KiTorq Stator. Torque. Torque Evaluation Unit (Stator) for a Torque Measuring Flange. Type 4541A...

Similar documents
Torque Measuring Flange

Torque Measuring Flange

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

U10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en

FEATURES DESCRIPTION FEATURES

TU531, TU532 Terminal Unit

TF501, TF521 Terminal Bases

Absolute encoders - bus interfaces

Absolute encoders - SSI

GFK-2415A March Type of sensor connection

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Inclination sensors 2-dimensional, measuring range up to ±90

Syr-line TMR48D Digital Timer

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

02/11/2015

DI572 Digital Input Module

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

DI561 Digital Input Module

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Speed switches Programmable, digital speed switch With incremental encoder POG 10

DX561 Digital Input/Output Module

DC562, digital input/output module,

AI561 Analog Input Module

AO523 Analog Input Module

Absolute Encoder Multiturn

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

DC561, digital input/output module,

Technical data. Your advantages

M5100 Heavy Industrial Pressure Transducer

Syr-line TMR48D Digital Timer

Communications & Networking

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Inclination sensors 1-dimensional, measuring range

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

Output Voltage* (nom.)(adjustable)

Incremental encoders Solid shaft with EURO flange B pulses per revolution

Speed switches Programmable, digital speed switch With incremental encoder HOG 10

AO561 Analog Output Module

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Encoder WDGA 58B SSI.

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

port Professionals in Industrial Communication

NOVOHALL Rotary Sensor non-contacting. Series RSB-3600 Series RMB-3600

U7100 Pressure Transducer

1 General Classification Definition of the H&B Application Classes Assignment of the H&B Application Classes to Devices...

Encoder WDGA 36A SSI.

Output Voltage* (nom.)(adjustable)

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Data Sheet MEM 22. Absolute Encoder Multiturn

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

SIMOCODE 3UF Motor Management and Control Devices

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

RoHS. High shaft load capacity. Shock / vibration resistant

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Analog output 520AOD01 Data sheet

TMT470L Temperature Transmitter

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Installation Instructions Temperature transmitter TAA /00 06/2011

Rotary Measurement Technology Absolute Encoders, Singleturn

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Energy Management Energy Transducer Type ET112

TM3AI4 module TM3-4 analog inputs

Universal Power Supplies

Type VRLTC tap changer

Safety Standards. Model Number:

02/11/2015

Absolute encoder TBD/TRD with PROFIBUS-DP interface

CM592 PROFIBUS Communication Module

Tap Position Indicator - PI

CM597 Ethernet Communication Module

RT12-240V/2.4kW Rectifier Specification

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Transcription:

Kiorq Stator Evaluation Unit (Stator) for a Measuring Flange Kiorq Stator for supplying power to and capturing measurement data from torque measuring units in the Kiorq System, such as the ype 550A... rotor. Combinations of various rotors and stators High precision Low installation height Digital interface for measurement data capture and parameterization Freely scalable voltage and frequency outputs Description he Kiorq Stator and Kiorq Rotor ype 55xA make up the torque measuring flange Kiorq System. he stator supplies power to the rotor, receives and processes the measurement data, and provides voltage and frequency outputs. he outputs can be tared via the digital interface or by pressing a button. he outputs can be configured via the digital interface. his makes is possible, for instance, to use the output for measuring the torque with a different low-pass filter than a second torque output used for control purposes. It is also possible to convert the speed into a voltage signal. Different scaling factors can also be applied to different plugs. 51A_000-879e-0.1 he Kiorq Stator can be used together with a rotor from the Kiorq system. Using the ordering key, the stator can be purchased individually or as a calibrated torque measurement chain, together with a ype 55xA... rotor. he standard torque evaluation unit (stator) is shipped calibrated. Calibration of the entire measurement chain, consisting of the Kiorq Rotor and a Kiorq Stator, can be ordered using the rotor ordering key (such as the ype 550A...). Application Applications for the Kiorq Stator are found in test bench engineering, such as electric motor, gear, pump, and combustion engine test stands. Special applications for the individual components of the Kiorq System can be found on their corresponding data sheets. General echnical Data he accuracy class is determined by the Kiorq Rotor 55xA... emperature influence on the zero point K0 % FSO/ K 0,01 emperature influence on the nominal value KC % FSO/ K 0,01 Linearity error % FSO 0,01 Rel. standard deviation of repeatability % FSO 0,00 Zero point stability (8 h) % FSO 0,00 Limit frequency db khz Operating temperature range (Rated temperature range) C... 60 Service temperature range C 0... 70 Storage temperature range C 5... 80 Protection class IP5 Page 1/6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com

