EP/2 Installation Instructions

Similar documents
Ethernet Adapter Installation Instructions

Custom Controller Installation Instructions

NSD/M1 Installation Instructions

Infosystem Remote Touchscreen Installation Instructions

Rack Input Module Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions

NovarNet Interface Module Setup Instructions

Analog Output Module Installation Instructions

Envoi Installation and Setup Instructions

Upgrading an EP/2 to a Lingo SE

rcc.1081 Installation Instructions

ETM-2040 Service Manual

ETM-2050/ETM-2051 Service Manual

ETM-2020/ETM-2024 Installation Instructions

Installing Sentor. Hardware Installation

Installation & Operation Guide

Case Management System Installation Instructions

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

6222 Two Door Module Technical Operations Manual

Quick Start Installation Guide

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installing the DX LCD Display

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

TRC-190 User s Manual

BA/BS4S Temperature Sensor Installation & Operating Instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

PanelView Plus/VersaView CE Terminals and Display Modules

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

E600 VX01 Installation guide

Installation & Operation Guide

Software Package Installation Instructions

FLEX Ex Spring Clamp Terminal Base

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

Copy Machine Reader. Installation and Setup Guide

OilCop Component Wiring Installation Manual

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Hawki Advanced HyperTerminal Installation Instructions

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

PIX 535. PIX 535 Product Overview CHAPTER

TRC-190 User s Manual

PIX 520. PIX 520 Product Overview CHAPTER

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SERVICE MANUAL MODEL SSW-520-F

SERVICE MANUAL. MODEL SSW-321-Fr1

V TU24 V350-J-TU24

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

APP 700 Technical Specification

Upgrading and Servicing Guide

Installing and Setting Up the Components

NT1B-300 Rack Installation Instructions

24/48/120 VAC Interface Card Instruction Manual

OPLC Installation Guide

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Prisma II Platform. Optoelectronics

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

SNAP-IT-PM Installation Guide

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

EMS467 Monitoring System. Installation and Operations Manual Section 40

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Data Isolation Cards. ADSL High Voltage Isolation Card. Single Line Voice Isolation Card With CID, CW & MWI. Floated 130VDC or 120VAC Input P30121

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

FX Input/Output (I/O) Modules XM07 and XM14

clarity 3 Programmable Controller

Six-Slot T1 Mini-Repeater Apparatus Case

SERVICE MANUAL MODEL SSW-321-D

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

SERVICE MANUAL MODEL SSW-521-D2-ADA

Dell SC7020 Storage Controller Getting Started Guide

Carbon Monoxide Sensor - ModBus

2-Way Wireless I/O Expander Installation Guide

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Installation Instructions

Installation and Operation Guide

H704-42(H)(E), H704-42/1(H)(E)

Installation and Operation Guide

SNAP-IT-1U Installation Guide

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Transcription:

1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A.

Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL 916, Energy Management Equipment, and is listed by Underwriters Laboratories, Inc., for installations in the United States. This device has been tested and found to be in compliance with the requirements set forth in C22.2, No. 205-M1983, Signal Equipment, and is Certified by Underwriters Laboratories, Inc., for installations in Canada. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. Novar Controls Corporation makes no representations or warranties with respect to this manual. In no event shall Novar Controls Corporation be liable for technical or editorial omissions or mistakes in this manual, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this manual. Copyright 2004 by Novar Controls Corporation. All rights reserved. No part of this manual may be reproduced in any form or by any means without prior written permission from Novar Controls Corporation. Novar Controls Corporation 6060 Rockside Woods Blvd., Cleveland, OH 44131 Tel: 800.348.1235 www.novarcontrols.com

Description The EP/2 is the second generation Executive Processor for the Logic One Building Management System. The EP/2 manages network communications, monitors and logs the operations of the local control modules, and provides expandable and complete integrated data control of the building s equipment. It also has local area network (LAN) capability and offers the option of a built-in 3.5-inch, high-density floppy drive. This document provides instructions for mounting the EP/2 s baseplate, installing the electronics assembly, and making the proper wiring connections. EP/2 Specifications Agency Approvals Listed device: Standards used: Power Requirements Voltage: Consumption: Operating Environment Temperature: Humidity: Physical Dimensions Height: Width: Depth: Weight: CUL/UL E90949 UL 916, Energy Management Equipment CSA C22.2, No. 205-M1983, Signal Equipment 24 VAC 30 VA 32 to 140F(0 to 60C) 0 to 95% Relative, noncondensing. 22.25 inches 13.3 inches 2.5 inches 12.0 lb (All aluminum enclosure) Precautions Take the following precautions during installation: Observe all national and local electrical codes. Connect 24-VAC power wiring to the terminals marked 24 VAC only. Connection to other terminals will damage them. Make sure that the 24-VAC power wiring is connected to a dedicated transformer. No other devices should be supplied power by the transformer connected to the EP/2. Do not ground the transformer for this module on the secondary side. Do not connect the EP/2 to a Module Power Supply. Make sure that the EP/2 power cannot be switched off accidentally. The EP/2 requires continuous power for proper operation. Do not use the EP/2 as a final safety device. DOC. #569011000 A 7/30/04 1

