Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Similar documents
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Absolute Shaft Encoders ACURO industry

TECHNICAL DATASHEET Stainless Steel Encoders AC 59 / 61 - Parallel

VAL-2. Plug-in Mini ISO Valves 2x2/2, 2x3/2, 5/2 and 5/3 valves ISO , Size 18 mm. Technical data

Digital electropneumatic positioner

Pneumatic Control/Feedback

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Pneumatic Control/Feedback

Digital electropneumatic positioner

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Digital electropneumatic positioner

Multipole and Fieldbus

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Digital electropneumatic positioner SideControl

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Ø 58 mm, depth 48 mm Shaft dimension. Hollow Ø 15 mm, solid Ø 6 or 10 mm Shaft loading (axial and radial)

Digital electropneumatic Positioner for the integrated mounting on process control valves

Control Head for the integrated mounting on process valves

EAM PARALLEL - SSI MULTITURN ABSOLUTE ENCODER

Control head for hygienic process valves

Control Head for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Digital electropneumatic Positioner SideControl

Pneumatic Control/Feedback

Incremental Encoder with Hollow Shaft

M23 Connectors and cables

2005 / 2012 / 2035 Series

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

26360, NAMUR. Technical data

Control Head for the integrated mounting on process valves

SPCH/ Big bottle blowing block

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Multi-axis controller V 8 / VV 8

Float switch For industrial applications Model RLS-1000

Cube20. Application-oriented. Installation-friendly. Efficient

Rotary Measuring Technology

Digital electropneumatic Positioner for the integrated mounting on process

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Digital electropneumatic Positioner for the integrated mounting on process control valves

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure

More Precision. colorsensor // Colour Sensors, LED Analyzers

Inclination sensors 2-dimensional, measuring range up to ±90

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Control head for decentralized automation of ELEMENT process valves

PowerDRIVE-Positioning GEL 6110 Technical information Version General Features Advantages Fields of application

Rotary Measurement Technology Absolute Encoders, Singleturn

TECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2

More Precision. colorsensor // Colour Sensors, LED Analyzers

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

UNI EN ISO Description of the SSI multiturn absolute encoder

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Process Controller

Pneumatic Control Unit for the integrated mounting on process valves

Connecting cables for valves, plug pattern ZC, metric screw Type codes

More Precision. wiresensor // Draw-wire displacement sensors

AMx58x P. User Manual. 2 Identification

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

Rotary Measurement Technology Absolute Encoders, Multiturn

MPreC - Pressure Relief Device Order specification sheet

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

CABLE-D...SUB VARIOFACE system cable with D-SUB female connector and pin strip. Data sheet _en_07. 1 Description. 2 Table of contents

80265 series, 3/2 Indirect solenoid actuated poppet valve

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

Note: KLASCHKA КB WIDENT/P 1/9

Accessories Fieldbus Box

Operating pressure. N/en/en

More Precision. Draw-wire displacement sensors

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet

More Precision. wiresensor // Draw-wire displacement sensors

M8/M12 I/O Distribution Box.

Multipole and Fieldbus

HERION SERIES Indirect solenoid actuated spool valves

Analog output linear. Wear free, high resolution High shock resistance Servo flange mounting U8 I1

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

Installation Instructions Temperature transmitter TAA /00 06/2011

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

ENCODER. Profibus Multiturn. Series , Key-Features:

Digital electropneumatic Positioner for the integrated mounting on process control valves

Product Information ECI 1118 EQI 1130 ECI 1119 EQI Absolute Rotary Encoders without Integral Bearing

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Absolute Encoders Multiturn

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Micro automation platform

MobileView Junction Box

Multiturn absolute encoder

Operating pressure. N/en/en

INDUSTRIAL PNEUMATICS - valves

Inclination sensors 1-dimensional, measuring range

ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable.

