Q.Clear. Steve Ross, Ph.D.

Similar documents
Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

Simultaneous measurement of noise and spatial resolution in PET phantom images

A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms

Modeling and Incorporation of System Response Functions in 3D Whole Body PET

Introduc)on to PET Image Reconstruc)on. Tomographic Imaging. Projec)on Imaging. Types of imaging systems

Improvement of contrast using reconstruction of 3D Image by PET /CT combination system

Assessment of OSEM & FBP Reconstruction Techniques in Single Photon Emission Computed Tomography Using SPECT Phantom as Applied on Bone Scintigraphy

Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels

The Design and Implementation of COSEM, an Iterative Algorithm for Fully 3-D Listmode Data

8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial

A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT

Image reconstruction for PET/CT scanners: past achievements and future challenges

White Paper. EQ PET: Achieving NEMAreferenced. Technologies. Matthew Kelly, PhD, Siemens Healthcare

Semi-Quantitative Metrics in Positron Emission Tomography. Michael Adams. Department of Biomedical Engineering Duke University.

The Effects of PET Reconstruction Parameters on Radiotherapy Response Assessment. and an Investigation of SUV peak Sampling Parameters.

Introduction to Positron Emission Tomography

Projection Space Maximum A Posterior Method for Low Photon Counts PET Image Reconstruction

Unconstrained image reconstruction with resolution modelling does not have a unique solution

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3T MRI. Floris Jansen, GE Healthcare July, 2015

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

NIH Public Access Author Manuscript J Nucl Med. Author manuscript; available in PMC 2010 February 9.

STATISTICAL image reconstruction methods have shown

In the short span since the introduction of the first

UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication

THE methods of maximum likelihood (ML) and maximum

Time-of-Flight Technology

Monte-Carlo-Based Scatter Correction for Quantitative SPECT Reconstruction

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Ordered subsets algorithms for transmission tomography

PET Image Reconstruction using Anatomical Information through Mutual Information Based Priors

Continuation Format Page

Evaluation of Penalty Design in Penalized Maximum- likelihood Image Reconstruction for Lesion Detection

Resolution and Noise Properties of MAP Reconstruction for Fully 3-D PET

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

SINGLE-PHOTON emission computed tomography

MAXIMUM a posteriori (MAP) or penalized ML image

PET image reconstruction algorithms based on maximum

664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005

Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction

Medical Imaging BMEN Spring 2016

Validation of New Gibbs Priors for Bayesian Tomographic Reconstruction Using Numerical Studies and Physically Acquired Data 1

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

3-D Monte Carlo-based Scatter Compensation in Quantitative I-131 SPECT Reconstruction

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

High-resolution 3D Bayesian image reconstruction using the micropet small-animal scanner

QIBA PET Amyloid BC March 11, Agenda

An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction

Single and Multipinhole Collimator Design Evaluation Method for Small Animal SPECT

An overview of fast convergent ordered-subsets reconstruction methods for emission tomography based on the incremental EM algorithm

EMISSION tomography, which includes positron emission

Customizable and Advanced Software for Tomographic Reconstruction

Partial Volume Effect correction in PET using regularized iterative deconvolution with variance control based on local topology

Noise weighting with an exponent for transmission CT

Iterative SPECT reconstruction with 3D detector response

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Quantitative Statistical Methods for Image Quality Assessment

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Clinically Feasible Reconstruction of 3D Whole-Body PET/CT Data Using Blurred Anatomical Labels

PET Quantification using STIR

Super-resolution Reconstruction of Fetal Brain MRI

The Impact of Point Spread Function Modeling on Scan Duration in PET Imaging

Fully 4D List-Mode Reconstruction with Temporal Basis Function Estimation

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

STATISTICAL positron emission tomography (PET) image

SUV Analysis of F-18 FDG PET Imaging in the Vicinity of the Bladder. Colleen Marie Allen. Graduate Program in Medical Physics Duke University

