Locking Reconstruction and Mini Plate System. Contourable in three dimensions.

Similar documents
LOCKING RECONSTRUCTION AND MINI PLATE SYSTEM

Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF

MatrixNEURO. The next generation cranial plating system.

A modular system that may be customized for orthognathic procedures

Technique Guide. Cannulated Percutaneous Guiding System. For percutaneous placement of 3.5 mm pelvic and cortex screws in the pelvic area.

Ordering Information. Low Profile 3.5 mm Pelvic System. The comprehensive solution for pelvic fracture fixation.

MatrixMANDIBLE TM PLATING SYSTEM OVERVIEW BROCHURE. The next-generation mandible plating system

Low Profile 3.5 Pelvic System. The comprehensive solution for pelvic fracture fixation.

Overview. Foot and Ankle. Implants and instruments.

Cannulated Screw System. Surgical Technique

PELVIC REDUCTION INSTRUMENTS & IMPLANTS

Aesculap Spine Spectrum Brochure

patent pending TTA RAPID 2

Lorenz. Plating System Neuro. Anticipate. Innovate ṬM

Small Fragment Base Set. Acumed Variable Angle Screw Compatible. Acumed System Compatibility Indicator. Surgical Technique

FLEXBOX. Installation Guide

Easy Locking Mechanism All-in-One Set Optimized Titanium (64LMGR5-Ti)

Fibular Distal Plate. Angularly stable screws The distal fibular plate is fixed using Ø 3.5 mm and Ø 3.5/2.7 mm angularly stable screws.

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings

Advancing Modularity FIREBIRD SPINAL FIXATION SYSTEM PHOENIX MINIMALLY INVASIVE SPINAL FIXATION SYSTEM

Five-Axis Fiber Aligner Model 9091 and Accessories

G12/G12x USER S MANUAL

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

Hip Revision System. The system cases are appropriately organized to accommodate specific procedures as deemed necessary during surgery.

Unitek Temporary Anchorage Device System. Versatile. Fixed. Anchorage. for Treatment Efficiency

FUSION LOCK. TitaniumFusionLockPlateSystem- SmalFragmentInstrumentsandImplants. ... perfection guaranteed...

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

WINSTA. Full Line Catalog 2008/2009

TITANIUM IMPLANT. Systems Anton Hipp.

CHARLOTTE. MTP Fusion System SURGICAL TECHNIQUE

U. TrueLok System (TL-HEX)

H3C S12500 Routing Switch Series

JLTX Lever and Joystick Replacement Instructions

SUBCON 15 HD (High-density) D-Subminiature Connectors

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

HP 1300 Remanufacturing Instructions Oasis Imaging Products, Inc. Technical Support: ext 110

Prisma II Chassis 56-Port Upgrade Technical Bulletin

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Specification. Width - 190mm Length - 230mm Thickness - 8mm Assembled height - 78mm Weight - 805g Table material - AL5052 Screw material - SS304

Maintenance station. For DePuy Synthes Power Tools Electric Pen Drive and Air Pen Drive Systems. instructions for use

edrive RAM Battery Alternate Replacement Procedure

Installing 6 Indexer: PRS Standard Tools

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Spindles Screws. 9b Overview. FSB Stabil-spindle. FSB Stabil-half-spindle. Accessories Stabil-spindle. FSB Special spindle. Accessories.

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

PT 1,5/ 3-5,0-H. Extract from the online catalog. Order No.:

Installing a Power over Ethernet injector

IMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE

GCX Mounting Assembly Installation Guide. Pedestal Mount for Philips IntelliVue MP5/20/30/40/50/60/70, MX400/450/500/550/600/700/800

April Price List. Cochlear Implant Systems

Extra Large Full Motion TV Mount for Televisions

A-dec 586 Ceiling Monitor Mount

Basic Training Course for Robotic Console Surgeon Standard Da Vinci Surgical System Setup Tutorial

Installation Instructions

Aesculap Sterile Technology Aesculap Universal Storage System. Organisation and protection of surgical instruments

Installation Instructions. Cutter Kit (for EasyCoder PF4i and EasyCoder PF4i Compact Industrial)

Tracked surgical drill calibration

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box.