Industrial Communication System

Operating pressure (bar)

More Precision. Draw-wire displacement sensors

Transcription:

Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface range of address 0-31 AS4 = AS-Interface range of address 0-62 AS5 = AS-Interface (for LF-10-510-HN-412 and LF-10-511-HN-412) range of address 0-31 B1 = Profibus-DP B6 = CANopen Pilot supply options 0 = internal pilot supply E = external pilot supply Tube connection options 40 = l 4 mm on ports 2 and 4, G1/4 on port 1 41 = l 4 mm on ports 2 and 4, l 8 mm on port 1 42 = l 4 mm on ports 2 and 4, l 10 mm on port 1 60 = l 6 mm on ports 2 and 4, G1/4 on port 1 61 = l 6 mm on ports 2 and 4, l 8 mm on port 1 62 = l 6 mm on ports 2 and 4, l 10 mm on port 1 Design and function Manifold system with integrated electrical connection including LED indicators. Each station can accommodate two 3/2-way valves or one 5/2- or 5/3-way valve. All connections are accessible from the front. The valves and the multi-pin plug with cable must be ordered separately. The manifold can be mounted with 4 M5 screws from bottom or from top using the mounting bracket RE-10-B-01 or on a DIN-rail (screws are included). The valve terminal is delivered pre-assembled and function-tested. If not specified with the order, valve configuration is as follows: Valves are mounted according to their order number, starting with high numbers on the side of the multi-pin, ending with low numbers on the opposite side, followed by blind plates (if ordered). Technical data AS-Interface Profibus-DP CANopen Multi-pin Number of stations 4, 8, 12 4, 8, 12 4, 8, 12 4, 6, 8,10,12 Power range see valve Temperature range + 5 C + 50 C (+ 41 F... + 122 F) Voltage 24 V DC ± 10 % Voltage tolerance 5 % + 10 % Voltage bus 18,5 31,6 V DC 7.050 Subject to change

Technical data AS-Interface Profibus-DP CANopen Multi-pin Power consumption each solenoid 1) 1.1 W 1.1 W 1.1 W 1.1 W each bus system 4.3 W 4.3 W each slave 1.1 W Status indicator (LED): Solenoid active yellow yellow yellow yellow error red red red Power valve active green green green (3 internal circuits) (3 internal circuits) (3 internal circuits) error off off off Power fieldbus green green Status fieldbus active green (1 x each Slave) green green error red (1 x each Slave) red red Fieldbus online green Fieldbus error red EMC circuit Power with Polarized circuit protection and built-in surge protection Electrical connection Power in AS-Interface M12 socket M12 socket D-Sub clamp 5-pin, 4-pin, 26-pin A-code A-code (high density), Power out common GND 7 Bus in AS-Interface M12 socket M12 socket clamp 5-pin, 5-pin, B-code A-code Bus out M12-plug M12-plug 5-pin, 5-pin, B-code A-code Address selection Low voltage Bus by Bus by switch plug 2 rotary switches 2 rotary switches Ø 1.3 mm and (Adr. 1 99) (Adr. 1 99) Slave selection by DIP-switch Baud rate Bus 9.6 kbit/s 10 kbit/s 12 Mbit/s 1 Mbit/s max. cable length Bus 50 1200 m 50 1600 m depends on Baud rate Service interface RS232 RS232 Bus terminator over external Profibus- over external CANopen- Terminator 2) Terminator 2) Protection IP 65 acc. EN 60529 in connection with the AIRTEC cable 28-ST-10-M1-26- 1) The status display consumes 0.25 W of the 1.3 W power consumption. 2) Bus termination resistance is available for Profibus-DP and DeviceNet as an accessory (see page 7.054). Subject to change 7.051