If it matters to you, it matters to us

Scatter Correction for Positron Emission Mammography

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

RADIOMICS: potential role in the clinics and challenges

Reconstruction in CT and relation to other imaging modalities

Motion Correction in PET Image. Reconstruction

THE general task in emission computed tomography (CT)

MR IMAGE SEGMENTATION

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

An object-oriented library for 3D PET reconstruction using parallel computing

Quantitative imaging for clinical dosimetry

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Performance Evaluation of the Philips Gemini PET/CT System

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Globally Convergent Image Reconstruction for Emission Tomography Using Relaxed Ordered Subsets Algorithms

GE Healthcare. AppsLinq* remote courses catalogue

High Temporal-Resolution Dynamic PET Image Reconstruction Using A New Spatiotemporal Kernel Method

Concepts, Applications, and Requirements for Quantitative SPECT/CT. Conflict of Interest Disclosure

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM)

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

Non-Homogeneous Updates for the Iterative Coordinate Descent Algorithm

MEDICAL IMAGE ANALYSIS

Introduction to Emission Tomography

USING cone-beam geometry with pinhole collimation,

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Transcription:

Steve Ross, Ph.D. Accurate quantitation (SUV - Standardized Uptake Value) is becoming more important as clinicians seek to utilize PET imaging for more than just diagnosing and staging disease, but also for treatment monitoring. The significant challenge with delivering consistently accurate SUV measurements in PET imaging is that lesion size, volume and contrast recovery are highly impacted by today s reconstruction algorithm. technology is a step forward in providing quantitation accuracy while not sacrificing excellent image quality in PET imaging. This new approach considers all aspects of the imaging chain and the cumulative effect of all improvements, from small to large, to make PET/CT imaging an accurate tool for enabling both confident diagnosis and precise treatment response assessment.

INTRODUCTION There is renewed interest in the PET imaging community in obtaining quantitative information about lesion uptake values. Because of this, improvements in image reconstruction algorithms that offer the ability to obtain more accurate estimates of uptake in lesions are of significant interest. Many advancements have been made towards this end, including improvements in system corrections such as randoms and fully 3D scatters [1-2], advances in motion correction [3], modeling of the system point spread function [4], and the inclusion of more accurate projectors and the incorporation of all system corrections into a fully 3D PET image reconstruction model [5]. A core tenet of PET image reconstruction algorithms is the modeling of the underlying PET Poisson noise statistics. Iterative image reconstruction techniques that accurately model the inherent PET physics are generally preferred over standard analytic methods including filtered backprojection (FBP) because of significant increases in signal-to-noise (SNR). The most commonly used clinical PET reconstruction algorithm is the Ordered Subsets Expectation Maximization () algorithm. offers the advantage of accurately modeling the underlying PET physics and also generating the PET images in clinically relevant times via accelerated convergence through the use of subsets. One drawback to the algorithm is that it generally cannot be run to full convergence because the noise in the image grows with each iteration. To compensate for this, the algorithm is generally stopped after a predetermined number of iterations, typically two to four, resulting in an underconverged image. Because PET contrast recovery depends on convergence rates, an under-converged image may produce bias, directly impacting lesion quantitation. To address the effects of convergence and provide more accuracy in PET quantitation, the Regularized Reconstruction iterative algorithm () is being introduced, incorporating prior knowledge about the image quality into the reconstruction. This prior knowledge is incorporated as a term in the algorithm discouraging differences in neighboring image voxel values. By incorporating this factor into the reconstruction algorithm, the algorithm can be run to full convergence and provide more accurate quantitation levels and improved SNR over. acquired data. For Poisson data, the goal of maximizing that probability (expressed here as its logarithm) can be described mathematically by the objective function, (1) where y i represents the measured PET coincidence data, x is the image estimate, and P is the system geometry matrix. The ML-EM algorithm provides an update equation which, given an image that isn t at the maximum of this function, generates a new image with an increased likelihood. Repeating, or iterating, this algorithm to convergence, when the update equation does not substantially change the image, yields the ML image. accelerates the convergence of ML by performing updates based only on a portion of the data at once, which approximates the ML-EM solution in much less reconstruction time. Due to the low volume of information in a conventional clinical PET acquisition, reconstructions using ML-EM or suffer from high noise when run to its full convergence. To avoid this result, the algorithm is typically stopped after 2-4 iterations. This is an effective method to reduce noise in the PET images, but the noise reduction comes at a cost of reduced quantitative accuracy and the potential introduction of distortions in small objects. This effect is demonstrated with a simple simulation as shown in Figure 1. Two small active objects of the same size and activity level are simulated, with one of the small objects placed between the two large elliptical objects of uniform activity distribution. Reconstructed images are shown using with 2 iterations and 25 iterations. While the fully converged 25 iteration image shows much improved contrast and a significant reduction in spatial distortions, excessive noise is introduced. Partial Convergence (2 iterations) Full Convergence (25 iterations) AND CONVERGENCE The most widely used reconstruction algorithm in PET clinical imaging is, an accelerated variant of the ML-EM algorithm [6-8]. The goal of ML-EM is to find the most likely image given the data, defined as the image that maximizes the likelihood (or statistical probability) of producing the Figure 1. Phantom simulation demonstrating the effects of convergence. The image on the left is reconstructed with two iterations of ; on the right, 25 iterations. Note the spatial distortion and loss of counts in the indicated feature at 2 iterations.

