SCE Energy Conservation Series. Computing The Benefits: Solutions for Creating Energy-Efficient Data Centers. Powerful Insights

Similar documents
Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Overcoming the Challenges of Server Virtualisation

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Rethinking Datacenter Cooling

Virtualization and consolidation

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

Green Data Centers A Guideline

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Green IT and Green DC

MSYS 4480 AC Systems Winter 2015

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Power and Cooling for Ultra-High Density Racks and Blade Servers

Liebert DCW CATALOGUE

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Reducing Data Center Cooling Costs through Airflow Containment

Data Center Energy and Cost Saving Evaluation

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Energy Efficiency Solutions for Your Data Center

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Impact of Air Containment Systems

Power & Cooling Considerations for Virtualized Environments

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Efficiency of Data Center cooling

84 kw, Tier 3, Direct Expansion, 937 ft 2

Running Your Data Center Under Ideal Temperature Conditions

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Thermal management. Thermal management

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

ENCLOSURE HEAT DISSIPATION

Reducing Energy Consumption with

Recapture Capacity for Existing. and Airflow Optimization

MEASURE MONITOR UNDERSTAND

Optimizing Cooling Performance Of a Data Center

Close Coupled Cooling for Datacentres

November/December 2011

Switch to Perfection

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Environmental & Efficiency Trends in Enterprise Computing. John Sheehy Systems Architect

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

DC Energy, Efficiency Challenges

Session 6: Data Center Energy Management Strategies

Ten Cooling Solutions to Support High- Density Server Deployment

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

The Energy. David L. Moss Dell Data Center Infrastructure

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

APC APPLICATION NOTE #146

Google s Green Data Centers: Network POP Case Study

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Next Generation Cooling

Server room guide helps energy managers reduce server consumption

10 TECHNIQUES FOR IMPROVING DATA CENTER POWER EFFICIENCY

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

18 th National Award for Excellence in Energy Management. July 27, 2017

POWER AND THERMAL MANAGEMENT SOLUTIONS

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

New Techniques for Energy-Efficient Data Center Cooling

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Rittal Cooling Solutions A. Tropp

Data centers control: challenges and opportunities

1.0 Executive Summary

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

A Green Approach. Thermal

EP s approach to Power & Energy efficiency in DCs & paradigms

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

CHAPTER 11 Data Centers and IT Equipment

Total Modular Data Centre Solutions

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

> Executive summary. Implementing Energy Efficient Data Centers. White Paper 114 Revision 1. Contents. by Neil Rasmussen

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

How to Increase Data Center Efficiency

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

APC by Schneider Electric Elite Data Centre Partner

Airflow Management s Role in Data Center Cooling Capacity

CRITICAL FACILITIES ROUNDTABLE HEAT REMOVAL IN DATA CENTERS ENGINEERED SOLUTIONS

APC APPLICATION NOTE #74

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Eaton Open Data Centre Solutions. Kari Koli

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Transcription:

