TOMOHD. Product Specifications

Similar documents
Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

DAILY LINAC QA BEAM QA

ph fax Deming Way Middleton WI USA

ADVANCING CANCER TREATMENT

Data. ModuLeaf Mini Multileaf Collimator Precision Beam Shaping for Advanced Radiotherapy

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Machine and Physics Data Guide

CYBERKNIFE M6 SERIES. Technical Specifications

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

ADVANCING CANCER TREATMENT

Quality assurance of a helical tomotherapy machine

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

FAST, precise. qa software

DICOM Conformance Statement

Raising the Bar in IMRT QA

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

A NEW LASER FOCUS ON PATIENT SAFETY

Version 5.6. Quick Start Guide

Photon beam dose distributions in 2D

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

3D Scanning Comes Full Circle

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Basic Radiation Oncology Physics

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

SRI GURU RAMDAS INSTITUTE OF MEDICAL SCIENCES & RESEARCH MEHTA ROAD, VALLAH, SRI AMRITSAR

Initial Clinical Experience with 3D Surface Image Guidance

Multi-Purpose Body Phantom

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

UNCOMPROMISING QUALITY

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Fits you like no other

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

Fits you like no other

Advanced Radiotherapy

Real-time monitoring of linac performance using RT plans and logfiles

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Mediso AnyScan. Single-Head and Dual-Head SPECT

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071

PRODUCT DATA. Advanced 128

O-ARM IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

The MSKCC Approach to IMRT. Outline

Design approach for a Highly Accurate Patient Positioning System for NPTC

Quick Reference Datasheet For All RIT113 Packages

Financial disclosure. Onboard imaging modality for IGRT

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

REF User Manual DOC # STANDARD IMAGING, INC Deming Way Middleton, WI

DX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300

Introduction to Biomedical Imaging

MEDICAL IMAGING 2nd Part Computed Tomography

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

DX-D 300. Flexible Direct Radiography System

Mediso AnyScan S Single-Head and Dual-Head SPECT

Quality Assurance for Tomotherapy Systems

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Fujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

IHE Radiation Oncology Technical Framework Supplement. Treatment Delivery Plan Content (TDPC) Rev. 1.1 Trial Implementation

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Ch. 4 Physical Principles of CT

Solid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning

FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

DX-D 300. Flexible Direct Radiography System

FocalSim DICOM Conformance Statement. Table of Contents:

SCENARIA 64-Slice CT Putting Advanced CT Within Reach.

Particle Beam Therapy System

PrecisePLAN 2.00 Import

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Computational modelling and analysis: IOP Medical Physics Group

Corso di laurea in Fisica A.A Fisica Medica 4 TC

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

Equipment Specification

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy

LaserTowerPRO CM 3D MARKING AND ENGRAVING SYSTEM. LaserTower COMPACT 3D LASER MARKING SYSTEM. LaserTower COMPACT 3D LASER MARKING SYSTEM

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Transcription:

TOMOHD Treatment System Product Specifications

1. Complete Treatment System Dimensions Height Width Length Weight 8 ft., 3.25 in. (252.1 cm) 9 ft., 2.50 in. (280.6 cm) 15 ft., 2.25 in. (463.0 cm) 10,000 lbs. (4,536 kg) Lateral View: System and minimum room dimensions Forward View: System and minimum room dimensions 02 TomoTherapy: TomoHD Product Specifications

Top View: System and minimum room dimensions 2. Installation Minimum room size - requirements Height Width Length Typical schedule (receipt of system to first treatment) Commissioning 8 ft., 10.13 in. (269.6 cm) 15 ft., 2.00 in. (462.4 cm) 19 ft., 6.75 in. (596.2 cm) 30 days, although completion has been achieved within two weeks Integrated system completely pre-commissioned in the factory and re-verified at customer site 3. Treatment Vault Environment SPECIFICATION Line voltage, VAC Ambient room temperature Relative humidity REQUIREMENTS 480 volts, 3-phase; others may be supported 68-75 degrees Fahrenheit (20-24 degrees Celsius) 30% - 60%, noncondensing TomoTherapy: TomoHD Product Specifications 03

