Power Factor Controller BR604

Similar documents
Film capacitors Capacitors for Power Factor Correction

Film capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film capacitors Power Factor Correction

Surge arrester. 2-electrode arrester B88069X2233**** G31-A500X

Surge arrester. 2-electrode arrester B88069X2613C103 A60-A250XF

Surge arrester. 2-electrode arrester B88069X2701**** A71-H15X

Film Capacitors Power Factor Correction

B88069X2373B152 V14-H14XPD PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

Surge arrester. 2-electrode arrester B88069X2910**** EM550X

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B88069X4330B152 V10-H30X PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B88069X3733B252 T21-A90X PPD AB PD / PPD AB PM

Surge arrester. 2-electrode arrester

PPD AB PD / PPD AB PM

B3918 B39242B3918U410 May 06,

PPD AB PD / PPD AB PM

B44066T3050E402 B44066T3850E

PPD AB PD / PPD AB PM

B725**D****A*** CDS*C**GTA. New important notes template from Mrs. Kopp have been added

Surge arrester. 2-electrode arrester B88069X1193T303 S20-A470X

Surge arrester. 2-electrode arrester B88069X6071T203 S30-A150X PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

Magnetics modules for LAN applications

PPD AB PD / PPD AB PM

Evaluation Kit CeraPlas HF

PPD AB PD / PPD AB PM

Surge arresters. 2-electrode arresters

PPD AB PD / PPD AB PM

Multilayer Piezo Actuators

Evaluation Kit PowerHap TM

Multilayer ceramic capacitors

Film Capacitors Power Factor Correction

SIOV metal oxide varistors

Piezo Haptic Actuator - PowerHap

SIOV metal oxide varistors

CTVS Ceramic transient voltage suppressors

SAW components. SAW RF filter Digital radio. February 18, 2016

Leaded Varistors. AdvanceD-MP series. Date: Version:

Leaded varistors. SuperioR-MP series. Date: Version:

Leaded varistors. AdvanceD-MP series. Date: Version:

Leaded Varistors B72214X2421K501 SIOV- SNF14K420E2S5 PPD VAR PD

Ceramic transient voltage suppressors

Power Factor Correction

PPD VAR PD. Chao Fang, Terry Tian, Mac Gao New issue

SIOV metal oxide varistors

SPECIFICATION FOR APPROVAL

PF Controllers BR6000 Series

Piezo Haptic Actuators - PowerHap

Multi-Measuring-Interface MMI 6000

SIOV metal oxide varistors

PFC-10 Power Factor Controller

CeraDiodes. Standard series. Series/Type: Date: August 2012

SIOV metal oxide varistors

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

Power Factor Correction

Digital Multifunction Meters. Digital Multifunction Meters

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

SIOV metal oxide varistors

CeraDiodes. High-speed series. Series/Type: Date: July 2014

Power Meter PowerMonitor 500

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

CeraDiodes. LED series. Series/Type: Date: August 2016

POWER FACTOR REGULATORS

Rapidus Power Factor Controller

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

POWER FACTOR REGULATOR

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

CeraDiodes. Standard series. Series/Type: Date: April 2016

Technical Specifications. Multi Function Meter

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

WE-EPLE USB 2.0 A Connector

SYCON 55xxSS Automatic Power Factor Controller

Documentation. Mains filter AX2090-NF50. Version: Date:

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Energy Management Solutions

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

SMVector Additional I/O Module Installation and Operation Manual

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Technical Specifications. Dual Source Energy Meter (EB / DG)

Model 7705 Control Module

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

REACTIVE ENERGY REGULATORS

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

Transcription:

Power Factor Controller BR604 Series/Type: BR604 Ordering code: Date: December 2006 Version: 2 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table and then change the colour to White. This ensures that the table disappears for the customer pdf. Identification/Classification 1: (header 1) Identification/Classification 2: (header 2) Ordering code: Series/Type: (optional): (if necessary) PF-Controller for power factor correction PF-Controller BR604 Department: FK PC PM PFC Date: December 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Characteristics Intelligent control Menu driven handling (plain language; German/English) Self-optimizing control capability Recall function of recorded values Four-quadrant operation (e.g. stand by generator) Features Display - Large and multifunctional LCD (2 x 16 characters) - Graphic and alphanumeric System parameters displayed - System voltage (VAC) - Reactive power (kvar) - Active power (kw) - Apparent power (kva) - Apparent current (A) - Real-time cos phi - Target cos phi - kvar value to target cos phi Recall recorded values - Maximum voltage, (V max ) - Maximum reactive power, Q (kvar) - Maximum active power, P (kw) - Maximum apparent power, S (kva) Technical Data Weight Case Ambient conditions - Over-voltage class - Pollution degree - Operating temperature - Storage temperature - Sensitivity to inference (industrial areas) - Spurious radiation (residential areas) - Safety guidelines - Mounting position - Humidity class 0.5 kg Panel-mounted instrument, 100 x 100 x 40 mm) (cut out 92 x 92 mm) III 2-10 C... +70 C -20 C... +75 C EN55082-2.1995 EN55011 10.1997 EN61010-1 :2001 Any 15% to 95% without dew - Page 2 of 5

Protection class - Front plate - Rear side IP54 according to IEC60529 / DIN 40050 IP20 according to IEC60529 / DIN 40050 Operation - Supply voltage - Target cos phi - Switching and discharge time range - Number of control series - Control modes 230 VAC, 50 and 60 Hz power lines 0.8 ind. 0.8 cap. 1 255 seconds 23 series preset Series switching (LIFO), circular switching (FIFO), self-optimized intelligent control mode Measurement - Measurement voltage range - Fundamental frequency - Measurement current (CT) - Minimum operating current - Maximum current - Zero voltage release = supply voltage: 230 VAC (L-N) 50 and 60 Hz x/1 and x/5 Ampere possible 40 ma 5.3 (sinusodial) < 15 ms Switching outputs Relay outputs - Number of relays - Switching voltage/power - Expected mechanical life - Expected electrical life Ordering Code 4 steps available max. 250 VAC, max. 1000 W > 30 x 10 6 switching operations > 5 x 10 6 switching operations (load = 200 VA, cosphi = 0.4) Page 3 of 5

Connection plan L1 (R) L2 (S) L3 (T) N PE supply /meas.- voltage Vs meas.current Im (5A/1A) k l 1. capacitorbranch T 6, 3A L N k l Vs Im K1 1 2 3 4 capacitorcontactors 1-4 U Cautions: Controller hunting: When putting the capacitor bank into operation, it is required to avoid needless switching cycles (means permanent switching on and off of steps without significant change of consumer load). This so called controller hunting would increase the number of switching operations of the connected contactors and capacitors and decrease the expected life cycle (wear out) and, in worst case, capacitor bursting and fire, etc. This can be avoided by a proper programming of the BR604 with the actual system parameters (current transformer prim. and sec., first kvar step, control series, switching time). U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering. Page 4 of 5

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous ). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. FK PC PM PFC December 2006 Page 5 of 5