ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

Similar documents
Protect Circuit Protection

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

NEW Titan II A & B Distribution Boards

RCDs RCBOs MCBs Isolating Switches Switchboards

TP&N DISTRIBUTION BOARD TYPE B RANGE

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

Sentry. Flush mounting versions Flush mounting available for even neater installations.

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Defender 1.0. Consumer Units & Devices Domestic Household Premises

Defender. Consumer Units & Devices Domestic Household Premises

O V E R Y E A R S O F E L E C T R I C A L E X C E L L E N C E

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Residential circuit protection buyers guide

Defender 1.0. Consumer Units & Devices Domestic Household Premises

pointofsale available at your local trade outlet

Switched Mode Power Supply Operating manual PAP800

LC SmartGlass SPD SmartGlass

Enclosures & Rotary Switches

RCCB

Domae and Qwikline ll. Consumer units

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

RB60 RANGE. Miniature circuit breakers

the Santon FCS-type switch Disconnect Superior Switch Solutions

Starbreaker Consumer Units & Devices

Isobar 4c distribution boards and devices Selection guide

SMARTSCAN INFORMATION

www. ElectricalPartManuals. com

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

TP&N Distribution Systems

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Memguard Advantage DISTRIBUTION SYSTEM Product Guide. MCB Single Phase Distribution Boards MCB Three Phase Distribution Boards

SMARTSCAN INFORMATION

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

ic60n RCBO 30 ma IEC , IEC , AS/NZS

The right solution for every home

B60 Domestic Voltage Optimisation Unit. Installation Manual

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

PRO-75 SERIES. User manual

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Common Departures Interconnecting Facilities Requirements

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Specification Voltage Limiting Device

LOADSTAR MCBs AND DISTRIBUTION BOARDS

Operating Manual -ENGLISH- Page 1 KWG-ISO

Loadlimiter 63. MCB Distribution Boards

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

B60 Domestic Voltage Optimisation Unit

Defender B Board. Make The Switch

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Weathersafe Vision. Installation & Operating Instructions

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

L.V. Systems & Solutions

Starbreaker Consumer Units for Domestic Household - and other - Premises. Amendment No. 3 BS 7671

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

B60 Domestic Voltage Optimisation Unit. Installation Manual

MOTOR PROTECTION CIRCUIT BREAKERS

DSE201, DSE201 M Compact design with enhanced protection

Consumer Units - Metal

Pan assemblies and installation accessories

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Dorman Smith Loadbank 125 MCCB Panel Boards

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Fuse Switch Panel Boards

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Allen-Bradley 1492-RCDA4A40

For Sales and Support call KMParts.com (866)

Specifications, Installation, and Operating Instructions

Dtec Consumer units and

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Thermal-Magnetic Circuit Breaker 4220-T...

Circuit Protection. Domestic. Consumer units, Enclosures, Devices, Surge protection, Rotary isolators and accessories

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

920 Remote Control (RC) Switches

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

M260 Load Cell Amplifiers

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

9926 Series Branch Rated Circuit Breakers AC Version

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Design Range of Consumer Units. Amendment 3 compliant

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

INSTALLATION & OPERATING MANUAL

5SL Miniature Circuit Breakers

Transcription:

CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel with lift up lid ß Various sizes of knock outs for easy cabling ß Attractive off white finish ß Designed to easily accommodate RCBOs ß 3rd party approved as meeting current standards ß High integrity ready boards

METAL CONSUMER UNITS Introducing the Chint NX3 Metal Consumer Units OVERVIEW Electricity Is Dangerous. Electrical Installations should be designed and carried out in accordance with Current Electrical Regulations i.e., Regulations for Electrical Installations. Care being taken to ensure that circuits involving MCBs, RCBOs meet the requirements of table 41.6 page 64, BS7671:2008. It is highly recommended that that this equipment is installed by suitably qualified personnel. Throughout the installation and at the completion of all appropriate works, inspection and testing must be carried out to satisfy as far as is reasonably practical that the regulations have been met. Maximum current ratings of the Mains Incomer (100A) Must Not be exceeded. To avoid nuisance tripping, overheating etc., it is important that sufficient air circulation is allowed and that appropriate diversity factors are taken into consideration. RCDs/RCBOs are of delicate construction, easily damaged when exposed to the high voltages typically carried out when carrying out certain tests. With this in mind it is crucial they are disconnected from the Bus Bar prior to carrying out insulation resistance testing. Care must be taken to reconnect all devices prior to handing the system over to end users. The name Chint is your assurance of Top Quality. Many Chint components are independently tested by 3rd Party test houses as complying with appropriate regulations. It might be helpful if copies of Test Certificates are included with your quotations thus giving your customers the assurance that you are offering top quality materials. Test Certificates can be readily downloaded from www.chint.co.uk. Alternatively by calling Chint Technical on 0161 762 9333. Chint products are independently tested and approved 2

