Monitored econnect PDU

Similar documents
Monitored Pro econnect PDU

Switched econnect PDU

The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

POWER DISTRIBUTION UNITS (PDUs)

Frequently Asked Questions

Polar PDUs POWER MANAGEMENT

Data Center Solutions Brochure

Containment Accessories Floor Mounting Template

Key Elements of a Successful Data Center Cabinet Ecosystem

EF-Series EuroFrame Gen 2 Cabinet System

CPI Solutions. Protecting your technology investment.

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Models. Specifications

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Security Infrastructure Protection

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

econnect PDU Firmware Upgrader User Manual

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Data Center Airflow Management Basics: Comparing Containment Systems

CPI PowerScope User s Manual Version /

ipdu Pocket Guide NORTH AMERICA

Power Distribution Units for Data Centers

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Cabinet & Enclosure Systems

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

New G2 features allow for greater management of power and environment in IT racks

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

THE OFFICIAL TRADE JOURNAL OF BICSI

KVM SYSTEMS KVM SYSTEMS

Switched, Outlet Level Monitoring

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

ipdu Pocket Guide INTERNATIONAL

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

PE8216/PE8324. Energy Intelligence Solutions

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

ECO PDU. Features. PE5220sA

Setting new standards for reliable power distribution and metering

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

or

Junos WebApp Secure 5.0 Hardware Guide

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

Power Distribution. For technical support call Online catalog available at leviton.com 461

ipdu Pocket Guide INTERNATIONAL

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

Switched Rack Power Distribution Unit

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Configurable power distribution

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

PDU Inspired by Your Data Center. W IEC PDU Series

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

UPS Series. features: uninterruptible power supply. what great systems are built on.

ECO PDU PE7108/PE7208

All power outlet units include 10' power cords, mounting brackets, screws, unit packaging:

Power Distribution Units for Data Centers

QuickSpecs. HPE Rackmountable 3 Phase Uninterruptible Power Systems. Overview. (UPS R8000/3 and R12000/3)

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

PDU - Overview / Non-Intelligent PDU s

ECO PDU PE5108/PE5208

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

BCM2 Series Branch Circuit Monitors Quick Setup Guide

POWER CABLES FOR MISSION CRITICAL FACILITIES

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

MODEL NUMBER: B IP2

MODEL NUMBER: B IP4

* * Agilent Power Distribution Unit (PDU) Installation Guide

MODEL NUMBER: B IP2-K

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

Xcellis Workflow Extender (R520) Site Planning Guide

Server Technology Technical Data Sheet

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems. Overview

Managed Rack PDU MPH2 More efficient Simpler Better

Cisco Prisma II Platform

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

Transcription:

