AUTOMATION. NETx MaRS 2.0

Similar documents
AUTOMATION. NETx Voyager 5.0

AUTOMATION. NETx BMS Server 2.0

NETx BMS Server. OPC Server with data base, web server and BACnet/IP server. Functions Data import Interfaces System requirements Order information

NETx KNX OPC Server. Standard OPC solution for KNX projects of different size. Functions Versions System requirements Order information

YZP : SAUTER Vision Center

t h e n e w d i m e n s i o n a b r i d g e b e t w e e n w o r l d s Upgrade from NETxKNX OPC Server 3.0 to NETxKNX OPC Server 3.

PRODUCT BULLETIN. M-Graphics. modifications. graphic development

Integrated Energy Management System

Intranet Internet VPN. FUSE 6A EXT FUSE 6A status LOYTEC status LIOB-100 L-IOB. 6A status LIOB-100 Automation Server. status LOYTEC L-INX

AUTOMATION. Building management systems for providing security in existing KNX projects: Organizational measures and device monitoring

CDR DICOM Quick Start Guide

ABT Site CTABT-SITE-LIC

UA-5200 IIoT Communication Server

AUTOMATION. NETxAutomation. building management software

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

Efficient and Reliable

BCPro System Product Bulletin

Recommended System Requirements for Microsoft Dynamics SL 2018

Energy Management Smart Panel

MaestroLink Basic. AirScout airflow meters into any network switch and allow MaestroLink to scan the network and self-populate the equipment.

PHS 1601 Point Heating Control. voestalpine SIGNALINGSainerholz GmbH

Mains Quality PQ-ANALYZER CLASS A

Software Environments for energy management and control. Energy efficiency technology

Petroleum Experts CONTENTS. What Operating Systems and Hardware are the Petex IPM, IFM & IVM applications supported? IPM Suite...

Product Catalog For intelligent building automation solutions

Installing and Setting Up the Snap-on EPC. Rev.1.10 (10 Oct 2013) PN EN

Supervisory Controllers

How to register your user account and ECL Comfort 310 controller to the ECL Portal

take control with EMP Multi Plus 8.0

CYLON ACTIVE ENERGY ENGINEERS IRELAND CONFERENCE 1 ST OCTOBER 2013 OVERVIEW 2013

* Make the most of your energy

All roads lead to IntesisBox

System Requirements for Microsoft Dynamics SL 2018

Petroleum Experts CONTENTS. What Operating Systems and Hardware are the Petex IPM, IFM & IVM applications supported? IPM Suite...

Autodesk Revit Structure 2012 System Requirements and Recommendations. Minimum: Entry-level configuration. Operating System Microsoft Windows 7 32-bit

Trend Micro Core Protection Module 10.6 SP1 System Requirements

Danfoss Enspire a web-based SCADA software application

Product Information Version 3.0. ZEISS ZEN 2 core Smart. Precise. Open. Imaging Software Simplified.

HP Operations Orchestration

DeltaV Executive Portal

System Requirements 2008 R2

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Questions and Answers

Mobile High-Speed Internet. Quick Start Guide. Motorola w100 4G USB Data Card Windows/Mac compatible

Online data sheet MEAC CEMS SOLUTIONS

CCH ProSystem fx Engagement. Installation Guide

JUNG Visu Pro Smart Assistant

AMA ServerSim-G Server-Simulator for IEC Data Sheet

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

CGVision Package I. Visualisation software CGVision. CGVision Package I application example

M-BUS AMR SOFTWARE LorusTask Ver OPERATION MANUAL

DECS 2.0. Danfoss Energy Control System. Data sheet. Description DECS 2.0

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

DECS 2.0 Danfoss Energy Control System

SepacoreControl Software data sheet

G4K Fixed Power Quality Analyzer BLACKBOX. Don t be left in the dark

Webinar Energy Analyzer QA/S 3.x.1


ADDENDUM TO: BENCHMARK TESTING RESULTS UNPARALLELED SCALABILITY OF ITRON ENTERPRISE EDITION ON SQL SERVER

Molecular Devices High Content Screening Computer Specifications

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

DomiOP ebis400 Series A new generation of Building HMI s. embedded building information system

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre

GE Intelligent Platforms

Practical Aspects of CTI WSN Testbed

ProSystem fx Engagement. Installation Guide

The correct license for your application

Pow-R-Command 1000 Lighting Optimization Software

Facility Management Station

Installation Guide DECS Contents

BA Systems. 6th biannual Danish District Heating Days in Serbia, April, April 20th 2017 Building Automation Systems DH Days Page 1

SiPass Software. Fire & Security Products. SiPass integrated

INSTALLATION GUIDE. RAPID TAG PC-Based Software Installation Guide. Version 5.0

Secure Your Way of Life. Now Compa ble With. HSVGW-G Series Home Security Voice Gateway Series. Take Smart Living Up a Notch

Minimum System Requirements

Communication without limitation...