TIONS INSTRUC TION A RECONSTRUCTION NAIL OPER

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

NBS-2X NIMBUS STABILIZER QUICK-START GUIDE

Further Information can be found at

2 1.1 Safety using methods Definition of warning symbols Standard accessories Installation...

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

Chevy Tahoe Installation Instructions

SMKDS 1/ 4-3,81. Extract from the online catalog. Order No.:

Rack Mount Interconnect Center (RIC3)

LASERJET ENTERPRISE M604, M605, M606

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Installation Guide Roll Stand Kit for Philips Avalon FM20/30

MBE Mounts and Adapters

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

Gateway Profile 4 service guide

DMD Extender. Application Note 1 Sega Large Screen LCD Replacement. V0.1 October 2013 Copyright 2013 Dr Pinball

MKKDS 1/ 4-3,81. Extract from the online catalog. Order No.:

Catalog Numbers: CMB022, CMB022-AA, CMB022-UP, CMB033, CMB033-AA, CMB033-UP, CMB-CW, CMB-LK

MODULE & HANDPIECE HOLDER POWER SWITCH LED INDICATORS USB PORT (SERVICE) REMOTE INTERLOCK

Series 3700 Screw Terminal Assemblies Installation Instructions

120Ra-1 Pentium III Processor Installation Insert

Fiber Management Tray (FMT) User Manual

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Matrx Back Interface

Standard Releasing Spear. Manual B215

ipod Classic Headphone Jack & Hold Switch Replacement

Mac mini Mid 2011 IR Sensor Replacement

Thanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque)

Mac Mini Mid 2011 SSD Dual Drive Installation

BD Laser User Guide * IMPORTANT * PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AS IMPROPER USE MAY DAMAGE THE MACHINE AND VOID THE WARRANTY.

CINTENNA ANTENNA REPAIR GUIDE

Mini Wall-mount Building Terminal (WBM)

The Implant of Choice for Extracortical, Soft Tissue Fixation in Cruciate Reconstructions.

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

In-Sight 7000 Series Vision System. Optional Configurations

GbX Backplane and Daughtercard Tooling. *GbX is a Trademark of Teradyne Inc.

Fibre Enlosures and Splicing

Portable Staging User Guide

Amphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608)

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

«АВТОП» Latch RH1 Locks. Plate Control. Static Fmax newton Dynamic Fmax newton. Latch locks

Transcription:

Locking Reconstruction and Mini Plate System. Contourable in three dimensions. Technique Guide Veterinary

Table of Contents Introduction Locking Reconstruction and Mini Plate System 2 Surgical Technique Preparation 5 Contour Plate 6 Position Plate 6 Insert Screws 7 Product Information Implants 9 Instruments 13 Modules and Accessories 15 Also Available 16 Locking Reconstruction and Mini Plate System Technique Guide Synthes

Locking Reconstruction and Mini Plate System. Contourable in three dimensions. 2.0 mm Mini Plate and 2.4 mm Titanium Locking Reconstruction Plate System for the mandible and maxilla: Provides locked or nonlocked self-tapping options Low-profile plating system Titanium implants The Locking Design: Increases construct stability Decreases risk of screw back-out and subsequent loss of reduction Screws are self-tapping Special double-lead threads engage and lock into the threaded plate holes * Ti-6AI-7Nb 2 Synthes Locking Reconstruction and Mini Plate System Technique Guide