A clinical example of this effect is shown in Figure 2. Excessive noise is introduced into the high iteration images. To avoid this, an under-converged image, like the two-iterations image shown, is typically used in clinical practice. Convergence Challenges 1 iteration 2 iterations 10 iterations 25 iterations Figure 2. Clinical data reconstructed with a range of iterations. Excessive noise is introduced as the image reaches convergence. Q.CLEAR is a Bayesian penalized likelihood (PL) reconstruction algorithm [9-10] which incorporates an additional term in the objective function of equation 1. This term increases as image noise increases, reducing the objective function, which has the effect of steering the optimization algorithm away from noisier images. This allows the algorithm to reach full convergence without the detrimental effects of excessive noise found with. The PL objective function is written as:, (2) where the first several terms are the same as in Equation 1, R(x) is a penalty to control noise and β controls the relative strength of the regularizing term relative to the data statistics. makes use of the Relative Difference Penalty (RDP) [11] which has the advantage of providing activity dependent noise control. The RDP is given by, (3) where w j and w k are relative weights for different components of the function and γ is a tunable parameter which controls edge preservation. uses the Block Sequential Regularized Expectation Maximization (BSREM) algorithm to solve equation 2 [12-13]. BSREM algorithm allows every single image voxel to achieve 100% convergence despite that did not seek for convergence and may achieve partial convergence, full convergence or over convergence in one single image. The regularization is also modulated to allow an optimal tradeoff between image quality and quantitation. The penalty is designed such that edges are preserved while background image noise is kept low, thus providing superior image quality [14]. Because is always run to convergence, iterations and subsets are no longer inputs provided to the user as is commonly done in. In addition, since the image noise is controlled inside the iterative reconstruction as part of regularization, post filters are not necessary; this is shown in the process flow map of Figure 3.

