SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

Similar documents
SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

SSW5/USB. S5-PLC to USB converter cable US US13. User Manual. Edition 2 / / HW1 and higher

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter

Manual. CAN 300 PRO CANopen Slave. CAN Communication Modules for S7-300 as CANopen Slave. Edition 3 /

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

Quick Start Guide NETL ink Ethernet Gateways

Whitepaper. IPSec Client/Router. Version /1/2016

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

GFK-2415A March Type of sensor connection

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PAS 300, PROFIBUS Slave Interface Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Quick Start Guide WALL IE. Version. 7 en. as of FW

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

AI561 Analog Input Module

Brief instruction. Version. 3en.

AO561 Analog Output Module

CAN 300 / CAN 400 Application Example DS402 ERL

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

General information. Display. Supply voltage. Input current. Encoder supply. Output current

This data sheet is only valid in association with the IL SYS INST UM E user manual.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

General information. Display. Supply voltage. Input current. Encoder supply. Output current

EasyConnect PROFIBUS-Connector, 90

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

DI572 Digital Input Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

MINI MCR-SL-UI-2I(-SP)(-NC)

DI561 Digital Input Module

MGate 4101-MB-PBS Series

PHOENIX CONTACT - 07/2006

Whitepaper. OpenVPN Client/Router. Version 1 / 12/15/2015

User s Manual. INAT echolink Serial / Industrial Ethernet- Converter. Manual-Version e

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Gateway 1400 Reference Manual

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

HARDWARE MANUAL ENGLISH

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

VersaMax IP Input Module

Serial PROFIBUS Interface

TF501, TF521 Terminal Bases

DX561 Digital Input/Output Module

TU531, TU532 Terminal Unit

AO523 Analog Input Module

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

MINI MCR-SL-PT100-UI(-SP)(-NC)

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

DC562, digital input/output module,

Manual Fiber Optic Interfaces

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Modbus TCP/RTU Gateway

Features and Benefits. Certifications

M-Bus-Logger Data Logger

IXXAT CME/PN. CANopen-PROFINET Gateway HARDWARE MANUAL ENGLISH

AXL E IOL AO1 U M12 R

Hardware Manual RM CANview Gateway

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

AI531 Analog Input Module

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Control Panel CP600-eCo CP604, CP604-B

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

NETLink PRO family. Application Examples with RFC Edition 7 / Helmholz products S7/S5 OPC-Server V (Company Helmholz)

Transcription:

SSW7-RK512/RS422 Adapter for MPI Bus with RK512 Protocol, RS422 700-752-5VK21 User Manual Version: 1 / 24.03.2009 HW: 1 / FW: 2.05 and later Order number of manual: 900-752-5VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135 7380-110 E-Mail: info@helmholz.de Internet: www.helmholz.de

All rights are reserved, including those of translation, reprinting, and reproduction of this manual, or parts thereof. No part of this manual may be reproduced, processed, copied, or transmitted in any way whatsoever (photocopy, microfilm, or other method) without the express written permission of Systeme Helmholz GmbH, not even for use as training material, or using electronic systems. All rights reserved in the case of a patent grant or registration of a utility model or design. Copyright 2009 by Systeme Helmholz GmbH Hannberger Weg 2, 91091 Grossenseebach, Germany Note: We have checked the content of this manual for conformity with the hardware and software described. Nevertheless, because deviations cannot be ruled out, we cannot accept any liability for complete conformity. The information in this manual is regularly updated. When using purchased products, please heed the latest version of the manual, which can be viewed in the Internet at www.helmholz.de, from where it can also be downloaded. Our customers are important to us. We are always glad to receive suggestions for improvement and ideas. Step and SIMATIC are registered trademarks of SIEMENS

