R&S ScopeSuite Release Notes Software Version 3.6.0

Similar documents
R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version

R&S GNSS Test Automation Release Notes Software Version 1.3.2

R&S AVG Pattern Import Release Notes Firmware Version 02.25

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7

R&S ELEKTRA Release Notes Software Version V2.10

R&S RECAL + Release Notes Software Version 4.01

R&S CMW Bluetooth Release Notes Software Version V3.2.70

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40

R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2

R&S RTB2000 Oscilloscope Release Notes Firmware Version

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1

R&S VISA Release Notes Software Version 5.8.6

R&S Broadcast Drive Test Release Notes Software Version 03.13

R&S SMA100B Release Notes Firmware Version

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes

R&S SGT100A RF Source Base Unit Release Notes FW Version

How to Apply MS17-10 to prevent WannaCrypt Attacks

How to Apply MS17-10 to prevent WannaCrypt Attacks

R&S SMB100B Release Notes Firmware Version

R&S TSMA Release Notes Firmware Version

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting

R&S QuickStep Test Executive Software Flexibility and excellent performance

QPHY-MIPI-D-PHY. Instruction Manual

R&S TSMAx Release Notes Firmware Version

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

How to deal with the effects of CVE

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Firmware Version Build 170 SP1

Keysight N5392B/N5392C Ethernet Compliance Test Application. Methods of Implementation

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a

CRESCENT HEART SOFTWARE

Compliance test method and detailed spec for - USB2.0. Tektronix Korea YJ.PARK

BitLocker White Paper Windows 10

R&S Power Meter NRP Release Notes Firmware Version

TekExpress 10GBASE-T Automated Compliance Software Features & Benefits

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

Keysight Technologies N6467A BroadR-Reach Automotive Ethernet Electrical Compliance Application

TopSec Mobile Secure voice encryption for smartphones and laptops

Keysight N8814A 10GBASE-KR Ethernet Backplane Electrical Performance Validation and Conformance

PVA-PTS PHY Performance Test Suite

Keysight Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

QPHY-PCIE (Gen1 and Gen2) Operator s Manual

NBASE-T and IEEE802.3bz Ethernet Testing 7 MARCH 2016

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version

Release Notes. R&S FSC Spectrum Analyzer

R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40

.NET programming interface for R&S GTSL and R&S EGTSL

Automotive Ethernet BroadR-Reach

PCI Express 4.0. Electrical compliance test overview

Universal Serial Bus Implementers Forum Hub Hi-Speed Electrical Test Procedure For Yokogawa DL9240/DL9240L/DL6154

Agilent N5393C PCI Express Electrical Performance and Compliance Software Release Notes

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version

PCI Express 3.0 Characterization, Compliance, and Debug for Signal Integrity Engineers

Resolving Security Issues When Working with the R&S ESIB in Secure Areas

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes

LabVIEW driver history for the R&S HMC8012 Driver Documentation

Firmware Release V1.83 SP3

Enabling MIPI Physical Layer Test

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

USB2.0 - Device. Universal Serial Bus Measurement

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software

QPHY-10GBase-KR Operator s Manual

Agilent Technologies EZJIT and EZJIT Plus Jitter Analysis Software for Infiniium Series Oscilloscopes

Universal Serial Bus 2.0 Host Compliance Test Procedure

PCI Express Signal Quality Test Methodology

DisplayPort 1.4 Webinar

R&S Browser in the Box Release Notes

QPHY-USB3.1-TX-RX. Instruction Manual

Help Volume Agilent Technologies. All rights reserved. Instrument: Agilent Technologies 16550A Logic Analyzer

USB Compliance Test Software for Infiniium Oscilloscopes

SV3C DPRX MIPI D-PHY Analyzer. Data Sheet

Release Notes Revision: 01

R&S InstrumentView Spectrum Analyzer Software Manual

Today s Schedule. USB 2.0 Overview. USB 2.0 Compliance Testing. Demo of the Agilent Solution Q&A

Universal Serial Bus Implementers Forum Host High-speed Electrical Test Procedure for LeCroy

R&S CLIPSTER Mastering excellence.