Conventional Iterative Reconstruction Reconstruction STOP before the noise gets too high Deadtime/ Normal Detector Geometry Modeling (LOR) Randoms s Scatter Attenuation Image filtering Partially converged image Scanner correction Object model Deadtime/ Normal Detector Geometry Modeling (LOR) Randoms s P.S.F Scatter ULD-CT Attenuation Reconstruction STOP At full convergence Regularization Fully converged image Scanner correction Object model Figure 3. Process flow maps for conventional iterative reconstruction and. is a fully convergent iterative reconstruction method. Unlike, controls noise as part of the regularization process inside iterative reconstruction. FULL CONVERGENCE WITH NO COMPROMISES PHANTOM ANALYSIS Anthropomorphic Phantoms To demonstrate that full convergence using Q.CLEAR doesn t compromise image quality, SNR has been measured on two anthropomorphic phantoms filled and scanned on the Discovery* PET/CT 710. The first phantom was an Anthropomorphic Torso Phantom TM (Data Spectrum Inc, Durham, NC) as shown in Figure 4. The phantom was modified by the manufacturer so that 10 mm diameter hollow spherical inserts could be placed in varying locations within the phantom. The phantom was filled with 18 F-FDG and the spheres were filled to a target of four times the background. The second phantom scanned was a modified Extended Oval Phantom TM (also from Data Spectrum) as shown in Figure 5. The phantom was modified to include two mounted bottles, and each was filled to a similar density as the lung background of the anthropomorphic phantom. In addition, another bottle mounted in the middle of the phantom was filled to twice the background activity in order to emulate a hot organ. The phantom also contained spherical inserts to mimic lesions. These spheres were filled to 4 times the background activity concentration. In the Extended Oval phantom, a 10 mm diameter sphere was placed into one lung insert. In the background, two spheres (10 mm, 13 mm) were located between the lungs and the hot organ (see Figure 4). A 40 million count PET/CT study was done on the Discovery PET/CT 710 scanner to simulate a single frame of a representative clinical exam. Data acquired from both phantoms was reconstructed with and. The images were filtered with a 4 mm transaxial Gaussian filter and a light axial filter [1:6:1] to control noise. The images were reconstructed with β=350 and no post filtering. All corrections were applied inside the iterative reconstruction loop as shown in Figure 3 for both and. The images reconstructed using, shown in Figure 4 and Figure 5, demonstrate superior contrast to the images, particularly in the lung region. This is attributed to the slow convergence of in the cold background. The SNR results demonstrate a significant improvement with over, with particular improvement shown in the lung region but a clear benefit throughout the entire image.

(a) (a) (b) (b) (c) SNR 16 14 12 25 (c) SNR 10 8 6 4 2 0 10 mm Lung 10 mm Bkg 13 mm Bkg 20 15 10 5 Figure 5 (a) Extended Oval Phantom TM (Data Spectrum, Durham, NC) modified to include 10 mm and 13 mm spherical inserts, a lung region and an adjacent hot organ. (b) Reconstructed images from a 40M count study acquired on a Discovery PET/CT 710. images reconstructed using 2 iterations/24 subsets and a post-filtering of a 4 mm FWHM Gaussian in-plane and a [1:6:1] weighted axial filter. images reconstructed with β=350 and no post filtering. (c) SNR measurements where SNR is defined as signal in a sphere ROI divided by the standard deviation of large uniform background VOI. 0 10 mm Lung 10 mm Bkg 10 mm Edge Figure 4. (a) Anthropmorphic Torso Phantom TM (Data Spectrum, Durham, NC) modified to include 10 mm spherical inserts. (b) Reconstructed images from a 40M count study acquired on a Discovery PET/CT 710. images reconstructed using 2 iterations/24 subsets and a post-filtering of a 4 mm FWHM Gaussian in-plane and a [1:6:1] weighted axial filter. images reconstructed with β=350 and no post filtering. (c) SNR measurements where SNR is defined as signal in a sphere ROI divided by the standard deviation of large uniform background VOI.

