The client device could be another PLC (Quantum, M340, Premium...) or any other device that supports Modbus TCP client communication.

Similar documents
Technical Note. ProSoft Technical Publications. RLXIC-Sx Serial Cellular Radio Application Setup Guide

Using Add-On Instruction and CIPconnect TM

Technical Note PLX82-MNET-61850

Technical Note. Rockwell Automation ControlLogix PLC Communications with 4B Watchdog Super Elite via a ProSoft Technology PLX31-EIP-MBTCP

AW5800HTP-PAIR USER S MANUAL

Using RLX2-IHx Bridging Client on Cisco Wireless Infrastructure

EKI-6332 & EKI-136x- MB_setup example SOP. Revision Date Revision Description Author April/2018 V1.0 Initial release ICG AE Jacky.

How to configure a Point-to-Point link

How to configure a Point-to-Multipoint link

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO

Technical Note. MVI56(E)-MNETR Add-On Instruction Installation Guide

Quick Installation Guide DIR-300NRU. Wireless Router with Built-in 4-port Switch

Lab - Configure Wireless Router in Windows

Enabling RUGID RTUs to Communicate Over Ethernet

Lab - Connect to a Router for the First Time

EnGenius Quick Start Guide

PePWave Mesh Connector User Manual

Quick Installation Guide DSL-2640U/NRU. ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Radiolabs Bridge in a Box Setup

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide

MatchPort E Embedded Device Server Demonstration Kit Quick Start Guide

How to setup the range extender by using the

Application Note #5494 Upgrading Plus Ethernet Radio Firmware September 9, 2013

User guide for TRANZEO-Series 6000

Configuring RAD-900-IFS with GW MODBUS TCP/RTU for Modbus TCP Communication

RLX-FHS Wireless Serial Modem. Quick Start Guide

Mega 100WR ADSL 2+ Router - Easy Start

Part I: External Installation Direction

Quick Start Guide. System Release 1.0. Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window.

802.11g Wireless Access Point

Collector Quick Start Guide

Quick Installation Guide DSL-2650U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Grandstream Networks, Inc. GWN76xx Wi-Fi Access Points Master/Slave Architecture Guide

A5500 Configuration Guide

Dongle-sized Wireless Print Server. Quick Installation Guide V1.0

Add a Wireless Network to an Existing Wired Network using a Wireless Access Point (WAP)

Quick Setup Guide. for Standalone Omada Access Points. EAP110 / EAP115 / EAP225 / EAP245 / EAP320 / EAP330 / EAP115-Wall

RAPIDUS WIRELESS RL-SERIES USER GUIDE

How to manually set up EW-7228APn to extender wireless range

User Manual of 5.8G Outdoor CPE

Point to Multi-point Link: Bridge Mode

VIEW Certified Configuration Guide. Extreme Networks. Summit WM 100, 1000 Wireless Controllers with Altitude AP

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 12/2012

How to configure an Anybus Modbus-TCP slave module with Unity Pro L

Networking the printer

SMG-1100/6100 User s Manual

Pakscan P3 Wireless Quick Start Guide

AOS-W 3.1. Quick Start Guide

Analyzer Quick Start Guide

Technical Note. Converting Modbus applications from a 3150-MCM to an MVI46-MCM. Document Code: TN Author: Steve Crippen Date:

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. Access Point WIRELESS WAP54G (EU/LA/UK) Model No.

123 Manual, LP-1522 Broadband Wireless AP/Router Client Mode Installation. 123 Manual, LP-1522 Broadband Wireless AP/Router Client Mode Installation.

Setup Guide for Wi-Fi Hotspot Boosting Kit

Quick Setup Guide AMG Skywave III AMG8300S series Wireless Radios Products

Mini-102MG ( MFP Server) Quick Installation Guide. User's Manual Version : Mini-102MG_QIG_EU-A_V1

MVI56E-LDM QUICK START GUIDE. ControlLogix Platform. C Programmable Linux Application Development Module

BR411AP n Wireless Access Point and Bridge

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Anybus CompactCom 40 Diagnostic Events for Modbus-TCP APPLICATION NOTE

SOHO 6 Wireless Installation Procedure Windows XP with Internet Explorer 5.x & 6.0