Keysight N8841A CAUI-4 Electrical Performance Validation and Conformance Software

R&S MSD Modular System Device Flexible antenna switching and rotator control

Ethernet 10/100/1000BASE-T Application Software TDSET3 SR-ENET DPO4ENET Datasheet

PCI Express 1.0a and 1.1 Add-In Card Transmitter Testing

R&S RTO, R&S RTP R&S ScopeSuite Automation Manual

Ethernet 10/100/1000BASE-T Application Software

R&S DVMS DTV Monitoring System Release Notes Firmware Version

High-speed I/O test: The ATE paradigm must change

Help Volume Agilent Technologies. All rights reserved. Instrument: Agilent Technologies 16557D 140 MHz State/500 MHz Timing Logic Analyzer

R&S NGE100 Power Supply Series Reduced to the max

N1014A SFF-8431 (SFP+)

40 and 100 Gigabit Ethernet Consortium Clause 86 40GBASE-SR4 and 100GBASE-SR10 PMD Test Suite v0.1 Technical Document

Release Notes. Revision: 01. R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer. Firmware Release 2.40

Transcription:

R&S Release Notes Software Version 3.6.0 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com Internet: http://www.rohde-schwarz.com Subject to change Data without tolerance limits is not binding. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this document: R&S is abbreviated as R&S. 1TD Release Notes PAD-T-M: 3574.3288.02/02.00/CI/1/EN

Contents Contents 1... 3 1.1 Version 3.6.0... 3 1.2Version 3.4.0... 5 1.3 Version 3.2.1... 7 1.4 Version 3.2.0... 8 1.5 Version 3.0.4... 9 1.6Version 3.0.2...10 1.7 Version 2.4.6...11 1.8 Version 2.4.4...12 1.9 Version 2.4.2...13 1.10 Version 2.4.0...14 1.11 Version 2.2.0...16 1.12 Version 2.1.2...17 1.13 Version 2.1.1...17 1.14 Version 2.1.0...18 1.15Version 2.0.0...19 1.16 Version 1.3.2...20 1.17 Version 1.3.1...20 2 Modifications to the Documentation... 21 3 Software Update... 22 3.1 Update Information...22 3.1.1 Requirements...22 3.1.2 Uninstall old Versions...22 3.1.3 Install R&S...23 3.1.4 Log files...23 3.1.5 Accessing old s...23 3.1.6 Error Recovery...24 4 Customer Support... 25 Release Notes 1317.4549.02 2

1 Information on the Current Version and History 1.1 Version 3.6.0 1000BASE-T1: 97.5.3.3 Transmitter timing jitter master mode 97.5.3.3 Transmitter timing jitter slave mode 97.5.3.3 Transmitter timing MDI jitter 97.5.3.6 Transmitter clock frequency 97.5.3.2 Transmitter distortion 97.5.3.4 Transmitter Power Spectral Density (PSD) 97.5.3.4 Transmitter power level 97.5.3.5 Transmitter peak differential output 97.5.3.1 Maximum Output Droop 97.7.2.1 MDI return loss 97.7.2.2 MDI mode conversion loss PCIe 1.x: Signal Quality (4.3.3) Mean unit interval Data rate Template tests Min eye width Median to max jitter Differential output voltage Reference Clock (1.32) Differential input High Voltage Differential input Low Voltage Duty Cycle Average Clock Period Rising edge rate Falling edge rate Mean unit interval PCIe 2.0 Signal Quality (4.3.3) Data rate Template tests Min eye width Release Notes 1317.4549.02 3

Median to max jitter Differential output voltage Support for B6 Waveform generator Support for 6GHz RTO Tested Firmware This Version is tested against the RTO Firmware Version 3.50.3.1 MIPI D-PHY Fixing chart plotting problems for group 3 and 4. TenBaseT MAU template trigger improved Link Test Pulse and TP_IDL work on a 600MHz scope 100BASE-T1 Saved waveform for debugging are saved in the session that are in the hidden folder ProgramData. Jitter master/slave mode filtered with TX_TCLK will not work on RTO 10x2 without a memory extension. HTML report has multiple headers and footers. Accessing s/sessions from versions before 3.0.0 (see 3.1.5) Sometimes test execution may result in an error when downloading screenshot image from the instrument. Please refer to section 3.1.6 on how to recovery from this error. Release Notes 1317.4549.02 4