Design The SSW7-RK512/RS422 enables the conversion of a serial interface (RS422 level, 9.6 to 19.2 Kbaud) with the RK512 protocol to the MPI bus (RS485 level, fixed 187.5Kbaud) for connecting operator terminals or visualization software. The SSW7-RK512/RS422 has a 1.2m long connecting cable that can be directly plugged into the CPU connector of the PLC or at any other point in the MPI network. The housing of the SSW7-RK512/RS422 contains a 9-way SubD connector. The RS422 is a 4-wire connection and can currently only be used for a point-to-point link (the transmitter is never off). The SSW7-RK512/RS422 receives its power supply from the CPU via the MPI cable. If 24V are not available at the point of connection or if several SSW7s are connected to a CPU at the same time, the 24V power supply can be fed from an external source. The connection to the MPI bus can be extended with an additional cable. For that purpose, Systeme Helmholz GmbH offers the following products: MPI bus extension cable, 5m MPI bus extension cable, 10m MPI bus extension cable, special length 700-751-6VK11 700-751-6VK21 700-751-6SO11 When extending the MPI bus, please follow the relevant configuring guidelines as defined in the documentation of your PLC. The SSW7 and the extension cable do not contain any terminating resistors. i A standard rail bracket (700-751-HSH01) is available for the SSW7- RK512/RS422. SSW7-RK512/RS422 4

Transmission The SSW7-RK512/RS422 converts the RK512 protocol to the MPI bus. the RK 512 protocol transmits data with the 3964/R procedure. The BCC of the 3964/R procedure is always activated in the SSW7-RK512/RS422. The transmission format is predefined as 8 data bits, even parity, and 1 stop bit. Data words, flags, input and output bytes can be transmitted. In general, only fetch and send requests from the serial partner are supported. The programmable controller cannot access the SSW7-RK512/RS422 or the communication partner behind it on its own initiative. As the RK512 protocol only supports word-oriented addressing of data words, the word address is converted to a corresponding byte address. If DW10 is specified as the source or destination address, the SSW7-RK512/RS422 requests DBW20 (DBB20 & DBB21) from the CPU. In the case of inputs, outputs, and flags, however, both the RK512 and the MPI bus are byte oriented, i.e. there is no conversion. The SSW7-RK512/RS422 supports continuation frames for which the standard block size is 128 bytes. The highest addressable byte address is 255 and the highest word address is 254. The SSW7-RK512/RS422 is set to address 5 in the factory and establishes a connection with address 2. The destination address and the local address can be set in DB0. The SSW7-RK512/RS422 first signs on to the bus and then establishes a connection with the destination CPU if a valid RK512 frame has been received from the serial partner. A description of the RK512 protocol is available on request. Extended protocol In addition to the standard RK512 protocol, the SSW7-RK512/RS422 also contains a proprietary protocol extension for addressing all memory areas of S7 controllers. Before the protocol extension can be used, the protocol driver on the PC or operator terminal must be adapted by the manufacturer. A description of the extended RK512 protocol is available on request. SSW7-RK512/RS422 5

Parameterization Data block 0 The RK512 protocol has not been developed for communication with several nodes in a network. To allow communication with several nodes of an MPI network or to operate several adapters in a network nevertheless, it is possible to set the local address and the destination address of the adapter with an RK512 frame. To do this you must send an RK512 frame from the PC (operator terminal, etc.) to the DB0. The adapter has its own DB0 in which the following parameters can be defined: DW0 = reserved DW1 = reserved DW2 = Address of the SSW7-RK512 in the MPI network (default: 5) DW3 = Address of the destination CPU (default: 2) DW4 = Highest station address (default: 15) DW5-10 = Timeout times You can only set the local address of the adapter and the highest station address before you have sent a normal RK512 frame to a PLC for the first time after Power On. You can change the destination CPU address at any time. Of course, the RK512 frame to the DB0 will not be sent on to the PLC. The DB0 can also be read out. SHTools V3 The parameters of SSW7-RK512/RS422 can also be set with Windows program SHTools V3. The settings are then permanently stored in the adapter, i.e. even after Power Off the adapter automatically works with the set parameters. SHTools V3 can also be used to test the SSW7-RK512/RS422 and install a new operating system on it. The latest version can be downloaded from the download page in the Internet at www.helmholz.de To connect the SSW7- RK512/RS422 to a PC you require a RS232-RS422 converter, e.g. from Wiesemann&Theis GmbH (www.wut.de). SSW7-RK512/RS422 6