Mounting the EP/2 Baseplate NOTE! The EP/2 must be mounted in an accessible location with the top of the assembly no higher than 6 feet from the floor. Use hollow-wall anchors when mounting the baseplate to paneling or drywall to ensure a secure mount. Use the following procedure and refer to Figure 1, as necessary, to mount the baseplate to the wall. Step Procedure 1 Loosen the two screws at the bottom of the EP/2 with the hex wrench and lift off the cover. 2 Position the baseplate against the wall and mark the wall to show the location of the four slotted holes in the baseplate. 3 Drill the holes and, if necessary, install the hollow-wall or other appropriate anchors. 4 Insert screws into the fasteners until approximately 1/4-inch remains between the wall and the head of each screw. 5 Position the baseplate over the screws and slide it down until the screws move into the slots. 6 Tighten the screws to secure the baseplate. EP/2 Baseplate Slotted Mounting Holes Figure 1. Slotted mounting holes on the EP/2 baseplate 2 DOC. #569011000 A 7/30/04

Wiring the EP/2 Supplying the EP/2 with Power The EP/2 is powered by a 24-VAC, Class 2, Transformer Kit (not included; the transformer kit must be purchased separately). It must be installed not more than 50 feet from the EP/2 (using minimum 18-gauge wire). CAUTION! Use a dedicated transformer. Do not connect any other devices to the transformer. Do not connect the EP/2 to a Module Power Supply. Use the following procedure and refer to Figure 2, as necessary, to install the 24-VAC, Class 2, Transformer: Step Procedure 1 Connect the blue and yellow leads from the transformer secondary to the screw terminals labeled 24 VAC, Class 2, located on the EP/2 terminal board. 2 Connect the transformer primary leads (white/black) to a 120-VAC source. 3 Connect the GND terminal to a suitable earth ground. 4 Apply power to check the voltage at the 24-VAC terminals. Voltage should be approximately 25 28 VAC. 5 Turn off the power until needed. NOTE! The EP/2 requires continuous power for proper operation. Make sure the EP/2 power cannot be switched off accidentally. Wiring the EP/2 Inputs and Outputs Refer to Figure 2 when wiring the EP/2 input/output connections. All digital inputs should be dry contact closures. Outdoor Light Sensor This input can support either a 4 20 ma analog sensor such as the Novar Controls Analog Light Sensor (ALS) or a standard digital contact closure sensor. Connect the sensor to the terminals labeled Outdoor Light Sensor Input according to the instructions supplied with the sensor. DOC. #569011000 A 7/30/04 3

Outdoor Temperature Sensor This input can support any standard 4 20 ma sensor with a 40F to 120 F range. Novar Controls recommends its Outdoor Temperature Sensor. Connect the wiring from the sensor to the terminal labeled Outdoor Temperature Sensor Input according to the instructions supplied with the sensor. Demand Pulse Connect the isolated contacts of a pulse-type utility meter or watt transducer to the terminals labeled Demand Pulse Input. The EP/2 baseplate is shipped with a capacitor on it (Terminals 5 and 7). Leave the capacitor in place unless the demand pulse is expected to exceed 5 pulses per second. This capacitor filters out electrical noise. Phase Loss Sensor Connect a normally open, dry contact output of an electrical phase loss monitor to the terminals labeled Phase Loss Input. Emergency Status Input Connect a normally open, dry contact output of an emergency monitoring system to the terminals labeled Emergency Status Input. Output X Under normal operating conditions, a normally open solid state contact is held closed. It opens for 0.5 seconds upon the occurrence of system alarms, load alarms, or monitoring alarms that have Unit Fault programmed as active. This signal can be used to indicate an EP/2 fault alarm. RS-232 PORT 20 1 NOVAR CONTROLS CORPORATION EXECUTIVE PROCESSOR 2 TRANSITION BOARD 37 19 TELEPHONE LINE OUTDOOR LIGHT OUTDOOR TEMP SENSOR SENSOR INPUT INPUT DEMAND PULSE INPUT PHASE LOSS INPUT EMERGENCY STATUS INPUT OUTPUT X 24V, 1A CLASS 2 POWER INPUT 24VAC CLASS 2 30VA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RS-485 COMMUNICATION NETWORKS CLASS 2, 5V MAX CIRCUITS 'A' MODULE DIRECTION 'B' MODULE LAN DIRECTION 15 SHIELD SHIELD SHIELD 16 17 18 19 20 21 22 23 24 25 26 27 28 Figure 2. EP/2 terminal strip (transition board) 4 DOC. #569011000 A 7/30/04