1.2 Version 3.4.0 EEE 1000BASE-T EEE: Quiet Time (78.2) Refresh Time (Master) (78.2) Refresh Time (Slave) (78.2) Wake State Levels (40.6.1.2.7) Transmitter Timing Jitter With TX_TCLK (Master) (40.6.1.2.5) Transmitter Timing Jitter With TX_TCLK (Slave) (40.6.1.2.5) Transmitter Timing Jitter Without TX_TCLK (Master) (40.6.1.2.5) Transmitter Timing Jitter Without TX_TCLK (Slave) (40.6.1.2.5) 100BASE-TX EEE (24.2.3.4 and 78.2): Sleep Time LPI Quiet Time LPI Refresh Time LPI Transmitter Timing JItter Transmit Wake Time 10BASE-Te All test cases like 10BASE-T. 100BASE-T1/BroadR-Reach Renamed to 100BASE-T1 compliance test. Removed support for BroadR-Reach before version 3.2. Allow user to select channel for testing. Support Single Ended input like SMA cables for measurements. Return loss calibration with RT-ZF2 is optional. Support of IEEE 802.3bw limits and corresponding IOL test procedures. Added new test case: Peak differential output Allow user to export waveforms for offline analysis and debugging purposes. Transmitter distortion: Disallow user to test with TX_TCLX if B4 option (OCXO) option is not installed. Optimal auto scaling for all test cases. 2.5/5GBASE-T Support HD mode for jitter master and slave test. Release Notes 1317.4549.02 5

10GBASE-T Support HD mode for jitter master and slave test. 100BASE-TX Amplitude Domain Tests: Overshoot calculation is corrected. MIPI D-PHY Enhanced group 2 trigger for ULPS exit. Disallow the use of differential probe (except modular probe) for droop test. Disallow user to select R&S or Allion test fixture if -IF test fixture is selected Support for module probes. Tested Firmware This Version is tested against the RTO Firmware Version 3.40.1.2 BroadR-Reach Older sessions cannot be continued. Please create a new session for 100BASE-T1 Saved waveform for debugging are saved in the session that are in the hidden folder ProgramData. Jitter master/slave mode filtered with TX_TCLK will not work on RTO 10x2 without a memory extension. HTML report has multiple headers and footers. Accessing s/sessions from versions before 3.0.0 (see 3.1.5) Release Notes 1317.4549.02 6

1.3 Version 3.2.1 Demo D-PHY emmc emmc HS400 Demo report. Support long and continuous data burst. Allow user to adjust CLK trigger level. Support HS200 CLK for power save mode. BroadR-Reach Transmitter jitter is using right resolution. Undesired labels seen when running template tests are removed. Tested Firmware This Version is tested against the RTO Firmware Version 3.30.1.1. Jitter master/slave mode filtered with TX_TCLK will not work on RTO 10x2 without a memory extension. HTML report has multiple headers and footers. Accessing s/sessions from versions before 3.0.0 (see 3.1.5) Release Notes 1317.4549.02 7

1.4 Version 3.2.0 BroadR-Reach Support of common mode conversion loss test case. Support of common mode conversion loss adaptor verification. Support of common mode emission test case. 2.5/5GBASE-T Demo emmc Maximum Output Droop Non-linear Distortion Jitter Master Mode and Clock Frequency Jitter Slave Mode Power Spectral Density and Power Level MDI Return Loss 2.5G only Non-linear Distortion with Disturber Supporting Demo Sessions for emmc/hs400, 100BASE-T, BroadR-Reach. Support of transparent gates for better visibility of measurements. Support of Allion test fixture for embedded host. Support of Windows 8 and 10. Folder to save reports can be chosen and accessed more easily. BroadR-Reach Transmitter distortion test with TX_TCLK is only allowed if B4 OCXO option is installed. Return Loss. IF VNA is not connected Exception is handled properly. Fixed high speed signal quality test which intermittently fails with "Indeterminable" even though a valid signal is provided. Fixed chirp timing test which fails on some test bed computers Release Notes 1317.4549.02 8

Tested Firmware This Version is tested against the RTO Firmware Version 3.30.1.1. HTML report has multiple headers and footers. R&S Accessing s/sessions from versions before 3.0.0 (see 3.1.5) 1.5 Version 3.0.4 Support of new Version of RT-ZF2. D-PHY Support continuous data for group 3. Status of test is displayed correctly. Transmitter distortion will not fail when AverageCount is set to > 20. Scope Suite Proper error handling when no Visa is present. ET.dll is loaded correctly on RTO1XXX machines. Device packet parameter: Loosen trigger criteria Tested Firmware This Version is tested against the RTO1000 Firmware Version 3.0.1.1 and the RTO2000 Firmware Version 3.20.1.0. HTML report has multiple headers and footers. Release Notes 1317.4549.02 9

