Linear Positioning Stage Reference Manual

Similar documents
Precision Piezo Stage Reference Manual (Open and Closed Loop Versions)

PR-32. Piezo Rotation Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

VT-50. Linear Positioning Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

PPS-28. Precision Piezo Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

Precision Piezo Stage Reference Manual (Open and Closed Loop Versions)

Linear Actuator Reference Manual

PPS-60. Precision Positioner Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

MPS50SL Miniature Mechanical-Bearing Screw-Driven Linear Stage

MX80S Ballscrew and Leadscrew Driven Stages

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV

LHM-E Product User's Manual Firmware 5.00 and up. Last Update: September Visit for more recent updates.

1500V - Vacuum Rated

User Manual Version: Date:

SENC 150 REFERENCE MANUAL

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Precision Actuators. // West // East

MTE Series Encoders. Performance and Value Compact Linear Encoder. Specifications. Benefits

PXL33 with 25, 60 and 110 mm travel

Cutter Option Installation Instructions

ENC 125 T/E REFERENCE MANUAL. Acu-Rite Companies Inc.

PSW-002. Fiber Optic Polarization Switch. User Guide

PCL40. PCL40 Linear Stage. PCL40 with 400 mm travel

PLG160 Linear Stage PLG mm Travel PLG160 s. NEMA23 In-Line. Frameless Motor

Stepper Systems. Chapter Four. Features Machine Specifications And Bid Proposals. Catalog Numbers

LX80L Linear Motor Tables

M-653 M-655 Differential Micrometer Drive. M-631 M-632 M-633 Micrometer Drive. M-619 M-626 Precision Micrometer Drive. Stroke to 20 mm, Manual

PLG210 Linear Stage PLG210. XYT stack of PLG160 and PLG210 Frameless Motor Stages on PLR350. XY stack of PLG210x300mm with in-line motor mount

MPS75SL. Miniature Mechanical-Bearing Screw-Driven Linear Stage. Compact 75 mm width, with travel to 100 mm. Precision ground ball-screw drive

Motorised Linear Stages

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

PLG110 Linear Stage PLG mm Travel PLG110 s. Frameless Motor With Ballscrew Linear Motor

Ultra Low Noise Laser 1550nm

DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47

Installation Instructions

V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES

Linear Servo Motor Driven

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

TRC-190 User s Manual

PanelView Plus/VersaView CE Terminals and Display Modules

USER MANUAL. RC-54DL KNET Auxiliary Control Panel MODEL: P/N: Rev 2

V-522, V-524, V-528 PIMag Voice Coil Linear Stages

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

MPS-GR Series. Mechanical-Bearing, Worm-Driven Rotary Stage. Low profile and compact with aperture. Precision worm-gear drive

NIR Moisture Analyzer KB-30

TRC-190 User s Manual

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Can eliminate static charge over an extensive range

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

Stages for Semiconductor Applications

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

3-Card Slot, Includes P1/P2/P3/P4 compatibility for Analog I/O, Digital I/O, & Pulse/Frequency

About this Document 2 Symbols and Typographic Conventions... 2 Figures... 2 Downloading Manuals... 2

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Mini Photoelectric Sensor

Butterfly Laser Diode Mount

MINISCALE PLUS Product Overview

icp installation guide

ETT 312 Build-In Touch Terminal

Data Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.

Features. 400LXR Series Linear Motor Tables. 400LXR Series

LaserLyte-Flex Red & Green Alignment System

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

Includes P1/P2/P3/P4 compatibility for Analog I/O, Digital I/O, & Pulse/Frequency

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

D-510 PISeca Single-Electrode Capacitive Sensor Probe

CMSA-100 Manual. Cinema Media Server Automation

Screw. Nut Guide. Features

SLA Battery Capacity Analyzer

Before starting the system, please carefully read this manual and keep it safely for future reference.

LAC Product User's Manual Firmware 5.00 and up. Last Update: November Visit for more recent updates.

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Mercury Manual No. IM-M1000 Rev G

S66 Series Electronic Fan Speed Control

PMDX-170 Slotted Optical Sensor

DC425 NEMA 4X Analog Output Transducers

RMB Peripheral Units Installation Guide

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

EP/2 Installation Instructions

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Datasheet MX Axis Stepper Drive with Breakout Board & I/O s. Version

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 1.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Allen-Bradley Drives

APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE

Kramer Electronics, Ltd.