NEMA Image Quality Phantom A NEMA Image Quality IEC Phantom (Data Spectrum, Durham, NC) shown was filled with 18 F-FDG and scanned on the Discovery PET/CT 710. Images were reconstructed with and. As described previously, all corrections were applied inside the iterative loop for both algorithms. images with 2 and 25 iterations are shown along with a image in Figure 6. The 25 iteration image shows improved contrast over the 2 iteration image; however, there is also a significant increase in image noise. shows up to 2 times improvement in PET quantitation accuracy (SUVmean) and PET image quality (SNR) over on both the Discovery PET/CT 610 and Discovery PET/CT 710. (a) SUV mean: 6.4 g/ml (b) 2 iter 25 iter SUV mean: 10.9 g/ml Figure 6. (a) NEMA Image Quality Phantom (Data Spectrum, Durham, NC) images from a study acquired on a Discovery PET/CT 710. images are shown for 2 iterations and 25 iterations and a post-filtering of a 6.4 mm FWHM Gaussian in-plane and a [1:4:1] weighted axial filter Standard axial filter). images are shown with β=350. QUANTITATION AND VISUAL IMPROVEMENTS ON CLINICAL DATA PET/CT scans acquired on Discovery PET/CT 690 and Discovery PET/CT 710 systems were reconstructed with and. All corrections were applied inside the iterative reconstruction loop for both and. and reconstructed images are shown in Figures 7, 8 and 9. The images show a significant increase in SUVmean with. Figure 7 shows whole-body 18 F -FDG clinical images acquired on the Discovery PET/CT 690. The image was reconstructed using 2 iterations/24 subsets and a post-filter of a 4 mm FWHM Gaussian in-plane and a [1:6:1] weighted axial filter. The image was reconstructed with a β=350 and no post filtering. Figure 8 shows 68 Ga-DOTATOC clinical images acquired on a Discovery PET/CT 710, which also demonstrates a significant increase in SUV mean with. The image was reconstructed using 2 iterations/24 subsets and a post-filter of a 6.4 mm FWHM Gaussian in-plane and a [1:4:1] weighted axial filter. The image was reconstructed with a β=400. Figure 7. Clinical 18 F-FDG images acquired on a Discovery PET/CT 690. The image was reconstructed using 2 iterations/24 subsets and a post-filtering of a 4 mm FWHM Gaussian in-plane and a [1:6:1] weighted axial filter ( Light axial filter). The image was reconstructed with β=350. (a) SUV mean: 4.2 g/ml (b) SUV mean: 11.1 g/ml Figure 8. Clinical 68 Ga images acquired on a Discovery PET/CT 710. The image was reconstructed using 2 iterations/24 subsets and a post-filtering of a 6.4 mm FWHM Gaussian in-plane and a [1:4:1] weighted axial filter ( Standard axial filter). The image was reconstructed with β=400.

Figure 9 shows 18 F-FDG clinical images acquired on the Discovery PET/CT 600 which also demonstrates a significant increase in SUV mean with. The image was reconstructed using 2 iterations/32 subsets and a post-filter of a 6.4 mm FWHM Gaussian in-plane and a [1:4:1] weighted axial filter. The image was reconstructed with a β=200 and no post filtering. Figure 10 shows 18 F-FDG brain images from two exams acquired on a Discovery PET/CT 690 and reconstructed with and. The images were reconstructed with 3 iterations/32 subsets and a post-filter of 2.5 mm. The images were reconstructed with a β=150 and demonstrate excellent contrast and image quality in both brain exams. (a) Exam1 SUV mean: 1.38 g/ml (b) Exam2 SUV mean: 6.33 g/ml Figure 9. Whole-body 18 F-FDG clinical images acquired on the Discovery PET/CT 600. The image was reconstructed using 2 iterations/32 subsets and a post-filter of a 6.4 mm FWHM Gaussian in-plane and a [1:4:1] weighted axial filter. The image was reconstructed with a β=200 and no post filtering. Figure 10. Two clinical 18 F-FDG brain acquisitions from a Discovery PET/CT 690. The images were reconstructed using 3 iterations/32 subsets and a post-filtering of a 2.5 mm FWHM Gaussian in-plane. The images were reconstructed with β=150. SUMMARY Many recent advancements have been made towards improved quantitative accuracy in PET imaging. A current impediment towards superior quantitative imaging in PET was the necessary under-convergence required in to control image noise. provides a fully convergent PET image reconstruction technique, enabled by controlling image noise through regularized reconstruction. was designed to provide excellent image quality and consistent and accurate quantitation. Like any change in reconstruction processing, the effects of the algorithm should be considered when evaluating longitudinal studies. The results presented here demonstrate that provides an increase in both SNR and SUV recovery over. As such, is the foundation in the next generation of quantitative imaging.

