ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02

Similar documents
AS-Interface Safety at Work

AS-I Safety Monitor ASM1/ASM1E/ASM2E

AS-Interface Safety Monitor. Connecting and Operating Instructions Version V 3.0

MANUAL VAS-*A-K12, VAS-*A-K12-U, VAS-*A1L-K12 AS-Interface Safety Monitor

AS-i Sicherheitsmonitor ASM1/ASM1E Anschluss- und Betriebsanleitung. AS-i Safety Monitor ASM1/ASM1E Connecting and Operating Instructions

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

CONFIGURABLE SAFETY RELAYS

Phone: Fax: Web: -

MSI-RM2 Safety Relays

System manual AS-i safety monitor AC041S /00 05/2013

Phone: Fax: Web: -

Phone: Fax: Web:

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

AS-Interface Safety at Work

MSI Safety Relays compact and versatile

2 Up to d AOPDs MSI-T 470

MSI-T Safety Relays. SAFE IMPLEMENTATION AND OPERATION Original operating instructions. make technical changes. We reserve the right to

Operating instructions. Speed monitor D / / 2014

PHOENIX CONTACT - 07/2006

AS-i Safety Relay Output Module with Diagnostic Slave

Operating instructions. Standstill monitor A / / 2011

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Datasheet - SRB 301LC/B-24V

SAFETY COMMAND DEVICES

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions. Switching amplifier DN0210 DN / / 2015

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Datasheet - SRB 402EM-24V

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Safety controller unit B1 /

Safety Temperature Limiter TT-STL 50

FL MC 2000E (SM40) LC

Operating Manual FPGA-based High-Speed Micro-PLC

Optical distance sensors. Dimensioned drawing

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection

AS-i Safety Relay Output Module with Diagnostic Slave

MSI Safety Devices PRODUCT INFORMATION

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Datasheet SRB301ST 24V (V.2)

Energetic diffuse reflection light scanner. Dimensioned drawing

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

PHOENIX CONTACT Features

AS-i Safety Monitor Version 3.10 with Muting functionality

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Application Technique. Safety Function: Safety Camera with E-stop

BMF400 Input/output module

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

AS-i 3.0 motor module

DALI Professional Controller-4. Control unit Operating instructions

Industrial motor controller for brushed DC motors 24 VDC

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Power supply CP-C 24/5.0

Power supply CP-D 12/2.1 Primary switch mode power supply

ELR H3-IES-PT- 24DC/500AC-...

RoHS. High shaft load capacity. Shock / vibration resistant

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection

Mounting and System Description for SSZ-Safety-Bumpers

Operating Instructions

TRIO-DIODE/12-24DC/2X10/1X20

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

PNOZ s1. Safety relays. Operating Manual EN-07

PHOENIX CONTACT - 12/2007

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

PHOENIX CONTACT - 01/2007

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Industrial motor controller for brushed DC motors 24 VDC

Mounting and System Description for SSZ-Safety-Switching-Rails

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Safety Monitoring Relays

Operating instructions Evaluation system for flow sensors VS / / 2013

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Optical laser distance sensors. Dimensioned drawing

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

User's Manual. english

SMARTSCAN INFORMATION

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

CMC III Universal Sensor

PI-EX-ME-2NAM/COC-24VDC

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

STEP-PS/1AC/24DC/1.75

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Datasheet - RSS 36-D-R-ST

Transcription:

ASM1, ASM1E, ASM2E AS-i Safety Monitor 50101229-2009/02 Technische Änderungen vorbehalten Subject to change without prior notice

Information on the use of the connecting and operating instructions These connecting and operating instructions contain information on the proper and effective use of the AS-i safety monitor. Safety and warning notices are labelled with the symbol. Leuze electronic GmbH + Co. KG is not liable for damages caused by improper use. Knowledge of these instructions is an element of proper use. Reprinting and duplication, including excerpts, are permissible only with the express approval of: Leuze electronic GmbH + Co. KG Liebigstrasse 4 82256 Fuerstenfeldbruck / Germany Phone +49 8141 53 50-0 Telefax +49 8141 53 50-190 This short version of the connecting and operating instructions is part of the delivery contents. PL NL ES IT FR ASM 23