MULTIBAND Dual Radio V4

XPort Development Kit Quick Start Guide. XPort Quick Start Guide

WiFi 16 Relay Board TCP ModBus Controlled - User Manual 21 Aug WiFi 16 Relay Board TCP ModBus Controlled

NETWORK LAB 2 Configuring Switch Desktop

4 Enter an IP address and sub-net mask for the ftp server and. 5 Go to the [System and Maintenance] > [Administrative Tools]

It is a Plug & Play Solution It is a bundle, containing an HP5100S and an NHP5010

The SC receives a public IP address from the DHCP client of the ISP. All traffic is automatically sent out through the WAN interface.

ZyAIR B-500 Wireless Access Point Quick Installation Guide

JNR1010v2 N150 Wireless Router User Manual

PLX35-NB2 RELEASE NOTES. Network Bridge Stand Alone Gateway. July 20, 2018

Lab 7.5.1: Basic Wireless Configuration

(B) Execute SMS TCP MODBUS Interface Application

Chapter 1 Introduction

Step 1 - Connect the WAN interface on the rear panel of the HG256s to the network jack with a network cable.

Configuring the network clients

Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA Phone Fax

802.11g Super-G 108Mb Wireless Access Point Quick Installation Guide

Wireless Presentation System User s Manual

WRE6505 v2. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1, 10/2016

Quick Installation Guide

ShareLink 200 N Setup Guide

XFINITY Voice and Internet Wireless Gateway

5209-MNET-CCLINK SETUP GUIDE

What can I do in the settings menu of my WL-330 (which settings are there and what can I change)?

Contents. LaFonera_Software_Client-Mode. You are here: DD-WRT wiki mainpage / LaFonera / Software / Client-Mode

802.11ac Wireless Access Point Model WAC104

Wireless-G VPN Router with RangeBooster. Quick Install Guide

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

WR300N Portable Wireless-N Repeater

2013 Moxa Inc Released on Sep 15, 2013

802.11b/g Mesh Outdoor AP User Guide

FEATURES HARDWARE CONNECTION

User Manual. Configuration and Administration Industrial Wireless LAN Client BAT-C. Technical Support

ShareLink 200 N Setup Guide

WRE6606. User s Guide. Quick Start Guide. Dual-Band Wireless AC1300 Access Point. Default Login Details. Version 1.00 (ABDU.0) Edition 1, 10/2016

QUICK START GUIDE. WK-2x Access Point. WK-2, WK-2-B, WK-2-C / ac Dual Band Access Version 1.1

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

S-series Virtual I/O Module 2

Figure 5-25: Setup Wizard s Safe Surfing Screen

Transcription:

Implementing Modbus TCP over Wireless Introduction This document gives the details of the implementation of Modbus TCP over wireless connection between two devices (one client device and one Server device). For the architecture example of this implementation, we use a Schneider Electric Modicon QUANTUM PLC as client device and a PC running Modsim32 simulator as server device. The client device could be another PLC (Quantum, M340, Premium...) or any other device that supports Modbus TCP client communication. The server device could be another PLC (Quantum, M340, Premium...) or any other device that supports Modbus TCP server communication. To carry out the wireless communication, two ProSoft Technology modules RLX- IHW-E RadioLinx Industrial Hotspot 802.11abg are used. ProSoft Technology www.prosoft-technology.com Worldwide Sales and Technical Support network Locations in North America, Latin America, Europe / Middle-East / Africa, Asia / Pacific Where Automation Connects.

Architecture MODICON QUANTUM PLC CLIENT SERVER RLX-IHW Master mode RLX-IHW Remote/Repeater mode Software required for this architecture example: Unity Pro XL From Schneider Electric RadioLinx Industrial Hotspot Browser From ProSoft Technology ModSim32 From WinTECH Software Design Page 2 sur 36

Procedure Here are the basic steps needed to establish communications: A. Setting of the master radio. A.1. Install RadioLinx IH browser: Download RLX-IH Browser from: http://www.prosoft-technology.com/content/download/12739/165690/file Then install the Browser on your PC. A.2. Plug the cables to the RLX-IHW: From left to right: Ethernet port, serial port and power connectors. Plug the power cable. For Ethernet connection: o If you are connecting to the radio through an Ethernet hub or switch, use the gray (straight-through) cable. o If you are connecting to the radio directly from your PC without going through an Ethernet hub or switch, you must use the red (crossover) cable. Page 3 sur 36

