E-STOP relays, safety gate monitors

Similar documents
E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relay, safety gate monitor

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Two-hand control unit

E-STOP relays, safety gate monitors

Safe monitoring relays

Two-hand control unit

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Contact expander modules

Safe monitoring relays

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PNOZ s1. Safety relays. Operating Manual EN-07

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

PNOZ s2. Safety relays. Operating Manual EN-07

20 inputs for connecting, for example:

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

PNOZ s9. Safety relays. Operating Manual EN-08

Faults on the system Proximity switch connection technology:

Datasheet - SRB 402EM-24V

Electronic monitoring relays PMDsrange

Datasheet - SRB 301LC/B-24V

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Datasheet SRB301ST 24V (V.2)

PNOZ X1. } Safety relays. Operating Manual EN-08

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Datasheet - SLB 200-C04-1R

MSR178DP. Description. Features. Specifications

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

PSR UC/ESAM4/3X1/1X2/B

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

PHOENIX CONTACT Features

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

PSR DC/ESP4/2X1/1X2

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

Non-Contact Safety System CES-AZ

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Datasheet - CSS 11-30S-D-M-ST

Datasheet - AZM 200SK-T-1P2PW

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Transcription:

Unit features Safety gates Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 2 semiconductor outputs Connection options for: E-STOP pushbutton Safety gate limit switch Reset button LED indicator for: Switch status channel 1/2 Supply voltage Reset circuit Input circuits Semiconductor outputs signal: Switch status channel 1/2 Supply voltage is present Plug-in connection terminals (either spring-loaded terminal or screw terminal) See order reference for unit types Safety features ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Sicherheitseigenschaften Zusatz - AC/DC-Gerte_PNOZ The tranformer is short circuitproof. An electronic fuse is used on a DC supply. SÜDDEUTSCHLAND Unit description Bestimmung/Gertebeschreibung NOT-AUS, Schutz_PNOZ The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Zulassungen Block diagram Blockschaltbild A1 A2 S11 S12 S21 S22 1 2 7 13 23 33 43 53 63 73 81 ~ = Input Input Input Reset/ Start Reset/ Start K1 Power = = Feedback 0 V24 V K2 B1 B2 Y1 Y2 Y30 Y31 Y32 Y35 14 24 34 44 54 64 74 82

Function description ][Funktionen_einkanalig Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ][Funktionen_zweikanalig_mit_quer_ber Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, Timing diagram short circuits in the input circuit and, with a monitored reset, in the reset circuit too, shorts between contacts in the input circuit. ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_manuStart Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ][Funktionen_berStart_allg Monitored reset: Unit is active once the input circuit is closed and then the reset circuit is closed and opened again. the reset circuit is closed and then opened again once the input circuit is closed. ][Funktionen_Kontaktvervielfachung Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Zeitdiagram_auto_manu_ueber1_aux_semiRUN_semiCH 1 2 3 a b a b POWER Reset/Start Input Output safe Output aux. Out semi RUN Out semi CH t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t3 Key Power: Supply voltage Reset/Start: Reset circuit -, 7 Input: Input circuits S11-S12, S21- S22, 1-2 Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 Wiring ][Verdrahtung_Si_unverz_1Hi_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 are safety contacts, output 81-82 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: Output aux: Auxiliary contacts 81-82 Out semi RUN: Semiconductor output supply voltage Y35 Out semi CH: Semiconductor output switch status Y32 : Automatic reset : Manual reset : Monitored reset I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. a: Input circuit closes before reset circuit b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation t 3 : Recovery time -2

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC A1 A2 L1 N B1 L+ B2 PE B2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts S21 S22 S12 S11 2 1 S1 E-STOP with detection of shorts across contacts S11 S12 S22 2 1 S21 S1 Safety gate without detection of shorts across contacts S21 S22 S12 S11 2 1 S1 Safety gate with detection of shorts across contacts S11 S12 S22 S21 2 1 S1 S2