4. Mechanical Features SPECIFICATION Gantry Degrees of rotation Direction of rotation Rotational angle accuracy Speed of rotation Controls Source to axis distance Mechanical to radiation isocenter offset Mechanical isocenter stability Position indicators Isocenter height Cooling PERFORMANCE Rotates around IEC-y axis, continuous rotation Clockwise viewed from the foot of the couch Within 0.5 degrees Varies; dependent upon plan Rotational speed set during treatment planning 85 cm Included in beam model (within accuracy 0.25 mm) < 0.4 mm 5-axis laser system 113 cm typical (dependent upon finished flooring) Integrated onboard cooling system eliminates need for facility-chilled water loop 5. Photon Beam SPECIFICATION Accelerator type Length Microwave Power Source Nominal dose rate at Dmax** Nominal Dmax** PERFORMANCE Standing Wave 0.3 meters 2.5 MW Magnetron 850 cgy/min 1.5 cm Percentage depth dose at 10 cm** Typical 61.4% Number of beamlets Plan dependent; system capable of efficiently delivering tens of thousands of beamlets which allows for very high fidelity intensity modulation Nominal energy 6 MV, single energy Nominal spot size 2 mm Penumbra of treatment beam - IEC-y axis The 80% - 20% penumbra widths are approximately 4.9 mm, 4.6 mm, and 4.1 mm (respectively for the 5.0 cm, 2.5 cm, and 1.0 cm field widths). Field size range at isocenter Selectable 1.0 cm x 0.625 cm to 1.0 cm x 40 cm 2.5 cm x 0.625 cm to 2.5 cm x 40 cm 5.0 cm x 0.625 cm to 5.0 cm x 40 cm Maximum radiation field length 150 cm with Couch at height of isocenter plane Treatment volume - TomoHelical 80 cm (transverse diameter) x 135 cm (longitudinal) for typical patient set-up; Actual treatment volume length is variable depending upon couch height; Note: Region of treatment used is determined by the planning CT image field of view (FOV) Provided the FOV is 80 cm or less and all patient anatomy is present in the planning image, the TomoHD system can import the image, plan, and treat. Treatment volume - TomoDirect 40 cm (transverse diameter) x 135 cm (longitudinal) for typical patient set-up; Actual treatment volume length is variable depending upon couch height. ** Performance based on 5 cm field size at SSD=85 cm. 04 TomoTherapy: TomoHD Product Specifications

Linear Accelerator (Linac) Integrated Shielding Target Primary Collimator Jaw Collimator Multileaf Collimator Accelerator and collimator subsystems Average MLC leakage Primary collimation Jaw collimation Travel range Axis of travel Speed of travel Basic dimensional description Multileaf collimation Number of leaves Basic dimensional description Mode of operation Axis of travel Speed of travel Resolution Leaf drive mechanism Position indicator 0.25% (typical) Tungsten block with rectangular, fixed aperture 1.0 cm - 5.0 cm treatment field width at isocenter IEC-y Selectable fixed primary collimation widths set at the start of a given treatment 13.5 cm tungsten thickness 64 binary interlaced leaves (tongue and groove side profile) 10 cm leaf thickness in beam direction Binary leaves either fully in or fully out of beam path 1 axis, longitudinal direction (IEC-y) Binary leaf state changed within 20 msec 0.625 cm leaf widths in IEC-x direction at isocenter Pneumatic Continuous monitoring with interlock, checks that leaves open and close at correct time TomoTherapy: TomoHD Product Specifications 05