2.0 mm Locking Screws and Plates 2.0 mm Locking Screws PlusDrive recess* Improves retention with screwdriver blade Reduces stripping and cam-out Provides off-axis screw placement ability Color-coding assists in locking screw size identification: 2.0 mm locking screw is blue Emergency screw available in cases of stripped screws Conical double-lead locking threads 0.75 mm pitch PlusDrive Recess 2.0 mm Cortex 2.0 mm Locking 2.4 mm Emergency 13 18 Threaded plate holes accept both nonlocking and locking 2.0 mm PlusDrive screws. Nonlocking screws allow a maximum of 13 18 of angulation from central axis. 2.0 mm Plates One screw size (2.0 mm) fits all 2.0 mm locking plate options Four profiles accommodate a wide range of indications Design facilitates rapid three-dimensional contouring for improved anatomic fit Manufactured from commercially pure titanium for biocompatibility Black dot etched on plate identifies extra large plate 1.0 Mini 1.25 Intermediate 1.5 Large 2.0 Extra Large 4.8 5.0 6.5 6.5 ** Data on file at Synthes Locking Reconstruction and Mini Plate System Technique Guide Synthes 3

2.4 mm Locking Screws and Plates 2.4 mm and 3.0 mm Locking Screws Cruciform recess Color-coding assists in locking screw size identification: 2.4 mm locking screw is purple, the 3.0 mm locking screw is aqua Cruciform Recess 2.4 mm Locking 2.4 mm Cortex 3.0 mm Locking (can be used as an emergency screw) 2.4 mm Plates Choice of 2.4 mm and 3.0 mm locking screws or 2.4 mm cortex screws Closely spaced holes optimize fixation in minimal bone space Design facilitates rapid three-dimensional contouring for improved anatomic fit Profile: 2.5 mm thick and 8 mm width Commercially pure titanium for biocompatibility 4 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Preparation 1 Expose and reduce fracture After completing the preoperative plan, expose the fracture or osteotomy site. Reduce as required. 2 Select and prepare implants Instrument 391.95 Plate Cutting Forceps for 1.5 mm 2.7 mm plates* Select the appropriate plate depending on the indication. Orient the plate so the topside (indicated by laser etch) is facing out. Cut to length, if necessary.. * Also available Locking Reconstruction and Mini Plate System Technique Guide Synthes 5

Contour Plate 3 Contour the plate Instrument 329.142 Combination Bending Pliers Contour the plate to match the anatomy. Note: When using the combination bending pliers for twoplane bending, the in-plane bend must be performed first in accordance with the etching on the instrument. Out-of-plane bending (shown) should be performed second. Out-of-plane bending 4 Position the plate Instrument 398.66 Plate Holding Forceps* Place the plate over the fracture of osteotomy site. Use the plate holding forceps to secure the plate to the bone, if desired. * Also available 6 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Insert Screws 5 Drill the first hole Instruments for 2.0 mm plates 03.111.010 1.5 mm Threaded Drill Guide 310.16 1.5 mm Drill Bit 323.201 2.0 mm Universal Drill Guide Instruments for 2.4 mm plates 397.441 1.8 mm Threaded Drill Guide, for 2.4 mm locking screws 397.442 2.4 mm Threaded Drill Guide, for 3.0 mm locking screws 310.510 1.8 mm Drill Bit 310.530 2.4 mm Drill Bit Select the appropriate drill guide (universal or threaded) based on which screws are being used. When a locking screw is placed, a threaded drill guide must be used for guiding the drill bit in the proper direction. The universal drill guide is used to place cortex screws. Note: If both locking and cortex screws are used in the plate, the following precautions are necessary: 1. Because cortex screws pull the bone to the plate, contouring of the plate is required at the screw hole(s) in which cortex screws are placed. 2. If cortex screws are used in combination with locking screws, cortex screws must be inserted and fully tightened prior to inserting locking screw(s). When treating fractures of the maxilla and mandible, accurate plate contouring is preferred regardless of what screws are used, as it improves the stability of the fixation and ensures that the implants lay adjacent to the bone. Note: Photo shows drill guides 312.154 and 312.155; however, the set includes the instruments referenced on page 13. Locking Reconstruction and Mini Plate System Technique Guide Synthes 7