TPE 1464 Series Pressure Transducer

E4PA. Ultrasonic Displacement Sensor. Ordering Information

KOBOLD TDA Series Digital Temperature Transmitter

Performance and Value Optical Encoder System. Specifications. Benefits

Component identification

ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

RS-232 Industrial Media Converter

Keysight M8000 Series BER Test Solutions

Transcription:

PP-30 Series Linear Positioning Stage

PP-30 Piezo Positioner Stage Rev 3.00 MICRONIX USA, LLC 15375 Barranca Parkway, E-106 Irvine, CA 92618 Tel: 949-480-0538 Fax: 949-480-0538 Email: info@micronixusa.com http://micronixusa.com

CONTENTS 1. INTRODUCTION... 2 1.1 PRODUCT DESCRIPTION... 2 1.2 RECOMMENDED CONTROLLERS... 3 1.3 TECHNICAL DATA... 3 1.4 LOAD CHARACTERISTICS... 3 2. MODEL CONFIGURATIONS... 4 2.1 PP-30 ORDER NUMBERS... 4 3. PREPARING TO INSTALL THE PP-30... 5 3.1 INSTALLATION PREPARATION... 5 3.2 PACKAGE CONTENTS... 5 4. INSTALLING THE PP-30... 7 4.1 PP-30 INSTALLATION... 7 4.1.1 General Mounting... 7 4.1.2 Mounting to an Optical Table... 8 4.1.3 X-Y Mounting... 9 4.1.4 X-Z Mounting... 10 5. CONNECTING THE PP-30... 11 5.1 ATMOSPHERIC ENVIRONMENTS... 11 5.1.1 Open Loop Installation & Wiring Diagram... 11 5.1.2 Closed Loop Installation & Wiring Diagram... 11 5.2 VACUUM ENVIRONMENTS... 12 5.2.1 Handling and Preparation... 12 5.2.2 Open loop Installation & Wiring Diagram... 12 5.2.3 Closed Loop/Encoder Installation & Wiring Diagram... 13 5.3 USING THE ENCODER MODULE... 14 5.3.1 Encoder Module Overview... 14 5.3.2 Encoder Module Pinout... 14 5.3.3 Operating and Electrical Specifications... 15 5.3.4 Output Signals... 15 6. TECHNICAL SPECIFICATIONS... 16 6.1 ELECTRICAL CONNECTIONS... 16 6.1.1 MMCX Connector... 16 6.2 DIMENSIONS... 16 6.2.1 PP-30 8mm, 18mm, & 30mm Open Loop Versions... 16 6.2.2 PP-30 8mm Closed Loop/Encoder Version... 17 6.2.3 PP-30 18mm & 30mm Closed Loop/Encoder Versions... 17 7. SUPPLEMENTARY INFORMATION... 18 7.1 UNITS AND CONVENTIONS... 18 7.2 PERSONAL SAFETY... 18 7.3 MAINTENANCE... 18 7.4 ACCESSORIES... 18 1

1. Introduction 1.1 Product Description The PP-30 is designed for precise positioning of small loads. With its space saving construction, piezo motor, and optional linear encoder, the PP-30 delivers nanometer resolution in a compact package. Ball bearings ensure smooth motion over 8, 18 or 30mm travel lengths. Multiple PP-30 stages can be combined to stack in XY or XYZ configurations for either vacuum or non-vacuum environments Features: Travel ranges of 8, 18 and 30 mm Load capacity up to 1kg 2mm/sec maximum speed 5 nm encoder resolution Bearings and Bearing Shaft Carriage Motor Shaft Motor MMCX Connector Base PP-30 8, 18 & 30mm Open Loop (Shown in center position) PP-30 18 & 30mm Closed Loop (Shown in center position) Encoder Head Encoder Scale Encoder Scale Encoder Head PP-30 8mm Closed Loop (Shown in center position) 2

1.2 Recommended Controllers The following controllers are available from MICRONIX USA: MMD-100 MMD-1x1 PMC-100 MMC-100 MMC-110 1.3 Technical Data Motor PM-001 Speed Max. (mm/sec) 2 Resolution Typical (nm) 1.5 (Open Loop), 5 (Encoder Version) Bi-directional Repeatability (nm) ± 10 (Closed Loop) Uni-directional Repeatability (nm) ± 10 (Closed Loop) Accuracy (µm) ± 0.125 (Closed Loop) 1.4 Load Characteristics Load Characteristics Fx(N) Fy(N) Fz(N) Mx(Nm) My(Nm) Mz(Nm) PM-005 10 4 10 0.5 0.5 0.5 3

