Crane Control Class 9004

Similar documents
Crane Control Contactors and Relays

Versatile Safety Interlock Switch with Guard Door Locking

920 Remote Control (RC) Switches

CS7 Industrial Control Relays

PENDANT PUSHBUTTON STATIONS

3RA13, 3RA14 Contactor Assemblies

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

ELECTRICAL CONTROL SYSTEM COMPONENTS

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Large DIspLay process Meters

ASCO 920 Remote Control (RC) Switches

Mini Contactors & Overloads

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27

The OHMIC RESISTORS Pty. Ltd.

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Digital Keypad Introduction

Magnetically Actuated Safety Interlock Switches

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Controls Enclosed Non-Combination Starters - PESW Series

Safety Mats & Area Guarding

DUCT-O-WIRE. Enclosed Pendant Push Button Stations CAUTION

NPA Pendant Control Station

Data Sheet. JS6000 Joystick Base

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

PGR-2601 MANUAL DC GROUND-FAULT RELAY

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Safety Monitoring Relays

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Installation Instructions for DeviceNet E50 Limit Switches

Description Page Number PM AC Relays PM DC Relays

Product Manual Pushbutton Station for Modicon Programmable Controller MODBUS Interface

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

SMARTSTART MOTOR STARTERS

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Allen-Bradley Drives

CS7 Industrial Control Relays

Voltage Sag Simulator

Jockey Pump Controllers

N2S and N2SC Series Control Stations

Model Number Structure

Jockey Pump Controllers

Safety Interlock Switches

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

60103 Circuit Breaker

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

Push Button & Selector Switch Components. Operator Protective Boots EXPLOSIONPROOF AUXILIARY DEVICES EXPLOSIONPRROOF AUXILIARY DEVICES

Quick Start Guide TS A

Smartstart Control Module

Limit Switches E47 Precision Switches

PS-4100 POWER SUPPLY MANUAL

DC-Switch With G20S/G20. next

SECTION WIRING DEVICES

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Installation, Operation

EJB Junction Boxes Dimensions Pg. 132

Machine Safety. Products

PGM-8325 MANUAL NEUTRAL GROUNDING MONITOR

Analog Voltage Combination Module

PLC Racks IC697CHS782/783

CS8 Industrial Control Relays

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

RT300 Series Crane & Hoist Joystick. RunnTech. Potentiometer: ±32, Hall sensor: ±20

File E60693 Project 08CA REPORT. COMPONENT - Terminal Blocks. Weidmueller Interface GmbH & Co. KG Detmold.

NETRONICS HS3500 CONTROLLER

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Tachometer Panel, PE3

Micro Contactor MA Series

Plastic Cylindrical Inductive Prox

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

the Interactive Catalog

ControlMaster. Crane Inverter Control Systems. Innovation... Performance... Reliability.

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

onlinecomponents.com

WMS SUPPLEMENTARY PROTECTORS

Series CA7 Contactors

ORDER GUIDES WITH STEEL ROD ACTUATORS WITH HIGH STRENGTH THERMOPLASTIC ROD ACTUATORS*

Z1 axis pot. (Rocker pot.) side operation. SW1 (ON when pushed)

PRODUCT SPECIFICATION. PC Board Relays. Series.

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

37.3. Pushbuttons and Indicating Lights. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description

Owner s Manual SGA 100 And SGA 100C NOTE NOTE. 1. Safety Symbol Definitions. 2. Weld Control Specifications. 3. Duty Cycle

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Single Phase Systems-North American PC125/PC420 Series

Model Number Structure

ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

current sensing relays

80 Series Push Button Pendant Features

Solid-State Counter/Timer

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

For information on combinations, refer to Ordering Information. (2) Contacts

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Transcription:

Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................ 141 Pendant Push Button Station......................................... 143

Master Switches PRICING AND ORDERING INFORMATION The standard master switch is supplied with a standard operating handle arranged for right hand operation. VM Master Switch Maximum Number of Circuits Including Off-Position Reset 9 Number of Speed Points Each Direction Open type General Purpose Enclosure NEMA Type 1 Type Price Type Price VO9 4122. VG9 4758. 12 1-6 VO12 4758. VG12 5550. 16 VO16 7414. VG16 8638. CM Master Switch Class 9004 Type VG12 Master Switch Maximum Number of Circuits Including Off-Position Reset 8 Number of Speed Points Each Direction General Purpose Enclosure NEMA Type 1 Type Price CG8 5460. 12 2-6 CG12 6426. 16 CG16 9330. Control Type Identification Controller Control Class Class and Type of Control Type Description Contactor Used 6121 Hoist W 7004 M 6121 Travel U 6131 Hoist Y or W 7004 M 6131 Travel Z or U Class 9004 Type CG12 Master Switch For standard control scheme. Modifications Description Optional Feature Price addition Form Letter VM CM Left hand operation L N.C. N.C. Spring return to off point S 1014. 1044. Push button in handle N.O. contact (reduce the number of circuits available by one) B 1656. 1656. Off point mechanical latch O 1446.... Short 24 in high enclosure E N.C.... Application Data Contact Ratings VDC DC Amperes AC Amperes VAC Continuous Interrupting Inrush Continuous Interrupting 115 15 1.5 120 30 15 10 230 15 0.9 How to Order: Example To Order Specify: Catalog Number Example Class Number Class Type Form(s) Type Number Form(s) 9004 VG12W5 S Consists of master switch type, control type identification and the number of speed points. Ordering Information Required: 1. Class 2. Type 3. Form 4. If for use with controller other than Square D, specify number of speed points and contact arrangement in addition to Class and Type numbers. 140 2003 The Electric Controller & Mfg. Co., LLC 01/17

