Leveraging DCIM to Increase Energy Efficiency and Savings
|
|
- Janice Evans
- 5 years ago
- Views:
Transcription
1 August 6, 2013 Leveraging DCIM to Increase Energy Efficiency and Savings Siemens AG 2013 All rights reserved. usa.siemens.com/datacenters
2 Contents Challenges of Today s Data Centers Turning Challenges into Opportunities with DCIM DCIM elements for Optimized Efficiencies and Green IT Summary and Q&A Siemens AG 2013 All rights reserved. Page 2
3 Challenges in Today s Data Centers Critical operations relying on data center Average downtime cost $300,000/hour Data centers use 10 to 30 times more energy per Sqft. than office space Silo ed systems: IT and Facility organizations often misaligned Nearly 25% of companies will run out of capacity in at least one of their sites this calendar year Increasing Publicity and Stringent Government Regulations Source: 1) The State of Data Center Evolution, April 2013, UBM Tech and InformationWeek Marketing Services 2) Research Roundup for Data Center Infrastructure Management Tools, March 2013, Gartner, Inc. 3) Uptime Institute 2013 Data Center Survey, April ) Siemens internal estimate based on market research Siemens AG 2013 All rights reserved. Page 3
4 What is Datacenter Infrastructure Management (DCIM)? 2013 Gartner, Inc. and/or its affiliates. All rights reserved. Gartner is a registered trademark of Gartner, Inc. or its affiliates. For more information, info@gartner.com or visit gartner.com. Used with permission. Data center infrastructure management (DCIM) software tools monitor, measure, manage and/or control data center performance, utilization and energy consumption Ideally, DCIM provides this functionality for all IT-related equipment (such as servers, storage and network switches) and infrastructure components (such as PDUs and CRACs). Cs) DCIM enables IT professionals to understand energy consumption from a holistic data center perspective DCIM tools integrate facets of system management with building management and energy management, with a focus on IT assets and the physical infrastructure needed to support them Source: Courtesy of Gartner Siemens AG 2013 All rights reserved. Page 4
5 Opportunities with Datacenter Infrastructure Management (DCIM) Siemens AG 2013 All rights reserved. Page 5
6 Facility Infrastructure and Management Physical Overview PDU / RPP integration Siemens AG 2013 All rights reserved. Page 6
7 An Example of Facility Field Technology for Power Distribution Busway Power Busway Server Busway PDU / RPP integration Compared with cable and conduit 15-40% lower cost 50% less space Capability to transmit power quality and usage to EPMS/BMS/DCIM Siemens AG 2013 All rights reserved. Page 7
8 Power Metering and Monitoring Solutions for the Data Centers MV Metering Relays & transient Power Meters MV Metering Relays & transient Power Meters LV Switchgear / Switchboard Power Meters and communicating trip units LV Switchgear / Switchboard Power Meters and communicating trip units LV Branch Circuit Embedded Metering PDU / RPP integration LV Branch Circuit Embedded Metering Siemens AG 2013 All rights reserved. Page 8
9 DCIM Bridging the Gap between IT and Facility Management Siemens AG 2013 All rights reserved. Page 9
10 DCIM Backbone of Integration Collect Information Network Fire/Life Safety Firewall Security & Access Consolidate Information VOIP Rack Cooling Power Distribution DCIM Storage Water HD Visualization Server Metering What-If Analysis Web Application Lighting Siemens AG 2013 All rights reserved. Page 10
11 Functional Overview & Key Features High definition asset visualization and analytics Collaboration and process management Real-time monitoring, alarm and event notification DCIM Computational Fluid Dynamics (CFD) Key performance indicator dashboard Infrastructure life cycle management Open interface and protocol support Siemens AG 2013 All rights reserved. Page 11
12 Visual Analytics for Asset Management, Monitoring, Alarm and Event Notification 4D Dashboards Import / export of model information in universal format (Spreadsheet, html, etc.) Rack / server visual reporting Cooling, power, physical U-space Real-time monitoring in 4D Cost, client, license expiry, age, etc. Intelligent attributes / tags Our brain can digest far more information when spatially distributed in 3D 4D Dashboard Spreadsheet-based information is difficult to digest Siemens AG 2013 All rights reserved. Page 12
13 Visual Analytics for Asset Management, Monitoring, Alarm and Event Notification Siemens AG 2013 All rights reserved. Page 13
14 Case Study Eindhoven, Netherlands Monitoring = Energy Savings Power chart showing real energy savings In one of the data centers Atos saw that the cooling fans were working too hard. After analysis, Atos found that the layout of the tiles was suboptimal. Without the trigger from the DCIM data, Atos would not have been able to see this. Due to DCIM Atos could rectify the error and check the effect of changing the tiles. Effect: 9% energy savings after 2 weeks = Benefit: energy savings of 50 kw/yr Siemens AG 2013 All rights reserved. Page 14
15 Case Study Eindhoven, Netherlands Meaningful Report = Longevity of Equipments + Energy Savings Cooling report on 3 different cooling machines Cooling facilities need to balance their load because they have to be changed together. In this benchmark report you can see that they were not balanced. This means that one cooling machine had to work harder while the others were more relaxed. Identifying this imbalance and correcting it therefore had a positive impact on improving the life expectancy of all cooling machines. Balancing of the load for different cooling facilities could mean: A longer life expectancy of all cooling facilities. Significant energy savings. Siemens AG 2013 All rights reserved. Page 15