Multi-pin Bus-Terminal 1 = pressure supply, G1/4 2, 4 = outlets, fittings for tube l 6 mm 3, 5 = exhausts, G1/4 82, 84 = solenoid exhausts, G1/8 Manual override spring return: press down detent: press and turn Order number A B C ± 0,3 D RE-10/04-M-1-040 or -060 117 31.5 62 45 RE-10/06-M-1-040 or -060 138 52.5 83 45 RE-10/08-M-1-040 or -060 159 73.5 104 45 RE-10/10-M-1-040 or -060 180 94.5 125 45 RE-10/12-M-1-040 or -060 201 115.5 146 45 RE-10/04-B1-040 or -060 RE-10/04-B6-040 or -060 132 31.5 62 60 RE-10/04-ASx-040 or -060 1 RE-10/08-B1-040 or -060 RE-10/08-B6-040 or -060 174 73.5 104 60 RE-10/08-ASx-040 or -060 1 RE-10/12-B1-040 or -060 RE-10/12-B6-040 or -060 216 115.5 146 60 RE-10/12-ASx-040 or -060 1 1 ASx stays for the versions AS3, AS4 and AS5 according to the order code series RE-10. 7.052 Subject to change

Pin assignment fieldbus-connection for series RE-10 POWER IN Plug M12 5-pin A-code (POWER 24V) 1) 1 +24V Power supply-terminal 2 n. c. not connected 3 GND Ground for 24 V DC 4 n. c. not connected 5 n. c. not connected BUS IN Plug M12 5-pin B-code 1 n. c. not connected 2 A RS485A (Tx/Rx-N) 3 n. c. not connected 4 B RS485B (Tx/Rx-P) 5 Shield 2) Shield BUS OUT Socket M12 5-pin B-code 3) 1 +5V Power supply termina 2 A RS485A (Tx/Rx-N) 3 GND Ground for +5V 4 B RS485B (Tx/Rx-P) 5 Shield Shield 7 POWER IN Plug M12 4-pin A-code (POWER 24V) 1) 1 +24V Power supply-terminal 2 n. c. not connected 3 GND Ground for 24 V DC 4 n. c. not connected BUS IN Plug M12 5-pin A-code 1 SHLD Shield 2) 2 CAN V+ CAN Supply 3 GND CAN Ground 4 CAN H CAN high 5 CAN L CAN low BUS OUT Socket M12 5-pin A-code 3) 1 SHLD Shield 2) 2 CAN V+ CAN Supply 3 GND CAN Ground 4 CAN H CAN High 5 CAN L CAN Low 1) The pin assignment is according DESINA-Norm Rev. 2.0 for M12 actuators. The pins 2, 4 and 5 are not connected. 2) The shield can be connected to the metal collar of the plug (improves the shield and is recommended) or at pin 5. 3) An unused socket connection must be terminated with the termination resistance. Subject to change 7.053

Pin assignment Connector cable 28-ST-10-M1-26- For valve terminals with 4 12 stations. Pin Solenoid Wire colour 1 1 white 2 2 brown 3 3 green 4 4 yellow 5 5 grey 6 6 pink 7 7 blue 8 8 red 9 9 black 10 10 violet 11 11 grey/pink 12 12 red/blue 13 13 white/green Pin Solenoid Wire colour 14 14 brown/green 15 15 white/yellow 16 16 yellow/brown 17 17 white/grey 18 18 grey/brown 19 19 white/pink 20 20 pink/brown 21 21 white/blue 22 22 brown/blue 23 23 white/red 24 24 brown/red 25 0V white/black View on valve terminal (Plug) D-Sub 26-pin Solenoid layout Wiring colour acc. to DIN 47100 (coloured or assigned with numbers). Valve and accessories for series RE-10 Valves LF-10-310/2-HN-412 LF-10-312/2-HN-412 LF-10-314/2-HN-412 LF-10-510-HN-412 LF-10-511-HN-412 LF-10-520-HN-412 LF-10-530-HN-412 LF-10-533-HN-412 LF-10-534-HN-412 2 x 3/2-way closed 2 x 3/2-way open 2 x 3/2-way open/closed 5/2-way with air spring 5/2-way with mech. spring 5/2-way double solenoid 5/3-way center position closed 5/3-way center position exhausted 5/3-way center position pressurized Single elements RE-10-DT-01 Dividing plate for P-chanel RE-10-ES Element for external pilot supply RE-10-P-01 Element for additional air supply RE-10-V-EP Blind plate for valve and solenoid position RE-10-B-01 Bracket for flange mounting RE-10-MS-01 Kit for DIN rail mounting 28-ST-10-M1-26-105 Multi-pin connector, D-Sub 26-pin, 5 m cable 28-ST-10-M1-26-110 Multi-pin connector, D-Sub 26-pin, 10 m cable 28-ST-RE-16-01-B1 Connector kit RE-46 (can also be used for RE-10), Profibus-DP, in and out 28-ST-RE-16-02-B1 Connector kit RE-46 (can also be used for RE-10), Profibus-DP termination resistance 28-ST-RE-16-01-B6 Connector kit RE-46 (can also be used for RE-10), CANopen, in and out 28-ST-RE-16-02-B6 Connector kit RE-46 (can also be used for RE-10), CANopen termination resistance Cable for fieldbus on request. 7.054 Subject to change