R&S R&S works only with Windows 7. Windows 8/10 is not supported Accessing s/sessions from versions before 3.0.0 (see 3.1.5) 1.6 Version 3.0.2 BroadR-Reach If HD mode is available enhanced accuracy is used. Demo Support for jitter slave and transmitter distortion test case without TX_TCLK. Demo test cases are available. emmc HS200 Bus signal level tests HS200 Interface timing tests HS400 Bus signal level tests HS400 Interface timing tests 100BASE-TX: If HD Mode is available enhanced accuracy is used. New Workflow and UI Matlab runtime is not needed anymore. D-PHY Transmitter distortion: Fixed erroneous pop-up of no signal when signal is there. Release Notes 1317.4549.02 10

Group5: Fixed skew calculation Tested Firmware This Version is tested against the RTO1000 Firmware Version 3.0.1.1 and the RTO2000 Firmware Version 3.20.1.0. HTML report has multiple headers and footers. works only with Windows 7. Windows 8/10 is not supported Accessing s/sessions from versions before 3.0.0 (see 3.1.5) 1.7 Version 2.4.6 BroadR-Reach Distortion test doesn't need MCR anymore. D-PHY Support for three probes setup. New test for 1000BASE-T Jitter Slavemode without TX_TCLK New jitter charts and Jitter histograms for 1000BASE-T Jitter Slavemode without TX_TCLK and for Jitter Master without TX_TCLK in the. Return loss tests now have a step for user to verify waveform on RTO before feeding waveform to VNA. Support for Tabor WX2182C. Support for current probe RT-ZC20B and RT-ZC10B. Support for restoring original settings upon exit of application if needed. Full Speed and Low Speed Signal Quality tests will now show split screen for two channels. Release Notes 1317.4549.02 11

Guided step numbers corrected when multiple pairs being tested. The report will now show the port under test for down stream full speed test. Scrambled measurements in Packet Parameters & Test_J/K/SE0_NAK test report fixed. Packet Parameters & Suspend/Resume/Reset timing tests improved. Guided steps improved for back voltage tests. Measurment limits for Test_J/K/SE0_NAK test improved. Full Speed and Low Speed Signal Quality tests improved to use full vertical scale of the scope. Fixed Device and Host J/K/SE0_NAK tests exiting prematurely when probes are not connected. Tested Firmware This Version is tested against the RTO Firmware Version 2.60.2.8 works only with Windows 7. Windows 8 is not supported HTML report has multiple headers and footers. 1.8 Version 2.4.4 BroadR-Reach Support Specification 3.2.. Support of ZNC and ZND. Release Notes 1317.4549.02 12

Cascaded hubs are supported. BroadR-Reach Corrected guided steps. Transmitter clock frequency calculation method changed. Disturber Signal corrected to the right level. D-PHY Some HS entry and exit limits corrected. Optimized scale for several waveform aquisitions. Microsoft Word supports links in Table of Contents Hub Ports over 10 are sorted numerically in the report. 10GBASE-T Transmitter clock frequency calculation method changed. Jitter measurements calculation method changed. works only with Windows 7. Windows 8 is not supported HTML report has multiple headers and footers. 1.9 Version 2.4.2 D-PHY Save set doesn't cause problem anymore for Group 3,4,5 Option is recognized properly 1000BASE-T PeakVoltage: Averaging is working correct 10BASE-T MAU template: External MAU template test uses right template Release Notes 1317.4549.02 13