Chint NX3 Metal Consumer Units Tel: 0161 762 9333 Fax: 0161 762 9898 The Chint NX3 range of Metal Consumer is available from the 3 Ways up to 36 Ways. The NX3 range of Metal Consumer Units is available from 3 Ways to 36 Ways The NX3s are designed to comply to the new 3rd Amendment BS7671:2008 and BSEN 61439-3. The entire range is tested and approved to those standards by independent third parties. There is an interconnecting cable available for ease of cabling between the mains incomer and individual RCDs. The large enclosure size is often asked for by customers who might want to add specialised equipment such as Meters, Contactors and Transformers and where space is not limited. Certificates are readily available at www.chint.co.uk 3

METAL CONSUMER UNITS Chint NX3 Range of Metal Consumer Units NX3-3 NX3-3RA NX3-4 NX3-5 NX3-5RA NX3-5RA-SA NX3-6 NX3-6MS NX3-6RCD NX3-8MS NX3-8RCD NX3-10MS NX3-10RCD NX3-14RA NX3-14RCD NX3-14S 4

Tel: 0161 762 9333 Fax: 0161 762 9898 NX3-16MS NX3-16RA NX3-16RCD NX3-16S NX3-18MS NX3-18RA NX3-18RCD NX3-18S NX3-20MS NX3-20S NX3-22MS NX3-22S NX3-28 NX3-36 5

METAL CONSUMER UNITS Ready Assembled Metal Consumer Units NX3-14RA 14 Way Ready Assembled Consumer Unit Complete with 2 RCDs, 1*100A DP Incomer, 6 MCBs plus 2 Spare Ways RCD MCB MCB MCB MCB RCD MCB MCB SPARE WAY SPARE WAY DP ISOLATOR NL1 EBG EBG EBG EBG NL1 EBG EBG SPARE WAY SPARE WAY NH4 2P 100A Configurations for NX3-14RA NX3-16RA 16 Way Ready Assembled Consumer Unit Complete with 2 RCDs, 1*100A DP Incomer, 8 MCBs plus 2 Spare Ways RCD MCB MCB MCB MCB MCB RCD MCB MCB MCB SPARE WAY SPARE WAY DP ISOLATOR NL1 EBG EBG EBG EBG EBG NL1 EBG EBG EBG SPARE WAY SPARE WAY NH4 2P 100A Configurations for NX3-16RA NX3-18RA 18 Way Ready Assembled Consumer Unit Complete with 2 RCDs, 1*100A DP Incomer, 10 MCBs plus 2 Spare Ways. RCD MCB MCB MCB MCB MCB MCB RCD MCB MCB MCB MCB SPARE WAY SPARE WAY DP ISOLATOR NL1 EBG EBG EBG EBG EBG EBG NL1 EBG EBG EBG EBG SPARE WAY SPARE WAY NH4 2P 100A Configurations for NX3-18RA 6

Dual RCD Metal Consumer Units NX3-14S 4 x 4 Dual RCD Consumer Unit Complete with 2*63A 30mA RCDs, 1*100A Main Switch Tel: 0161 762 9333 Fax: 0161 762 9898 NX3-16S 5 x 5 Dual RCD Consumer Unit Complete with 2*63A 30mA RCDs, 1*100A Main Switch NX3-18S 6 x 6 Dual RCD Consumer Unit Complete with 2*63A 30mA RCDs, 1*100A Main Switch NX3-20S 7 x 7 Dual RCD Consumer Unit Complete with 2*80A 30mA RCDs, 1*100A Main Switch NX3-22S 8 x 8 Dual RCD Consumer Unit Complete with 2*80A 30mA RCDs, 1*100A Main Switch 7