echnical Data Noise Immunity (EN 616-1, able ) Electromagnetic field (AM) V/m Magnetic field A/m 0 Electrostatic discharge (ESD) Contact discharge kv 8 Air discharge kv Fast transients (burst) kv 1 Impulse voltage (surge) kv 1 Conducted emissions (AM) V Mechanical Shock (EN 60068--7) Quantity n 1 000 Duration ms Acceleration m/s 650 Vibrational Loads in Directions (EN 60068--6) Frequency range Hz... 000 Duration h,5 Acceleration (amplitude) m/s 00 Speed Measuring Pulses/revolution 1x60 Dimensions 0,5,5 76,5 0,5,5 8,5 9,1 8,5 1 15 190 Fig. 1: Dimensions of Kiorq Stator torque evaluation unit (stator) (dimensions in mm) 51A_000-879e-0.1 Page /6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com

Electrical Connections Pin Allocation of the 7 Pin Built-in Connector X1 5 6 7 1 Supply output 0 % control +UB GND 18 0 VDC, power consumption <0 W Ground for +UB FA+ Frequency signal RS- 1 FA- Frequency signal RS- 5 DGND Ground for FA+ and FA- 6 Control Off: 0 VDC On:,5 0 VDC 7 GND Opto isolated ground for control Pin Allocation of the 1 Pin Built-in Connector X L S G U M A N O R P E C Speed impulse A rack A+ Active, L level C rack A Active, L level E G L Scaling selector switch U Normal (1:1) with 0... VDC Extended (1:5/1:) with,5... 0 VDC Scaling selector switch Acknowledgment output M VDC 0 VDC for Normal (1:1) VDC for extended (1:5 / 1:) aring N ara aring at,5 0 VDC for 1 second RS-C interface XD Serial transmission cable R RXD Serial receiving cable P DGND Ground for RS-C interface Input for 0 % control S Control Off: 0 VDC On:,5 0 VDC O GND Opto isolated ground for taring, control input, scaling selector switch, and acknowledgment Pin Allocation of the 7 Pin Built-in Connector X 5 6 7 1 Power supply +UB 18 0 VDC, power consumption <0 W GND Ground for +UB UA ±MNom Voltage output ± VDC at at > kω output VDC at control signal activation Ri,C = Ω, output short circuit proof 1 AGND Ground for UA 5 0 % control 6 Control Off: 0 VDC On:,5 0 VDC 7 GND Opto isolated ground for control 51A_000-879e-0.1 Page /6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com

Pin Allocation of the 1 Pin Built-in Connector X K B A C L H M D G F E Application Examples Supply F +UB 18 0 VDC, power consumption <0 W A GND Ground for +UB Shield M In the sensor, on the housing output C UA Voltage output Frequency output ± VDC at ±MNom at > kω FA Frequency signal VDC at control signal activation Ri,C = Ω, Output short circuit proof D AGND Ground for UA AGND Ground for FA Speed pulses H rack A Active, L level G Input K Control Off: 0... VDC 0 % control On:,5... 0 VDC RS-C interface B XD Serial transmission cable to the CoMo L RXD Serial receiving cable Digital mass potential E DGND Ground for speed impulses, calibration/control input and RS-C interface 8 1 7 6 5 est subject Drive shaft measuring unit Kiorq Rotor ype 55xA... Loading machine F Lever arm D Coupling (on request) Bearing support measuring unit Kiorq Rotor ype 55xA... Loading machine E C evaluation unit Kiorq Stator Fig. : Combustion engine test stand Fig. : Possibility for calibration D evaluation unit Kiorq Stator B 51A_000-879e-0.1 Page /6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com