Reset circuit Reset circuit E-STOP wiring (single-channel) Safety gate (single-channel) E-STOP wiring (dual-channel) Safety gate (dual-channel) Automatic reset Manual reset Monitored reset 7 7 Feedback circuit Feedback circuit Automatic reset Monitored reset Contacts from external contactors Y1 Y2 13 (23... 73) 14 (24... 74) K5 K6 K5 K6 L1 N Y1 Y2 13 (23... 73) 14 (24... 74) K5 K6 K5 K6 L1 N Semiconductor output Y31 Y32 Y35 Y30 24 V DC SPS Input SPS Input 0 V Key S1/S2 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration Klemenbelegung Installation Montage_PNOZ_X The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions Abmessungen * with spring-loaded terminals 121 (4.76") 94 (3.70") 90 (3.54") * 101 (3.98")

Notice ][WICHTIG_PDB_alt This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC15: 230 V DC13: 24 V Lebensdauerkurve DC1: 24 V AC1: 230 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœuvres x 10 3 NL Aantal schakelingen x 10 3 ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage U B AC 24 V, 110-120 V, 230-240 V Supply voltage U B DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 9.0 VA Power consumption at U B DC 3.5 W Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 50.0 ma Reset circuit DC: 24.0 V 70.0 ma Feedback loop DC: 24.0 V 70.0 ma Number of output contacts Safety contacts (S) instantaneous: 7 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Contact material AgSnO2 + 0.2 µm Au -6

Electrical data External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 6 A Semiconductor outputs (short circuit proof) 24.0 V DC, 20 ma External supply voltage 24.0 V DC Voltage tolerance -20 %/+20 % Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 50 Ohm single-channel at U B AC 100 Ohm dual-channel with detect. of shorts across contacts at U B DC 15 Ohm dual-channel with detect. of shorts across contacts at U B AC 20 Ohm Min. input resistance in the starting torque 43 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 t M in years 20 Times Switch-on delay with automatic reset typ. 450 ms with automatic reset max. 680 ms with automatic reset after power on typ. 450 ms with automatic reset after power on max. 630 ms with manual reset typ. 450 ms with manual reset max. 680 ms on monitored reset with rising edge typ. 390 ms on monitored reset with rising edge max. 550 ms Delay-on de-energisation with E-STOP typ. 17 ms with E-STOP max. 30 ms with power failure typ. 40 ms with power failure max. 60 ms Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 100 ms Min. start pulse duration with a monitored reset with rising edge 30 ms Simultaneity, channel 1 and 2 Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78

Environmental data Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.00 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG No. 777080, 777083, 777086 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG No. 777080, 777083, 777086 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG No. 777080, 777083, 777086 Torque setting with screw terminals 0.50 Nm No. 777080, 777083, 777086 Cross section of external conductors with spring-loaded terminals: 0.20-1.50 mm², 24-16 AWG No. 787080, 787083, 787086 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 No. 787080, 787083, 787086 Stripping length 8 mm No. 787080, 787083, 787086 Dimensions Height 101.0 mm No. 787080, 787083, 787086 94.0 mm No. 777080, 777083, 777086 Width 90.0 mm Depth 121.0 mm Weight 630 g No. 787080, 787083, 787086 640 g No. 777080, 777083, 777086 Technische Daten_Satz No. No. stands for order number. Technische Daten_Satz Normen The standards current on 2009-11 apply. ][Dauerstrom_ACDC Conventional thermal current Number of contacts I th (A) at U B DC I th (A) at U B AC 1 8.00 A 8.00 A 2 8.00 A 8.00 A 3 8.00 A 6.80 A 4 7.20 A 5.90 A 5 6.50 A 5.30 A 6 5.90 A 4.80 A 7 5.50 A 4.50 A Bestelldaten -8

Order reference Type Features Terminals Order no. C 24 VAC/DC Spring-loaded terminals 787 080 24 VAC/DC Screw terminals 777 080 C 110-120 VAC 24 VDC Spring-loaded terminals 787 083 110-120 VAC 24 VDC Screw terminals 777 083 C 230-240 VAC 24 VDC Spring-loaded terminals 787 086 230-240 VAC 24 VDC Screw terminals 777 086