Insert Screws 6 Measure for screw length Instrument for 2.0 mm/2.4 mm plates 319.11 Depth Gauge Use depth gauge to measure screw length. 7 Insert screw Instrument for 2.0 mm plates 313.251 1.5 mm/2.0 mm PlusDrive Screwdriver, self-retaining Instrument for 2.4 mm plates 313.94.96 2.4 mm Cruciform screwdriver with holding sleeve Insert the proper length 2.0 mm, 2.4 mm or 3.0 mm locking or 2.0 mm or 2.4 mm cortex screw through the plate and tighten until secure. Technique tips for PlusDrive screws: To engage the PlusDrive recess screw on the screwdriver blade, align the blade over the PlusDrive recess and slowly rotate it until the blade drops into the recess. Firmly press the blade to fully seat it in the screw. To disengage the PlusDrive recess screw, gently rock the screwdriver blade side-to-side to release the blade from the screw head. 8 Drill and place the remaining screws. 8 Synthes Locking Reconstruction and Mini Plate System Technique Guide

2.0 mm Titanium Plates VPT4010.04 2.0 mm Titanium Mini Locking Plate (1.0 mm thick), 4 holes, narrow VPT4010.06 2.0 mm Titanium Mini Locking Plate (1.0 mm thick), 6 holes, narrow VPT4010.20 2.0 mm Titanium Mini Locking Plate (1.0 mm thick), 20 holes, adaption VPT4011.06 2.0 mm Titanium Intermediate Locking Plates (1.25 mm thick), 6 holes VPT4011.12 2.0 mm Titanium Intermediate Locking Plates (1.25 mm thick), 12 holes VPT4013.06 2.0 mm Titanium Large Locking Plates (1.5 mm thick), 3x3 holes VPT4014.06 2.0 mm Titanium Large Locking Plates (1.5 mm thick), 6 holes Locking Reconstruction and Mini Plate System Technique Guide Synthes 9

2.0 mm Titanium Plates VPT4014.12 2.0 mm Titanium Large Locking Plates (1.5 mm thick), 12 holes VPT4014.20 2.0 mm Titanium Large Locking Plates (1.5 mm thick), 20 holes VPT4015.12 2.0 mm Titanium Extra-Large Locking Plates (2.0 mm thick), 12 holes VPT4015.20 2.0 mm Titanium Extra-Large Locking Plates (2.0 mm thick), 20 holes 10 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Titanium Screws for 2.0 mm Locking Reconstruction Plates 2.0 mm Titanium Locking Screw Total Length (mm) VST202.005 5 VST202.006 6 VST202.008 8 VST202.010 10 VST202.012 12 2.0 mm Titanium Cortex Screw, self-tapping, PlusDrive Total Length (mm) VST201.006 6 VST201.008 8 2.0 mm Titanium Cortex Screw, Coarse Pitch, self-tapping, PlusDrive Total Length (mm) VST201.010 10 VST201.012 12 VST201.014 14 VST201.016 16 VST201.018 18 2.4 mm Titanium Emergency Screw, PlusDrive Total Length (mm) VST203.006 6 VST203.008 8 VST203.010 10 VST203.012 12 Locking Reconstruction and Mini Plate System Technique Guide Synthes 11

2.4 mm Titanium Implants 2.4 mm Locking Reconstruction Plates Total Length (mm) VPT4120.14 104 VPT4120.24 184 2.4 mm Titanium Cortex Screw, self-tapping, cruciform recess Total Length (mm) VST211.008 8 VST211.010 10 VST211.012 12 VST211.014 14 VST211.016 16 VST211.018 18 VST211.020 20 VST211.022 22 VST211.024 24 2.4 mm Titanium Locking Screw, self-tapping, cruciform recess Total Length (mm) VST212.008 8 VST212.010 10 VST212.012 12 VST212.014 14 VST212.016 16 VST212.018 18 VST212.020 20 VST212.022 22 3.0 mm Titanium Locking Screw, self-tapping, cruciform recess Total Length (mm) VST311.008 8 VST311.010 10 VST311.012 12 VST311.014 14 VST311.016 16 VST311.018 18 VST311.020 20 VST311.022 22 12 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Instruments Instruments for screw insertion for 2.0 mm plates: 310.16 1.5 mm Drill Bit, quick coupling, 110 mm 310.19 2.0 mm Drill Bit 311.005 Screwdriver Handle with hex coupling 03.111.010 1.5 mm LCP Solid Threaded Drill Guide, for 2.0 mm locking screws 313.252 1.5 mm/2.0 mm PlusDrive Screwdriver Blade, self-retaining, hex coupling, 96 mm 323.201 2.0 mm Universal Drill Guide Locking Reconstruction and Mini Plate System Technique Guide Synthes 13