Protecting your technology investment. For use in data centers and equipment room racks and cabinets. Provides continuous, automated monitoring of each PDU to provide measurement at the rack level. Integration with electronic access control and environmental monitoring options provides a complete cabinet-level management solution that is easy to use and deploy. KEY FEATURES Withstands hot aisle temperatures of highdensity data center environments with an ambient temperature rating of 149 F (65 C) Protects equipment from current spikes and nuisance tripping with highly reliable, heat tolerant 100% rated magnetic hydraulic breakers Optimizes power usage in high-density applications with continuous power monitoring at each PDU and input branch circuit with +/-1% accuracy Delivers proactive environmental warnings and threshold alarms with integrated temperature and humidity monitoring Prevents accidental disconnections through optional locking outlets, which ensure straight cords stay securely fastened to IEC outlets Vertical PDUs support attachment of two electronic swinghandle locks to provide secure electronic access control for CPI GlobalFrame or TeraFrame cabinets Vertical PDU installs quickly with universal, tool-less mounting hardware or available shipped preinstalled in CPI cabinets Offers a broad range of standard configurations, combining different power inlets/plugs and outlets for configurations that match facility requirements. Vertical configurations feature up to 60 outlets. Vertical PDUs fit in the zero U space at the side of the cabinets and do not block the access to equipment mounting rails or exhaust airflow. SPECIFICATIONS Description: Use: Power Input: Power Output: Power Inlet/Plugs: Power Cord: Power Receptacles: Circuit Protection: Grounding/Bonding: Network/External Connections: Finish: Click Secure Technology 10 ADVANTAGES Secure Array Allows the use of a single IP address for up to 32 connected PDUs High Temperature Rating Designed to withstand ambient air temperatures up to 149 F (65 C) Preinstalled Option Eases installation and deployment within cabinets s Patented Click Secure s prevent accidental power loss Physical Security Integrates with econnect Electronic Access Control for physical security at the cabinet level Single-input, vertical and horizontal rack-mount PDUs For indoor use only, in environmentally controlled areas, may not be used outdoors or in harsh environments Specific to PDU, alternating current, 50/60 Hz (see ordering table) Stated as voltage range, maximum current, load and inlet/plug type Specific to PDU, limited by circuit breakers (see ordering table) NEMA or IEC power inlet/plug, specific to PDU (see order tables) Standard attached cord is 10'L (3 m) for vertical and horizontal PDUs, not rated for plenum use Order cord separately for models with IEC C20 inlet NEMA 5-20R, IEC C13 and/or IEC C19 s, specific to PDU (see order table) Includes power cord retention tethers to straight power cords at all non-locking outlets Optional Click Secure IEC s UL 489 listed, single-pole or two-pole, hydraulic-magnetic breakers to resist effects of high temperatures Low-profile design minimizes size of breaker boxes on PDUs and prevents accidental discharge Number and type specific to PDU (see table) All PDUs have a grounded power inlet/plug and an external ground connection with a threaded M5 attachment point Includes a grounding kit with a 12 L (300 mm), 12 AWG stranded copper wire jumper, and drop in attachment hardware for F-Series TeraFrame Gen 3 Cabinet, N-Series TeraFrame Gen 3 Cabinet or GF-Series GlobalFrame Gen 2 Cabinet (1) 10/100/1000 Mbps RJ-45 Ethernet connection (IPv4 and IPv6) (1) RJ11 Environmental Probe connection (1) RJ45 Serial/PDU In linking connection (RS-232); (1) RJ45 PDU Out linking connection (2) USB ports for firmware updates (2) Proprietary auxilary ports Black only Global Availability US & Canada +1-800-834-4969 Toronto, Ontario, Canada +905-850-7770 chatsworth.com techsupport@chatsworth.com Latin America +52-55-5203-7525 Toll Free within Mexico 01-800-01-7592 chatsworth.com.co Europe +44-1628-524-834 chatsworth.com Middle East & Africa Dubai, UAE +971-4-2602125 chatsworth.ae Asia Pacific +86 21 6880-0266 chatsworth.com.cn