Calibration Standard Calibration: he stator is calibrated as a standard. When a torque measurement chain with a Kiorq Rotor, the rotor and stator are calibrated to WKS 1 as a measurement chain. he measurement chain calibration is specified solely by the ordering key of the Kiorq Rotor. he following signals are set as standard: Frequency: 0 khz ± khz Analog: ± V he following signals are calibrated as standard: Analog ± V at output X When a second scaling factor is selected (1:5 or 1:), both ranges are calibrated at output X and can be selected there. Special Calibration: Upon request, additional calibrations can be ordered (e.g. second scaling factor, another frequency,...). he torque measurement chain, consisting of the Kiorq Rotor and Kiorq Stator, has its own separate calibration certificate and a serial number. If one of the components is replaced (e.g. with a Kiorq Rotor with a different nominal torque), then the virtual calibration values for the new measurement chain can be calculated from the individual calibration certificate for the rotor and stator. All output settings can be changed afterward by the customer. he calibration certificates apply only to the settings at delivery, according to the order. Definition of Calibration erms: WKS 1: Works calibration at 5 points right, points left WKS : Works calibration at 5 points right and left, and repeat series DAkkS: Calibration per DIN 59 Available Customer-Specific Special Settings/Calibrations Frequency khz 0 ± 0 ±0 ±5 Scale 1:1 1:5 1: 1:1 and 1:5 1:1 and 1: Voltage V Scale 1:1 1:5 1: 1:1 and 1:5 1:1 and 1: Frequency: X1 X Kiorq Stator Possible configurations X X Voltage: Frequency khz Frequency: Voltage V 51A_000-879e-0.1 Frequency khz 0 ± 0 ±0 ±5 Scale 1:1 1:5 1: 1:1 and 1:5 1:1 and 1: Our calibration service DAkkS-K-17650-01 provides traceable calibrations for torque sensors from all manufacturers. Page 5/6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com

Dimensions of the spacer plate Spacer Axis height 0 N m/ 00 N m h= 1 mm 500 N m/ 1 000 N m h= 1 mm 000 N m/ 000 N m h= 161 mm 5 000 N m h= 175,5 mm AH ype KSM [mm] ype KSM [mm] ype KSM [mm] ype KSM [mm] 157,5 0860,5 1 167,5 0687,5 1 185,5 0687 1,5 1 0860,5 1 19,5 0859 61,5 0,5 Zeichnung für Dokumentation / Iancu / 97.11-09 0687 1,5 1 0969 7 1 0,5 06876 60,5,5 0859 61,5 6,5 9,5 0969 6 6,5 1 M 8 (x) measuring unit ype 550A... 1 M 6 (x) evaluation unit 190 0, 190 150 0, AH h 0 9 (x) Included Accessories Calibration certificate Dimensions of the torque evaluation unit with spacer plate (total axis height AH) 51A_000-879e-0.1 Optional Accessories ype/art. No. Connection cable, length 5 m, 7 pin open ends KSM197-5 Connection cable, length 5 m, 1 pin open ends KSM1970-5 Connection cable, length,5 m, 1 pin to CoMo KSM1860-.5 Connection cable, length 5 m, 1 pin open ends KSM8570-5 Cable socket 7 pin (plug X1/X) KSM000517 Cable socket 1 pin (plug X) KSM00070 Cable socket 1 pin (plug X) KSM0890 Spacer plate 1,5 mm, AH 157,5 KSM06870 Spacer plate,5 mm, AH 167,5 KSM0687 Spacer plate 1,5 mm, AH 185,5 KSM0687 Spacer plate 60,5 mm, AH 0,5 KSM06876 ControlMonitor CoMo 700B... Evaluation instrument for torque sensors Adapter flanges (on request) 05A... Couplings (on request) 05A... Sensorool 706A Ordering Key Speed Speed measuring with 1x60 Imp./Rev. Order Example: N1 ype 51A ype 51AN1 evaluation unit ype 51A, speed measuring 60 impulses/revolution: N1 Page 6/6 011... 01, Kistler Group, Eulachstrasse, 808 Winterthur, Switzerland phone +1 5 11 11, Fax +1 5 1 1, info@kistler.com, www.kistler.com