ph fax Deming Way Middleton WI USA

Similar documents
DAILY LINAC QA BEAM QA

REF User Manual DOC # STANDARD IMAGING, INC Deming Way Middleton, WI

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

FAST, precise. qa software

Beams You Up to a New Era in 3D Water Scanning.

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Machine and Physics Data Guide

Clinical implementation of photon beam flatness measurements to verify beam quality

UNCOMPROMISING QUALITY

Initial Clinical Experience with 3D Surface Image Guidance

Raising the Bar in IMRT QA

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Table of Contents. About AQUA

PROVEN TECHNOLOGY IMPROVED

TOMOHD. Product Specifications

Quality assurance of a helical tomotherapy machine

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

Feasibility study of performing IGRT system daily QA using a commercial QA device

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

ADVANCING CANCER TREATMENT

INSTRUCTIONS RPD INFORMATION RPD PRODUCT INFORMATION. Address 5218 Barthel Industrial Drive Albertville, MN Website

Version 5.6. Quick Start Guide

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Multi-Purpose Body Phantom

Quick Reference Datasheet For All RIT113 Packages

1.0 Introduction. 1.1 General

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

Quattro Flow. Air Velocity Analyzers. Mobile Multipoint Evaluation CAMBRIDGE ACCUSENSE, INC.

CNMC 865 Easthagan Drive, Nashville, TN USA phone

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

OPTALIGN smart RS5 The power of precision shaft alignment

OPTALIGN smart RS5 The power of precision shaft alignment

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

O T Auto-Aligning Straight Line Laser System.

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

Nano DSC and MCDSC. Site Preparation Guide

ZLS Corporation. ZLS Dynamic Meter for Marine Applications EXCELLENCE IN GRAVITY METERS. ZLS Dynamic Meter. Applications

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

MPT-250C Wire Crimp Pull Tester

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

DL1000 DURABILITY & LUBRICITY TEST SYSTEM

TAM Air Isothermal Calorimeter. Site Preparation Guide

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

Superior Imaging on the Go

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

Automated Quality Assurance for Image-Guided Radiation Therapy

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

350 Series AC/DC Clamp Meters

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Alignment Software for Linear Guides

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

TA Instruments Installation Requirements for Microcalorimeter Systems

Leica DISTO D2 Laser Distance Meter

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

A NEW LASER FOCUS ON PATIENT SAFETY

TA Instruments Installation Requirements for Microcalorimeter Systems

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Superior Imaging on the Go

SMART Audio classroom amplification systems Model CAS-340

TA Instruments Installation Requirements for Microcalorimeter Systems

C504-E013A. Mobile X-Ray System A-NS

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

4700 Series RAID-Enabled Industrial PCs DS _RAID(C)

ADVANCING CANCER TREATMENT

Rack Installation Instructions

Experiences of daily use of a database for linear accelerator quality control

Model Operators Manual. TRACKER System

GPS mini Watch User Manual Introduction. Getting Started. Caution: Step 1) Know your Watch:

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

MMT330 Series Moisture and Temperature Transmitters for Oil

Evaluation of AutoQA Lite TM Image Quality Measurement Software

Basic Radiation Oncology Physics

DoseLab for TomoTherapy. AAPM Task Group 148 Background

Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

PRODUCT GUIDE. Your Data, Anytime, Anywhere.

Instruments and Capabilities (Panel Mount and Standalone) By: Thornton Leading Pure Water Analytics

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

CANON S INNOVATIVE FLAT PANEL DETECTOR (CXDI-50G)

Dräger UCF 6000 Thermal Imaging Camera

LAR 350 rotation laser: Tough DUAL SLOPE laser kit Made in Germany. World s first MOTION CONTROL

Version 3.7. User Manual

Photon beam dose distributions in 2D

Precision hand-held pressure indicator Model CPH6400

First Automated and Self Calibrating Voltage Divider

SHAFTALIGN OS3 The efficiency of laser shaft alignment

Transcription:

www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA 2007 Standard Imaging, Inc. 1239-21 (03.07)

beam qa LINAC AND TOMOTHERAPY QA The NEW QA BeamChecker Plus for fast, reliable, and uncomplicated daily QA of linear accelerators and TomoTherapy Hi-Art Systems

Reliable and Uncomplicated Daily QA The QA BeamChecker Plus was designed to save radiation therapists time with their daily QA routine. Those repeated trips in and out of the vault are a thing of the past. There s a better way. Just set your QA BeamChecker Plus on the couch and run your routine returning to the couch only once to flip from photons to electrons. That s it. You re done. Quality assurance you can trust. For use with Linear Accelerator AND TomoTherapy Hi-Art Systems The patented QA BeamChecker Plus can now be used to perform daily QA not only on linear accelerators, but also the TomoTherapy Hi-Art System. Do you use one or more TomoTherapy Hi-Art Systems at your facility? Plan on investing in tomotherapy in the future? The Standard Imaging QA BeamChecker Plus is ready for your daily QA needs no matter what system you use. The time saving features available in linear accelerator mode are also used for TomoTherapy daily QA. With three quick, integrated operations, your daily QA tests are done in 10 minutes. Standard Imaging Advancing Radiation QA

The patented QA BeamChecker Plus shown on a linear accelerator couch ready for measurement Wire-Free Technology After creating QA BeamChecker Plus measurement baselines using the accompanying PC software, no cables or software are needed to complete your daily QA routine. With automatic energy detection, simply step through the energies being tested for easy, efficient daily QA.