SPECIFICATIONS Certifications: Internal Metering: Local Display: Network Monitoring: IP Consolidation (PDU Linking): Operating Conditions: Storage/Non-operating Conditions: Installation Hardware: Rack/Cabinet Mounting Brackets: UL, CSA C22.2 (Canada), CE (EU), FCC Part 15, Class A, EN 55022, RoHS Compliant Monitors unit voltage, current, power (kw), power factor and energy (kwh) at breaker, ±1% metering accuracy at each breaker Liquid Crystal Display (LCD) for easy viewing text rotation for viewing at any angle Allows initial setup of IP and subnet addresses without computer Displays total voltage, current and power on single-phase PDUs Displays total voltage, power and line input current on threephase PDUs Displays voltage, current, power and power factor for each breaker Displays temperature and humidity when optional environmental probe (P/N 11761-003) is attached to the PDU Displays alarm notifications Separate LED flashes red on alarm Monitor voltage, current, power (kw), power factor and energy (kwh) through 1 GB Ethernet interface using a web browser (HTTP or HTTPS), Telnet or an application that accepts alarms as SNMP v1, v2c or v3 traps Monitor temperature and humidity when external environmental probes (P/N 11761-003) are attached to the PDU Monitors door lock/unlock and open/closed status when econnect Electronic Access Control is connected Set and automatically monitor high and low alarm thresholds for power (excludes line input current), temperature and humidity Log data and events and receive alarm notifications by email Use the PDU In/Out connections to link up to 32 PDUs together using standard RJ45 Cat 5/6 patch cords View all connected PDUs through a single network connection and IP address Secure Array IP Consolidation: maintains downstream links even if one PDU loses power Supports a backup, second network connection through a user an alternate PDU Optional alarm notification if IP connection is lost or any of the PDU links are dropped Temperature: 32 F 149 F (0 C 65 C) at Input Power Rating (kw) Relative Humidity: 5% 95%, non-condensing Elevation: 0 10,000 feet (0 3,000 meters) Temperature: -13 F 149 F (-25 C 65 C) Relative Humidity: 5% 95%, non-condensing Elevation: 0 50,000 feet (0 15,000 m) Vertical PDUs include two tool-less mounting shoulder washers and installation hardware Vertical PDU washers can be installed spaced 64.75 (1645 mm) or 61.25 (1556 mm) apart to match most rack/cabinet mounting brackets Vertical PDU Washers can also be offset 2 (51 mm) to provide additional space at the top or bottom of the cabinet for the power cord in shorter cabinets Vertical PDUs can be installed with the inlet power cord near the top or bottom of the cabinet All horizontal PDUs include rack-mount brackets and mounting hardware for 19"EIA (486.2 mm) racks Horizontal PDUs can be installed with the inlet power cord near the left or right of the cabinet Mounting brackets and hardware included with horizontal models Not included with Vertical PDU, order separately Vertical Mounting Brackets included with most CPI Cabinets, check cabinet specifications Design ' (CPI) Monitored econnect Power Distribution Units (PDU) provide reliable power distribution for evolving enterprise data centers, whether connecting a few pieces of equipment, or supporting high-density computing. Monitored PDUs include features that enable the monitoring of voltage, current, power (kw) and energy (kilowatt-hour) levels with a ±1% metering accuracy for each PDU in the data center. Each Monitored econnect PDU features a central LCD display, which provides detailed power usage information for all attached equipment. Additionally, each PDU comes with the capability for remote monitoring and includes a web-based interface that provides users with the ability to monitor power usage and environmental factors affecting each PDU in the data center, as well as allows users to navigate between linked deployments. The PDU includes firmware, which allows users to set threshold alarms for power, temperature and humidity limits, forwarding alarm notifications to users via email and continuously logging environmental data and events. Large deployments of Monitored econnect PDU can also be managed through Power IQ for econnect or other third party software that accepts SNMP traps. Ease of Deployment Each PDU has a built-in Ethernet connection, one external connection for two environmental probes, two connections for linking PDUs together and two connections for linking two electronic locks on the front and rear of the cabinet. CPI s Secure Array IP Consolidation allows the use of a single IP address for up to 32 connected PDUs, significantly reducing operating costs. In addition, CPI s Secure Array IP Consolidation provides failover and pass-through capability for an entire array of connected PDUs. This ensures that functioning PDUs will continue to communicate in the event that a PDU in the array loses connectivity. Elevated hot aisle data center temperatures will not affect econnect PDUs, which have been designed to withstand ambient air temperatures up to 149 F (65 C). Vertical econnect PDUs with IEC outlets are available with Click Secure s, which prevent accidental disconnections. This patented feature securely fastens standard straight cords to the PDU, protecting your power from sudden disruptions. PDUs without locking outlets are also available. econnect PDUs are suitable for global use. Most PDUs include an attached 10 L (3 m) power cord with an IEC or NEMA style plug rated for 100-125 Volt, 200-240 Volt or 380-415 Volt input, and some models have an IEC C20 inlet, allowing the power cords to be ordered separately to match specific site requirements. See reverse for product selection, or contact CPI Technical Support for configuration assistance. COMPATIBLE WITH CPI Cabinet Systems CPI Rack Systems econnect Electronic Access Control Temperature and Humidity Sensors RELATED PRODUCTS Input Power Cords Mounting Brackets Power IQ for econnect Software 2