A.3. Launch RadioLinx IH browser: Click on the binocular: Technical Note The radio appears: At this point the setting of the radio is the factory default. If the radio is connected to a network with a DHCP server, the radio may already has an IP address assigned to it. Page 4 sur 36

If no IP address appears: Select the Radio on the list Technical Note Then from Operations menu, select Assign IP The following window is displayed: Click OK to accept the temporary IP address, subnet mask, and default gateway. Now a temporary IP address is assigned to the RLX-IHW-E module. Page 5 sur 36

A.4. Go online with the RLX-IHW-E for configuration: To go online to the RLX-IHW for configuration (or diagnostics), from the Browser select the Radio1: Select the Connect option in Operation menu. The following window is displayed: Enter your password to log in to the radio and then press Login. Page 6 sur 36

The RLW-IHW-E configuration is protected by a login password. The default password is password (lower case). To prevent unauthorized access to the radio configuration, you should change the default password when you have finished your configuration. The following window is displayed: Page 7 sur 36

A.5. Set up the RLX-IHW-E Master mode Technical Note The master is the "root" or top-level radio in a network. You must have at least one master radio per network. For redundancy, you can assign more than one master to the network. From the screen: Change the name of the radio from Radio1 to Quantum_Radio Change the SSID name from Network1 to Modbus Select Master and leave the channel per default (11) Encryption chose WPA-AES and enter your WPA phrase Enter a valid IP address and Subnet Mask Page 8 sur 36

Now the new settings are ready, press Apply Changes to valid them. The RLX-IHW-E reboot: Press Close on this window. Page 9 sur 36

A.6. Settings verification: Select Clear to delete the current radio list Select the binocular to refresh the screen and get an update radio list When configured the name of the radio is preceded by an M (for Master) in the RLX-IH Browser. The setting of the Master radio is finished. Disconnect the Ethernet cable from the radio. Page 10 sur 36

A.7. RLX-IHW-E Access Point checking Technical Note Open your PC network connection and select the wireless card. Select to View Available Wireless Network Within the list of the Wireless network available you should see the Modbus network. This is the Network SSID you setup previously within the RLX- IHW-E Master mode. Choose the Modbus Wireless network. Page 11 sur 36

Now you will be able to monitoring the radio with internet explorer via wireless network: Open Internet explorer. Enter the IP address of the RLX-IHW-E you want to access into the navigation bar. Page 12 sur 36

The following window is displayed. Technical Note Enter your password to log in to the radio and then press Login. The following window is displayed: The RLX-IHW-E Master mode works fine. Page 13 sur 36

B. Setting of the repeater radio B.1. Plug the cables to the RLX-IHW Technical Note From left to right: Ethernet port, serial port and power connector. Plug the power cable. For Ethernet connection: o If you are connecting to the radio through an Ethernet hub or switch, use the gray (straight-through) cable. o If you are connecting to the radio directly from your PC without going through an Ethernet hub or switch, you must use the red (crossover) cable. Page 14 sur 36

B.2. Launch RadioLinx IH browser Click on the binocular Technical Note The radio appears: At this point the setting of the radio is the factory default. If the radio is connected to a network with a DHCP server, the radio may already has an IP address assigned to it. Page 15 sur 36

If no IP address appears: Select the Radio on the list Technical Note Then from Operations menu, select Assign IP The following window is displayed: Click OK to accept the temporary IP address, subnet mask, and default gateway. Now a temporary IP address is assigned to the RLX-IHW-E module. Page 16 sur 36

B.3. Go online with the RLX-IHW-E for configuration To go online to the RLX-IHW for configuration (or diagnostics), from the Browser select the Radio1: Select the Connect option in Operation menu. The following window is displayed: Enter your password to log in to the radio and then press Login. Page 17 sur 36

The RLW-IHW-E configuration is protected by a login password. The default password is password (lower case). To prevent unauthorized access to the radio configuration, you should change the password when you have finished the initial configuration. The following window is displayed: Page 18 sur 36