6. Dosimetry SPECIFICATION PERFORMANCE Chamber type Full beam transmission, hermetically sealed dual chamber Precision Within 1% Linearity Within 1% Variation of dose rate vs. gantry angle Within 2% Beam-off interlocks Radiation System; Dose Monitoring, Patient Table Position; Gantry Angle; Computer Communications; Vault Door; Facility E-stops 7. CTrue Imaging SPECIFICATION PERFORMANCE Geometry Fan-beam Dose per MVCT image (typical) 0.5-3 cgy depending on resolution and body thickness Detector configuration 528 channels, single-row xenon ion chamber array used for image acquisition Image resolution (xy) 512 x 512 (0.78 mm pixels) Slice spacing available 2 mm, 4 mm, 6 mm Scan time Typically 2 minutes per 10 cm length at 4 mm slice spacing Field of view (FOV) 40 cm diameter Source to detector distance 145 cm Isocenter to detector distance 60 cm Image noise 2% - 4% Image uniformity Within 2.5% Spatial resolution Nominal 0.5 lp/mm at 10% MTF Contrast resolution 2% density for 2 cm object (typical) Image reconstruction algorithm Filtered backprojection Image reconstruction time Real-time; slice-by-slice at time of acquisition Image registration tools MVCT/kVCT image overlay with adjustable checkerboard; manual or automatic registration (maximization of mutual information) using bone and/or soft tissue; translations and pitch/roll/yaw determination Application of adjustments obtained Translations applied via couch, roll applied via gantry via image registration Frequency of correction for geometry flexion None required; rigid ring gantry platform Image guidance mode Daily 3D MVCT matched with 3D kvct 06 TomoTherapy: TomoHD Product Specifications

Prostate visibility No high-z artifact Multi-planar image overlay Overlay images, structures, dose Common imaging and treatment subsystem 8. Safety Features Integrated treatment planning: Planning and treatment systems use a common database Integrated quality assurance: Patient-specific QA via a dedicated application on the planning station Integrated R&V: Built-in record and verify in addition to DICOM compliant MOSAIQ and Aria interfaces Single database: Common database for planning, imaging and treatment data No plan data transfer: Planning data retrieved by treatment system from common database Common imaging and treatment beam source: Imaging geometry consistent with treatment geometry (imaging and treatment source are the same), thus avoiding the need for repeated geometric calibration of 2 different sources Fully enclosed gantry: Integrated gantry enclosures protecting the patient from beam delivery system components No auxiliary beam collimation: Integrated binary MLC (multileaf collimator) provides all beam collimation and modulation, removing the possibility of incorrect component installation and maintaining maximum physical patient clearance; also reduces handling of hazardous material No bending magnet: No beam bending required, therefore eliminating the possibility of geometry errors resulting from redirection of the beam No electron mode: The treatment system cannot be set to an unintended mode of delivery (note that helical IMRT with 6 MV x-rays can be planned to deliver treatments similar to electron mode treatments) Full system integration: Level of system integration results in software for all components being designed and tested in unison, reducing concerns of disparate system interfaces and compatibility concerns across products and across companies TomoTherapy: TomoHD Product Specifications 07

STANDARD SYSTEM 9. TomoHelical Treatment Delivery Mode The TomoHelical delivery mode provides IMRT and 3D CRT treatment delivery in a continuous (360 ) helical pattern, using thousands of narrow beamlets, which are individually optimized to target the tumor. The TomoHelical mode maximizes conformality and uniformity of dose to the tumor while minimizing exposure to healthy tissue. The user is able to create a treatment plan that defines dose goals and constraints for target and avoidance structures, the level of modulation for the plan, as well as the fractionation schedule. During treatment delivery, the linear accelerator completes multiple 360 rotations around the patient while the couch passes through the bore of the system, initiated by a single turn of the operator console key. The gantry rotates around the patient in TomoHelical delivery mode, delivering radiation in a continuous spiral pattern Targets of up to 135 cm in length* can be treated, with no need to reposition the patient and with no field junctioning. 10. TomoDirect Treatment Delivery Mode The TomoDirect delivery mode is a discrete angle, non-rotational delivery mode. TomoDirect allows creation of treatment plans that include between 2 and 12 target-specific gantry angles. It also allows the user to define the level of modulation for the plan, including a 3D delivery mode. Treatment planning is completed rapidly due to the power of the system s computing platform. During treatment delivery, all beams for each target are delivered sequentially with the couch passing through the bore of the system at an appropriate speed for each gantry angle. The complete treatment delivery is initiated by a single turn of the operator console key. 2 12 discrete gantry angles can be used in TomoDirect delivery mode Targets of up to 135 cm in length* can be treated, with no need to reposition the patient and with no field junctioning. 11. High Performance Couch The High Performance Couch, with Medical Intelligence indexing system, provides sub-millimeter accuracy and precision in point-to-point and translational positioning. Clinical workflow is enhanced with ergonomically designed dual Couch Control Keypads mounted to each side of the couch. The Couch Control Keypads allow motorized patient position modification in the X, Y and Z directions with simple, single-handed operation. The custom patient couch has a high strength carbon-fiber top with an indexing system designed to accommodate immobilization systems from multiple vendors. See High Performance Couch brochure for additional specification information. 12. Laser Positioning System The TomoHD System configuration includes stationary green lasers for virtual isocenter and moveable red lasers for patient positioning and registration. * Typical patient set-up; Actual treatment volume lengths are variable depending upon couch height. 08 TomoTherapy: TomoHD Product Specifications