1.10 Version 2.4.0 D-PHY Supported D-PHY test cases Group 1 (7 tests): Data Lane LP-TX Signaling Requirements 1.1.1 Data Lane LP-TX Thevenin Output High Level Voltage (VOH) 1.1.2 Data Lane LP-TX Thevenin Output Low Level Voltage (VOL) 1.1.3 Data Lane LP-TX 15%-85% Rise Time (TRLP) 1.1.4 Data Lane LP-TX 85%-15% Fall Time (TFLP) 1.1.5 Data Lane LP-TX Slew Rate vs. CLOAD (δv/δtsr) 1.1.6 Data Lane LP-TX Pulse Width of Exclusive-OR Clock (TLP-PULSE-TX) 1.1.7 Data Lane LP-TX Period of Exclusive-OR Clock (TLP-PER-TX) Group 2 (5 tests): Clock Lane LP-TX Signaling Requirements 1.2.1 Clock Lane LP-TX Thevenin Output High Level Voltage (VOH) 1.2.2 Clock Lane LP-TX Thevenin Output Low Level Voltage (VOL) 1.2.3 Clock Lane LP-TX 15%-85% Rise Time (TRLP) 1.2.4 Clock Lane LP-TX 85%-15% Fall Time (TFLP) 1.2.5 Clock Lane LP-TX Slew Rate vs. CLOAD (δv/δtsr) Group 3 (16 tests): Data Lane HS-TX Signaling Requirements 1.3.1 Data Lane HS Entry: Data Lane TLPX Value 1.3.2 Data Lane HS Entry: Data Lane THS-PREPARE Value 1.3.3 Data Lane HS Entry: Data Lane THS-PREPARE + THS-ZERO Value 1.3.4 Data Lane HS-TX Differential Voltages VOD(0) and VOD(1) 1.3.5 Data Lane HS-TX Differential Voltage Mismatch ΔVOD 1.3.6 Data Lane HS-TX Single-Ended Output Voltages VOHHS(DP) and VOHHS(DN) 1.3.7 Data Lane HS-TX Static Common-Mode Voltages VCMTX(1) and VCMTX(0) 1.3.8 Data Lane HS-TX Static Common-Mode Voltage Mismatch ΔVCMTX(1,0) 1.3.9 Data Lane HS-TX Dynamic Common-Level Variations Between 50-450 MHz ΔVCMTX(LF) 1.3.10 Data Lane HS-TX Dynamic Common-Level Variations Above 450 MHz ΔVCMTX(HF) 1.3.11 Data Lane HS-TX 20%-80% Rise Time tr 1.3.12 Data Lane HS-TX 80%-20% Fall Time tf 1.3.13 Data Lane HS Exit: THS-TRAIL Value 1.3.14 Data Lane HS Exit: 30%-85% Post-EoT Rise Time TREOT 1.3.15 Data Lane HS Exit: TEOT Value 1.3.16 Data Lane HS Exit: THS-EXIT Value Group 4 (18 tests): Clock Lane HS-TX Signaling Requirements 1.4.1 Clock Lane HS Entry: TLPX Value 1.4.2 Clock Lane HS Entry: TCLK-PREPARE Value 1.4.3 Clock Lane HS Entry: TCLK-PREPARE + TCLK-ZERO Value 1.4.4 Clock Lane HS-TX Differential Voltages VOD(0) and VOD(1) 1.4.5 Clock Lane HS-TX Differential Voltage Mismatch ΔVOD 1.4.6 Clock Lane HS-TX Single-Ended Output Voltages VOHHS(DP) and VOHHS(DN) 1.4.7 Clock Lane HS-TX Static Common-Mode Voltages VCMTX(1) and VCMTX(0) 1.4.8 Clock Lane HS-TX Static Common-Mode Voltage Mismatch ΔVCMTX(1,0) Release Notes 1317.4549.02 14

