SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Similar documents
SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR UC/ESAM4/3X1/1X2/B

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PSR DC/ESP4/2X1/1X2

QUINT-PS/ 1AC/24DC/ 5

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

TRIO-DIODE/12-24DC/2X10/1X20

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

PHOENIX CONTACT - 07/2006

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

E-STOP relays, safety gate monitors

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Operating instructions. Standstill monitor A / / 2011

QUINT-PS/24DC/48DC/ 5

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ETD-BL-1T-OFF-CC- 10S

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power Supply HARTING pcon

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

QUINT-PS/ 1AC/24DC/20/CO

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Safe timer relay/contact expansion modules

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

AS-i Safety Relay Output Module with Diagnostic Slave

PNOZ s1. Safety relays. Operating Manual EN-07

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

QUINT-PS AC/24DC/10

MINI-PS AC/10-15DC/8

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PHOENIX CONTACT - 01/2007

E-STOP relay, safety gate monitor

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Safety Relays 3TK2845 Multifunction Device

Safety relays PNOZsigma

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

ENGLISH. Terminals 13, 14, 23, 24, 43, 44, 53, Web: Phone: Toll Free:

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

ELR H3-IES-PT- 24DC/500AC-...

Power Supply HARTING pcon

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

E-STOP relays, safety gate monitors

QUINT-BUFFER/24DC/24DC/40

E-STOP relays, safety gate monitors

Making Hazardous Operations Safe and Productive

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

E-STOP relays, safety gate monitors

Safe monitoring relays

STEP-PS/1AC/24DC/1.75

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

E-STOP relays, safety gate monitors

Non-Contact Safety System CES-AZ

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Two-hand control unit

HR1S-AC Safety Relay Modules

Two-hand control unit

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Safety automation solutions

Power supply CP-C 24/5.0

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Labeling accessories Art.-No. suitable. Wiring accessories Art.-No. suitable. Color: blue 10-pole spacing 6.2 mm MIRO 6.2

Datasheet - SRB 402EM-24V

Two-hand control unit

Contact protection relay

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PNOZ s2. Safety relays. Operating Manual EN-07

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Operating Instructions

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Performance Level PL d. Safety Category Type 3. Automatic reset / Manual reset. Very short reaction times. Connection of several signal transmitters

E-STOP relays, safety gate monitors

MODULES FOR SAFETY AND MONITORING

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Transcription:

SNO 4003 K plus Safety relay for emergency stop and guard door applications SILCL2 in accordance with EN 62061 PL d, Category 3 in accordance with EN ISO 13849-1 Stop category 0 in accordance with DIN EN 60204-1 Manual or automatic start With cross circuit detection of the reset inputs Feedback circuit for external contactor monitoring 3 enable circuits, NO positively guided, 1 signal generator current circuit Input debouncing Error message by SUPPLY-LED Connection circuit diagrams SNO 4003K (-A/-C) plus (DC 24 V) Areas of application for the unit The safety relay SNO 4003K plus can be used in accordance with EN 62061 to SILCL2 in accordance with EN ISO 13 849-1 to PL d and Category 3 The actual performance level achieved and the safety category as per EN ISO 13 849-1 depends on external switching, execution of the wiring, selection of command generator and its setup on the machine. Tactile safety sensors are connected to the safety relay (e.g. safety switch, emergency stop switch).the switching outputs of the safety relay can be used to safely switch off the associated actuators on the machine or installation. SNO 4003K (-A/-C) plus (AC 115 V/AC 230 V) Intended use The SNO 4003K plus is a safety switch unit. It must only be used as part of the protection devices on machines for the purpose of personal, material and machine protection. It may only be used by competent persons and only on the machine it has been fitted and commissioned by a competent person in accordance with the operating instructions. In the event of any other use and in the event of modifications to the unit - even in the framework of fitting and installation - any claim under warranty against Schleicher Electronic GmbH & Co. KG becomes invalid. The user must carry out a risk assessment in accordance with DIN EN ISO 12100. On this basis you must carry out validation of the entire installation/ machine in accordance with the applicable standards. The quoted performance level (PL) is only reached if an average number of switching cycles per year is not exceeded, depending on the loading of the unit (EN ISO 13849-1 Table C.1) and the specific application (EN ISO 13849-1, C.2.4 and Table K.1). Using an assumed B 10d value for maximum load 400,000 we get, for example, a maximum cycle number of 400,000 / (0.1 x 30) = 133,333 switching cycles/year. Equipment and functional description The unit is a single-channel safety switch unit that is self-monitoring in every ON-OFF cycle, for emergency stop devices as per EN 60204-1, which is fitted with a positively guided relay. Switching (input circuit A1) is carried out by the supply voltage. The unit has the two reset inputs Y2 (automatic reset) or Y3 (manually monitored reset). The two relays K1 and K2 are controlled after actuating the reset button (on Y1-Y3) or automatically (bridge Y1-Y2). The release current circuits are closed after this switch-on phase and the signal current circuit is opened. If the electrical connections between terminal A1 and the supply voltage are interrupted, the release current circuits are opened and the signal current circuit is closed. The LED SUPPLY (green) shows the presence of the supply voltage. The LED K1, K2 (green) shows the status of the release current circuits. Setting up an emergency stop device according to stop category 0 is possible (EN 60204-1). The unit corresponds to category 3 for safetyrelevant parts of control systems (EN ISO 13 849-1). Competent persons The safety relay SNO 4003K plus may only be fitted, installed, commissioned and tested by compe-tent persons. A competent person is someone who... has had an appropriate technical education and has been instructed by the machine operator on operation and the applicable safety guidelines and has access to the operating instructions of the safety relay SNO 4003K plus, and has read and duly noted its content. Page 13

