Analog Output Isolators

Similar documents
Solenoid Driver/Discrete Output Isolators

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

APPLICATION GUIDE. Interface Modules IM Series.

Temperature Converters

Inductive sensor with analog output BI15-M30-LI-EXI

Intrinsic Safety Control Drawing

Intrinsically Safe Barriers

Your Global Automation Partner. IM Interface Technology in Modular Housings

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Level gauges Series LS Level indicator, switch and transmitter for liquids

Backplane. Allen-Bradley. System integration. Backplane

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Technical specification

02/11/2015

Safety manual. This safety manual is valid for the following product versions: Version No. V1R0

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Backplane. System integration. Backplane

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Intrinsically Safe Remote I/O System

M-series Intrinsically Safe I/O

Sensors with analog output

Installation & Operation Manual

MODEL 9250 Preliminary data sheet

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

HART adapters. Data Sheet. HART FSK/PC modem USB Ex(Haz.) and Non-Ex(Haz.) applications

PR - PCB relay. 42 catalog 2002 e / the PR-PCB relay. By using best materials and because of the simple construction the highest failsecurity

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

How to calculate an Intrinsically Safe loop approval.

BMX DDM Mixed Relay Input/Output module

Amplifiers, Counters, Timers & Controls

Installation & Operation Manual

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Introduction to Fieldbus Foundation Physical Layer

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

FCS PROBE FLOW MONITOR PRODUCT OVERVIEW

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

HART Modem for USB. Features. Description. Datasheet HmUSB-01 December Ideal for configurations, data acquisition and digital control.

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

IHP24. Intelligent Hydraulic Positioner D HP- PL

the Interactive Catalog

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

The information in this chapter will enable you to:

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

Backplane. System integration. Backplane

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

Process displays For current and voltage

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Tachometer Panel, PE3

ALTERNATING RELAYS & CONTROLLERS ARM Series

General Specifications

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

MDA-8000 DIO User Manual

Advantages of a Full Featured 700 Series Relay

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Intrinsically Safe Temperature Concentrator System

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

TEC Controller Extended I/O Application 2497 with Slave Mode Application Application Note Building Technologies

Microcontroller Based Temperature/Process Scanner (Product Code 7.4 to 7.6) MSI-804 with 16 relays

AI-917-A0. Analogue Input Module (4x 0-20 ma)

Digital Indicator Solutions

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Digital electropneumatic Positioner for the integrated mounting on process control valves

Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY

-Camille Bauer. Phone: Fax: American Way Libertyville, IL USA. Application Challenges! Sig. Cond.

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Temperature sensors TTM series. Miniature transmitters

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Interface technology. Interface technolog. Interface technology INTERFACE TECHNOLOGY. Sense it! Connect it! Bus it! Solve it!

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Your Global Automation Partner. Uprox IO-Link Inductive Factor 1 Sensors with IO-Link

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

NEW. TURCK Inductive Sensors - Specialty DS20

Proportional Control Unit (PCU)

USB-PDISO8 Specifications

MMTCP6RTD - RTD INPUTS

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Level-Lance Model 5400A

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Transcription:

TURCK Interface Technology Analog output isolators are for use with conventional 4/20 ma or HART smart "IS" devices are available in 1 and 2 channel versions. These devices are designed to provide a convenient way to transfer 4/20 ma signals, generated in a non-hazardous area, to a hazardous area intrinsically safe device, such as a valve positioner or I/P device. HART capabilities allow bi-directional communications for HART devices if this function is being utilized. The same devices are also applicable for non-hart smart devices. One device can be used for all applications of this type, which makes applying these devices simple. Stocking spares only requires one type of unit adding to the convenience.

Interface Module Application Guide Part Number Key Part Number Keys are to assist in IDENTIFICATION ONLY. Consult Factory for catalog items not identified. IM 35-1 2 Ex - Hi / 24 VDC Interface Module Supply Voltage (19-29 VDC) Function Group 35 = Analog Output Isolator Number of Hazardous Area Inputs HART Compatible or General Purpose Intrinsically Safe Associated Apparatus Number of Non-Hazardous Area Outputs Extension Examples: IM35-11Ex-Hi/24 VDC Interface Module Analog Output Isolator Single Channel Input One Non-Hazardous Area Current Output Intrinsically Safe Associated Apparatus HART Compatible 24 VDC Supply Voltage

TURCK Interface Technology IM35-11Ex-Hi/24 VDC Functional Description: This single channel device will allow a controller in a non-hazardous area to provide a 1:1 transfer of a 0/4-20 ma signal to a device in a hazardous area. Valve controllers or I/P devices that are intrinsically safe, as well as signals that are "IS" originating from another non-hazardous area, may be accommodated. Bi-directional HART communications capability is also incorporated. Features: 1 channel 0/4-20 ma current driver HART or non-hart compatible Allows bi-directional HART communications Facilities for non-hazardous area HART monitoring Linearity of less than 0.1% Temperature drift less than 0.01% /K Electrical Parameters: Inputs: Hazardous Area Supply Voltage (19-29 VDC) 0-20 ma 24 ma can be transferred max load of 430 Ω Input Resistance 110 Ω Outputs: Non-Hazardous Area 0/4-20 ma (Load 600 Ω max.) Relay: 250 VAC/120 VDC, 2A 500 VA/60 W 10Hz For entity parameters see control drawings on pages 86-91.

Interface Module Application Guide IM35-11Ex-Hi/24 VDC Pin # Terminal Function 1 (+) 0/4-20 ma Field Output 2 (-) 0/4-20 ma Field Output 3 No Connection 4 No Connection 5 No Connection 6 No Connection 7 (+) 0/4-20 ma Non-Hazardous Area Input 8 No Connection 9 No Connection 10 (-) 0/4-20 ma Non-Hazardous Area Input 11 Module Power (+) 12 Module Power (-)

TURCK Interface Technology IM35-22Ex-Hi/24 VDC Functional Description: This dual channel device will allow a controller in a non-hazardous area to provide a 1:1 transfer of 2 separate 0/4-20 ma signals to two separate devices in the hazardous area. Valve controllers or I/P devices that are intrinsically safe, as well as signals that are "IS" originating from another non-hazardous area, or any combination of these signals, may be accommodated. Bi-directional HART communications capability is also incorporated for both channels. Features: 2 channel 0/4-20 ma current driver HART or non-hart compatible Allows bi-directional HART communications Facilities for non-hazardous area HART monitoring Linearity of less than 0.1% Temperature drift less than 0.01% /K Electrical Parameters: Inputs: Hazardous Area Supply Voltage (19-29 VDC) 0-20 ma 24 ma can be transferred max load of 430 Ω Input Resistance 110 Ω Outputs: Non-Hazardous Area 0/4-20 ma(load 600 Ω max) 24 ma with a max load of 430 Ω Load is 600 Ω max For entity parameters see control drawings on pages 86-91.

Interface Module Application Guide IM35-22Ex-Hi/24 VDC Pin # Terminal Function 1 (+) 0/4-20 ma Field Output 2 (-) 0/4-20 ma Field Output 3 No Connection 4 (+) 0/4-20 ma Field Output 5 (-) 0/4-20 ma Field Output 6 No Connection 7 (+) 0/4-20 ma Non-Hazardous Area Input 8 (+) 0/4-20 ma Non-Hazardous Area Input 9 (-) 0/4-20 ma Non-Hazardous Area Input 10 (-) 0/4-20 ma Non-Hazardous Area Input 11 Module Power (+) 12 Module Power (-)