Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

Similar documents
THE OFFICIAL TRADE JOURNAL OF BICSI

Key Elements of a Successful Data Center Cabinet Ecosystem

Power IQ for econnect

Polar PDUs POWER MANAGEMENT

Features and Benefits: Power IQ DCIM Monitoring Solutions

Features and Benefits: dctrack DCIM Operations Solution

Data Center Infrastructure Management (D.C.I.M.)

Rack PDU Marketing Playbook

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

DCIM Data Center Infrastructure Management

SALAMANDER. Automated Infrastructure Management

Frequently Asked Questions

DCIM Data Center Infrastructure Management

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

:: While reducing energy costs remains a factor, the most commonly reported driver of DCIM investment plans is capacity planning -Gartner*

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

G5 PDU Installation Guide

Geist EMEA. Geist USA. Geist APAC

dctrack Proactively Manage, Control Change and Reduce Costs In Your Data Center Overview Benefits Fastest and Easiest User Interface

Power Monitoring in the Data Centre

Preventing Outages by Monitoring, Managing, and Controlling the Data Center Environment

Kako optimizovati operativni rad data

DCIM Data Center Infrastructure Management Measurement is the first step

APC by Schneider Electric Elite Data Centre Partner

Leveraging DCIM to Increase Energy Efficiency and Savings

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Switched, Outlet Level Monitoring

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

EDGE LM XLMA Series Data Module

The Most Comprehensive DCIM Solution

Data Centre Solutions Expertly Engineered APC Management Software

WHITE PAPER. Solutions OnDemand Hosting Overview

Basic vs. Intelligent PDUs. Understanding the Differences

PX INTELLIGENT RACK PDUS

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Out of Band Networking Device, Infrastructure, and Environmental Management for Communications Networks

INNOVATE DESIGN APPLY.

Product Brochure. Eaton epdu G3 Managed

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Data Centre Monitoring. Nexans Cabling Solutions

Engineering and Manufacturing Excellence in Data Centre Infrastructure

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

Power & Cooling Considerations for Virtualized Environments

APC APPLICATION NOTE #74

ABB DATA CENTER FORUM 2017, 11 JULY 2017, TUESDAY Remote Power Panels with unique power density - giving you more in less space Nico Ninov, Market

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

Green IT and Green DC

Data Center Infrastructure Management (DCIM) Demystified

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

PDU - Overview / Non-Intelligent PDU s

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

You Might Know Us As. Copyright 2016 TierPoint, LLC. All rights reserved.

INNOVATE DESIGN APPLY.

Solutions Guide for Cisco UCS B and C Series Servers

Data Center Infrastructure Management ( DCiM )

Product Brochure. Eaton epdu G3 Managed

Strategies for managing distributed IT environments. Anne-Marie Gignac Vice President Networking Solutions Schneider Electric

Server Technology Inc.

84 kw, Tier 3, Direct Expansion, 937 ft 2

Data Center Lifecycle and Energy Efficiency

VERTIV RACK PDUS. Power Perfectly Configured for Your IT Application

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Comprehensive Data Center Energy Management Solutions

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Deploying High Power to IT Equipment Racks

Eaton Open Data Centre Solutions. Kari Koli

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

APPLICATION BRIEF. Branch Circuit Monitoring: Power Monitoring and Measurement in Production Facilities. Moving Away From a Break-Fix Model for Power

Product Brochure Eaton 93PR UPS kw

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

Deploying High Power to IT Equipment Racks

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

IBM Integrated Server Farm (ISF)

PX Intelligent Rack PDUs

Next Generation Data Center Facilities Design. Presenter: Ping Lin

How to Increase Data Center Efficiency

Building a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available

Data Center Solutions Brochure

Getting Power Peace of Mind with Remote Data Center Monitoring and Management Through EcoStruxure IT

Power and Cooling for Ultra-High Density Racks and Blade Servers

5 GREAT REASONS to Use Colored Rack PDUs

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

StruxureWare TM. Data Center Expert. Data Center Infrastructure Management (DCIM) Software

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Transcription:

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

Learning Outcomes Need for Remote Management of Whitespace Understand Elements of Whitespace Management Solutions to Minimize Management Challenges

Edge Computing and IoT Colocation and Managed Data Centers Lights Out Data Centers Data Center Trends Need for Remote Management

White Space Initiatives and Solutions Initiatives High Availability Capacity Optimization Low Operating Costs Efficiency Manageability Security and Regulatory Compliance Solutions High Density Solutions Power Management Environmental Monitoring Access Control Datacenter Infrastructure Management (DCIM)

Power Management Last Leg of the Power Chain Resides Within White Space

Power Management: What? Consumption vs capacity Branch circuit metering Redundancy monitoring Chargeback reports Equipment level consumption

Power Management: How? Invest in remotely manageable intelligent hardware Rack Power Distribution Units (PDUs) and Remote Power Panels (RPPs) Choose rack PDUs with high temp ratings Deploy DCIM to provide snapshot health information as well as trend reports

Power Management: RPP / Floor PDU METERING PARAMETER ADVANTAGES Input and Output Voltage Monitor power quality Input and Output Current and Power Monitor overall power capacity Balance loads across phases Remote Metering Outlet Level Monitor current draw against breaker capacity

Power Management: Rack PDU CAPABILITIES Remote Metering Input Remote Metering Branch Circuit Remote Metering Outlet Level Remote Power Control Outlet Level ADVANTAGES Cabinet power loading Load balancing Proactive overload notification Optimize capacity usage Chargebacks Equipment power consumption visibility Ghost servers Reboot hung up equipment Scheduled start up and shutdown Outlet provisioning

Power Management: Rack PDU or RPP? Ideally at both levels Limited budget choose rack PDU level 1:1 association Rack PDU and RPP breakers Rack PDUs have branch circuit breakers too More granular complete visibility = concrete steps to reduce power consumption

Environmental Management: Why? Minimize hardware failures Reduce cooling and (hence) operational costs Safety

Environmental Management: What? PARAMETER Air Intake Temperature Top and Bottom Front of Cabinet RECOMMENDED RANGE 18 25 C / 64 80 F Air Exhaust Temperature Top Back Intake temp + 20 C / 35 F Relative Humidity 40% 60% Leak Detection Under raised floor

Electronic Access Control Why? 58% of attacks within financial services industry and 71% within healthcare are carried out by insiders IBM X Force Threat Intelligence Index Regulatory Compliance HIPAA, PCI DSS, FEMSI

Access Control Considerations Cabinet Level Logging of all access attempts user name, time stamp and how? Alerts for unlocked cabinets and open doors Biometric cards for multi factor authentication Separate system for datacenter access Provides full control to datacenter personnel Lower cost of deployment

White Space Management: Challenges High cost of networking all remotely managed equipment Lack of cohesive integration Multiple management platforms

Solutions IP Consolidation Technologies Reduce Network Costs Reduce Number of IP Addresses 90%! IP addresses can cost as high as $500/port IP consolidation technologies help significantly reduce networking costs and complexity Consider failover capability with IP consolidation

Solutions Integrated Hardware Local Power Monitoring EAC Front Environmental Monitoring EAC Rear Network Management

Solutions Preconfigured Cabinet Saves deployment time and costs Seamlessly integrated Tested as a complete system Saves packaging

Integrated software power management, environmental monitoring and access control 24/7 data center health monitoring Historical trend reports Data and event logging Solutions DCIM

DCIM Considerations Scalability Vendor agnostic Exportable database Integration capabilities

Summary Remote management of white space will become more critical Elements to be managed include power, environmental and access control Integrated hardware and software solutions minimize management challenges