FR IT ES NL PL The AS-i safety monitor is only suitable for use in electrical operating rooms / switch cabinets with minimum protection class IP54. The connection, commissioning and replacement of the AS-i safety monitor requires knowledge of the connecting and operating instructions as well as of the user manual for the asimon configuration and diagnostics software (see accessories order guide). Warning: Dangerous electrical voltage! May result in electrical shock and burns. Before beginning work, disconnect the system and device from voltage. Depending on the safety components selected for use, the complete safety system may be classified as belonging to a lower safety category! 24 ASM

1 Range of application Monitoring of safe AS-i slaves (e.g. emergency-shutdown switches) within an AS-i system as assigned with the ASiMon configuration software. Depending on the device variant, the second OSSD is available as safe AS-i output with or without relay. For full system expansion in protective operation, safe shutdown with a response time of maximum 40 ms. It is possible here to integrate up to 31 safe AS-i slaves. Mixed operation of standard and safe AS-i components is possible. Multiple AS-i safety monitors can be used within an AS-i system; if necessary, they can together monitor a safe AS-i slave. Approved for safety applications up to Category 4 acc. to ISO 13849-1 PLe. PL FR NL ES IT ASM 25

2 Dimensioned drawing FR IT ES NL PL 7,2 45 68,2 91,5 37x118 37x139 102 5 6 65 94 115 28,8 82,6 105,9 26 ASM

3 Specifications Electrical data Operating voltage U b 24V DC +/- 15% Residual ripple < 15% Rated operating current ASM1/1 and ASM1E/1: 150mA ASM1/2, ASM1E/2 and ASM2/1: 200mA ASM2E/2: 250mA Peak switch-on current All types: 600mA Reaction time <40ms (safety-relevant) Delay before start-up < 10s AS-interface data AS-i profile Monitor 7.F AS-i voltage range 18.5 31.6V AS-i current consumption < 45mA Mechanical data Dimensions (WxHxD) 45mm x 105mm x 120mm Housing material Polyamide PA 66 Weight ASM1/1 and ASM1E/1: approx. 350g ASM2E/1: approx. 420g ASM1/2, ASM1E/2 and ASM2E/2: approx. 450g Mounting Snap-on mounting on top-hat rail acc. to 50022 Connection 0, 8... 1,2 Nm 5... 6 mm / PZ2 10 7... 10.3 LB.IN 1 x (0,5... 4,0) mm² 2 x (0,5... 2,5) mm² 10 1 x (0,5... 2,5) mm² 2 x (0,5... 1,5) mm² AWG 2 x 20... 14 PL NL ES IT FR ASM 27

FR IT ES NL PL Configuration interface RS 232 Inputs and outputs "Start" input Input of "external device monitoring circuit" (EDM) Message output "safety on" Safety output Continuous thermal current (max.) Safeguarding Overvoltage category 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits Optical coupling input (high active), input current approx. 10mA at 24V DC Optical coupling input (high active), input current approx. 10mA at 24V DC PNP transistor output, 200mA, short-circuit and polarity-reversal protection Potential-free make contact, max. contact load: 1A DC-13 at 24V DC 3A AC-15 at 230V AC ASM/1, ASM1E/1 and ASM2E/1: max. total current for all output switching elements: 6A i.e. output circuit 1: 3A per output switching element ASM/2, ASM1E/2 and ASM2E/2: max. total current for all output switching elements: 8A i.e. output circuit 1: Environmental data Operating temperature -20 +60 C Storage temperature -30 +70 C Protection class IP 20 3A per output switching element output circuit 2: 1A per output switching element or output circuit 1: 2A per output switching element output circuit 2: 2A per output switching element External with max. 4A slow blow 3, for rated operating voltage 300V AC acc. to VDE 0110 part 1 28 ASM

Attention! Be certain to maintain the specified safeguards; only in this way is safe shutdown ensured in the case of failure. Attention! In addition to the system reaction time of max. 40ms, the reaction times of the safe AS-interface sensor slave, of the sensor being used for monitoring, of the safe AS-interface actuator slave and of the actuator used for this purpose must still be added. Please note that additional reaction times may likewise arise through the configuration of the safety monitor. The system reaction times of the daisy-chained AS-interface components are added up when coupling AS-interface networks. FR max. 1N PL NL ES IT ASM 29