LED displays The three LEDs on the top of the device provide you with information about the operating status of the SSW7. You can use them to locate sources of error quickly. The LEDs have three different states: Off, on, blinking. If the LED is off, none of the labeled states apply. Upper LED off: Upper LED on: Upper LED blinking: Center LED on: The adapter has no power or is defective The adapter is being supplied with 24V and the processor is in operation SSW7-RK512/RS422 The SSW7-RK512/RS422 is registered in the MPI network Center LED blinking: The SSW7-RK512/RS422 has invalid parameterization Lower LED on: Lower LED blinking: The SSW7-RK512/RS422 has established a connection The SSW7-RK512/RS422 is transmitting data Error numbers Code hex. Code dec. Description Source: RK512 receiver 10 16 Syntax error 11 17 Unknown command (only "E" and "A" are possible) 12 18 Unknown object identifier (only "D,M,E,A" are possible) 13 19 Length error 14 20 Illegal MPI destination address (DW3 in DB0) 15 21 Flash cannot be written to 16 22 Unusable time parameters 1F 31 Timeout MPI bus 20 32 DB does not exist or is too short Source: Destination CPU 30 48 Local MPI address collides with exist. address on bus 31 49 Incorrect protocol execution, link disconnected 32 50 Receive response to old request 33 51 Unexpected disconnection 34 52 Incorrect response received 35 53 Logical connection rejected (too many channels assigned) 37 55 Frame sequence error 38 56 Unexpected response received 39 57 Destination CPU does not respond 3A 58 Logical connection cannot be established 3B 59 Connection buildup aborted 3C 60 Destination CPU not in ring 3D 61 Too many retries during connection SSW7-RK512/RS422 7

Technical data Order number SSW7-RK512/RS422 700-752-5VK21 Dimensions Weight MPI interface Type: Transmission rate: Cable: Connection: Communication interface Type: Transmission rate: Connection: Power supply Voltage: Current consumption (max.): Degree of protection IP 30 105 x 53 x 29 mm (LxWxH) approx. 180g (incl. MPI cable & connector) RS485, electr. isolated 187.5 kbit/s 1.2m, no terminating resistors Connector, SUB D 9 way RS422, serial asynchronous 19.2 kbit/s to 19.2 kbit/s automatic detection! Connector, SUB D 9-way +24V DC±25%, from the programmable controller or external supply (polarized) 70 ma Electromagnetic compatibility (EMC) Interference emission Class B acc. to EN55022 Interference immunity on signal lines ±2kV acc. to EN61000-4-4 Interference immunity ESD ±6kV contact discharge EN61000-4-2 ±8kV air discharge EN61000-4-2 RF radiation fields 10V/m acc. to EN61000-4-3 Conducted RF interference 10V acc. to EN61000-4-6 Climatic conditions Temperature during operation Temp. storage/transport Relative humidity operation Relative humidity storage -20 C to +60 C -20 C to +60 C 5% to 85% at 30 C (no condensation) 5% to 93% at 40 C (no condensation) Special features Quality assurance acc. to ISO 9001:2000 Maintenance Maintenance free (no battery) SSW7-RK512/RS422 8

Pin assignment Pin SUBD connector RS 422 SUBD connector MPI 1 Rx B n.c. 2 Rx A M24V 3 Tx B DATA.B 4 Tx A RTS AS 5 GND 0V (M5V) 6 n.c. +5V 7 n.c. +24V 8 n.c. DATA.A 9 n.c. RTS PG SubD 9pol. RS422 Connecting cable MPI extension cable (700-751-6VKx1): SSW7-RK512/RS422 9