Software for automatic prepayment FULL WEB. Dedicated solution for Alcatel-Lucent OmniPCX Enterprise

Desigo Insight Management station, V6.0 Getting started. CM110490en_ Building Technologies

The world of BAOS. Easy connectivity for KNX with Bus Access and Object Server. Overview and applications

Performance and Efficiency

(Business & Ultimate Edition only) Windows XP Professional x86. Windows Server 2003 x86. Windows Vista x86

PowerStudio is simple, powerful and user-friendly software. Provides complete monitoring of energy in industrial and commercial buildings.

Simple, fast data acquisition and transfer for big data analytics

Product Bulletin. SGConfig Configuration Tool v9.0. GE Grid Solutions. Release Notification of SGConfig 9.0. Before Installation

(Business & Ultimate Edition only) Windows XP Professional. Windows Server Windows Vista

Power Products. Protection and Control IED Manager PCM600 Product Guide

General Specifications

ControlIT Process controller

INSTALLATION GUIDE. RAPID TAG EVAC PC-Based Software Installation Guide. Version 5.0

UC-ANALYTICS BY AURENZ FACT SHEET. Make your Unified Communication graphically visible. aurenz GmbH All rights reserved.

Communication Gateway COM 610. Product Guide

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Milestone XProtect. Professional 7.0 Administrator s Getting Started Guide

Solutions for office buildings

CorpSystem Workpaper Manager Installation Guide

HP Operations Orchestration

Fronius DATCOM. The data communication system for PV system monitoring

TiLocalDisplayNew. Software Manual 07/12-01 PC

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Transcription:

AUTOMATION

The Metering and Reporting System is a modern, user-friendly software that is able to display, analyze, and process smart metering data which is stored within a database system. can be used as a central, company-wide data collection for smart metering data. This metering data for energy, water, air, gas, or steam is continuously collected together with other meta-information. Due to the measurement of consumption values of different domains, it is possible to decrease the operating costs sustainably. Furthermore, a comprehensive database is provided that can be used for further computer-aided processing within cost and billing information systems.

The Metering and Reporting System NETx MaRS 2.0 is a modern, user-friendly software that analyzes and displays metering data that is collected from smart metering devices. This data is stored in a central database where it is available for further analyzing and processing tasks. Due to the flexibility of NETx MaRS, it can be used as a central, company-wide data collection for smart metering data. The gathered information can be metering data of any arbitrary resource like energy, water, air, or gas that is collected continuously together with other meta-information originating from any smart meter. In addition to simply collecting metering data, NETx MaRS can also be used to further process the gathered information. Within NETx MaRS, it is possible to define a hierarchically organized cost center structure that reflects the existing structure within the company or building. Based on this structure, comprehensive consumption and cost calculations can be performed. These calculations can be done for a single meter, for a dedicated resource, for a cost center, or for any combination of them. The results can then be used to generate user-defined documents like diagrams, graphs, tables that contain billing information, or even user-defined reports that can be created using the built-in report generator. Furthermore, it is possible to export the results to third-party applications for further processing using open interfaces. These consumption and cost calculations that are performed by NETx MaRS are important inputs for analyzing the behavior of the energy consumers within a building. Therefore, NETx MaRS helps to reduce operating costs sustainably and encourages the economic and ecological use of resources.