16 One Way to Predict and Prevent is to Simulate A look at the datacenter supply chain Extensive CFD simulation Designed by Best practice concepts and detailed design best practice and organic growth and some CFD High ROI if done right: Lifecycle- Enabled CFD with Datacenter Clarity LC is key to the solution Virtual model of a datacenter 10W 140W+ 350W 1280W+ 4kW 30kW+ 150kW 25MW+ Predictive Energy Efficiency Siemens AG 2013 All rights reserved. Page 16
17 CFD & Energy Efficiency Recommendations Initial set point temperature = 68 F (20 C) Final set point temperature = 75 F (24 C) Max air temperature = 100 F (38 C) ) 12% energy savings Case study Temperature Uniformity = Higher Efficiency = Saving $$$$$ Cutting plane raised 1,500 mm from the room bottom Siemens AG 2013 All rights reserved. Page 17
18 Considerations for DCIM Gradual Deployment Establishing an accurate asset inventory Developing an accurate baseline using current state and utilization Monitor and alarm in real-time using previous asset behavior knowledge Data is often: Know what, when and how Know what and when to alarm, Decentralized long to monitor and whom should act on Incomplete Know what is the ideal warnings or alarms probing frequency Move from reactive Inaccurate Leverage Integration Expertise state of affairs to prevention Leverage your stakeholders! from the DCIM vendor and control Manage the baseline! STEP 1 STEP 2 STEP 3 Siemens AG 2013 All rights reserved. Page 18
19 Summary Technologies advances in areas such as physical infrastructure and IT stacks are improving efficiencies at the field level DCIM Reaching new levels in data center efficiencies Bridging gaps of IT and Facility Management Smarter Decisions Optimized Efficiencies Green IT Siemens AG 2013 All rights reserved. Page 19
Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime
July 17, 2013 Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime siemens.com/answers Predictive Resilience Table of content What is DCIM & Its Business Value Extract Maximum
More informationIT Transformation Through ESPCs
June 27, 2013 IT Transformation Through ESPCs Restricted Siemens AG 2013. All rights reserved. siemens.com/answers Contents Integration of IT with Facilities ESPCs as Related to Data Centers Measurement
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 2 Implementation Challenges & Strategic Advantages - Predictive Analysis August 8, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Implementation
More informationDCIM Solutions to improve planning and reduce operational cost across IT & Facilities
DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions
More informationData Center Infrastructure Management (DCIM) Demystified
software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center
More informationsiemens.com/dcim We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.
Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 Tel: (847) 215-1000 Fax: (847) 215-1093 Subject to changes and errors. The information given in this
More informationData Center Lifecycle and Energy Efficiency
Data Center Lifecycle and Energy Efficiency Lifecycle infrastructure management, power management, thermal management, and simulation solutions enable data center modernization. White Paper October 2014
More informationSystem architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,
Datacenter Clarity LC Tech sheet Overview As part of the Integrated Data Center Management Suite (IDCMS), Datacenter Clarity LC * provides tools for operating and optimizing data centers. This includes:
More informationData Center Infrastructure Management (DCIM) By Jesse Zhuo
Data Center Infrastructure Management (DCIM) By Jesse Zhuo Agenda The Evolution of DCIM Users Perspectives Management Methodology by Delta DCIM The Evolution of DCIM What is DCIM DCIM is software for Data
More informationSystem architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,
Datacenter Clarity LC Tech sheet Overview Datacenter Clarity LC * is part of the Siemens BT Integrated Datacenter Management Suite (IDCMS). Clarity LC provides tools for operating and optimizing data centers,
More informationPOWER AND THERMAL MANAGEMENT SOLUTIONS
POWER AND THERMAL MANAGEMENT SOLUTIONS Power has long been a critical public utility we depend on in our homes and daily lives. Companies are under pressure to provide the necessary hardware and software
More informationPower IQ for econnect
1 Center Energy, Power, Environmental, and Access Control Monitoring Software In today s data center, being efficient with power and cooling resources is just as important as maintaining uptime. Power
More informationPLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy
PLAYBOOK F O R C H A N G E How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy The world is becoming more digital every day. The demand for feature-rich,
More informationRemote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products
Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products Learning Outcomes Need for Remote Management of Whitespace Understand Elements
More informationData Center Infrastructure Management (D.C.I.M.)