LED display K1,K2 (green) SUPPLY (green) SUPPLY 2x flashing SUPPLY 3x flashing SUPPLY 6x flashing SUPPLY flickers SUPPLY aus Display elements Significance Current circuit K1/K2 switched Supply voltage is present Cross-circuit Y2 to Y3 on Y1 Reset error Over-voltage only on U N 24 V DC Internal error No voltage, under-voltage Additional description see behavior in the event of a fault Allocation A1 A2 Y1 Y2 Y1 Y3 Terminal allocation Description Supply voltage U B+/L1 Supply voltage GND/N Automatic reset Manual reset 13 14 Release current circuit 1 23 24 Release current circuit 2 33 34 Release current circuit 3 41 42 Signal current circuit (not safe) Input switching Single channel operation: The safety sensor is connected between U B+ and A1 Two-channel operation: One safety sensor is connected between U B+ and A1, the second between GND and A2. Reset Manual reset: Wire the reset button with NO contact between contacts Y1 and Y3 (monitored reset). The reset button must be installed outside the danger area in such a way that it cannot be actuated from the danger area. In addition, the user must have a complete overview of the danger area when actuating. Automatic reset: Connect a wire bridge between Y1 Y2. Contactor monitoring: Contactor monitoring only becomes active in reset. Connecting the NC contacts of the switched gate in series with the reset circuit effects static contactor monitoring. Function test Function test with manual reset If the safety sensor is not actuated (e.g. emergency stop not pushed) and if the supply voltage is present, the unit is ready (LED SUPPLY lights up). After actuating the reset button, the release current circuits close or the signal current circuit opens (LED K1, K2 lights up). Actuating the sensor opens the release current circuits and closes the signal current circuit (LED K1,K2 and LED SUPPLY off) Function test with automatic reset If the safety sensor is not actuated (e.g. emergency stop not pushed) and if the supply voltage is present, the release current circuits close or the signal generator current circuit opens (LED SUPPLY and LED K1, K2 light up). Actuating the sensor opens the release current circuits and closes the signal generator current circuit (LED K1, K2 and LED SUPPLY off). Electrical installation Make the installation free from voltage! Only on 24 V DC units: The supply voltage must comply with the regulations for small voltages with safe isolation (SELV, PELV) in accor-dance with EN 60664 and EN 50178. Design the insulation of the input lines for the highest voltage! The insulation of the input lines of the supply circuit (A1/A2) and the components connected to Y1 to Y3 must be designed for the highest voltage that may occur in the unit. Operate signal and input current circuits in the same voltage range. With AC power supply and single channel switching, the maximum line length in the safety current circuit must be observed (see instructions concerning line length and technical data). All connected command generators and subsequent control systems, together with wiring and routing must comply with the stipulated category, (e.g. protected routing, individual sleeve line with screening etc.). In order to protect the safety outputs and to increase service life, the external loads must be fitted with varistors and RC elements. When doing so, remember that this will increase the response times, depending on the type of protection switching. The safety outputs and the contactor monitor (EDM) must be wired within the switchgear cabinet. To duplicate the enable circuits you can use the extension units from the SNE range or external contactors with positively guided contacts. To prevent the contacts on the fitted relays from welding together, you must select an over-current protection device or a short-circuit protector (operating class gg) according to the appropriate utilization category and integrate this in the release current circuit. Notes Operating the unit outside the specification can lead to functional errors or destruction of the unit. The units are equipped with an overload protection (in the event of a short-circuit). After elimination of the cause of the fault, the unit will be ready for operation after approx. 1.5 seconds. The control output Y1 is to be used exclusively for connecting command generators as per the instruction manual and not for connecting exter-nal consumers, such as lamps, relays or contactors. Commissioning and regular testing No commissioning without testing by a competent person! Before commissioning the installation where you are fitting a safety relay SNO 4003K plus for the first time, this must be checked by a competent person and released, with documentation of this action. Check the danger area Before commissioning you must ensure that there is nobody in the danger area. Check the danger area and secure the area against access by persons. Observe the relevant laws and local regulations. Regular testing of the protection equipment by competent persons Test the installation in accordance with the applicable national regulations at the intervals quoted therein. This is to show any changes to the machine or manipulation of the protection equipment since initial commissioning. Each safety application must be tested at the time intervals that you have stipulated. The effectiveness of the protection equipment must be checked by competent and appointed persons. If changes have been made to the machine or the protection equipment or if the safety relay has been replaced or repaired, you should test the installation again. Page 14