MaRS Server The NETx MaRS server is used as central component where the measured values of the different smart meters are managed. These values can be retrieved from one or more OPC servers. For further processing, the received values are stored in an SQL database. MaRS Clients One or more NETx MaRS clients can access the meter values that are stored within the NETx MaRS server. A NETx MaRS Client is able to analyze and show the consumption values and calculated costs and to manage the NETx MaRS projects. Indicators In NETx MaRS so called indicators can be defined. Indicators are properties that influence the consumption of a resource (e.g. room temperature). Indicators are used as comparative values. Virtual meters In addition to physical meters so called virtual meters can be added. Virtual meters are not assigned to real devices. The metering values are specified using a value table. Actions In addition to the visualization of consumptions values and the resulting costs, time-triggered actions can be executed. Reports and charts can periodically be sent via e mail, printed out, or exported to other systems. Reports The presentation of the data is done via tables, charts, and/ or diagrams that can be saved as documents. Whenever metering data changes, the data within the document is updated according to the current meter values. M etering a nd R eporting S ystem - Optimized resource management system User management Arbitrary resources Data export Data acquisition and cost calculation Independent from technology NETx MaRS includes the possibility for user management. Multiple users with different access rights can be created. NETx MaRS is not limited to the measurement of dedicated resources. Any smart meter (e.g. electricity, water, heating, gas,...) can be integrated into the NETx MaRS environment. The collected consumption values as well as the calculated costs can be exported for further processing. A connection to third-party systems (e.g. billing information software) is possible. NETx MaRS is used to collect consumption values from any smart meter. Based on defined resources and their tariffs, the costs of the consumption values are calculated. Using the NETx BMS server, smart meters from different technologies (KNX, BACnet, Modbus,..) can be integrated. Additional systems can be included using dedicated OPC DA 2.0 servers.

Application NETx MaRS Application Domians Metering and Reporting System - Optimized resource management system Performing consumption and cost calculations based on a defined cost center structure. Interfaces to third-party applications for further processing of the calculated results. Generation of presentation documents of the performed calculations such as diagrams, graphs, tables, billing reports The main goal of a building automation system is to provide increased comfort while keeping an efficient use of all available resources in mind. Thus, building automation systems do not only reduce the overall operational costs for maintenance but also decrease energy consumption and mainly contribute to environmental protection. In order to be able to increase the energy efficiency of modern buildings, monitoring the energy consumption of the different energy consumers as well as analyzing their overall energy behaviour are key requirements. The most important input data for this analyzing purpose are the energy consumption values of these energy consumers that are measured by smart metering devices. This is where NETx MaRS comes into play. NETx MaRS is a software tool that is focused on fulfilling the needs for analyzing, monitoring, and further processing smart metering data. Visualization and monitoring of consumption values and costs of any arbitrary resource (e.g. electricity, water, heat, gas, oil, air,...). Storing the collected values into the central database. Plausibility check of measured data. Analysis of the consumption values and costs and comparison with indicators (influencing value).

Components NETx MaRS consists of two components 1 NETx MaRS Client(s) - Application for end user - Retrieves the measured consumption values from NETx MaRS Server - Performs different energy management tasks - Use of multiple NETx MaRS Clients possible - Analysis and visualization of data - Generation of documents - Management of NETx MaRS projects NETx MaRS System NETx MaRS Server NETx MaRS Client NETx MaRS Client Foreign systems 2 NETx MaRS Server NETx BMS Server NETx BMS Server NETx KNX OPC Server Third party OPC Server - Reading meter values using a connection to one or more OPC servers - Storing of the retrieved values within the central NETx MaRS database - Providing the data to one or more NETx MaRS Clients KNX Modbus BACnet... KNX Modbus BACnet... KNX

Server/Client NETx MaRS Clients NETx MaRS Server NETx MaRS Client NETx MaRS Client NETx MaRS Server A NETx MaRS Client is an application program that performs different energy management tasks (e.g. visualization of the consumption values, calculation of the costs for each cost center, comparison and analysis of consumption values and costs,...). A NETx MaRS Client acts as an application that is dedicated to management tasks, a NETx MaRS Client requests the metering data from the NETx MaRS server. Using the retrieved data, all calculations and actions are performed. In addition, it is possible to define a hierarchically organized cost center structure that reflects the existing structure of the company or building. the end user. In order to perform energy The NETx MaRS Server is central server application that is responsible for retrieving the metering data from the smart metering devices. In order to achieve this, it opens a connection to one or more OPC servers. These OPC servers have the aim to collect the metering data from the smart metering devices located within the building automation system. The OPC servers act as generic interfaces between the smart metering devices and the NETx MaRS Server. Therefore, as long as an OPC server that supports the appropriate communication protocols is available, any smart meter can be integrated within the NETx MaRS system. Thanks to this architecture, the NETx MaRS Server does not need to bother about the details of the used smart meters. The collected metering data is stored within the NETx MaRS Server database where it is provided to the NETx MaRS Clients for further processing. In order to be able to configure and maintain the NETx MaRS Server, the NETx MaRS Server Studio is provided. The NETx MaRS Server Studio is a graphical user interface that provides a management interface to the NETx MaRS Server. Using this interface, the following three managements tasks can be performed: First, it is possible to add the OPC Servers that shall be connected with the NETx MaRS Server. Using a built-in OPC browser, the available OPC servers can be searched and selected. Second, it is possible to browse the OPC items that are provided by the selected OPC servers. Using the list view, the user can select the OPC items that correspond to the datapoints of the smart meters which are of interest for the given NETx MaRS project. Finally, using the NETx MaRS Server Studio can also be used to set global configuration parameters that influence the behaviour of the NETx MaRS Server.