Data Center Infrastructure Management (D.C.I.M.) Garies Chong, RCDD, DCDC. BICSI Southeast Asia District Chair Managing Director of EMS Wiring Systems Pte Ltd Data Center Infrastructure Management (D.C.I.M.)
More informationCatch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable
Catch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable Urs Iten, Director Global Portfolio Management Data Center siemens.com/datacenters
More informationTotal Building Solutions for Data Centers. The next generation of intelligence. usa.siemens.com/datacenters
Total Building Solutions for Data Centers The next generation of intelligence usa.siemens.com/datacenters Executive Summary Data center managers need to be able to leverage information to make their operations
More informationDelivering Next Generation DCIM for a Mobile Workforce
Delivering Next Generation DCIM for a Mobile Workforce 1 About Optimum Path Optimum Path Inc. is a software company, headquartered in Florida, USA with locations in APAC and EMEA regions. We continue to
More informationCA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management
PRODUCT SHEET: CA ecometer CA ecometer Improve data center uptime and availability through better energy management agility made possible CA ecometer helps you to visualize, monitor, and better manage
More informationComprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
More informationFeatures and Benefits: Power IQ DCIM Monitoring Solutions
1 : Power IQ DCIM Monitoring Solutions Vendor-agnostic Management Energy Efficiency Through one web browser, monitor any device from major manufactures such as APC, Avocent, BayTech, Chatsworth, Cyber
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational
More information1.0 Executive Summary. 2.0 Available Features & Benefits
Statement Of Work Energy Management Services Table of Contents 1.0 Executive Summary 2.0 Available Features & Benefits 3.0 Assessment Deliverables Selection 4.0 On Site Assessment Activities 5.0 Exclusions
More informationData Centre Solutions Expertly Engineered APC Management Software
Data Centre Solutions Expertly Engineered APC Management Software Data Centre Solutions Expertly Engineered A vendor neutral software suite, which provides a unified view and analysis of complex IT physical
More informationTwo-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center
Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center Adapting to Change Concern over the pace of technology change is increasing among data center managers. This was reflected
More informationOptimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.
Optimize Your Data Center Gary Hill VP, Business Development DVL Group, Inc. Data Center Age Profile Gartner Group Survey Legacy Data Centers Challenges Under Powered - Room or Racks Inadequate Air Delivery
More information1.0 Executive Summary
Statement of Work - 1 - Power and Cooling Assessment for Data Center Professional Services Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service
More informationMeasurement and Management Technologies (MMT)
IBM Systems Lab Services and Training Measurement and Management Technologies (MMT) Data Center Solutions for a Smarter Planet AGENDA IBM Energy Efficiency Program & Accomplishments IBM CO2 Reduction Commitment
More informationRegional Seminar Series Orlando. Critical Facilities Update
Regional Seminar Series Orlando Critical Facilities Update November 4, 2009 Robert Wheatley, OSIsoft Alexis Stobbe, OSIsoft Empowering Business in Real Time. Copyright 2009, OSIsoft, LLC. All rights Reserved.