SCE Energy Conservation Series Computing The Benefits: Solutions for Creating Energy-Efficient Data Centers Changes in equipment, facility layout and procedures can have a big impact on energy costs. Computers and data have become a virtual necessity in homes and certainly in a typical business setting. Increasingly, data is housed in data centers, which account for a significant amount of U.S. energy consumption. In fact, it is estimated that 3% of the nation s electricity goes to powering these centers. 1 Additionally, experts project data center electricity consumption to increase to approximately 140 billion kilowatt-hours (kwh) annually by 2020 the equivalent annual output of 50 power plants. 2 IT Energy Managers Can Raise Their Energy IQ While the macro trend may be hard to reverse, there are ways for businesses to decrease energy use. New technology, equipment upgrades, select equipment decommissioning, along with changes in facility layout and procedures can all have a positive impact on energy-efficiency. These measures include: Energy-optimized data center configuration Improvements like these can produce significant energy savings, help individual data centers reduce their energy bill, and help us reduce the load on the electric grid. We have compiled this handy guide to provide some tips to help IT energy managers like you succeed in improving energy efficiency. First Things First: What Makes Data Centers So Energy-Intensive? Data centers are prime targets for reducing corporate energy consumption simply because they are energy-intensive. What makes them so? For one, they typically house a high density of machinery, notably servers, spinning storage devices, high-speed microprocessors, and other equipment. Such equipment not only draws lots of power, but just as important for this discussion, it also generates tremendous heat. This heat usually necessitates an extensive air cooling system to maintain optimal operating temperatures inside the center to prevent data loss. Powerful Insights Decommissioning or consolidating IT equipment Installing solid state storage (SSD), ultrasonic humidifiers, or Variable Frequency Drives (VFD) Adopting passive and close-coupled cooling Server power management Airflow optimization Optimizing uninterruptible power supplies (UPS) In 2013, U.S. data centers consumed an estimated 91 billion kwh of electricity, equivalent to the annual output of 34 large 500-megawatt (MW) coal-fired power plants. 3 1 Energy 101: Energy Efficient Data Center. U.S. Dept. of Energy. 2 Delforge, Pierre. Critical Action Needed to Save Money and Cut Pollution. NRDC. February 06, 2015. 3

Anatomy of a Data Center Video Surveillance System Diesel Generator Fire Fighting System Cabinets Chiller Plant Air Conditioning System Raised Floor UPS with Battery Backup Network Operation Center Outdated operational practices can also make certain data centers energy-inefficient. These include: Solution: Server Power Management While rack servers tend to account for the largest portion of energy usage in a typical data center, the majority of servers usually run at or below 20% utilization. 5 Yet they can still draw full power the entire time. This presents a unique opportunity to save energy through what is called server power management practices. Variable-Speed Fans When purchasing new servers, it s a good idea to look for models that include variable as opposed to fixed-speed fans for the internal cooling component. These fans modulate RPMs according to the demand on the server, and can save significant amounts of energy, especially when multiplied across an entire array of servers. Imbalanced redundancy Over-cooling Room for Improvement Aversion to free-cooling Energy-Saving Options Abound The good news is that forward-thinking IT operations may have a number of options at their disposal for reducing data center energy usage, the most important of which this guide will explore. In many cases, IT energy managers will discover that these solutions provide many benefits beyond simple energy savings, potentially helping the organization: Enhance operational efficiency Improve bottom-line profitability Accomplish corporate green initiatives Effect of Data Center Improvements on IT Energy Productivity 4 The majority of data center servers usually run at or below 20% utilization, yet they can still draw full power the entire time. 5 Throttle-Down Drives So-called throttle-down drives are also excellent ways to better manage server power. These devices cut energy consumption by putting idle processors to sleep. Thus, when a server is running at its typical 20% utilization, it is not drawing full power. Since servers are engineered to handle tens of thousands of on-off cycles, this has minimal effect on data reliability. ENERGY STAR provides free phone and email consultations to help IT energy staff with planning computer power management or data center energy-efficiency projects! 6 4 www.microsoft.com/environment/it_energy/it_energy.aspx. Accessed May 22, 2015. 5 Best Practices Guide for Energy-Efficient Data Center Design. National Renewable Energy Laboratory. U.S. Department of Energy. March 2011. 6 energystar.gov/products/low_carbon_it_campaign/contact_energy_star_free_tech_support.