Fast and Easy... QA BeamChecker Plus Reduce unnecessary trips into the treatment room Automatic Energy Detection T he QA BeamChecker Plus automatically detects the energy type and simultaneously determines beam constancy, flatness, and symmetry. It then re-arms itself within 10 seconds for the next treatment. Wire-Free Technology N o cables means less clutter in the accelerator room, no cable replacement costs, and a safer work environment... no accidental tripping or pulling the instrument off the couch. Wire-free set-up allows technicians to quickly complete daily QA procedures. Unlike some devices, you do not have to control the QA BeamChecker Plus from software for a true wire-free solution. Multiple Vault Capability U p to nine treatment rooms/vaults can be managed with just one QA BeamChecker Plus. Using the Communication Software, a complete set of linear accelerator or TomoTherapy Hi-Art System baselines can be created for each specific room. Once a room has been created, it becomes selectable from the QA BeamChecker Plus in any mode, including Wire-Free. When performing daily QA, simply select the desired room and the QA BeamChecker Plus automatically detects the energies provided by the operator. 1 = 9 treatment rooms any combination of linear accelerator or TomoTherapy Hi-Art Systems Proven and patented daily QA

Integrated Build-up I ntegrated build-up for all energies eliminates the need to enter the vault between measurements. After the quick flip of the QA BeamChecker Plus, the large, brightly lit display, easily visible from the patient monitor, rotates between photon or electron based on which side of the QA BeamChecker Plus was chosen with the mode button. The Quick Flip Photon to electron with no additional build-up QA BeamChecker Plus Power/Data Cradle Recharge and transfer data Q uickly download up to one month s data and simultaneously ensure your QA BeamChecker Plus is always fully charged using the Power/Data Cradle. The Power/Data Cradle connects to an available serial port on your PC and provides quick, convenient downloading of measurement data using the simple software interface. Simplify your daily QA routine and save time with the QA BeamChecker Plus

Intuitive Communication Software Informative Real-time Operation, dynamic new Physics Mode, powerful reporting Real-time Operation R eal-time Operation Mode immediately compares daily measurements with saved baseline data. Because the QA BeamChecker Plus is connected to a computer in this mode, the calculated values for each measurement can immediately be displayed. Real-time Operation Mode is ideal for troubleshooting, teaching, or for research when the measured data is not intended to become part of the permanent daily QA record as exposure data can be saved or discarded after each measurement. Physics Mode A user controlled Physics Mode with access to raw data is available to the physicist for creating custom measurements for enhanced dynamic wedge tests, TPR machine QA tests, and research applications. QA BeamChecker Plus Real-time Operation Mode The Physics Mode provides access to the raw data being collected by the A/D converters in the form of counts. There are two windows for each detector, the top window shows the active counts per second (rate). The lower window shows the accumulated counts over time (charge). The Physics Mode puts the physicist in complete control of the accumulation and interpretation of measurement data. This versatility allows tests of enhanced dynamic wedges and tissue phantom ratios. Access to the actual energy measurements is useful for customized QA protocols and for research. The Physics Mode operates in real-time, so it requires connection to the QA BeamChecker Plus while in use. QA BeamChecker Plus Physics Mode Easy to use Communication Software for quick, detailed analysis of measurement data

TomoTherapy Hi-Art System Daily QA Linear Accelerator and TomoTherapy Hi-Art System QA in one device T he QA BeamChecker Plus can be used for TomoTherapy Hi-Art System daily QA measurements. The tests performed follow those listed in J D Fenwick et al, Quality assurance of a helical tomotherapy machine 1 : output constancy (D1), energy constancy (D2), lateral profile constancy (D3), combined dosimetric check (D5), and laser accuracy (D6). (See Table 1 for more information) Only two exposures are required to perform these tests; one in a static mode, with the gantry fixed in a vertical position, and one in a dynamic mode. No re-positioning of the QA BeamChecker Plus is required between the two exposures. A baseline is established for both modes. Static mode [STA] covers three tests in one exposure (D1-D3). For the dynamic mode [DYN], a 4D treatment plan is delivered to the QA BeamChecker Plus to establish the baseline. This plan is saved and then delivered each day for future dynamic daily constancy comparison as a combined dosimetric check (D5). The Precision TomoTherapy Leveling Platform levels the QA BeamChecker Plus on the TomoTherapy Hi-Art System treatment couch to allow for laser accuracy measurements. Laser accuracy measurements are done between virtual isocenter and real isocenter using MVCT images to 2 mm lead BBs embedded within the QA BeamChecker Plus. Laser alignment accuracy and coincidence is tested between 7 lasers using alignment marks shown in the image below. QA BeamChecker Plus shown with Precision TomoTherapy Leveling Platform (REF 70505) Alignment marks facilitate the TomoTherapy laser accuracy test (D6) Operation is so easy, medical physicists can pass on daily QA procedures to radiation therapists