ORDERING INFORMATION Monitored Vertical econnect PDUs Part Number Input Output Dimensions - in (mm) Standard Amp kw* Plug Breakers (Hydraulic Magnetic) 100-240 Volt, Single-Phase Input - Worldwide s H*** W D L3-1A1E3 P3-1A1E3 16/20 1 3.6 C20 Inlet** 1 x 2P 20A (24) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) 120 Volt, Single-Phase Input - North America Models N/A P3-1A1A5 20 1.9 C20 Inlet** 1 x 2P 20A (24) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1C0A5 20 1.9 L5-20P 1 x 2P 20A (24) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1A1B5 20 1.9 C20 Inlet** 1 x 2P 20A (36) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1C0B5 20 1.9 L5-20P 1 x 2P 20A (36) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1D0A5 30 2.8 L5-30P 2 x 2P 20A (24) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1D0B5 30 2.8 L5-30P 2 x 2P 20A (36) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) 120-208 Volt, Single-Phase Input - North America Models N/A P3-1J0K4 20 3.3 L14-20P 1 x 2P 20A (24) C13, (6) C19, (6) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) L3-1K0K4 P3-1K0K4 30 4.9 L14-30P 2 x 2P 20A (24) C13, (6) C19, (6) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) 208 Volt, Single-Phase Input - North America Models L3-1E0E3 P3-1E0E3 20 3.3 L6-20P 1 x 2P 20A (24) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1F0B1 P3-1F0B1 30 4.9 L6-30P 2 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) L3-1F0E3 P3-1F0E3 30 4.9 L6-30P 2 x 2P 20A (24) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1F0G3 P3-1F0G3 30 4.9 L6-30P 2 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) 120/208 Volt, Three-Phase Input - North America Models L3-1N0B1 P3-1N0B1 20 5.7 L21-20P 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1N0B5 20 5.7 L21-20P 3 x 2P 20A (36) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) L3-1N0G3 P3-1N0G3 20 5.7 L21-20P 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1N0K4 P3-1N0K4 20 5.7 L21-20P 3 x 2P 20A (24) C13, (6) C19, (6) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1N0L4 20 5.7 L21-20P 3 x 2P 20A (24) C13, (9) C19, (3) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) L3-1P0B1 P3-1P0B1 30 8.6 L21-30P 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1P0B5 30 5.7 L21-30P 3 x 2P 20A (36) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) L3-1P0F3 P3-1P0F3 30 8.6 L21-30P 3 x 2P 20A (24) C13, (12) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1P0G3 P3-1P0G3 30 8.6 L21-30P 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1P0K4 P3-1P0K4 30 8.6 L21-30P 3 x 2P 20A (24) C13, (6) C19, (6) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1P0L4 30 8.6 L21-30P 3 x 2P 20A (24) C13, (9) C19, (3) 5-20R 70.5 (1791) 2.2 (56) 2.2 (56) 208 Volt, Three-Phase Input- North America Models N/A P3-1L0B1 20 5.7 L15-20P 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1L0G3 20 5.7 L15-20P 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1M0B1 P3-1M0B1 30 8.6 L15-30P 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) L3-1M0F3 P3-1M0F3 30 8.6 L15-30P 3 x 2P 20A (24) C13, (12) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1M0G3 P3-1M0G3 30 8.6 L15-30P 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1T0B1 P3-1T0B1 50 9.9 CS8365C 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) L3-1T0F3 P3-1T0F3 50 9.9 CS8365C 3 x 2P 20A (24) C13, (12) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1T0G3 P3-1T0G3 50 9.9 CS8365C 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-3U0H3 P3-3U0H3 50 14.3 CS8365C 6 x 2P 20A (36) C13, (6) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3UOV3 P3-3UOV3 50 14.3 CS8365C 6 x 2P 20A (12) C13, (18) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3U041 N/A 50 14.3 CS8365C 6 x 2P 20A (60) C13 77.9 (1978) 2.7 (68) 2.2 (56) L3-3UOF3 N/A 50 14.3 CS8365C 6 x 2P 20A (24) C13, (12) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3VOF3 N/A 60 17.2 IEC 60A 3P+E 6 x 2P 20A (24) C13, (12) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3VOH3 P3-3VOH3 60 17.2 IEC 60A 3P+E 6 x 2P 20A (36) C13, (6) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3V0V3 P3-3V0V3 60 17.2 IEC 60A 3P+E 6 x 2P 20A (12) C13, (18) C19 75.0 (1905) 2.7 (69) 2.2 (56) L3-3V041 N/A 50 17.2 IEC 60A 3P+E 6 x 2P 20A (60) C13 77.9 (1978) 2.7 (68) 2.2 (56) Notes: See Next Page. For detailed, model-specific dimensions and technical specification information, download the cut sheet for your selected PDU part number by entering it into the CPI website search field at the top right corner of our website: www.chatsworth.com. 3