Instruments Instruments for screw insertion for 2.4 mm plates: 310.510 1.8 mm Drill Bit, quick coupling, 100 mm 310.530 2.4 mm Drill Bit, quick coupling, 100 mm 323.202 2.4 mm Universal Drill Guide 397.441 1.8 mm threaded drill guide, short, for locking reconstruction plate (for 2.4 mm locking screws) 397.442 2.4 mm threaded drill guide, short, for locking reconstruction plate (for 3.0 mm locking screws) Instrument for both 2.0 mm and 2.4 mm plates: 319.11 Depth Gauge for Mini Screws Instruments for plate cutting and contouring: 391.95 Plate Cutting Forceps for 1.5 mm 2.7 mm plates 329.142 Combination Bending Pliers Bending Templates For 2.0 mm Titanium Mini Locking Plates: 329.528 20 holes, adaption 329.529 6 holes, narrow For 2.0 mm Titanium Intermediate Plates: 329.525 6 holes 329.527 12 holes For 2.0 mm Large and Extra Large Plates: 329.524 20 holes 329.526 3 x 3 holes For 2.4 mm Locking Reconstruction Plates: 329.40.96 37 holes, straight 14 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Modules and Accessories Modules and Accessories 60.116.006 Graphic Case, 2/3 length, 1 high 60.116.007 Auxiliary Tray, 2/3 length, ½ width 60.116.050 Screw Module Shell 60.116.057 2.0 mm Screw Block for screw module shell 60.116.053 Screw Module Auxiliary Bin, 2/3 length 690.704 2.4 mm / 3.0 mm Screw Block for screw module shell 690.705 Label Pack for Vet Screws 690.706 Screw Module Auxiliary Bin, 1/3 length 690.704 690.706 Screw Length Markers/Screw Type Markers Screw length markers and screw type markers are used to label the contents of screw modules. All markers are available in 5 packs. Screw Type Markers 60.116.507 Cortex 60.116.513 Locking 60.116.537 2.4 mm Locking 60.116.538 3.0 mm Locking 60.116.539 2.4 mm Cortex 60.116.538 60.116.305 Screw Length Markers 60.116.305 Screw Length Markers for 5 mm 24 mm 60.116.324 For detailed cleaning and sterilization instructions, please refer to: www.synthes.com/cleaning-sterilization In Canada, the cleaning and sterilization instructions will be provided with the Loaner shipments. Locking Reconstruction and Mini Plate System Technique Guide Synthes 15

Also Available Also Available 312.154 1.5 mm Threaded Drill Guide, long, for 2.0 mm Locking Plates 312.155 1.5 mm Drill Guide, for 2.0 mm Locking Plates 312.156 1.5 mm Threaded Drill Guide for 2.0 mm Locking Plates (small head) 313.251 1.5 mm/2.0 mm PlusDrive ScrewDriver, self-retaining 313.252 1.5 mm/2.0 mm PlusDrive ScrewDriver Blade, self-retaining, 96 mm 313.253 1.5 mm/2.0 mm PlusDrive ScrewDriver Blade, self-retaining, 76 mm 313.254 1.5 mm/2.0 mm ScrewDriver Blade, self-retaining, PlusDrive 319.006 Depth Gauge for 2.0 mm and 2.4 mm screws 397.440 1.5 mm Threaded Drill Guide, short, for 2.0 mm Locking Plates 398.66 Plate Holding Forceps 16 Synthes Locking Reconstruction and Mini Plate System Technique Guide

Synthes USA 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.synthesvet.com 2013 Synthes, Inc. or its affiliates. All rights reserved. PlusDrive, StarDrive and Synthes are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 1/13 J11696-A