Software Power Cyclers Server power consumption can also be reduced by installing power cycler software, which works by directing individual devices on the rack to power down during periods of low demand. Solution: Data Center Infrastructure Management (DCIM) Software-based data center management tools are part of a growing trend of solutions that allows managers to take a holistic view of their operation, not just in terms of energy consumption, but overall systems and building management as well. Upsite Technologies offers a convenient CCF Calculator to help you begin your assessment. Proper Server /Row Orientation The orientation of server racks and rows also makes a difference in the amount of energy your data center consumes. Most commonly, equipment takes in cold air through the front of the unit and expels hot air out the back. If your servers are arranged with the fronts of racks and the fronts of servers facing one another, you will achieve a consistent airflow. Specifically, DCIM applications monitor, measure, manage, and control facility performance, equipment utilization, and energy consumption. Although these tools do not reduce energy usage in and of themselves, they do provide critical feedback and help to drive data center optimization, which can save energy by means of: Row 1 Row 2 64ºF/18Cº 73ºF/23Cº 82ºF/28Cº Front (intake) Back (exhaust) CRAC Poor Orientation Can Lead to Hot Spots 9 Front Front Row 3 91ºF/ 33ºC Row 4 Thermal management Airflow optimization Better server utilization Server consolidation DCIM applications monitor, measure, manage and control facility performance, equipment utilization, and energy consumption. Solution: Airflow Optimization The average data center has a rated cooling capacity that is more than three times what the IT load demands. As a result, there is an enormous potential for many data centers to save energy through airflow optimization. 7 But if several rows are set up in the same orientation, the second row of racks takes in hot exhaust air from the first row. The problem is magnified with each progressive row, as the air temperature becomes hotter, causing more energy usage from A/C to keep the data center cool. The solution? s should always be oriented so that the fronts of the servers face each other. This so called hot aisle/cold aisle approach can reduce energy losses, and may also extend the life of your servers. Hot Aisle/Cold Aisle Approach to Server Orientation 10 Return Air Plenum Physical Separation Cooling Capacity Factor (CCF) Assessment A simple Cooling Capacity Factor (CCF) 8 assessment can help quantify your current cooling distribution efficiency and uncover the actual cooling effectiveness of your data center. These assessments measure your cooling output relative to IT load, and help adjust your cooling infrastructure. Hot Aisle Raised Floor Cold Aisle 7 Upsite Technologies. upsite.com. 8 9 Bouley, Dennis, APC, et al. Fundamentals Of Data Center Power And Cooling Efficiency Zones. The Green Grid. 2009. 10 Best Practices Guide for Energy-Efficient Data Center Design. National Renewable Energy Laboratory. U.S. Department of Energy. March 2011.

How Cool Is This? A recent case study conducted by the U.S. Dept. of Energy showed that airflow optimization strategies increased cooling capacity by 21% and decreased fan energy by 8%. 12 Optimized Airflow Within Aisles Depending on the design, A/C units in data centers can be placed outside of racks along the perimeter, mounted overhead, under the raised floor, or installed among the rows of IT racks. As explained earlier, minimizing the mixing of hot and cold air increases airflow efficiency, which usually equates to energy savings. Other simple modifications allow airflows to be much more predictable, enabling a greater portion of the cool air to be utilized, and higher power densities achieved. These include: Blanking panels, which fill spaces around equipment Air dams to seal the tops, bottoms, and sides of equipment Brush grommets, which fill open spaces around floor cable cut-outs Cabinet chimneys to contain hot return air Correcting Raised Floor and Airflow In many older data centers, the space beneath the raised floor has been used to route cabling. However, this obstructs airflow, making the A/C unit work harder. It is more efficient energy-wise to place cabling overhead, or run it under the hot aisle if a hot aisle/cold aisle strategy is being used. Rearranging Out-Of- Equipment Equipment such as large tape libraries or mainframe computers can cause airflow inconsistencies within any data center, leading to wasted energy. To remedy this issue, all devices that can be mounted in four-post enclosed racks should be. Other such equipment should all be placed in the same area of the data center to avoid disturbing optimal rack airflow. Solution: Variable Frequency Drives (VFDs) and Electronically Commutated (EC) Motors Some experts believe the era of containment as an airflow optimization technique separating cool supply air and warm exhaust air is over, and that bigger gains can be achieved through the use of VFDs and EC fan motors. Research indicates, a decrease of merely 10% in fan speed may result in as much as a 27% reduction in energy use and serve to prolong the life of the equipment. 13 Fans and ducting play a big role in data center design. However, traditional fans operate at full speed even when the supported loads require less capacity. Matching fan output to the load with an EC motor or a VFD may result in energy savings equal Cooling can account for 44% Energy savings from using VFDs can of a data center s energy consumption. 11 range from 20% to as much as 80%. 15 11 Klaus, Jeff. New Categories for Data Center Best Practices. Data Center Journal. April 15, 2013. 12 Bell, Geoffrey C., P.E. Data Center Airflow Management Retrofit. 13 Hassen, Marcus. Ten Tips To Make A Legacy Data Center More Energy Efficient. FacilitiesNet.com. February 2009. 14 Bouley, Dennis, APC, et al. Fundamentals Of Data Center Power And Cooling Efficiency Zones. The Green Grid. 2009. 15 Variable-Frequency Drives Spin Up Energy Savings for Data Centers. 2015 ABB Inc.