REFERENCES [1] C. Stearns, D. McDaniel, S. Kohlmyer, P. Arul, B. Geiser and V. Shanmugam, Random coincidence estimation from single event rates on the Discovery ST PET/CT scanner, IEEE Nuclear Science Symposium Conference Record, 2003. [2] M. Iatrou, R. Manjeshwar, S. Ross, K. Thielemans, and C. Stearns, 3D implementation of scatter estimation in 3D PET, IEEE Nuclear Science Symposium Conference Record, 2006, pp 2142-2145. [3] S. D. Wollenweber, G. Gopalakrishnan, K. Thielemans, and R. M. Manjeshwar, Evaluation of the Accuracy and Robustness of a Motion Algorithm for PET Using a Novel Phantom Approach, 2012, IEEE Transactions on Nuclear Science, Vol. 59 (1), pp. 123 130. [4] A. Alessio, C. Stearns, S. Tong, S. Ross, S. Kohlmyer, A. Ganin, P. Kinahan, Application and evaluation of a measured spatially variant system model for PET image reconstruction, IEEE Transactions on Medical Imaging, 2010, Vol. 29 (3), pp 938-949. [5] R. Manjeshwar, S. Ross, M. Iatrou, T. Deller, and C. Stearns, Fully 3D PET iterative reconstruction using distance-driven projectors and native scanner geometry, IEEE Nuclear Science Symposium Conference Record, 2006, pp 2804-2807. [6] L.A. Shepp and Y. Vardi, Maximum likelihood estimation for emission tomography, IEEE Transactions on Medical Imaging, 1982, Vol 1, pp. 113-121, [7] K. Lange and R. Carson, EM reconstruction algorithms for emission and transmission tomography, Journal of Computer Assisted Tomogrphay, 1984, Vol. 8, pp., 306-316. [8] H.M. Hudson and R.S. Larkin, Accelerated image reconstruction using ordered subsets of projection data, IEEE Transactions on Medical Imaging, 1994, Vol 16, pp. 516-526. [9] C-T.Chen, V. E. Johnson, W. H. Wong, X. Hul, and C. E. Metz, Bayesian Image Reconstruction in Positron Emission Tomography, IEEE Transactions on Nuclear Science, 1990, Vol. 37 (2), pp. 636-641. [10] E.U. Mumcuoglu, R. Leahy, S.R.Cherry, Z. Zhou, Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images, IEEE Transactions on Medical. Imaging, 1994, Vol. 13 (4), pp. 687-701. [11] J. Nuyts, D. Beque, P. Dupont, L. Mortelmans, A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomography, IEEE Transactions on Nuclear Science, 2002, Vol. 49 (1), pp. 56 60. [12] A. R. De Pierro and M. E. B. Yamagishi, Fast EM-like methods for maximum a posteriori estimates in emission tomography, IEEE Transactions on Medical Imaging, 2001, Vol. 20, pp. 280 288. [13] S. Ahn and J.A. Fessler, Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms, IEEE Transactions on Medical Imaging, 2003, Vol. 22 (5), pp. 613 26. [14] E. Asma, S. Ahn, S. Ross, A. Chen, and R. Manjeshwar, Accurate and consistent lesion quantitation with clinically acceptable penalized likelihood images, IEEE Nuclear Science Symposium Conference Record, 2012.

About GE Healthcare GE Healthcare provides transformational medical technologies and services to meet the demand for increased access, enhanced quality and more affordable healthcare around the world. GE (NYSE: GE) works on things that matter - great people and technologies taking on tough challenges. From medical imaging, software & IT, patient monitoring and diagnostics to drug discovery, biopharmaceutical manufacturing technologies and performance improvement solutions, GE Healthcare helps medical professionals deliver great healthcare to their patients. GE Healthcare 3000 N Grandview Blvd Waukesha, WI 53188 USA www.gehealthcare.com 2014 General Electric Company-All rights reserved. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue any products described at any time without notice or obligation. Please contact your GE representative for the most current information. GE, GE Monogram and imagination at work are trademarks of General Electric Company. *Trademark of General Electric Company. All third-party trademarks are the property of their respective owners. GE Healthcare, a division of General Electric Company. DOC1474189, Rev 3