ORDERING INFORMATION Monitored Vertical econnect PDUs Part Number Input Output Dimensions - in (mm) Standard Amp kw* Plug Breakers (Hydraulic Magnetic) 240/415 Volt, Three-Phase Input - North America Models Monitored Vertical econnect PDUs - Outside North America 220-240 Volt, Single-Phase Input L3-1G0E3 P3-1G0E3 16 3.6 IEC 16A 1P+N+E 1 x 2P 16A (24) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1H0E3 P3-1H0E3 32 7.3 IEC 32A 1P+N+E 2 x 2P 16A (24) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1H0G3 P3-1H0G3 32 7.3 IEC 32A 1P+N+E 2 x 2P 16A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1H0B1 P3-1H0B1 32 7.3 IEC 32A 1P+N+E 2 x 2P 16A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) 220-240/380-415 Volt, Three-Phase Input s H*** W D N/A P3-1Q0B1 20 11.4 L22-20P 3 x 2P 20A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1Q0F3 20 11.4 L22-20P 3 x 2P 20A (24) C13, (12) C19 70.5 (1791) 2.2 (56) 2.2 (56) N/A P3-1Q0G3 20 11.4 L22-20P 3 x 2P 20A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-2R0F3 P3-2R0F3 30 17.2 L22-30P 6 x 1P 20A (24) C13, (12) C19 72.0 (1829) 2.35 (60) 2.2 (56) L3-2R0H3 P3-2R0H3 30 17.2 L22-30P 6 x 1P 20A (36) C13, (6) C19 72.0 (1829) 2.35 (60) 2.2 (56) L3-2R041 N/A 30 17.2 L22-30P 6 x 1P 20A (60) C13 77.9 (1978) 2.7 (68) 2.2 (56) L3-1W0B1 P3-1W0B1 16 11 IEC 16A 3P+N+E 3 x 2P 16A (36) C13 70.5 (1791) 2.2 (56) 2.2 (56) L3-1W0F3 P3-1W0F3 16 11 IEC 16A 3P+N+E 3 x 2P 16A (24) C13, (12) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-1W0G3 P3-1W0G3 16 11 IEC 16A 3P+N+E 3 x 2P 16A (30) C13, (6) C19 70.5 (1791) 2.2 (56) 2.2 (56) L3-2Y0F3 P3-2Y0F3 32 22.1 IEC 32A 3P+N+E 6 x 1P 16A (24) C13, (12) C19 72.0 (1829) 2.35 (60) 2.2 (56) L3-2Y0H3 P3-2Y0H3 32 22.1 IEC 32A 3P+N+E 6 x 1P 16A (36) C13, (6) C19 72.0 (1829) 2.35 (60) 2.2 (56) L3-2Y041 N/A 32 22.1 IEC 32A 3P+N+E 6 x 1P 16A (60) C13 77.9 (1978) 2.7 (68) 2.2 (56) Notes: Order mounting brackets separately. On single-phase PDUs, output voltage equals input voltage. On three-phase PDUs, 208 VAC nominal output through C13 and C19 outlets; 120 VAC nominal output through NEMA 5-20R outlets. 1 Amperage: 20A within North America and 16A Outside of North America. * For kw column, all values are derated calculations per UL for use in North America. The Input Amp column lists the maximum rated value of the input plug/inlet and circuit breaker rating. UL/NEC regulatory code requires current ratings on product labels to be derated to 80% of the maximum rated values (for