Valves LF-10 for valve terminal RE-10 300 Nl/min (0.305 Cv) LF-10-310/2-HN-412 LF-10-312/2-HN-412 LF-10-314/2-HN-412 LF-10-510-HN-412 LF-10-511-HN-412 LF-10-520-HN-412 LF-10-530-HN-412 LF-10-533-HN-412 LF-10-534-HN-412 7 Design and function Spool valve actuated by an electrical signal. Order number 1) LF-10-310/2-... LF-10-312/2-... LF-10-314/2-... LF-10-510-... LF-10-511-... LF-10-520-... LF-10-530-... LF-10-533-... LF-10-534-... Function 2 x 3/2-way 2 x 3/2-way 2 x 3/2-way 5/2-way 5/2-way 5/2-way 5/3-way 5/3-way 5/3-way closed open open/closed air spring mechanical double center pos. center pos. center pos. spring return solenoid closed exhausted pressurized Connection Flange Nominal size 4 mm Nominal 300 220 220 / 300 300 300 300 280 300 flow Qv 2) (0.305 Cv) (0.224 Cv) (0.224/0.305 Cv) (0.305 Cv) (0.305 Cv) (0.305 Cv) (0.285 Cv) (0.305 Cv) Pressure 1.5 8 bar 1.5 8bar 3 8 bar 1.5 8bar 3.5 8 bar range 3) (21.75 116 psi) (21.75 116 psi) (43.5 116 psi) (21.75 116 psi) (50.75 116 psi) Pressure range 4) 1.5 8 bar (21.75 116 psi) External 1.5 8 bar 1.5 8bar 3 8 bar 1.5 8bar 3.5 8 bar pilot pressure (21.75 116 psi) (21.75 116 psi) (43.5 116 psi) (21.75 116 psi) (50.75 116 psi) Response on 14 ms 18 ms 14 ms 20 ms 16 ms 15 ms time 5) off 22 ms 28 ms 30 ms 30 ms 30 ms Temperature range 5 hc... + 50 hc (+ 23 F... + 122 F) Materials Body: Al (anodized), plastic, Seals: NBR, plastic, Inner parts: Al, POM, stainless steel and brass Medium Compressed air in accordance with ISO 8573-1: 2010, Class 7:2:4 and free of aggressive additives. Operating voltage 24 V DC 5 % / + 10 % (22,8 V 26,4 V) Power consumption 0,8 W je pilot valve Degree of protection IP 65 according to EN 60529, when assembled on RE-10 Weight 0.050 kg 0.044 kg 0.042 kg 0.052 kg 0.050 kg (0.10 lb.) (0.09 lb.) (0.092 lb.) (0.11 lb.) (0.115 lb. 1) Please specify complete according to the order codes (see below circuit symbols). 4) For external pilot pressure. 2) Flow Qy from 1 to 2 (1 to 4) in Nl/min. 5) Response time at 6 bar acc. CETOP 111 P. 3) For internal pilot pressure. Subject to change 7.055