METAL CONSUMER UNITS NX3 Metal Boards Complete with 100A DP Main Incomer NX3-6MS NX3-8MS NX3-16MS NX3-20MS NX3-6MS 4 Empty Ways, Plus 100A Incomer NX3-16MS 14 Empty Ways, Plus 100A Incomer NX3-8MS 6 Empty Ways, Plus 100A Incomer NX3-18MS 16 Empty Ways, Plus 100A Incomer NX3-10MS 8 Empty Ways, Plus 100A Incomer NX3-20MS 18 Empty Ways, Plus 100A Incomer NX3-14MS 12 Empty Ways, Plus 100A Incomer NX3-22MS 20 Empty Ways, Plus 100A Incomer NX3 Metal Boards Complete with 2 Pole RCDs NX3-6RCD NX3-8RCD NX3-16RCD NX3-18RCD NX3-6RCD 4 Empty Ways, Plus 1*63A RCD NX3-14RCD 12 Empty Ways Plus 1*80A RCD NX3-8RCD 6 Empty Ways Plus 1*63A RCD NX3-16RCD 14 Empty Ways Plus 1*80A RCD NX3-10RCD 8 Empty Ways Plus 1*80A RCD NX3-18RCD 16 Empty Ways Plus 1*80A RCD 8

Tel: 0161 762 9333 Fax: 0161 762 9898 3-6 Module Empty Metal Enclosures with prefitted DIN Rail, Earth and Neutral Bars 3 Module Ready Assembled Metal Units (Shower Units) NX3-3 NX3-4 NX3-5 NX3-6 3 Modules 4 Modules 5 Modules 6 Modules NX3-3RA 3 Module Metal Enclosure Complete with 1*2 Pole 63A/30mA RCD and 1*40A MCB 5 Module Ready Assembled Metal Units including RCD, MCBs & Meter Available with or without Padlocking facility (suitable for Student Accommodation) 5 Module Ready Assembled Metal Units (Garage Units) NX3-5RA-SA 5 Module Metal Enclosure Complete with prewired 63A/30mA RCD, 1*20A, 1*6A B Curve MCB and 1*45A Meter NX3-5RA 5 Module Metal Enclosure Complete with 1*2 Pole 63A/30mA, 1*6A and 1*16A B Curve MCB 9

METAL CONSUMER UNITS 28 Way Dual RCD Metal Consumer Units NX3-28S 28 Module Metal Enclosure Complete with 2*80A 30mA RCDs, 1*100A Main Switch 36 Way Dual RCD Metal Consumer Units NX3-36S 36 Module Metal Enclosure Complete with 2*80A 30mA RCDs, 1*100A Main Switch 10

Tel: 0161 762 9333 Fax: 0161 762 9898 ebg Series, MCBs 1 POLE, 6KA Boxed in 12s B CURVE PART NO. 6A, 1P EBG-1P-B06 10A, 1P EBG-1P-B10 16A, 1P EBG-1P-B16 20A, 1P EBG-1P-B20 EBG, 1P 32A, 1P EBG-1P-B32 40A, 1P EBG-1P-B40 NL1 Series, RCDs RCD, 2 POLE, AC TYPE NL1-63-2P DESCRIPTION 25A 30mA, 2P 25A 100mA, 2P 25A 300mA, 2P 40A 30mA, 2P 40A 100mA, 2P 40A 300mA, 2P 63A 30mA, 2P 63A 100mA, 2P 63A 300mA, 2P 80A 30mA, 2P 80A 100mA, 2P 80A 300mA, 2P 100A 30mA, 2P 100A 100mA, 2P 100A 300mA, 2P PART NO. NL1-63-225/30 NL1-63-225/100 NL1-63-225/300 NL1-63-240/30 NL1-63-240/100 NL1-63-240/300 NL1-63-263/30 NL1-63-263/100 NL1-63-263/300 NL1-100-280/30 NL1-100-280/100 NL1-100-280/300 NL1-100-2100/30 NL1-100-2100/100 NL1-100-2100/300 NL1-100 TIME DELAY RCDs DESCRIPTION 80A 100mA, 2P 80A 100mA, 4P 100A 100mA, 2P PART NO. NL1-100-280/100-S NL1-100-480/100-S NL1-100-2100/100-S 11