Function diagram SNO 4003K plus manual start with start-up block A1, SUPPLY LED Y3 K1/K2, K1/K2 LED 13/14, 23/24, 33/34 41/42 t A2 = response time t A3 = maximum switch-on time t B = readiness time t M = minimum switch-on time t R = fallback time = time required to be ready for operation again Function diagram SNO 4003K plus automatic start t W A1, SUPPLY LED Y2 K1/K2, K1/K2 LED 13/14, 23/24, 33/34 41/42 t A1 = response time t R = fallback time = time required to be ready for operation again t W Notes concerning line length Max. line length of the input circuit with alternating voltage Caution! The values for max. line capacity C L must always be maintained, otherwise the unit can react in a faulty manner. Line data Cross-section 1.5 mm 2 Capacity 150 nf/km Resistance 28 Ω/km Temperature +25 C Ring line Alternating current line not routed in parallel, max. length l r: 1 km Application examples Emergency stop application, single channel, manual start with reset button monitoring The single channel emergency stop application already fulfills the stop category 0 in accordance with EN 60204-1 and the category 2 in accordance with EN ISO 13849. The emergency stop sensor circuit is not redundant. Short-circuits to ground are detected in the emergency stop sensor circuit. Supply voltage DC 24 V Stub Max. length of stub l S and max. line capacity C L depending on supply voltage U B: U B 115 V 230 V C L 37.5 nf 7.5 nf l S 250 m 50 m Guard door application, twin channel, automatic start The twin channel emergency stop application already fulfills the requirements of stop category 0 in accordance with EN 60204-1 and the category 3 in ac-cordance with EN ISO 13849. The guard door circuit is not redundant. Short-circuits to ground are detected in the guard door circuit. Supply voltage AC 230 V Page 15

Assembly 1 Hook the relay onto the top-hat rail. 2 Snap the relay onto the top-hat rail using slight pressure in the direction of the arrow. Disassembly 3 Push the relay down in the direction of the arrow. 4 When the relay is pushed down, release it from the retainer in the direction of the arrow and remove it from the top-hat rail. Dimensions SNO 4003K plus Dimensions SNO 4003K-A/-C plus Behavior in the event of a fault DC switch-off capacity No operation in the event of unclear malfunction! The machine must be taken out of service if you cannot find a cause for a fault and safely rectify it. Observe the LED SUPPLY, the flashing code indicates possible causes of faults. Reset fault (LED flashes 3x): faulty initiation of the reset input (too long, at start already). If the fault has been rectified, the SUPPLY LED lights up permanently. After valid reset, release of circuits follows. Cross short (LED flashes 2x) cross short detection Y2 to Y3 takes place with reset request on Y1. Switch off power to the unit, rectify cross short. With correct wiring, circuits are released in accordance with the reset condition. Only 24 V DC unit: over-voltage (LED flashes 6x): switch off power to the unit, check the supply voltage. With permissible operating voltage, circuits are released in accordance with the reset condition. Under-voltage (LED off): check the supply voltage. With permissible operating voltage, circuits are released in accordance with the reset condition. Internal fault (LED flickers): the unit is defective and must be replaced. Complete function test after fault rectification! Carry out a complete function test after rectification of a fault. Also, please observe the information provided by your professional association Overview of devices / Part numbers Type Rated voltage Terminals Part no. SNO 4003K DC 24 V screw terminals, fixed R1.188.0409.1 AC 115-120 V 50-60 Hz screw terminals, fixed R1.188.0889.1 AC 230 V 50-60 Hz screw terminals, fixed R1.188.0899.1 SNO 4003K-A DC 24 V screw terminals, pluggable R1.188.0509.1 AC 115-120 V 50-60 Hz screw terminals, pluggable R1.188.0909.1 AC 230 V 50-60 Hz screw terminals, pluggable R1.188.0919.1 SNO 4003K-C DC 24 V spring terminals, pluggable R1.188.1999.0 Page 16