2. Model Configurations 2.1 PP-30 Order Numbers Order No. PP-30-1 0 PM-001 1 8 mm 1 18 mm 2 30 mm 3 Open Loop 0 Analog 2 Digital, 5 nm* 3 No Limit Switches 0 Non-vacuum 0 Vacuum prepared, 10-6 mbar 1 Vacuum prepared, 10-9 mbar 2 * Other resolutions available upon request. Contact MICRONIX USA for custom version and stacking configurations. 4

3. Preparing to Install the PP-30 3.1 Installation Preparation When mounting the stage it is important to consider the flatness of the mounting surface, as the stage will conform to the shape of that mounting surface. A surface that is not flat can adversely affect the performance and structural integrity of the stage. The stage is calibrated and guaranteed to be within specification at 20 C ±5 C. Be sure to use the stage under the following conditions: Mount to a clean and flat surface which is free of debris, burrs or dings An indoor atmosphere free of corrosive gasses, and condensation Temperature range of 0-40 C Relative humidity between 20-80% Locate away from water, heat, and electrical noise 3.2 Package Contents If product is damaged or there are missing components, contact MICRONIX USA immediately. Do not discard product packaging in case of return shipment. Package Should Contain: PP-30 Linear Stage Any other previously agreed upon components such as a controller and cable 5

6

4. Installing the PP-30 All mounting patterns require M2.5 screws for mounting and M1.5 x 5mm dowel pins for precision alignment. Additional brackets and screws may be needed for custom applications. While installing, be careful not to touch the motor shaft. 4.1 PP-30 Installation 4.1.1 General Mounting For general mounting configurations, mount the carriage to the mounting surface. Align carriage with clearance holes to access carriage mounting pattern. Requires: 2x M1.5 x 5mm Dowel Pins 2x M2.5 x 10mm Slotted Cheese Head Screws (PP-30 Open Loop & 8mm Closed Loop Versions) M2.5 x 14mm Slotted Cheese Head Screws (PP-30 18mm & 30mm Closed Loop Versions) NOTE: Screw head height may not exceed 2mm PP-30 Open Loop & 8mm Closed Loop Versions Clearance Holes Customer Supplied Base Plate or Mounting Surface PP-30 18mm & 30mm Closed Loop Versions Direction of Travel 7

4.1.2 Mounting to an Optical Table Mounting to an optical table requires the use of the Adapter Base Plate (P/N: 430191). Additional screws will be needed to mount the Adapter Base Plate to the optical table. Requires: 2x M2.5 x 10mm Slotted Cheese Head Screws (PP-30 Open Loop & 8mm Closed Loop Versions) M2.5 x 14mm Slotted Cheese Head Screws (PP-30 18mm & 30mm Closed Loop Versions) 2x M1.5 x 5mm Dowel Pins 1x Adapter Base Plate (P/N: 430191) 4x M6 or ¼-20 Socket Head Cap Screws for mounting to an optical table (Customer Supplied) NOTE: Screw head height may not exceed 2mm PP-30 Open Loop & 8mm Closed Loop Versions Direction of Travel Adapter Base Plate (P/N: 430191) PP-30 18mm & 30mm Closed Loop Versions NOTE: The Adapter Base Plate fits all optical tables with 1 inch or 25mm square hole patterns 8

4.1.3 X-Y Mounting For X-Y mounting, follow the instructions for mounting the X-axis stage, outlined in section 4.1.1 General Mounting, then proceed to mount the Y-axis stage, as shown below: Requires: 2x M2.5 x 10mm Slotted Cheese Head Screws (PP-30 Open Loop & 8mm Closed Loop Versions) M2.5 x 14mm Slotted Cheese Head Screws (PP-30 18mm & 30mm Closed Loop Versions) 2x M1.5 x 5mm Dowel Pins NOTE: Screw head height may not exceed 2mm PP-30 Open Loop & 8mm Closed Loop Versions Direction of Travel NOTE: Screw head height may not exceed 2mm PP-30 18mm & 30mm Closed Loop Versions Direction of Travel 9

4.1.4 X-Z Mounting For X-Z mounting, fasten the stages together first (as shown below), then proceed to mount the X-axis stage to the mounting surface, outlined in section 4.1.1 General Mounting. Requires: 2x M2.5 x 4mm Slotted Cheese Head Screws 4x M1.5 x 5mm Dowel Pins PP-30 Open Loop & 8mm Closed Loop Versions NOTE: Screw head height may not exceed 2mm Direction of Travel PP-30 18mm & 30mm Closed Loop Versions Direction of Travel 10