Project structure The project structure consists of the following elements: Resources The resource type is not limited - any arbitrary resource (e.g. electricity, gas, water, heat,...) can be managed. Tariffs Tariffs specify the cost rates of the different resources (i.e. price per unit, base rate). It is possible to define multiple cost rates (e.g. for each month). Project structure Devices In NETx MaRS, three different device types are distinguished: - Physical meter: A physical meter is assigned to a physical datapoint that is responsible for providing the consumption values. In addition to these measurements, already existing consumption values can be imported. - Virtual meter: These meters do not have a datapoint. Their consumption values are provided by imported tables only. - Indicator: An indicator is a measured variable, which influences the consumption of a resource. Indicators are used for comparison issues. Cost centers A cost center is an organizational unit where consumption values or costs can be assigned. In order to perform different energy management tasks, the project structure has to be defined. After having defined the different resources, tariffs, devices, and cost centers, the project structure can be specified. The cost centers can be arranged hierarchically and the different meters can be assigned to the cost centers. The assignment can also be done in terms of percentage. Based on the defined cost center structure and on the assigned smart meters, the consumption and cost calculations are performed within the NETx MaRS Clients. These calculations can be done for each device or each cost center. For cost centers, the hierarchical structure is considered - the values of the underlying cost centers are added accordingly.

The results of these calculations can be shown as so called NETx MaRS documents. Depending of the desired view, such a document can be a chart, a graph, or a table. For each document, it can be decided whether the consumption values or the calculated costs shall be presented. In addition, it is possible to specify the time scale that shall be used for presentation. To be able to compare different cost and consumption values, it is possible to include multiple smart meters or cost centers within a single document. Each document can be stored as template for later use. By selecting an already stored document, the corresponding configuration of the document is loaded and the actual consumption or cost values are shown. In addition, it is possible to define actions for each document (e.g. periodically sending documents via e mail). Reporting

Software Metering datapoints Product-ID MaRS 2.0 STARTER 5 S19.02.0.03.01 Order number MaRS 2.0 HOME MaRS 2.0 BASIC MaRS 2.0 PROFESSIONAL 25 100 250 S19.02.0.03.02 S19.02.0.03.03 S19.02.0.03.04 MaRS 2.0 ENTERPRISE individual S19.02.0.03.05 USB-Dongle Free USB-Port required H00.00.0.00.04 An additional server is required - NETx KNX OPC Server 3.5 or NETx BMS Server 2.0 All versions are available with Softlock (license code) and Hardlock (USB-Dongle). It is recommended to use Hardlock version, since no additional licensing is necessary if the hardware or the operating system is changed. System requirements Hardware: PC - Intel oder AMD - 1.6 GHz (Multicore recommended) RAM: 2048 MB Hard disk: 4 GB (8 GB recommended) Ethernet interface: 100 MBit/s Screen resolution: 1280 x 1024 Supported operating systems: Windows XP Professional - 32 bit / SP 3 Windows 7-32 bit 64 bit Windows Server 2008 R2-64 bit Windows 8-64 bit Windows Server 2012-64 bit AUTOMATION Copyright 2013 NETxAutomation Software GmbH. All rights reserved. Other company and product names mentioned herein are trademarks of their respective companies. Version 2013-10-EN

AUTOMATION NETx Automation Software GmbH Maria Theresia Straße 41 - TOP 10 4600 Wels Austria T +43 7242 252 900 F +43 7242 252 900-21 office@netxautomation.com Member of: KNX Association OPC Foundation BACnet Interest Group Europe www.netx automation.com