A decrease of just 10% in fan speed may result in as much as a 27% reduction in energy use and prolong the life of the equipment. 13 An ENERGY STAR-qualified UPS can cut energy losses by 30-55%. 16 to 50% or more of certain other part load control strategies. 14 DCIM software plus thermal sensors utilize these devices even more effectively. Solution: Efficient Uninterruptible Power Supplies (UPSs) UPSs maintain data center performance and business continuity in the event of an electrical disruption or major disaster. Transformer-based legacy UPS systems are adept at providing the highest efficiency at full loading however, few data centers are actually able to achieve full load. Newer energy-smart units reach high efficiency at more common operating conditions. This can equate to less heat dissipation, lower cooling requirements, and reduced energy usage. Along with better efficiency, modern UPSs also offer a smaller footprint and improved flexibility while providing high levels of reliability. To help reduce data center energy costs through UPS usage, we recommend that you: Match UPS loads as closely as possible to your IT loads Utilize the Eco Mode on these devices Consider scalable UPSs to allow for a coordinated growth path of UPS capacity and IT load Potential Utility Savings from UPS 17 94% 92% 90% 88% 86% 84% 1.2% increase in Efficiency 10% increase in Load Factor 82% 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Solution: Close-Coupled Cooling Overall, power usage per-square-foot is increasing in data centers across the country. But instead of increasing airflow volume (and power usage) to compensate, IT energy managers have the opportunity to save energy by incorporating so-called close-coupled cooling devices. Close-coupled cooling dictates that the cooling unit be moved from the perimeter of the data center to a position that is in the row or above the racks. This improves energy-efficiency by capturing hot exhaust before it has a chance to mix with the surrounding air, or recirculate to the front of the rack. This arrangement also makes it easier to add capacity to the server room. 16 Purchasing More Energy-Efficient Servers, UPSs, and PDUs. Energy.gov. 17 Best Practices Guide for Energy-Efficient Data Center Design. National Renewable Energy Laboratory. U.S. Department of Energy. March 2011.

Illustrations of Room-, Row- and -based Cooling 18 Room-based Row-based -based There are basically three types of close-coupled cooling configurations: Room-Based Cooling With a room-based approach, cooling units are associated with the room and work in tandem to reduce the total heat load of the room. They can be located in or outside the data center, and are effective with or without a raised floor. Aisle and/or rack containment is recommended for such arrangements. Cost Per Watt Comparison of Three Main Close-Coupled Cooling Technologies 19 Cost Per Watt ($) 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 Room-based / Raised floor Room-based / Raised floor with HAC Row-based / Close coupled Row-based / Close coupled with HAC -based 3 kw 6 kw 12 kw 20 kw Average Per- Power Density Row-Based Cooling Row-based cooling saves energy by shortening the airflow path, which reduces the fan power required to move the cool air. Cooling units may be located in between racks, or mounted overhead. IT equipment notably servers and data storage devices account for at least 50% of the energy consumption in the average data center. 20 This approach allows cooling to be targeted to actual needs of specific rows. For example, you might be running a high-density blade server on one row and a lower-density communication enclosure on another. -Based Cooling With cooling units directly mounted to or within the IT racks, rack-based cooling is the most energy-efficient of all the configurations, and allows you to achieve the highest rack power densities. Compared with room- or row-based cooling, airflow paths are even shorter, and become a non-factor in installation variation or room constraints. Hybrid Cooling Systems Data centers that have a mix of high and low rack power densities can often enjoy the greatest energy savings by applying a combination of room-, row-, and rack-based cooling technologies. Solution: Decommission Or Consolidate Zombie IT Equipment IT equipment notably servers and data storage devices account for at least 50% of the energy consumption in the average data center. 21 Yet studies show that up to one-third of this equipment is unused but powered on, taking up space, and often utilizing network ports and other resources, all of which wastes precious energy. Studies show that up to one-third of the equipment supported in the average data center is unused. 22 18 Dunlap, Kevin, et al. Choosing Between Room, Row, and -based Cooling for Data Centers. Schneider Electric. 2012. 19 20 Report to Congress on Server and Data Center Energy Efficiency. U.S. EPA ENERGY STAR Program. August 2, 2007. 21 22 Patrizio, Andy. Research Finds One-Third Of Data Center Servers Are Idle. ITWorld.com. June 10, 2015.