13. Computing Hardware Includes the following items, housed in a rack enclosure (dimensions: 59 /150 cm H x 26 /66 cm W x 38 /97 cm D): The VoLO System for dose calculation and optimization during treatment planning. VoLO technology comprises a computer node with high-performance Graphics Processing Units (GPUs), coupled with Accuray s Non-Voxel Broad Beam (NVBB) algorithm; The Data Server and Storage Area Network (SAN), which stores data required to run the treatment system and deliver prescribed treatments to the patient. It also stores patient planning information (CT images, contours, dose volumes, and plans). The Data server is connected to the Optimization Server, Planning Stations, Operator Station and the Treatment Delivery System; The TomoGateway system hardware enables remote system diagnostics and monitoring by Accuray Technical Support (note: additional software may be required); Tape drive system for database backup; KVM and LCD display for administration of the Optimizer/Data Server assembly; Uninterruptible Power Supplies (UPS) to support the complete Optimizer/Data Server assembly; Network switch and firewalls. 14. Planning Stations Two TomoTherapy Planning Stations allow the definition and management of treatment plans and initiation of plan optimization. Delivery Quality Assurance (DQA) tools are also integrated into the Planning Station software. The Planning Stations further include the Data Management System application software, for archiving and management of patient data. An Uninterruptible Power Supply, high-resolution LCD monitor, keyboard, mouse, and required cables are included with each Planning Station. A color printer for printing treatment plans and reports is also included. An optional third Planning Station is available for purchase. 15. Operator Station One TomoTherapy Operator Station, which connects to the TomoHD Treatment System database and provides control of CTrue MVCT imaging, patient treatment and quality assurance delivery, and basic record & verify functionality. The Operator Station is provided with a color printer capable of printing CTrue images and treatment data, plus an LCD monitor, keyboard, mouse, and required cables. 16. Remote Software Solutions - Remote Planning and TomoPortal Remote Planning securely and easily provides fully functional operation of the TomoTherapy Planning Station application from outside of the TomoHD Treatment System network, via the internet. It allows a remote user to operate the Planning Station application and develop plans without being physically present in the facility where the TomoHD Treatment System is installed. The TomoPortal application also resides on the same Remote Software Solutions computer node as the Remote Planning application. The TomoPortal Remote Viewer securely and easily provides a web-enabled link to patient information stored in the TomoHD Treatment System. It is possible to review a plan, registration, and treatment data from down the hall or across a continent. The standard configuration includes server computer hardware and both Remote Software Solutions - Remote Planning and TomoPortal with licensing required for one (1) remote planning user and up to two (2) concurrent TomoPortal users. Options to purchase up to two additional Remote Planning licenses and up to six additional TomoPortal Remote Viewer licenses are available TomoTherapy: TomoHD Product Specifications 09

Hospital Network Patient Archives DICOM-RT Import DICOM-RT Export Planning CT Import Oncology IS Patient Data Transfer Standard system interfaces 17. Standard System Interfaces OIS Connect Software The OIS Connect software provides the ability to interface a TomoHD Treatment System to a compatible Oncology Information System (OIS). The software facilitates greater integration of the TomoHD Treatment System into the radiation oncology department, by: Allowing scheduling of TomoTherapy treatments on the OIS; Providing automatic capture of TomoTherapy procedures on the OIS; Aiding in charge capture and billing (where applicable); Aiding in integrating TomoTherapy treatments into patients electronic medical records, via the OIS. The OIS Connect software is based on DICOM-RT Worklist communication, as specified in DICOM Supplements 74 and 96. DICOM Export The DICOM Export Data Services Package allows the following DICOM objects to be sent from the TomoHD Treatment System to third-party systems and clinical/research databases: DICOM-CT Image Set DICOM-RT Structure Set DICOM-RT Dose DICOM-RT Plan 10 TomoTherapy: TomoHD Product Specifications