Technical data SNO 4003K plus Nominal voltage U N AC 115-120 V, AC 230 V DC 24 V Rated power AC 2.1 W / 3 VA DC 1 W Ripple U pp 2.4 V Nominal frequency 50... 60 Hz Operating voltage range 0.85... 1.1 x U N 0.80... 1.25 x U N Fusing for control circuit supply Short-circuit resistant Control circuit Output (Y1) Rated output voltage (Y1 on Y2, Y3) max U N (DC), min U N (DC)-2V Idle running voltage (only AC units) < 40 V Short-circuit resistant / current limiting yes / -- yes / 250 ma Inputs (Y2, Y3) Input voltage range (only on DC units) Rated current / peak current (reset inputs Y2, Y3) Times at UN Response time t A1 (reset input Y2) Response time t A2 (reset input Y3) Switch-on duration t M, t A3 (reset input Y3) Readiness time Y3 t B Reavailability time t W Reavailability time t W in the event of a fault Fallback time t R (K1, K2) Output circuit (13/14, 23/24, 33/34 NO and 41/42 NC) Relay contacts Low 5 V DC, High 15 V DC 5 ma / 20 ma max. 600 ms max. 70 ms 50 ms - 5000 ms max. 400 ms max. 200 ms max. 1.5 s max. 80 ms Release current circuits (NO), safety-relevant 3, positively guided Signal generator circuits (NC) not safety-relevant 1, positively guided Nominal switching voltage U n AC 230 V / DC 300 V (see illustration DC switch-off capability) Max. steady current I n per current path 8 A Max. total current of all circuits DC 24 V 12 A AC 115-120 V, AC 230 V 8 A Use category as per DIN EN 60947-5-1 AC-15: U e 230 V, I e 5A DC-13: U e 24 V, I e 5A Contact fusing, gg or max. 8 A Line protection switch characteristic B or C > 10 7 switching cycles General Data Contact protection in accordance with DIN EN 60664-1, EN 60947-1 Rated surge voltage 4 kv Over-voltage category II Rated voltage AC 300 V Test voltage U eff (50 Hz) 2 kv Protection rating housing/terminals as per DIN EN 60529 IP 40 / IP 20 Ambient/storage temperature -25... +55 C / -25... +75 C Weight 0,25 kg Terminal and connection data Single wire/fine wire 1 x 0.14 mm² - 2.5 mm² / 2 x 0.14 mm² - 0.75 mm² Stripped length max. 8 mm Fine wire with core ferule as per DIN 46228 1 x 0.25 mm² - 2.5 mm² / 2 x 0.25 mm² - 0.5 mm² Maximum tightening torque 0,5 Nm - 0,79 Nm Connection cross-sections for UL and CSA applications AWG 26 14: only Cu lines to be used; 60 C / 75 C Max. tightening torque for UL and CSA applications 5 7 lb in (0,56 0,79 Nm) General system data Safety integration level SILCL2 (EN 62061) Safe Failure Fraction (SFF) 90 % (EN 62061) Hardware fault tolerance (HFT) 0 (EN 62061) Category Category 3 (EN ISO 13849-1) Performance Level PL d (EN ISO 13849-1) DCAVG 90 % MTTFd 100 years B 10d - value (relay) AC-15, 230 V, I = 5 A DC-13, 24 V, I = 2 A I = 1 A 300 10 3 switching cycles 2 10 6 switching cycles 7 10 6 switching cycles PFHd 2 x 10 7 TM (use duration) 20 years (EN ISO 13849) Stop category 0 (EN 60204-1) Page 17