Often, these IT zombies are only discovered through Mergers & Acquisitions activities, data center moves, or other large-scale events. Fortunately, tools like DCIM applications are available to help you detect, manage and, if necessary, rid yourself of these potential energy wasters. Potential Solution: Storage Information in data centers is typically stored on traditional, inexpensive spindle or spinning hard disc drives (HDD). Yet, technological advances in tape libraries and an Archive Cloud provide today s most costeffective and reliable archive storage solutions. In addition, auto deduplication reduces the amount of network traffic and energy consumed by storage devices in your data center. Potential Solution: Ultrasonic Humidifiers Tightly controlling the climate inside your data center is essential to maintaining facility performance. Humidity in particular is traditionally added to air streams to reduce the risk of electrostatic discharge (ESD). This despite the fact that modern IT equipment is much more resilient to what was once considered adverse environmental conditions. What s more, better equipment design and insulation standards have reduced the risk of ESD even in low-humidity environments. Many data centers still use electric resistance heaters to create steam for humidification. Yet, by atomizing water through vibration, ultrasonic humidifier technology uses much less electricity, and can be a smart addition to your energy efficiency program. Make Your Data Center Energy-Smart Modern data centers have become essential storehouses of information for doing business and powering our everyday lives. Nonetheless, such demands require large amounts of power, plus a significant investment in time and money to sustain properly. Additional Resources Best Practices Guide for Energy Efficient Data Center Design. National Renewable Energy Laboratory. U.S. Department of Energy. March 2011. Energy.gov Report to Congress on Server and Data Center Energy Efficiency. U.S. EPA ENERGY STAR Program. August 2, 2007. Interested In Learning More? Choose from the many topics in our Energy Conservation Series: LED Lights: A Bright New Way to Conserve e Energy Plug In To Greater r Energy Savings With Smart Plug Load Management Switch To a More Energy-Efficient Business With Smart Lighting Controls Manufacturing Motors & Compressors: Start Your Energy-Efficient Engines Cold Hard Facts About Refrigeration and Energy Conservation for Grocery and Convenience Stores Energy Efficiency Is In the Air: Optimizing Your HVAC Agricultural Pumping: Pumped and Primed to Save Energy On The Menu: Major Energy Savings With Restaurant Refrigeration Fortunately, smart improvements, energy upgrades, modifications in procedures and practices, plus configuration changes discussed here may help you reduce energy usage in your data center. The tips contained in this article are for information only, and this article is meant to be an aid to understanding various data center measures for your company to consider. The article is not a recommendation or endorsement of any specific measure, or a warranty that any particular measure is appropriate for your company. Please consult your Account Manager or an energy professional prior to implementing a particular tip or measure to see if it s right for you. Savings may vary. For more help in saving energy or to learn about energy-efficiency incentives, contact your SCE Account Manager or visit sce.com/datacenters. C-9804 NR-864-V1-0916