example: 20 Amp = 16 Amp on UL product label). For the Input kw column, all values are derated calculations per UL for use in North America. ** Order power cord separately for PDUs with C20 input. **** PDUs that are 72 H (1829 mm) must be placed in 44U or taller CPI cabinets. PDUs that are 75 H (1905 mm) or 77.9"H (1978 mm) must be placed in 45U or taller CPI cabinets. **** Capacity when used at 230V with a 16A power cord. Actual capacity will vary if connected to lower voltage or to a lower amperage input plug. Capacity when used at a Nominal voltage of 230V. Capacity when used at a Nominal voltage of 230V/415V 3-Phase. Monitored Horizontal econnect PDUs Part Number Input Output Dimensions - in (mm) Standard Amp kw* Plug Breakers (Hydraulic Magnetic) 100-240 Volt, Single-Phase - Worldwide s H*** W D N/A P3-5A1W1 16 3.6**** C20 Inlet** 1 x 2P 16A (12) C13 2U 19"EIA (486.2) 10.1 (257) 120 Volt, Single-Phase Input - North America Models N/A P3-5C0W5 20 1.9 L5-20P 1 x 2P 20A (12) 5-20R 2U 19"EIA (486.2) 10.1 (257) N/A P3-5D0W5 30 2.8 L5-30P 2 x 2P 20A (12) 5-20R 2U 19"EIA (486.2) 10.1 (257) 208 Volt, Single-Phase - North America Models N/A P3-5E1W1 20 3.3 L6-20P 1 x 2P 16A (12) C13 2U 19"EIA (486.2) 10.1 (257) N/A P3-5F0Y3 30 4.9 L6-30P 2 x 2P 20A (8) C13, (4) C19 2U 19"EIA (486.2) 10.1 (257) N/A P3-5F0W1 30 4.9 L6-30P 2 x 2P 20A (12) C13 2U 19"EIA (486.2) 10.1 (257) Monitored Horizontal econnect PDUs - Outside North America 220-240 Volt, Single-Phase - Outside North America N/A P3-5H0W1 32 7.3 IEC 32A 1P+N+E 2 x 2P 16A (12) C13 2U 19"EIA (486.2) 10.1 (257) N/A P3-5H0Y3 32 7.3 IEC 32A 1P+N+E 2 x 2P 16A (8) C13, (4) C19 2U 19"EIA (486.2) 10.1 (257) *Notes: Horizontal PDUs that are 2U, 19 EIA are 3.5 H (89 mm) and 17 W (432 mm). Mounting Brackets are included. * For kw column, all values are derated calculations per UL for use in North America. The Input Amp column lists the maximum rated value of the input plug/inlet and circuit breaker rating. UL/NEC regulatory code requires current ratings on product labels to be derated to 80% of the maximum rated values (for example: 20 Amp = 16 Amp on UL product label). For the Input kw column, all values are derated calculations per UL for use in North America. ** Order power cord separately for PDUs with C20 input. **** Capacity when used at 230V with a 16A power cord. Actual capacity will vary if connected to lower voltage or to a lower amperage input plug. Capacity when used at a Nominal voltage of 230V. 4