METAL CONSUMER UNITS RCBOs NB3LEU, 10KA RCBO DESCRIPTION B CURVE C CURVE 6A 30mA NB3LEU-B06 NB3LEU-C06 10A 30mA NB3LEU-B10 NB3LEU-C10 16A 30mA NB3LEU-B16 NB3LEU-C16 NB3LEU 20A 30mA NB3LEU-B20 NB3LEU-C20 25A 30mA NB3LEU-B25 NB3LEU-C25 32A 30mA NB3LEU-B32 NB3LEU-C32 40A 30mA NB3LEU-B40 NB3LEU-C40 NCH8 Modular AC Contactors 2 and 4 NO main poles 230V AC coils 20A, 40A and 63A Quiet operation 2 POLE, MODULAR AC CONTACTORS DESCRIPTION PART NO. 2 Pole 20A 2 NO, 230V AC Coil NCH8-20 2 Pole 20A 2 NC, 230V AC Coil NCH8-20-02 NCH8-20 2 Pole 40A 2 NO, 230V AC Coil NCH8-40/20-230V 4 POLE, MODULAR AC CONTACTORS DESCRIPTION PART NO. NCH8-4P-63 4 Pole 40A 4 NO, 230V AC Coil NCH8-4P-40 4 Pole 63A 4 NO, 230V AC Coil NCH8-4P-63 12

Tel: 0161 762 9333 Fax: 0161 762 9898 NH4 Isolators 1 Pole: Boxed in 12s. 2 Pole: Boxed in 6s. 3 Pole: Boxed in 4s. 4 Pole: Boxed in 3s. NH4 ISOLATORS DESCRIPTION PART NO. 100A, 1P NH4-80108 NH4-80208 100A, 2P NH4-80208 100A, 3P NH4-80308 100A, 4P NH4-80408 125A, 1P NH4-90108 125A, 2P NH4-90208 125A, 3P NH4-90308 NH4-80408 125A, 4P NH4-90408 Bell Transformer 230V, 50Hz input 6V, 9V, 12V, 24V output BELL TRANSFORMER DESCRIPTION Din Rail Mounted Bell PART NO. SBT-16 SBT-16 Transformer DIN Rails DR1 Available in 1m and 2m stock lengths with 6mm wide centre slots 35mm TOP HAT SECTION DIN RAIL DESCRIPTION 1m length Din Rail 2m length Din Rail PART NO. DR1 DR2 13

NXDB MKIII BOARDS NXDB 125A TP&N Distribution Boards 14 Call us for a copy of the catalogue above on 0161 762 9333.

THE PROFESSIONALS CHOICE CHINT EUROPE (UK) LTD. Units 9 & 11, Spark Business Park, Hamilton Road, Stockport SK1 2AE TEL: 0161 762 9333 FAX: 0161 762 9898 www.chint.co.uk

METAL CONSUMER UNITS PART NUMBERS DIMENSIONS (in mm) PT. NO. QTY/ CARTON NET WEIGHT GROSS WEIGHT CARTON SIZE (in mm) Width Depth Height BOX QTY. Kg Kg Length Width Height Metal Consumer Units NX3-3* 95 100 230 NX3-4* 113 100 230 NX3-5* 131 100 230 NX3-6* 149 100 230 NX3-8* 220 118 250 NX3-10* 246 118 250 NX3-14* 328 118 250 NX3-6MS 6 14.30 11.70 420 375 305 NX3-8MS 4 12.30 9.60 600 265 315 NX3-10MS 4 13.80 10.80 600 305 315 NX3-14MS 4 13.80 10.80 600 305 315 NX3-16MS 2 5.30 3.30 420 265 305 NX3-16S 2 5.60 3.20 420 340 305 NX3-18S 2 6.50 3.90 420 375 305 NX3-20S 4 10.40 7.80 420 375 305 NX3-16* 364 118 250 NX3-18* 400 118 250 NX3-20* 436 118 250 PT. NO. QTY/ CARTON NET WEIGHT GROSS WEIGHT CARTON SIZE (in mm) NX3-22* 472 118 250 NX3-28* 339 122 443 NX3-36* 411 122 443 *MS/RA/RCD/S and Empty Versions EACH UNIT Kg Length Width Height NX3-6MS 1.95 152 234 102 NX3-8MS 2.40 220 250 113 NX3-10MS 2.70 256 250 113 NX3-14MS 3.30 328 250 113 NX3-16MS 3.55 364 250 113 NX3-16S 4..25 364 250 113 NX3-18S 4.60 400 250 113 NX3-20S 4.80 436 250 113 AVAILABLE FROM YOUR LOCAL STOCKIST: Chint Europe (UK) Ltd, Units 9 & 11, Spark Business Park, Hamilton Road, Stockport SK1 2AE Tel: +44 (0) 161 762 9333 Fax: +44 (0) 161 762 9898 E-mail: sales@chint.co.uk www.chint.co.uk CHINT Group All Rights Reserved. Specifications and technical data are subject to change without notice. Please contact us to confirm relevant information on ordering. AMENDMENT3.0216/8PP/002