1.4.9 Clock Lane HS-TX Dynamic Common-Level Variations Between 50-450 MHz ΔVCMTX(LF) 1.4.10 Clock Lane HS-TX Dynamic Common-Level Variations Above 450 MHz ΔVCMTX(HF) 1.4.11 Clock Lane HS-TX 20%-80% Rise Time tr 1.4.12 Clock Lane HS-TX 80%-20% Fall Time tf 1.4.13 Clock Lane HS Exit: TCLK-TRAIL Value 1.4.14 Clock Lane HS Exit: 30%-85% Post-EoT Rise Time TREOT 1.4.15 Clock Lane HS Exit: TEOT Value 1.4.16 Clock Lane HS Exit: THS-EXIT Value 1.4.17 Clock Lane HS Clock Instantaneous: UIINST Value 1.4.18 Clock Lane HS Clock Delta UI: (ΔUI) Value Group 5 (4 tests): HS-TX Clock-to-Data Lane Timing Requirements 1.5.1 HS Entry: TCLK-PRE Value 1.5.2 HS Exit: TCLK-POST Value 1.5.3 HS Clock Rising Edge Alignment to First Payload Bit 1.5.4 Data-to-Clock Skew (TSKEW[TX]) BroadR-Reach Calibration.xml is added in the installer Power Spectra Density: Does work with RTO firmware 2.30 Transmitter Distortion: Peak distortion has to be > 15 mv for all values Return Loss: corrected typo error in step-by-step guide More meaningful error message when no signal is detected 1000BASE-T Differential Output Voltage: Does work with RTO firmware 2.30 1000BASE-T Transmitter Distortion: No Out of system memory error when 4 pairs are selected 100BASE-TX Rise and fall times: calculated correctly 1000BASE-T Common Mode Output Voltage: Gives warning if no probe is connected 10BASE-T Output Timing Jitter: Does work well with RTO firmware 2.30 2.0 Host: Support embedded host and test fixture from Testronic Labs 2.0 Hub Upstream Repeater: Does work with RTO firmware 2.30 legacy Back Voltage: Test fails when back voltage is less than -0.4 V works only with Windows 7. Windows 8 is not supported Microsoft Word report does not have hyperlinks. Release Notes 1317.4549.02 15

HTML report has multiple headers and footers. 1.11 Version 2.2.0 BroadR-Reach Supported BroadR-Reach test cases Transmitter Output Droop Transmitter Distortion Transmitter Timing Jitter (Master and Slave) Transmitter Power Spectral Density Transmitter Clock Frequency MDI Return Loss Link from details section to test summary in the report VXI11 connection for Hameg signal generator Modified Functionality Changed Microsoft style message box to customized style back voltage step-by-step guide is corrected for full speed device 2.0 receiver sensitivity triggers for devices with low sensitivity level Session with a '/' in its name do work now works only with Windows 7. Windows 8 is not supported Microsoft Word report does not have hyperlinks. HTML report has multiple headers and footers. Release Notes 1317.4549.02 16

1.12 Version 2.1.2 Modified Functionality Tabor Generator is supported correctly again Fix for "Date" field in the report is blank for. Fix for "Test fixture" field in the report is blank in. shows differences between Device, Host and Hub in the Header Device Type and Power Type are shown both in the report Microsoft word report does not contain pass/fail icon defect is fixed works only with Windows 7. Windows 8 is not supported Microsoft word report does not have hyperlinks. HTML report has multiple headers and footers. 1.13 Version 2.1.1 2.0 hub downstream jitter test supports -IF test fixture Modified Functionality 1000 and 10G Jitter tests were improved. Reorder 10GBASE-T test sequence to minimize changing of test mode waveform Fixed incorrect step numbering in 1000BASE-T Transmitter Distortion test Works with the latest RTO Firmware 2.15.2 Release Notes 1317.4549.02 17

Latest report or session appear on top of the list in report and session management Limit Editor: Negative values for frequencies are not allowed. works only with Windows 7. Windows 8 is not supported Microsoft word report does not have pass/fail icon and hyperlinks. HTML report has multiple headers and footers. 1.14 Version 2.1.0 Support of 10GBASE-T Compliance test cases. 10-1000BASE-T configuration is more clearly arranged. Support of low speed signal quality test for device. Support of high speed chirp timing test for hub downstream. User configurable left logo in the header. ing Support of Microsoft word report. RTF report no longer supported. Provide hyperlinks from test summary to test detail sections. Failed measurements are highlighted in red. Modified Functionality Upstream Test_J/K/SEO_NAK: Remove unnecessary steps to "Return to Main" on HSETT tool from the step-by-step guide. Instruct user, in the step-by-step guide, to power cycle the DUT in order to reset it, if it is a self-powered device Release Notes 1317.4549.02 18

1000BASE-T peak output voltage with disturber, transmitter distortion and jitter tests yield more accurate results. Faster start up time. Prevent instrument information go out of sync when IP address is changed. works only with Windows 7. Windows 8 is not supported Microsoft word report does not have pass/fail icon and hyperlinks. HTML report has multiple headers and footers. 1.15 Version 2.0.0 Support of 10 BaseT Compliance test cases Support of 100 BaseTX Compliance test cases Support of 1000 BaseT Compliance test cases Support -IF High Speed Signal Quality test fixture. Support digital multimeter measurements for Test_J/K/SEO_NAK and drop tests. Modified Functionality Support ET20 version 1.18.00 Use the widest pulse when determining EOP field in 2.0 packet. Improve Receiver Sensitivity accuracy. Fix measurement bug in Hub Repeater test. Installation can be run without admin rights 1000BaseT 1000BaseT Transmitter distortion test results sometimes show higher values than expected with certain DUTs. Peak output voltage test with disturbing signal may sometimes yield different test results if the test waveform voltages at measured points vary significantly. Release Notes 1317.4549.02 19