ACCESSORIES POWER CORD PLUG TABLE: NEMA L5-15P NEMA L5-20P (Single-Phase) Straight Plugs IEC Plugs IEC 16A 1P+N+E 110-125VAC/15A NEMA 5-15P 110-125VAC/15A EC 60320 C-19/C-20 110-240VAC/20A 17761-002 IEC C20 PDU Input Power Cords Use Input power cords with econnect PDUs that have IEC C20 inlets. Select power cord to match power connection in the facility IEC C19 Connector attaches to the C20 Inlet on the PDU Sold individually, order one power cord per PDU 110-125VAC/20A NEMA 5-20P 110-125VAC/20A IEC 16A 1P+N+E 200-240 VAC/16A NEMA L6-15P 200-240VAC/15A NEMA 6-15P 200-240VAC/15A NEMA L6-20P 200-240VAC/20A NEMA 6-20P 200-240VAC/20A Environmental Probe with Temperature and Humidity Sensor Monitored econnect PDUs include a single external connection that can attach up to two Environmental Probes using a splitter. When attached, the PDU will report temperature and humidity measurements for each probe on the local display and remotely through the built-in web interface. Sold individually or in a kit with two probes and a splitter Each probe is a combination temperature and humidity sensor with attached 6'L (1.8 m) cord, allowing the sensor to be positioned appropriately within the cabinet Part Number 17763-001 17763-002 17763-003 17763-004 17763-005 17763-006 17763-007 17763-008 17763-009 17763-010 17761-003 17761-001 econnect PDU Accessories Description PDU Input Power Cord, 110-125 VAC or 200-240 VAC, IEC C19 Connector to IEC C20 Plug, 10 L (3 m) IEC C19 Connector to NEMA 5-15P Plug, 8 2 L (2.4 m) IEC C19 Connector to NEMA 5-20P Plug, 8 2 L (2.4 m) IEC C19 Connector to NEMA 6-15P Plug, 8 2 L (2.4 m) IEC C19 Connector to NEMA 6-20P Plug, 8 2 L (2.4 m) IEC C19 Connector to NEMA L5-15P Plug, 10 L (3 m) IEC C19 Connector to NEMA L5-20P Plug, 10 L (3 m) IEC C19 Connector to NEMA L6-15P Plug, 10 L (3 m) IEC C19 Connector to NEMA L6-20P Plug, 10 L (3 m) IEC C19 Connector to IEC 16A 2P+E Plug, 10 L (3 m) (2) Environmental Probes with (1) Temperature and (1) Humidity Sensor Kit with splitter 72"L (1828 mm) x 2 H (50 mm) x 2 W (50 mm) Environmental Probe with (1) Temperature and (1) Humidity Sensor 72"L (1828 mm) x 1 H (25 mm) x 1 W (25 mm) Shipping Weight lb (kg) Environmental Probe Splitter 6 L 17761-002 (152 mm) x 2 H (50 mm) x 2 W (50 mm) Note: Splitter is required when attaching two probes together. 17763-xxx would be used in conjunction with L2-1A1E3. 17762-003 17762-002 39110-C01 13780-C01 Part Number Additional Accessories Description Shipping Weight lb (kg) 17762-003 Cord Retention Tethers, Pack of 50 17762-002 Ground Wire Kit 17762-001 Tool-less Mounting Hardware Kit, Pack of 2 39110-C01 13780-C01 25140-701 13762-701 Mounting Bracket Kit for F-Series TeraFrame Gen 3 Cabinet or GF-Series GlobalFrame Gen 2 Cabinet System Mounting Bracket Kit for F-Series TeraFrame Gen 2 Cabinet System Mounting Bracket Kit for GF-Series GlobalFrame Gen 1 Cabinet System Mounting Bracket Kit for M-Series MegaFrame Cabinet or C-Series SlimFrame Cabinet System 35700-701 Mounting Bracket Kit for Rack Systems Note: Each PDU includes Cord Retention Tethers, Ground Wire Kit and Tool-less Mounting Hardware. They are listed as Service Parts. Mounting Brackets are included with CPI Cabinet Systems. 25140-701 13762-701 5