More informationDCIM Software and IT Service Management - Perfect Together
DCIM Software and IT Service Management - Perfect Together A White Paper from Raritan 2015 Raritan Inc Overview Information Technology is so fundamental to every business today that every organization
More informationAPPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS
APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS Table of Contents Executive Summary 3 The Colocation Market 4 An Introduction to DCIM 5 The Value of DCIM for Colocation Providers
More informationDCIM Data Center Infrastructure Management Measurement is the first step
DCIM Data Center Infrastructure Management Measurement is the first step Presented by Julius Neudorfer Sponsored by DCIM Data Center Infrastructure Management Measurement is the first step Presented by
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More informationChanging the way companies run their data centers
Infrastructure Management & Monitoring for Business-Critical Continuity TM Changing the way companies run their data centers The Aperture TM Suite Optimize performance of your data center without COmpromising
More information:: While reducing energy costs remains a factor, the most commonly reported driver of DCIM investment plans is capacity planning -Gartner*
According to a recent Uptime Institute DCIM User Survey, :: While reducing energy costs remains a factor, the most commonly reported driver of DCIM investment plans is capacity planning -Gartner* Most
More informationManage power your way
Converged and hyperconverged infrastructure solutions Manage power your way Intelligent power management for converged and hyperconverged infrastructure solutions eaton.eu/converged Unite converged and
More informationCRITICAL INFRASTRUCTURE ASSESSMENTS
CRITICAL INFRASTRUCTURE ASSESSMENTS CRITICAL INFRASTRUCTURE ASSESSMENTS Critical Infrastructure Assessments Professional insight delivered by Vertiv experts will ensure that your infrastructure performs
More informationHow vxchnge Centralized its Operations with the PI System and Datacenter Clarity LC
How vxchnge Centralized its Operations with the PI System and Datacenter Clarity LC Foad Amoon, vxchnge, Director of Systems Management Patrick Lepage, Maya HTT, Senior Application Engineer Conference
More informationARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management
ARTO LIND ABB Ability Datacenter Automation The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management Data Center common functionality DCIM needs to be open to handle
More informationMove beyond the expected.
Infrastructure Management & Monitoring for Business-Critical Continuity TM Move beyond the expected. The Avocent Data Center Planner Taking data center operations to the next level Execution Availability
More informationData Center Infrastructure Management ( DCiM )
Page 1 Data Center Infrastructure Management ( DCiM ) DCiM is defined by technology researchers and analysts as the integration of information technology (IT) and facility management disciplines to centralize
More informationCreate a sustainable, high-performance university campus.
Create a sustainable, high-performance university campus. Discover how to maximize efficiency, safety, and productivity with an integrated university infrastructure. Make the most of your energy SM Today
More informationUsing CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer
Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer Agenda What is CFD? Applications of CFD Applicability to the Data Center How it
More informationRAMP DCIM Data Center Infrastructure Management Software
RAMP DCIM Data Center Infrastructure Management Software RFP TEMPLATE 1-866-612-3637 SALES@TUANGRU.COM TUANGRU.COM DCIM RFP TEMPLATE Dear Sir or Madam, Your company has been invited to submit your company
More informationBuilding a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available
White Paper Markets Served Data center & IT By Arthur Mulligan Product Line Manager, Eaton U.S. Power Quality Jim Tessier Product Manager, Eaton IT Hardware and Software Building a power monitoring and
More informationsurvey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.
:: In a recent Uptime Institute survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1. 2 Maintain Assess Control ROI Monitor Optimize The Need for a Better Approach
More informationSmart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA
Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center
More informationSALAMANDER. Automated Infrastructure Management
SALAMANDER Automated Infrastructure Management INNOVATION STARTS HERE Facemate is a market leader, providing customers with Data Center Solutions, Networking and Datacenter cabinets, DC Management Software,
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More informationFeatures and Benefits: dctrack DCIM Operations Solution
1 : Asset Auto Discovery Allows for automatic recognition integration into dctrack asset management system for a newly added asset. Automatic recognition of make model of asset makes adding or changing
More information<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model
Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and
More informationSchneider Electric Data Center Software
Schneider Electric Data Center Software StruxureWare Operations 7.0 Software Platform End to end Data Center Infrastructure Management (DCIM) software for monitoring, control of power, cooling, security
More informationOvercoming the Challenges of Server Virtualisation
Overcoming the Challenges of Server Virtualisation Maximise the benefits by optimising power & cooling in the server room Server rooms are unknowingly missing a great portion of their benefit entitlement
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationGreen IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More informationThe 4th Industrial Revolution and Data Center Power Intelligent data needs intelligent power
DUBLIN, NOVEMBER 2017, ARTO LIND, SALES MANAGER, ABB INDUSTRIAL AUTOMATION The 4th Industrial Revolution and Data Center Power Intelligent data needs intelligent power White paper summary This paper will