Master Switches ORDERING INFORMATION (CIRCLE ONE) REVERSE OR HOIST (CIRCLE ONE) FORWARD OR LOWER 6 5 4 3 2 1 OFF 1 2 3 4 5 6 APPROXIMATE DIMENSIONS AND WEIGHTS CM Master Switch Lower Forward Max. Throw Hoist Reverse 1.0 25 Std. Ball Handle 2.38 60 Y 1.06 26.9 To back Y edge 5.38 5.38 137 137 Spring return mechanism 5.9 150 16.06 408 26.0 660 To remove cover vertically 18.125 460.4 to base line 4.44 113 Push button handle 1.5 38 X 1.25 32 Tapped for 1.5 conduit 38 14.38 365 16.38 416 Tapped and plugged for 1.25" conduit 5.25 5.25 133 133 Three 0.56 14 Dia. Mtg. holes 0.63 16 4.38 111 1.0 25 2.06 52 X Type X Y CG8 CG12 CG16 6.187 157 7.31 186 8.44 214 7.0 178 8.125 206 9.25 235 Net weight lbs (kg) 58 (26.1) 63 (28.4 70 (31.5) Add 1.37" (35) to "Y" dimension for Master Switch with Off-point latch handle. Dual Dimensions Max. no. of Speed points in each direction 1-2 3 4 5 6 inches mm Max. throw 6.5 165 8.44 214 10.38 264 12. 310 13.5 343 01/17 2003 The Electric Controller & Mfg. Co., LLC 141

Master Switches APPROXIMATE DIMENSIONS AND WEIGHTS VM Master Switch Open Switch Max. Throw Enclosed Switch Max. Throw 10.20 259 B 4 Mtg. holes For 1/4" F.H. screws 0.50 12 2.50 63 (Top view) CL 6.50 165 5.5 139 5.62 142 5.00 127 1 0.56 14 0.44 11 3.80 96 Lower forward 6.13 155 6.50 165 Hoist reverse 0.81 21 7.13 181 0. 5 C L 1.88 47 To remove Removable cover Lower forward 9.35 237 Hoist reverse 8.50 216 0.66 16.40 10 9.65 245 30.32 770 4 Mtg. holes 2 40.0 1016 1.25 32 Minimum electrical clearance (Bottom view) 4.25 106 5.62 142 Terminals 6.00 152 11.44 291 Pushbutton Handle 10.45 265 5.00 127 30 4.12 104 Dashed line represents 5" x 6" cutout in bench board up to.25" thick. The switch must be turned approximately 30 during withdrawal through cutout for clearance of lower part. Mounting straps may be turned at right angle to position shown. Master switches are shown for right hand operation. For left hand operation, the orientation of handle and gear box is reversed. Open Master Switch + Add 1.38 in (35 mm) to B dimension for master switch with spring return. Enclosed Master Switch Type B+ (in/mm) Net Weight, lbs (kg) Type Net Weight, lbs (kg) VO9 15.25 (387) (8.6) VG9 53 (24.1) VO12 18.63 (473) 22 (10) VG12 56 (25.5) VO16 23.13(587) 25 (11.4) VG16 59 (26.8) Maximum Number of Speed Points In Each Direction Maximum Throw (in/mm) 1 3.5 (89) 2 7.88 (200) 3 10.00 (254) 4 11.75 (298) 5 13.25 (337) 6 14.25 (362) Dual Dimensions inches mm 142 2003 The Electric Controller & Mfg. Co., LLC 01/17

Pendant Push Button PRICING AND APPLICATION DATA Each station consists of: 1 Pilot light 1 Momentary contact start/reset button 1 Momentary contact stop button 2 Mechanically interlocked speed control push buttons for each crane motion (Standard position of push buttons for each crane motion from top to bottom is as follows: Bridge Forward, Reverse; Trolley Forward, Reverse; Hoist Up, Down) Number of Stepped Crane Motions Type Price Type Price 3 PBC3 & WPBC3 & 4 PBC4 & WPBC4 & 5 PBC5 & WPBC5 & Consult factory for delivery. Application Data Controller Modifications General Purpose Enclosure NEMA Type 1 Outdoor Enclosure NEMA Type 3R Class 9999 Type AI arc suppressors may be required. The contactor coil current ratings should be checked against the contact ratings shown in the table below. Contact Ratings VAC AC Amperes Interrupting 120 3.0 5 amperes continuous VDC DC Amperes Interrupting 125 1.1 250 0.55 Class 9004 Type PBC3 Pendant Push Button Station Push Button Selection Data Each set of speed control push buttons for each crane motion will control up to 5 speed points and 7 circuits in each direction. 01/17 2003 The Electric Controller & Mfg. Co., LLC 143

Pendant Push Button APPROXIMATE DIMENSIONS AND WEIGHTS 3/8" Cable Suspension Holes A Type A B C D PBC3 PBC4 PBC5 WPBC3 WPBC4 WPBC5 Front B Max Front 25.6 650 30.1 765 34.8 884 22.3 566 26.3 668 32.0 813 D Side C 3.1 79 3.1 79 3.1 79 Dual Dimensions 3.4 86 3.4 86 3.4 86 inches mm 0.5 13 0.5 13 0.5 13 Net Weight lbs (kg) 12 (5.4) 15 (6.8) 17 (7.7) (8.6) 24 (10.8) 29 (13.1) Ordering Information Required: 1. Class 2. Type 3. Indicate the number of speed points for each crane motion. 4. If push button station is for use with existing or new Square D panels give wiring diagram number and/or Class and Type number of controller. If push button station is for use with other than Square D controller, supply elementary wiring diagram for each function it controls. 5. Specify position of speed control push buttons for each motion if order required is different than standard. 144 2003 The Electric Controller & Mfg. Co., LLC 01/17