4 Electrical installation FR IT ES NL PL Attention! Electrical installation may only be performed by trained specialist technicians. Attention! Each safe AS-interface slave is to be activated at least once per year and the switching behaviour of the output circuits of the AS-interface safety monitor visually inspected. After replacing a safe AS-i slave, the new slave must be checked for proper function; after replacing an AS-i safety monitor, the new AS-i safety monitor must be checked for proper function. Supply lines, signal lines and the AS-i bus line are to be laid separately from power supply lines. Suitable spark extinction must be used with contactors in the switch cabinet. For drive motors and brakes, observe the installation notices in the corresponding operating instructions. Maximum line length for the AS-i bus line is 100 m. For longer line lengths, use AS-i repeaters. Attention! The AS-interface power supply unit for supplying the AS-interface components must demonstrate safe mains separation acc. to IEC 60742 and the ability to bridge brief mains failures of up to 20ms. The power supply unit for 24 V supply must also demonstrate safe mains separation acc. to IEC 60742 and the ability to bridge brief mains failures of up to 20ms. 30 ASM

LED indicators ASM LED Colour Meaning AS-i 1 off no supply green, continuous AS-interface supply present AS-i 2 off normal operation red, continuous communication error AS-iS 1 off no supply green, continuous AS-interface supply present AS-iS 2 off normal operation red, continuous communication error 1 READY off (per output circuit) yellow, flashing external test necessary / acknowledge- yellow, continuous start-up/restart-disable active ment / delay before start-up active 2 ON (per output off contacts of the output switching element open circuit) green, continuous contacts of the output switching element closed green, flashing delay time runs in event of Stop Category 1 3 OFF/ FAULT off contacts of the output switching element closed (per output circuit) open red, continuous contacts of the output switching element red, flashing error on level of the monitored AS-interface components 1 READY 2 ON 3 OFF/ FAULT (per output circuit) simultaneously flashing rapidly internal device error, error message can be queried by means of asimon software PL NL ES IT FR ASM 31

FR IT ES NL PL Fig. 4.0-1: LED AS-i 1 LED AS-i 2 Output circuit 1 not used LED indicators in the device Terminal assignments of AS-i safety monitors ASM1/1 and ASM1E/1 Terminal Signal / description Electrical connection AS-i+ Connection to the AS-interface AS-i bus L+ +24V DC / supply voltage M GND / reference ground FE Functional earth 1.Y1 EDM 1 / input of external device monitoring circuit 1.Y2 Start 1 / start input 1.13 1) Output switching element 1 1.14 1) 1.23 Output switching element 2 1.24 1.32 Message output "safety on" 1) Safeguard according to technical data LED AS-i 1 (safe AS-i output) LED AS-i 2 (safe AS-i output) Output circuit 2 32 ASM

Terminal assignments of AS-i safety monitors ASM1/2 and ASM1E/2 Terminal Signal / description Electrical connection AS-i+ Connection to the AS-interface AS-i bus L+ +24V DC / supply voltage M GND / reference ground FE Functional earth 1.Y1 EDM 1 / input of external device monitoring circuit, output circuit 1 1.Y2 Start 1 / start input, output circuit 1 1) 1.13 Output switching element 1, 1.14 output circuit 1 1) 1.23 Output switching element 2, 1.24 output circuit 1 1.32 Message output 1 "Safety on", output circuit 1 2.Y1 EDM 2 / input of external device monitoring circuit, output circuit 2 2.Y2 Start 2 / start input, output circuit 2 2.13 1) Output switching element 1, output circuit 2 2.14 2.23 1) Output switching element 2, output circuit 2 2.24 2.32 Message output 2 "Safety on", output circuit 2 1) Safeguard according to technical data PL NL ES IT FR ASM 33