1.16 Version 1.3.2 Modified Functionality Added merge modules to support DLL build with VS2010 Using TestCenter 2.1.10.12 1.17 Version 1.3.1 Modified Functionality Support RTO Firmware 1.47 and 1.50 correct Start Menu Folder Release Notes 1317.4549.02 20

Modifications to the Documentation 2 Modifications to the Documentation The current documentation is up-to-date. Version 1.0 26.06.2013 Version 2.0 30.09.2013 Version 3.0 17.01.2014 Version 4.0 02.05.2014 Version 5.0 05.06.2014 Version 6.0 20.10.2014 Version 7.0 15.12.2014 Version 8.0 19.03.2015 Version 9.0 03.08.2015 Version 10.0 11.02.2016 Version 11.0 25.04.2016 Version 12.0 17.06.2016 Version 13.0 26.07.2016 Version 14.0 20.12.2016 Version 15.0 03.03.2016 Release Notes 1317.4549.02 21

Software Update 3 Software Update 3.1 Update Information 3.1.1 Requirements R&S can be installed on Windows 7,8 and 10 systems. You need a VISA installed. The system is tested against R&S VISA 5.5.4 and we recommend to use this or a higher version. www.rohde-schwarz.com/rsvisa 3.1.2 Uninstall old Versions It is recommended to remove older versions manually before starting installation. Open Control Panel Choose Uninstall a program Select R&S and uninstall it. Release Notes 1317.4549.02 22

Software Update 3.1.3 Install R&S The installation of the R&S, is started by executing the file "RSSetup.exe". An Install wizard like this starts and follow the instructions. You can install R&S on Windows 7 When you install R&S on a RTO please reboot the RTO after installation. 3.1.4 Log files In case you encounter problems it is helpful to supply us log files and send along a waveform from the scope when the problem occurred. The log files can be found here: <My Documents folder>\rohde-schwarz\rs\3.0\logs 3.1.5 Accessing old s With R&S 3.0.0 and above you cannot access the reports from earlier versions out of the anymore. When you created reports we recommend to access reports directly in the session folder: C:\ProgramData\Rohde-Schwarz\RS\Session Release Notes 1317.4549.02 23

Software Update C:\ProgramData is a hidden folder, so you might have to adjust your visibility settings for the file explorer. In the case you have not created the s you have to uninstall the 3.0.0 and above and reinstall the old version and create the report from the Management. When going back to 3.0.0 and above remove the old Version and please make sure to remove the following folder before installation 3.0.0 and above. C:\ProgramData\Rohde-Schwarz\Server You cannot run two versions in parallel. 3.1.6 Error Recovery Check RTO firmware version. Confirm that it is the same as the version stated in "Tested Firmware". Check for loose connection. Make sure the probe is connected to the test point firmly. Check if the DUT is in the correct test mode. If problem persists, soft reboot the instrument. Select "File" (bottom left) followed by "Exit". Launch the application from the desktop ("RTx" for oscilloscope and "Vector Network Analyzer" for VNA). If problem still persists, hard reboot the instrument by switching it off and on again. Release Notes 1317.4549.02 24

Customer Support 4 Customer Support Technical support where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment. Up-to-date information and upgrades To keep your instrument up-to-date and to be informed about new application notes related to your instrument, please send an e-mail to the Customer Support Center stating your instrument and your wish. We will take care that you will get the right information. Europe, Africa, Middle East Phone +49 89 4129 12345 customersupport@rohde-schwarz.com North America Phone 1-888-TEST-RSA (1-888-837-8772) customer.support@rsa.rohde-schwarz.com Latin America Phone +1-410-910-7988 customersupport.la@rohde-schwarz.com Asia/Pacific Phone +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China Phone +86-800-810-8828 / +86-400-650-5896 customersupport.china@rohde-schwarz.com Release Notes 1317.4549.02 25