PRODUCT DATA SHEET Monitored econnect PDU ORDERING INFORMATION PLUG/INLET TABLE: POWER RECEPTACLE/OUTLET TABLE Single-Phase/ Receptacles/ s NEMA L5-20P 110-125 VAC/20A NEMA L5-30P 110-125 VAC/30A NEMA L14-20P 120/240 VAC/20A NEMA L14-30P 120/240 VAC/30A NEMA L15-20P 208 VAC/20A IEC C20 110/125 VAC/20A NEMA 5-20R 120 VAC/20A NEMA L6-20P 200-240 VAC/20A NEMA L6-30P 200-240 VAC/30A NEMA L15-30P 208 VAC/30A NEMA L21-20P 120/208 VAC/20A NEMA L21-30P 120/208 VAC/30A NEMA L22-20P 380/415 VAC/20A NEMA L22-30P 380/415 VAC/30A IEC C20 200/240 VAC/20A IEC 16A 1P+N+E 200/240 VAC/16A IEC 32A 1P+N+E 200/240 VAC/32A IEC 16A 3P+N+E 230/400 VAC/16A IEC 32A 3P+N+E 230/400 VAC/32A IEC C19 IEC C13 UL: 120/208VAC/15A UL: 120/208VAC/20A CE: 208VAC/16A CE: 208VAC/10A Split-Phase/ Three-Phase/ 50A CS8365C 208 VAC/50A* Power Inlet Universal/ * Note: 50A CS8365C is rated for 50A, but maximum input is 35A on three breaker PDUs. POWER MANAGEMENT, ENVIRONMENTAL MONITORING AND PHYSICAL SECURITY INTEGRATION econnect Electronic Access Controls (EAC) Integrate power management, environmental monitoring and cabinet access control under a single network connection, one user interface and one user database for dramatically reduced deployment savings. Fully compatible with DCIM software. Available on vertical Monitored, Monitored Pro, Switched and Switched Pro econnect PDUs. Shipping Weight lb (kg) Part Number Description 36650-001 econnect EAC Smart Card Kit 36652-001 econnect EAC Sensor Kit 36651-001 econnect EAC Wire Harness Kit 36653-001 RF IDeas EAC Smart Card Reader 36654-001 econnect EAC Smart Cards power Order Locks and PDUs preinstalled to your cabinet. Add power. Make it easy. Simplify ordering, shipping and installation by requesting econnect PDUs and econnect EAC to be installed in CPI's GF-Series GlobalFrame or F-Series TeraFrame Cabinets before they leave the factory. Go to the Product Configurator to configure a cabinet with locks and PDUs preinstalled. CPI now offers Extended Limited Warranties on CPI-Branded Electronic products, available for two additional years beyond the expiration of the Original Warranty Period (3 years). Interested in learning more about our Power Products? Call us at 800-834-4969, or email Technical Support at techsupport@chatsworth.com. Contact CPI Customer Service, or visit www.chatsworth.com/warranty for more information. While every effort has been made to ensure the accuracy of all information, CPI does not accept liability for any errors or omissions and reserves the right to change information and descriptions of listed services and products. 2017, Inc. All rights reserved., CPI, CPI Passive Cooling, econnect, RMR, MegaFrame, Saf-T-Grip, SeismicFrame, SlimFrame, TeraFrame, GlobalFrame, CUBE-iT PLUS, Evolution, OnTrac, QuadraRack and Velocity are federally registered trademarks of. Simply Efficient, Secure Array, EuroFrame, Clik-Nut and Motive are trademarks of. All other trademarks belong to their respective companies. Rev.12 05/17 MKT-60020-543