More informationPrefabricated Data Center Solutions: Coming of Age
Prefabricated Data Center Solutions: Coming of Age Steven Carlini - Global Data Center Marketing Director April 2014 Schneider Electric 1 Schneider Electric 2 Your ability to compete relies on the design,
More informationThe Evolving Data Center
The Evolving Data Center Dominic Loh Product Manager, Power Quality, APAC Data Centers are enabling global growth Proliferation of mobile computing Digitalization of everything Big Data 2 Evolution of
More informationIt s practically a cliché, but
THE STATE OF DATA CENTER EVOLUTION By Andrew Mazer It s practically a cliché, but that s because it s true: An organization s data is one of its most valuable assets. Today, robust analytics tools enable
More information5 STEPS for Turning Data into Actionable Insights
5 STEPS for Turning Data into Actionable Insights Today, nearly every piece of equipment in a data center has at least one sensor attached to it. In fact, American Society of Heating, Refrigerating and
More informationAPMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications
APM UPS 18kW - 90kW The Flexpower Technology for mission critical applications WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable
More informationInternational 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase
International 6SigmaDC User Conference CFD Modeling for Lab Energy Savings DCSTG Lab Temperature Setpoint Increase Chris Noland cnoland@cisco.com Vipha Kanakakorn vkanakak@cisco.com 3/4/2010 Goal & Limitations
More informationData Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Assessment Helps Keep Critical Equipment Operational A White Paper from the Experts in Business-Critical Continuity TM Executive Summary The IT infrastructure within many companies has evolved
More informationData Center Efficiency and Retrofit Best Practices
White Paper August 2014 IT@Intel Data Center Efficiency and Retrofit Best Practices The use of best practices enables us to increase data center efficiency and capacity, optimize the return on invested
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationTotal Modular Data Centre Solutions
Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system
More informationThe State of Data Center Health Management Strategy 2017
Strategic Alliance Partner Health Management Strategy The State of Data Center Health Management Strategy 2017 Fall 2017 Introduction Data has become one of the most valuable assets for 21st century businesses.
More informationEnsuring a Successful DCIM Project. What You Need to Know. Paul Goodison CEO, Cormant Inc.
Ensuring a Successful DCIM Project. What You Need to Know. Paul Goodison CEO, Cormant Inc. Cormant DCIM and Interop Cormant DCIM Company Founded 2001 Delivering Infrastructure Management Solutions since
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationSystems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development
Systems and Technology Group IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development Power and cooling are complex issues There is no single fix. IBM is working
More informationEasy Networking for Power Monitoring. network based MONITORING SOLUTIONS
Easy Networking for Power Monitoring network based MONITORING SOLUTIONS Monitoring Real-Time Power Information with Internet Explorer The ability to network an electrical distribution system is an overlooked
More informationElectrical solutions for buildings. Energizing tomorrow s buildings, today
Electrical solutions for buildings Energizing tomorrow s buildings, today At Eaton, we help meet the challenging power demands of modern commercial buildings. Eaton is a leading power management company,
More informationEmerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is
More informationAn Optimized Infrastructure In a Virtualised World. Bassel Al Halabi Regional Manager Middle East & Pakistan Panduit International Corporation
An Optimized Infrastructure In a Virtualised World Bassel Al Halabi Regional Manager Middle East & Pakistan Panduit International Corporation Overview IT is rapidly transforming how businesses, consumers
More informationAPC APPLICATION NOTE #74
#74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.
More information1008 kw, Tier 2, Chilled Water, ft 2
[eference Design 81] 1008 kw, Tier 2, hilled Water, 18115 ft 2 DESIGN OVEVIEW Data enter IT apacity 1008 kw Adaptable from 200 kw to 3024 kw Target Availability Tier 2 Annualized PUE at 100% Load 1.65
More informationMeasurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities
Information and Communication Technology Portfolio Review San Francisco, CA March 2011 Project Name: Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication
More informationKako optimizovati operativni rad data
Sanja Milovanović, ENEL PS Dani tehnološkog umeća DATUM Beograd, 2017 Kako optimizovati operativni rad data Data Center Infrastructure Management DCIM centra 1 Data Center Management: Good Questions DC
More informationCHANGING THE WAY COMPANIES RUN. The Aperture Suite
CHANGING THE WAY COMPANIES RUN THEIR DATA CENTERS The Aperture Suite 1 OPTIMIZE PERFORMANCE OF YOUR DATA CENTER WITHOUT COMPROMISING AVAILABILITY Reduce your costs 20% and maintain five-nines uptime. Sound
More informationEngineering and Manufacturing Excellence in Data Centre Infrastructure
Engineering and Manufacturing Excellence in Data Centre Infrastructure Since 1982 Australia s Largest PDU Manufacturer NetSense DCIM Software Intelligent Power PDU s SafetyNet Series 5 CREMS E-Rack 19
More informationAvoid a DCIM Procurement Disaster
Avoid a DCIM Procurement Disaster Matt Stansberry Senior Director, Uptime Institute 7 December 2016 2016 Uptime Institute, LLC Many organizations struggle with DCIM decisions Process takes too long, software
More informationAdvanced Monitoring Solutions for Critical Electric Power Transmission & Distribution Assets
Advanced Monitoring Solutions for Critical Electric Power Transmission & Distribution Assets www.intellisaw.com The Case for Critical Asset* Monitoring The vast majority of critical assets in the field
More informationEnergy efficiency within data centers Is your IT organization capitalizing on the latest technology options and best practices?