Module Communications A maximum of 32 modules can be connected to each of the A or B Module terminals using the recommended network cable (Belden 8761, Novar Controls WIR-1010, or equivalent). Use the following procedure to make the connections. Step Procedure 1 Connect the black wire from the network cable to the negative ( ) terminal. 2 Connect the shield/drain wire to the Shield terminal. 3 Connect the red wire to the positive (+) terminal. Slave Communications Connect the communications cable (Belden 8761, Novar Controls WIR-1010 or equivalent) from the slave EP/2s to the LAN terminals, using the following procedure. Step Procedure 1 Connect the black wire from the cable to the negative ( ) terminal. 2 Connect the shield drain wire to the Shield terminal. 3 Connect the white wire to the positive (+) terminal. Communication Direction There are two Direction terminal locations on the terminal board: Terminals 18 and 19 (located between the A and B module terminals) are for module communications. Terminals 26 and 27 (to the right of the LAN terminals) are for slave communications. These connections provide an interface to other types of media such as fiber-optic networks (that do not have full-duplex capability) to allow the EP/2 to manage the switching of send and receive signals when communicating using these media. Installing the EP/2 Electronics Assembly The following items are needed to install an EP/2 electronics assembly: The EP/2 electronics assembly The hardware kit (containing a small jumper block and a hex wrench), included with the electronics assembly DOC. #569011000 A 7/30/04 5

Use the following procedure to install the electronics assembly on the baseplate. Step Procedure 1 Place the electronics assembly face down on a clean sturdy area. 2 Remove the jumper block from the hardware kit. 3 Position the small jumper block over the battery backup jumper leads (see Figure 3) and carefully push into place. Battery Jumper Access Address Switch (Eight Dipswitches) Figure 3. Back of the EP/2 electronics assembly 4 Set the address switch (eight dip switches located on the back of the EP/2, see Figure 3) as follows: If the EP/2 is to be programmed to function as the master, set the address switch to 0 as indicated in Figure 4. If the EP/2 is to function as a slave, set the address switch to the appropriate address setting from 1 to 31. NOTE! For EP/2 PROM version 18.23 or higher, make certain Address Switches 6, 7, and 8 are set to the on position or the address will be incorrect. 5 Slide the EP/2 assembly over the lip at the top of the baseplate and down over the mounting posts. 6 Guide the DB37 connector on the EP assembly over the corresponding connector on the transition board (terminal strip). 7 Tighten the two retaining screws (using the hex wrench supplied) to secure the EP/2 assembly to the baseplate 6 DOC. #569011000 A 7/30/04

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Figure 4. EP/2 address settings RS-232 Port Network Communications Changing the EP/2 Communication Ports Permanently The RS-232 direct-connect port is a DB9 connector located to the left of the DB37 connector on the EP/2 electronics assembly. This port can be used to connect the EP/2 directly to a laptop or personal computer (PC) via an RS-232 adapter cable (Novar Controls Part. No. 600540000) or to connect the EP/2 to a serial printer via a special cable. (Call Novar Controls Corporation s Technical Support if this cable is needed.) The Network Communication Port is a DB37 connector located to the left of the RS-232 port on the electronics assembly. This port is compatible with many of the existing LAN networks. Connect the LAN adapter module to this port. When an EP/2 contains PROM Version 18.26 or higher, the local area network (LAN), modem, Ethernet addresses, and RS-232 port definitions can be permanently adjusted if the EP/2 is put into a special Setup Mode. When changes are made in the Setup Mode, the settings are maintained even when the memory of the EP/2 is cleared. This allows the EP/2 to maintain communications to accommodate a download. The following procedure should be used to make the changes. DOC. #569011000 A 7/30/04 7