Network Data Storage This feature allows patient archives created on the TomoHD Treatment System to be sent to, or retrieved from, a storage location outside of the treatment system network. Network Data Storage provides configuration of the system firewall, workstation configuration and FTP system set up for data transfer via network. Patient Data Transfer Patient Data Transfer allows the transfer of patient data from the TomoHD Treatment System upon which it is installed, to another TomoTherapy treatment system. Patient Data Transfer provides configuration of the system firewall, workstation configuration and FTP system set up for data transfer via network, and an external USB hard drive for physical data transfer. 18. Quality Assurance QA Package (Plan quality assurance) The standard QA package includes quality monitoring and performance testing phantoms. Components include the following: One Slit Beam Virtual Water; One TomoTherapy Phantom & Holder ( Cheese Phantom ) with Density Plug Set; 12 density plugs are included, representing the following materials: LN-300 Lung, LN-450 Lung, Adipose, Breast BR12, Brain, CT Solid Water, Liver, B200 Bone Mineral, CB2-30% CaCO3, CB2-50% CaCO3, Cortical Bone and Inner Bone; Two Calibrated Mini Ion Chambers, and approximately 59 (18 m) Interconnect Cables; One Calibrated CT Slice Ion Chamber, Buildup Cap and Jig. TomoTherapy Quality Assurance (TQA ) Total Package (Machine quality assurance) The TQA application is a calendar-based productivity tool that simplifies the collection and analysis of machine performance data for the TomoHD Treatment System. The application leverages internally-generated data to provide results quickly and easily. The TQA application offers trending and reporting of many system and dosimetric parameters that allow physicists to monitor the performance of the TomoHD System. All data may be exported. The Total Package includes the base TQA package, Enhanced Dosimetry package, Longitudinal Beam Profile package, and the LINAC Alignment package, plus the TQA Step-Wedge Phantom. See TQA brochure for more information. 19. Installation Services Includes: Pre-installation Site Planning and Project Management services; Installation and commissioning; Completion of Acceptance Test Procedure (ATP) and system handover. TomoTherapy: TomoHD Product Specifications 11

UNITED STATES ASIA EUROPE Accuray Corporate Headquarters 1310 Chesapeake Terrace Sunnyvale, CA 94089 USA Tel: +1.408.716.4600 Toll Free: 1.888.522.3740 Fax: +1.408.716.4601 Email: sales@accuray.com TomoTherapy 1240 Deming Way Madison, WI 53717 USA Tel: +1 608 824 2800 Fax: +1 608 824 2996 Accuray Japan K.K. - Tokyo Shin Otemachi Building 7F 2-2-1 Otemachi, Chiyoda-ku Tokyo 100-0004 Japan Tel: +81.3.6265.1526 Fax: +81.3.3272.6166 Accuray Asia Ltd. - Hong Kong Suites 1702-1704, Tower 6 The Gateway, Harbour City 9 Canton Road, T.S.T. Hong Kong Tel: +852.2247.8688 Fax: +852.2175.5799 Accuray Chengdu #39 Huatai Road, Longtan Industrial Zone, Section 2 East, 3rd Ring Road, Chengdu, Sichuan 610051 China Accuray Europe Tour Atlantique 25e 1 Place de la Pyramide 92911 Paris La Défense Cedex France Tel: +33.1.5523.2021 Fax: +33.1.5523.2039 Tomotherapy Belgium BVBA Pegasuslaan 5 1831 Diegem Belgium Tel: +32 (0)2 400 4400 Fax: +32 (0)2 400 4401/02 2011 Accuray Incorporated. All Rights Reserved. Accuray, the stylized logo, CyberKnife, Synchrony, Xsight, Xchange, RoboCouch, TomoTherapy, Hi Art, and TomoHD are among the trademarks and/or registered trademarks of Accuray Incorporated in the United States and other countries. TomoTherapy is a wholly owned subsidiary of Accuray. 500846.B