Powerful Reporting W hen data has been acquired by the QA BeamChecker Plus in either Wire-Free or Real- Time Operation Modes, the measurement details can be tracked and viewed with Data View Mode. This measurement data can be viewed in either table or graph view for any date range, printed in an easy to file report, or exported to a Microsoft Excel compatible format. View measurement data in graph or table view, print a report, or export all data points to a.csv file for a custom reporting solution Data Storage and Network Capability D ata for approximately one month can be stored within the QA BeamChecker Plus internal memory before downloading to a PC is necessary. The QA BeamChecker Plus database file can be stored and maintained anywhere, even on a computer network. The QA BeamChecker Plus Communication Software can be installed on a multiple computers so linear accelerator or TomoTherapy Hi-Art System data can be viewed from as many terminals as needed. Intuitive tree structure makes managing baselines and measurement data for multiple treatment vaults easy Easily monitor, track, and report daily QA performance

Q A B e a m c h e c k e r p l u s ( r e f 9 0 5 0 1 ) s p e c i f i c a t i o n s 8 vented ionization chambers, fully guarded One center detector Four quadrant detectors, 7.5 cm from center Three energy identification chambers Tomotherapy alignment real time clock Three 2 mm embedded lead BBs, top, rear, side alignment marks Date and time stamp for all measurements for easy identification chamber volume 0.6 cm 3 internal memory Store 512 data points before transfer required parallel plate separation Collection Electrode 4.0 mm 1.39 cm diameter inherent buildup PHOTONS: 3.5 cm water-equivalent material ELECTRONS: 1.5 cm water-equivalent material radiation measured PHOTONS: ELECTRONS: 60 Co to 25 MV 6 MeV to 25 MeV multiple vault capability Up to 9 rooms, any combination of linear accelerator or TomoTherapy Hi-Art Systems Temperature and pressure measurement Precision sensor on board, automatic compensation PRESSURE RANGE, RESOLUTION: 600-800 mmhg, 0.1 mmhg TEMPERATURE RANGE, RESOLUTION: 10-40 C, 0.1 C DIMENSIONS Height: 6.15 cm, 2.42 in Width: 30.86 cm, 12.15 in (QA BC Plus) Length: 40.64 cm, 16 in Weight: 5.0 kg, 11 lbs DIMENSIONS Height: 7.16 cm, 2.82 in Width: 10.16 cm, 4.0 in (Power/Data Cradle) Length: 29.21 cm, 11.50 in Weight: 1.8 kg, 4 lbs light field alignment 20 cm x 20 cm alignment grid for easy setup POWER/dATA cradle Interface for battery charging and serial communications Two 9 pin serial cables provided, 7.6 m (25 ft) and 33 m (100 ft) POWER BATTERY: CHARGER INPUT: operating system Microsoft Windows 2000 Microsoft Windows XP ProceSSOR Memory Hard Drive Screen resolution PERIPHERALS 1.3 Ah SLA, provides approximately 4 hours of continuous use 90-240 VAC, 50-60 hz, IEC 60601-1 approved wall mounted power supply Intel or AMD, 350 MHz or greater 64 MB (256 MB recommended) 50 MB or greater 800 x 600 (1024 x 768 recommended) CD-ROM Drive, One available serial port options Gantry Mount (REF 70500) Additional Power/Data Cradle (REF 70502) Serial to USB adapter (REF 70503) Precision TomoTherapy Leveling Platform (REF 70505) TomoTherapy is a registered trademark of TomoTherapy Incorporated. Windows is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. Table 1: TomoTherapy Hi-Art System Daily QA Tests 1 J D Fenwick et al, Quality assurance of a helical tomotherapy machine, Phys. Med. Biol. 49(2004) 2933-2953 test test description tolerance test mode field used detector D1 Output Constancy ± 2% Static D2 Energy Constancy ± 2% Static Static 5 x 20 cm Static 5 x 20 cm TPR 9.7/3.5 One centered 0.6 cc ion chamber Two 0.6 cc ion chambers D3 Lateral Profile Constancy ± 2% Static Static 5 x 20 cm Three 0.6 cc ion chambers D4 Output Ramp Up Time <10 sec not applicable not applicable Hi-Art s integrated detector system D5 Combined Dosimetric Check of jaw width, couch speed, leaf latency, output and leaf/gantry synchronicity ± 2% Dynamic Dynamic modulated treatment Three 0.6 cc ion chambers D6 Laser Accuracy ± 1 mm Beam off not applicable Alignment marks, Precision TomoTherapy Leveling Platform