E-STOP relay, safety gate monitor

Similar documents
E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safe monitoring relays

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

Two-hand control unit

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Faults on the system Proximity switch connection technology:

PNOZ s1. Safety relays. Operating Manual EN-07

Safe monitoring relays

Contact expander modules

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s9. Safety relays. Operating Manual EN-08

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

Electronic monitoring relays PMDsrange

20 inputs for connecting, for example:

Datasheet - SRB 402EM-24V

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

Datasheet - SRB 301LC/B-24V

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

PNOZ X1. } Safety relays. Operating Manual EN-08

Datasheet SRB301ST 24V (V.2)

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Datasheet - SLB 200-C04-1R

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

PHOENIX CONTACT Features

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MINI-PS AC/10-15DC/8

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

QUINT-PS/ 1AC/24DC/20/CO

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

PSR UC/ESAM4/3X1/1X2/B

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Installation / Control Technique

MSR178DP. Description. Features. Specifications

Non-Contact Safety System CES-AZ

Power supply module, bus connection module

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Temperature Switches

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

VAL-CP-1S-175. Extract from the online catalog. Order No.:

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

PHOENIX CONTACT - 07/2006

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

VAL-CP-3S-350. Extract from the online catalog. Order No.:

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Transcription:

Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection options for: E-STOP pushbutton Safety gate limit switch Reset button LED indicator for: Switch status channel 1/2 Supply voltage Semiconductor output Semiconductor output signals: Switch status channel 1/2 Plug-in connection terminals (either cage clamp terminal or screw terminal) See order reference for unit types Unit description The safety relay meets the requirements of EN 60204-1 and IEC 60204-1 and may be used in applications with E-STOP pushbuttons Safety gates Safety features The relay conforms to the following safety criteria: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. The unit has an electronic fuse. Block diagram A1 A2 1 2 23 33 = = Reset/ Start K1 Power K2 Y11 Y12 24 34

Function description Single-channel operation: no redundancy in the input circuit, earth faults in the reset circuit are detected. Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects Timing diagram earth faults in the reset and input circuit, short circuits and shorts between contacts in the input circuit. Automatic start: Unit is active once the input circuit has been closed. Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. Increase in the number of available contacts by connecting contact expander modules or external contactors/relays. 1 2 a b POWER Reset/Start Output safe Semi t1 t2 t1 t2 t1 t2 t1 t2 Key Power: Supply voltage Reset/start: Reset circuit- : circuits -, -, 1-2 Output safe: Safety contacts 23-24, 33-34 Semi: Semiconductor output : Automatic reset : Manual reset a: circuit closes before reset circuit b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation Wiring Please note: Information given in the Technical details must be followed. Outputs 23-24, 33-34 are safety contacts. To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. -2

Preparing for operation Supply voltage Supply voltage AC DC A1 L+ A2 L- circuit circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts 2 1 E-STOP with detection of shorts across contacts 2 1 Safety gate without detection of shorts across contacts 2 1 Safety gate with detection of shorts across contacts S2 2 1

Reset circuit Reset circuit Automatic reset E-STOP wiring (single-channel) Safety gate (single-channel) E-STOP wiring (dual-channel) Safety gate (dual-channel) Manual reset Feedback loop Feedback loop Automatic reset Manual reset Contacts from external contactors 23 (33) 24 (34) L1 N 23 (33) 24 (34) L1 N Semiconductor output Y11 Y12 24 V DC SPS Key /S2 E-STOP pushbutton/ safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration A1 Y11 23 33 P 1 P 2 Y11 POWER Y11/Y12 CH.1 CH.2 23 33 Y12 24 34 P 2 1 2 P 1 A2 Y12 24 34 Installation The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions * with cage clamp terminals 121 (4.76") 94 (3.70") * 101 (3.98") 22,5 (0.88")

Notice Service life graph This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NLNominale bedrijfsstroom (A) 10 1 DC13: 24 V AC1: 230 V AC15: 230 V DC1: 24 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœvres x 10 3 NLAantal schakelingen x 10 3 Technical details Electrical data Supply voltage U B DC 24 V Voltage tolerance -15 % / +10 % Power consumption at U B DC 1.5 W Residual ripple DC 20 % Voltage and current at circuit DC: 24.0 V 25 ma Reset circuit DC: 24.0 V 50 ma Feedback loop DC: 24.0 V 50 ma Output contacts in accordance with EN 954-1, Category 4 Safety contacts (N/O): 2 Utilisation category in accordance with EN 60947-4-1 AC1: 240 V DC1: 24 V Utilisation category in accordance with EN 60947-5-1 AC15: 230 V DC13: 24 V (DC13: 6 cycles/min) Contact material External contact fuse protection in accordance with EN 60947-5-1 Blow-out fuse, quick Blow-out fuse, slow Circuit breaker Semiconductor outputs (short circuit-proof) External supply voltage Voltage tolerance Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC dual-channel with detect. of shorts across contacts at U B DC I min : 0.01 A, I max : 6.0 A P max : 1500 VA I min : 0.01 A, I max : 6.0 A P max : 100 W I max : 5.0 A I max : 4.0 A AgSnO 2 + 0.2 µm Au 6 A 4 A 24 VAC/DC: 4 A, characteristic B/C 24 VDC, 100 ma 24 VDC ±20 % 50 Ohm 20 Ohm -6

Times Switch-on delay with automatic reset typ. with automatic reset max. with manual reset typ. with manual reset max. Delay-on de-energisation with E-STOP typ. with E-STOP max. with power failure typ. with power failure max. Recovery time at max. switching frequency 1/s after E-STOP after power failure Simultaneity, channel 1 and 2 Supply interruption before de-energisation The standards current on 05/03 apply. 80 ms 130 ms 35 ms 130 ms 12 ms 20 ms 60 ms 90 ms 50 ms 150 ms 20 ms Environmental data EMC EN 60947-5-1 / EN 61000-6-2 Vibration in accordance with EN 60068-2-6 Frequency Amplitude 10-55 Hz 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage VDE 0110-1 Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. control cabinet) Housing Terminals Mechanical data Housing material Housing Front Max. cross section of external conductors on screw terminals 1 core flexible 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Max. cross section of external conductors with cage clamp terminals: Flexible without crimp connectors Cage clamp terminals: Terminal points per connection Stripping length Dimensions (H x W x D) with screw terminals Dimensions (H x W x D) with cage clamp terminals Weight IP54 IP40 IP20 PPO UL 94 V0 ABS UL 94 V0 0.25 2.50 mm 2 0.25 1.00 mm 2 0.20 1.50 mm 2 0.5 Nm 0.20 1.50 mm 2 2 8 mm 94 mm x 22.5 mm x 121 mm 101 mm x 22.5 mm x 121 mm 190 g Order reference Type Features Terminals Order no. C 24 VDC Cage clamp terminals 787 308 24 VDC Screw terminals 777 308