5. Connecting the PP-30 5.1 Atmospheric Environments The PP-30 is black anodized for atmospheric environments. This allows for a harder surface finish and greater durability over the life of the stage. 5.1.1 Open Loop Installation & Wiring Diagram Connecting the PP-30 in an open loop only requires that the MMCX coaxial motor cable be connected to a compatible controller. No other cables or components are needed. 5.1.2 Closed Loop Installation & Wiring Diagram Using the PP-30 stage with an encoder requires a closed loop compatible controller (PMC-100) that recognizes encoder feedback. Connect the stage as shown below using the supplied 15 to 9 pin cable to connect the Encoder Module to the Controller. See Section 5.2.3 if connecting to the PMA-100 Controller 11

5.2 Vacuum Environments 5.2.1 Handling and Preparation The vacuum version of the PP-30 is non-anodized and prepared for use in vacuum environments. Take the necessary precautions (such as wearing gloves, clean room clothing, etc.) when handling the stage as to avoid any contaminants. The connectors that ship with the stage are for testing use only and should be replaced with permanent connectors prior to installation. 5.2.2 Open loop Installation & Wiring Diagram Connecting the PP-30 in an open loop requires the use of a feed through connector at the vacuum chamber wall. Match wire colors when passing the PP- 30 motor cable through the feed through connector. Temporary test connectors are standard. Requires customer supplied feed through connector 12

5.2.3 Closed Loop/Encoder Installation & Wiring Diagram Closed loop installation of the PP-30 stage in vacuum environments requires an intermediate feed through connector at the vacuum chamber wall that can accommodate both the motor cable, and the encoder cable. See Section 5.1.2, if connecting to the PMC-100 Controller. Important: Match wire colors when connecting the Encoder Head (vacuum side) to the Encoder Module (atmospheric side). Also, connect the shield of the Encoder Head to the shield of the Encoder Module through the feed through connector. Temporary test connectors are standard. Requires customer supplied feed through connector 13

5.3 Using the Encoder Module When connected in a closed loop, the Encoder Module should display two green LED s indicating a power source and proper encoder alignment. A Red or Yellow LED indicates misalignment of the Encoder Head, if this occurs contact MICRONIX USA. Do not manually adjust the Encoder Head or scale. For more information refer to MicroE Systems Mercury Encoders. 5.3.1 Encoder Module Overview Proper Alignment LED (Green) 15 pin D-sub Connector Improved Alignment LED (Yellow) Improper Alignment LED (Red) Power/Calibration Indicator 5.3.2 Encoder Module Pinout Pin Description Pin Description 1 Reserved 9 B- 2 Transmit** 10 B+ 3 Receive** 11 Alarm** 4 A- 12 +5V 5 A+ 13 Ground 6 Reserved 14 Index + 7 Reserved 15 Index - 8 Reserved *Note: Proprietary pins reserved for manufacturer programming, not required to be connected to controller. 14

5.3.3 Operating and Electrical Specifications Power Supply 5VDC ±5% @ 330mA (30mA for sensor) Operating Temperature 0 to 70 C Humidity 10-90% RH non-condensing 5.3.4 Output Signals *Note: The index pulse may be aligned with A- or B- at some interpolation values. 15

6. Technical Specifications 6.1 Electrical Connections 6.1.1 MMCX Connector 6.2 Dimensions Component Center Contact Shield Voltage Description Drive Signal Return Signal < ± 48V DC MMCX Right Angle Connector 6.2.1 PP-30 8mm, 18mm, & 30mm Open Loop Versions 16

6.2.2 PP-30 8mm Closed Loop/Encoder Version 6.2.3 PP-30 18mm & 30mm Closed Loop/Encoder Versions 17

7. Supplementary Information 7.1 Units And Conventions All measurements in this document are in the metric system of units. 7.2 Personal Safety Metric Unit English Unit 1 millimeter 0.0394 inches 1 micron 0.0000394 inches 1 Newton 0.2248 lbs 1 Newton-meter 8.85 n-lbs The PP-30 linear stage is a delicate mechanical device and should be handled with care. Do not drop or mishandle the stage. Keep hands clear of all moving parts while the stage is in motion to avoid personal injury. Do not touch the motor and shaft, as this will contaminate the lubrication and jeopardize the longevity of the stage. Follow the Safe Operating Environment requirements and use proper cable management to ensure a clean and safe operating environment. Allow for easy access to the stage in case of servicing. 7.3 Maintenance The PP-30 series of linear stages utilizes a maintenance free design. Do not modify the stage or perform any maintenance unless specifically instructed to do so by MICRONIX USA personal. If the stage is not performing up to the original specifications, please contact MICRONIX USA. 7.4 Accessories 430191 Adapter Base Plate, Table, PP-30 Used for mounting to an optical table with 1 or 25mm square hole patterns 18