tester and Multimeter Model:

Advanced Monitoring Solutions for Critical Electric Power Transmission & Distribution Assets

SACE Emax 2 Specification guide

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Document C0. Use for:

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

Solution Mining. tgood.com

DNB Power and Control System Information and Interim Safety Procedures. Version draft 5/06/08

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

Transcription:

TRENDS IN SWITCHGEAR SPECIFICATIONS What changes are we seeing in equipment specifications? What s being discussed in client meetings? What s happening in the market to support these requests?

EQUIPMENT TYPE Arc Resistant Switchgear and MCC Equipment Configurations Arc Resistant NEMA 3R non-walk-in Mixing equipment types on a single line-up Close-coupling MCC with switchgear Mixing different manufacturer s arc resistant designs in a single line-up Arc Resistant Utility Metering Enclosures

EQUIPMENT SIZE The perception of a trend toward smaller equipment not always true The requested size of the equipment is often based on the cost of real estate at the installation The actual size is dictated by the type of equipment. As an example; AR rated equipment generally cannot be reduced in size without retest

EQUIPMENT SIZE Complete front access (no rear doors) Smaller gear generally means more difficult installation and repair The GIS footprint is becoming more interesting to users, but the costs associated with SF 6 and the EPA are sending mixed signals

SWITCHGEAR RATINGS Short-Circuit Current Not as much emphasis in higher current Dielectric A trend toward higher than standard for MV gear. No real change in LV gear Continuous Current A trend toward higher continuous current and a trend against using force-cooling

SWITCHGEAR RATINGS Interest in 15kV ratings for Motor Control Interest in higher amperage HRG Increased interest in VFDs with more exotic configurations

SWITCHGEAR RATINGS IEEE Design Testing Circuit Breaker Testing is moving more to IEC methods, but the IEEE ratings are retained Switchgear Testing and Ratings are solidly IEEE

ADDITIONAL TESTING Design Tests Combinations of Design Tests using Different Standards Design Tests Made from Customer Specifications Production Tests Partial Discharge Testing Design Testing on Production Equipment

INSTALLATION AND COMMISSIONING Trend toward hiring third party companies to do the installation and commissioning The third party is viewed as impartial

TRAINING When onsite maintenance teams exist, the trend is to have the supplier train the maintenance and operations personnel General trend toward hiring outside service companies to eliminate the cost of onsite teams

FEATURES Longer Life No Maintenance Monitoring Communication Remote Operation Arc Fault Protection Seismic Ratings Customized G&T Devices

FEATURES Verification of Vacuum (vacuum breakers) Integrated Ground Switch Metal-Clad switchgear with switches

FEATURES Longer Life What Constitutes Longer Life in switchgear used in the power and petro-chem markets? The unwritten rule is 40 year life expectancy Life of the interrupter? Number of mechanical operations of the mechanism? Number of electrical operations? Time between maintenance? Or is It just the time the equipment stands without rusting out?

FEATURES Longer Life What Constitutes Longer Life for equipment used in the data processing industry? Typical life is 5 years Switchgear is considered disposable Does longer life increase the value in this market?

FEATURES - No Maintenance What Constitutes No Maintenance? Sealed in an air-tight enclosure? No lubricated parts? No periodic adjustments?

FEATURES Monitoring NO DATA!!! System Status and Action Instructions only Smart Grid Communications/Connectivity Compliance with various protocols Compliant with local firewall

FEATURES Monitoring Monitored Conditions Circuit Breaker Operation Partial Discharge Atmospheric Conditions Bus and Circuit Breaker Temperatures

FEATURES Monitoring Circuit Breakers (general) Are the coils functional? Test without operating the circuit breaker Vacuum Circuit Breakers Test vacuum while in service Visible contact break

FEATURES Communication Communication is a tricky area for most companies Are communication lines susceptible to hacking? Most relays come with communication IEC 61850 is being spec d for relays Most monitoring and detection systems offer communication

FEATURES Remote Operation Remote Racking Circuit Breakers and Auxiliary Rollout Trucks External On-board Remote Control Racking Circuit Breaker Operation Communication with monitoring systems

FEATURES Arc Fault Protection Arc Resistant Switchgear Mechanical Specialized Relays and Protective Devices High-speed devices to trip or commutate the fault current

FEATURES Arc Fault Protection Standard NEMA 1 Switchgear with Specialized Relays and Protective Devices Extension to Existing Equipment Increasing inquiries for making the installed base of non-ar equipment into AR rated gear by adding relay and sensing packages

FEATURES Arc Fault Protection Questions about IEEE Arc Resistant Rating Type 2C are more frequent. This indicates two things: Concern for reducing equipment down time Operators are working in energized equipment

FEATURES Seismic Ratings Increased interest in seismic rated equipment Changes in seismic activity Changes in the ratings of locations Revisions to building codes There is still no standardized rating. The various test procedures do not produce results that are comparable.

FEATURES Customized G&T Users of G&Ts have always requested the device be customize to meet their operating procedures Remote/Closed-door racking Most commonly requested with AR switchgear

FEATURES Verification of Vacuum Vacuum Circuit Breakers have two characteristics that are considered negative: You cannot see inside them to verify contact part (visible break) Monitoring vacuum while energized is not available

FEATURES Switches in Metal-Clad Metal-Clad switchgear by definition requires that the primary switching devices be drawout. That means a switch on a breaker truck or similar racking means. Stationary switches do not comply, however; Load break switches Disconnect switches Grounding switches are all specified in Metal-Clad designs

FEATURES Integrated Ground Switch Automatic/Manual Static Ground Fault Making

EQUIPMENT ROOM Batteries. Slow transition from Lead to Lithium Batteries. Fire-rated walls on the building Major changes to buildings due to the government rule changes with regard to insulation, lighting, etc.

What Did I Miss? Questions