This is a photographic template your photograph should fit precisely within this rectangle. Energy efficiency within data centers Is your IT organization capitalizing on the latest technology options and
More informationCIO Forum Maximize the value of IT in today s economy
CIO Forum Maximize the value of IT in today s economy Laura Scott, Vice President Service Product Line Sales Global Technology Services IT infrastructure is reaching a breaking point. 85% idle In distributed
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationCurrent Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc
Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient
More informationHow do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.
If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot
More informationControlling DC Data Exhaust
Controlling DC Data Exhaust 3-D Visualization and Integration of Data Center Monitoring Systems Utilizing the PI System and PI AF 2011 March Gregor Vilkner, Skanska Patrik Johansson, Infozone 1 This isn
More informationEnergy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director
Energy Logic: A Roadmap for Reducing Energy Consumption in the Data Center Emerson Network Power Ross Hammond Managing Director Agenda Energy efficiency Where We Are Today What Data Center Managers Are
More informationIXcellerate Moscow One Datacentre - Phase 1 & 2 Overview
Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering
More informationICT Infrastructure Solutions. Real power for virtualisation
ICT Infrastructure Solutions Real power for virtualisation Why Eaton? When it comes to the power infrastructure for virtual environments, Eaton is a pioneer. We offer a number of significant advantages.
More informationSustainable Business with Green Datacenter
Site and Facilities Services Data Center Services Sustainable Business with Green Datacenter Prag, May 11th, 2010 Stephan Bhend, IBM Site and Facilities Services 2008 IBM Corporation Sustainable Business
More informationHigh Availability & Security for Data Center
High Availability & Security for Data Center Pressures from new IT technology Keeping up with complex system changes Staying in control of capacity, energy, and availability All content in this presentation
More informationThe Value of Force.com as a GRC Platform
The Value of Force.com as a GRC Platform Andy Evans - Xactium Limited March 2009 Executive Summary The importance of governance, risk and compliance (GRC) activities to organizations has become increasingly
More informationMEETING THE DCOI FEDERAL MANDATE. Achieving Rapid Compliance with the Trellis Platform
MEETING THE DCOI FEDERAL MANDATE Achieving Rapid Compliance with the Trellis Platform TWO STAGE POWER DISTRIBUTION Executive Summary The Business Issue The US federal government mandates DCIM and a PUE
More informationThe Most Comprehensive DCIM Solution
The Most Comprehensive DCIM Solution NetZoomDC TM is the complete, enterprise Data Center Infrastructure Management (DCIM) software which Models, Manages, Monitors and Maximizes data center assets, space,
More informationDCIM and how it helps deliver the InteropNet. Paul Goodison CEO, Cormant Inc CORMANT
DCIM and how it helps deliver the InteropNet Paul Goodison CEO, Cormant Inc. 1 855 CORMANT pgoodiso@cormant.com Agenda The Current Data Center Management Paradigm What is DCIM? DCIM Adoption in an Enterprise
More informationJack van der Horst, Regional Technology Manager, Asia Pacific. ABB
ABB DATA CENTER FORUM 2017, 11 JULY 2017, TUESDAY ABB Ability Data Center Automation Datacenter Automation for improved operations and reduced risks Jack van der Horst, Regional Technology Manager, Asia
More informationGoogle s Green Data Centers: Network POP Case Study
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More informationToday s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins
Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins Today's Moderator Ed Sulivan Editor Today's Presenter Steve Maling Director, US Field Services Marketing, Schneider