B.4. Set up the RLX-IHW-E Remote/Repeater mode A RLX-IHW-E Remote/Repeater connects automatically to the best available parent radio on the network. Change the name of the radio from Radio1 to Remote_device Change the SSID name from Network1 to Modbus Select Repeater Encryption chose WPA-AES and enter your WPA phrase Enter a valid IP address and Subnet Mask. Important: The Network SSID and WPA phrase are case sensitive. Use exactly the same combination of upper case and lower case letters you entered for the RLX-IHW-E Master mode, otherwise the Repeater radio will not be able to connect to the Master radio. Page 19 sur 36

Now the new settings are ready, press Apply Changes to valid them The RLX-IHW-E reboot: Press Close on this window. Page 20 sur 36

B.5. Settings verification Select Clear to delete the current radio list Select the binocular to refresh the screen and get an update radio list When configured the name of the radio is preceded by an R (for Repeater) in the RLX-IH Browser. The setting of the Repeater radio is finished. Disconnect the Ethernet cable from the radio. Page 21 sur 36

B.6. RLX-IHW-E Access Point checking Technical Note With you PC wireless access enabled and from the Available Wireless Network list Choose the Modbus network. This is the Network SSID you setup previously within the RLX-IHW-E Remote/Repeater mode. Page 22 sur 36

Now you will be able to monitoring the radio with internet explorer via wireless network: Open internet explorer. Enter the IP address of the RLX-IHW-E you want to access into the navigation bar. Page 23 sur 36

The following window is displayed. Technical Note Enter your password to log in to the radio and then press Login. Page 24 sur 36

The following window is displayed: Technical Note Signal quality: Signal Strength shows you the quality of the signal between the RLX- IHW-E Master mode and RLX-IHW-E Remote/Repeater mode radios. Good Signal Poor Signal Note: Signal quality depending of: Distance between the antennas. Free line of sight. Antennas correctly mounted. To have further information about RLX-IHW-E please, download the User Manual from: http://www.prosoft-technology.com/content/download/12698/165429/file Page 25 sur 36

C. Setting of the Modbus TCP Client device. C.1. Launch Unity Pro XL Technical Note For this application we use a CPU 31110 and Ethernet Card NOE77111. After creating your material configuration select in the project browser ETHERNET_1: Page 26 sur 36

In the displayed screen, enters the IP Address of the NOE77111 Card in the project browser: Note: The IP address of NOE77111, Radio RLX-IHW and laptop must be at the same IP range and depending of your Subnet mask. Page 27 sur 36

C.2. IO Scanning setting: Select IO Scanning tab Server IP Address: Address IP of your Laptop (192.168.170.180). Unit ID: Modbus Address of the server (1). Timeout (ms): need to be set a 1 sec (1000). RD Master Objet: Master Address where the data read are stocked (%MW1). RD Slave Index: Offset for the first data read in slave (1). RD length: Number of data read (10). WR Master Objet: Master Address where write data reads are stocked (%MW100). WR Slave Index: Offset for the first data read in slave (10). WR length: Number of data read (10). Page 28 sur 36

D. Setting of the Modbus TCP Server device. Modsim32: Launch Modsim32. Create a new File. Technical Note Select the data Read area. Page 29 sur 36

Create a new File and select data write area. Select Tile in Window menu. Page 30 sur 36

Connect Modsim32 on Modbus TCP as shown below. Page 31 sur 36

E. Communication checking Technical Note Now the communication between the Client and the server is established. Create a new Modbus TCP animation table: The data mapping of the animation table must be the same that the area memory selected in IO Scanning. Page 32 sur 36

Communication testing Reading data The value of data which is changing in Modsim32 is updating in the Client PLC s memory. Client Memory Server Memory DATA READ Page 33 sur 36

Communication testing Writing of data The data value into the client PLC s memory is written into server s memory. Technical Note Client Memory Server Memory DATA WRITE Page 34 sur 36

F. Contact details For further information feel free to contact us at: ProSoft Technology sarl 17 rue des Briquetiers 31700 Blagnac - France Support.EMEA@prosoft-technology.com +33 (0)5 3436-8720 Corporate Phone +33 (0)5 6178-4052 Fax Page 35 sur 36

www.prosoft-technology.com