Step Procedure 1 Remove the EP/2 electronics from the baseplate if it has already been installed. 2 Write down the positions of the EP/2 address switches. The address must be reset once the changes have been made. 3 Move all of the address switches to the off position (Address 255). 4 Plug the EP/2 onto its baseplate. 5 Make sure that the unit number shown on the opening menu of the keypad is 256. 6 Press the appropriate keypad numbers to enter the access code. Use access code 1234 if the unit is dumb. 7 Use the keypad to access the Tools display and select EP/2 Configuration. 8 Set the LAN to NovarNet or Master-Slave and press enter. 9 Define the modem as Novar-202 or Novar-212 (Hayes Compatible) and press enter. The modem type selected must match the modem type installed on the EP/2. 10 Adjust the RS-232 port and Ethernet parameters, if necessary, and press enter. NOTE! The RS-232 port at some download levels can be set to 38.4K if the PC communications port will support it. 11 Press Clear until the system returns to the sign-on screen. 12 Remove the EP/2 from its baseplate and return the address switches to their original settings. 13 Plug the EP/2 back onto the baseplate. NOTE! If the EP/2 does not have a keypad, Remote Keypad Software (RKS) can be used to access and adjust the EP/2 during the Setup Mode. 8 DOC. #569011000 A 7/30/04

Connecting to the Telephone Network Thread the telephone cable through the knockout on the side of the baseplate. With the tab pointing toward the wall, insert the telephone line into the telephone jack on the EP/2 transition circuit board. A telephone interface jack is required at the installation site. The jack is supplied by the telephone company and should be type RJ-11C. The switched-telephone network can be either rotary dial or touch-tone. If communication between the EP/2 and the PC workstation takes place over long distance lines (toll call) using a long distance calling service (such as MCI or Sprint), check with that long distance service organization to determine what kind of switched-telephone network is required. No voice capability or additional equipment is required. Checking Installation Make sure that the installation is complete. Check all wiring connections to make sure that they are secure. Reinstall the EP/2 baseplate cover and turn on the power to the EP/2. The EP/2 Model with the keypad has an 8-line by 40-character liquid crystal display (LCD) with a backlight. The first line of the display (Figure 5) should show a random time, date, outside temperature (or asterisk), and unit of measurement (degrees). The screen should also show product information and the message System Check in reverse type. 12:00 AM 10/11/98 * Degrees Novar EP/2 MOD:00 Copyright (C) 1998 Novar Controls Corporation SYSTEM CHECK ENTER ACCESS CODE: Figure 5. EP/2 Start-up Display Screen NOTE! The EP/2K comes with a keypad and display. Monitoring on all other models must be performed via the Novar Controls software at the PC workstation or an auxiliary terminal connected to the RS-232 port on the EP/2. If this information does not appear on the display, the EP/2 is not operating properly. Contact the appropriate Novar Technology Center (NTC) or Novar Controls account representative. DOC. #569011000 A 7/30/04 9

Refer to the Novar Controls EP/2 Keypad and Display Instructions (Doc. No. 560119000) for information about accessing the display to monitor and/or make configuration changes. Model and Part Numbers Use the part numbers shown in Table 1 to order the EP/2 and its accessories. Table 1. Novar Controls Part Numbers PRODUCT MODEL NO. PART NO. EP/2 Baseplate EP/2-BPL 735100000 EP/2 Electronics (no options) EP/2 with Keypad EP/2 with Hayes-compatible modem EP/2 with Novar Controls modem EP/2 with 3.5-in. disk drive and keypad EP/2 with Hayes-compatible modem and keypad EP/2 with Novar Controls modem and keypad EP/2 with Hayes-compatible modem, 3.5-in. disk drive, and keypad EP/2 with Novar Controls modem, 3.5-in. disk drive, and keypad EP2 EP/2K EP/2S EP/2M EP/2DK EP/2KS EP/2KM EP/2DKS EP/2DKM 735000000 735007000 735008000 735005000 735003000 735004100 735004000 735001100 735001000 Ethernet Adapter for the EP/2 EP/2-EA 735090000 24 VAC, Class 2 Transformer Kit 24V-XFR 730090000 Analog Light Sensor ALS 708100000 Outdoor Temperature Sensor (for EP/2 or Savvy) EIA-232 Controller Direct Connect Cable for Savvy, EP/2 (RS-232 Adapter Cable) OTS/2 735070000 600540000 10 DOC. #569011000 A 7/30/04