Terminal assignments of AS-i safety monitors ASM2E/1 and ASM2E/2 FR IT ES NL PL Terminal Signal / description Electrical connection AS-i+ Connection to the AS-interface AS-i bus AS-iS+ Safe AS-interface output for AS-iS actuator monitoring or coupling of another AS-interface network L+ +24V DC / supply voltage M GND / reference ground FE Functional earth 1.Y1 EDM 1 / input of external device monitoring circuit, output circuit 1 1.Y2 Start 1 / start input, output circuit 1 1) 1.13 Output switching element 1, 1.14 output circuit 1 1.23 1) Output switching element 2, 1.24 output circuit 1 1.32 Message output 1 "Safety on", output circuit 1 ONLY ASM2E/2: 2.Y1 EDM 2 / input of external device monitoring circuit, output circuit 2 2.Y2 Start 2 / start input, output circuit 2 2.13 1) Output switching element 1, 2.14 output circuit 2 (only ASM2E/2!) 2.23 1) Output switching element 2, output circuit 2 (ASM2E/2 only!) 2.24 2.32 Message output 2 "Safety on", output circuit 2 34 ASM

1) Safeguard according to technical data AS-i+ AS-i- FR IT ES PL NL Fig. 4.0-2: Connection for actuator monitoring AS-i network 1 Coupled AS-i network 2 AS-interface+ (brown) AS-interface- (blue) AS-interface+ (brown) AS-interface- (blue) Fig. 4.0-3: Coupling for AS-i networks ASM 35

5 Mounting FR IT ES NL PL Fig. 5.0-1: The safety monitor is mounted by clipping onto a standard 35 mm rail acc. to 50022. To remove, firmly press the monitor against the upper rail guide and lift out. C A D B Mounting the safety monitor A, B, C, D: To remove the encoded connection terminals, push back the safety spring a and pull the terminal away towards the front. When mounting, the connection terminal must audibly lock into place. 36 ASM

1. U = 0 V 2. a, b, c, d b c PL IT ES NL FR a d Fig. 5.0-2: Removing and mounting encoded connection terminals Mount cap and seal in steps 1-5. ASM 37

FR IT ES NL PL 1 a = Sealable cap for safeguarding against unauthorised adjustment and for ESD protection (part of the delivery contents). Fig. 5.0-3: Mounting and sealing the cap 2 3 4 C A D B 4 5 For further information, see the connecting and operating instructions for the AS-i safety monitor. 38 ASM

6 Replacing an AS-i safety monitor FR IT c + - 24 V DC a + - 24 V DC b 1 Disconnect the defective (a) AS-i safety monitor from the supply and connect the new monitor (b). a + - 24 V DC b 2 Connect the defective (a) and the new (b) AS-i safety monitor via the RJ45/RJ45 cable and press the service button (c) on the new (b) AS-i safety monitor. c ES a + - 24 V DC b 2 Disconnect the two AS-i safety monitors from one another and press the service button again. NL PL ASM 39

7 Order guides FR IT ES NL PL : Part No. Article Description 580020 ASM1/1 AS-i safety monitor, 1 OSSD 580021 ASM1/2 AS-i safety monitor, 2 OSSDs 580024 ASM1E/1 AS-i safety monitor, 1 OSSD; expanded functionality 580025 ASM1E/2 AS-i safety monitor, 2 OSSDs; expanded functionality 580028 ASM2E/1 AS-i safety monitor, 1 OSSD, 1 safe AS-i output, expanded functionality 580029 ASM2E/2 AS-i safety monitor, 2 OSSDs, 1 safe AS-i output, expanded functionality 580055 ASM1E-m/1 AS-i safety monitor, 1 OSSD expanded functionality, Muting 580056 ASM1E-m/2 AS-i safety monitor, 2 OSSDs, expanded functionality, Muting 580057 ASM2E-m/1 AS-i safety monitor, 1 OSSD, 1 safe AS-i output, expanded functionality, Muting 580058 ASM2E-m/2 AS-i safety monitor, 2 OSSDs, 1 safe AS-i output, expanded functionality, Muting 40 ASM

8 Order guides Accessories Part No. Article Description 580032 ASM-SWC ASM commissioning set for ASM1, ASM1E and ASM2E Contains: asimon configuration and diagnostics software, connecting and operating instructions, user manual for the software on CD, configuration cable, device-replacement data cable 50104078 ASM1-PK ASM1 configuration cable 50104079 ASM1-DK ASM1 device-replacement data cable PL NL ES IT FR ASM 41