Assembly Instructions scancontrol 2700/2750 (500)

Similar documents
The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

Instruction Manual scancontrol 27x0

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Instruction Manual scancontrol 2700 / 2710 LLT LLT LLT LLT LLT LLT

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Instruction Manual scancontrol 29xx

Quick Manual DT6220 DT6222 DT6230

More Precision. optoncdt // Laser Triangulation Displacement Sensors

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. optoncdt // Laser displacement sensors (triangulation)

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Instruction Manual DS05(03) DS05(04) DS05(07) DS05(14) DS05(15) DS1 DS1(04) DS1/T

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

More Precision. colorsensor // Color Sensors, LED Analyzers

Instruction Manual reflectcontrol Compact RCC RCC RCC RCC RCC RCC

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

More Precision. 2D/3D laser scanner (laser profile sensors)

PHOENIX CONTACT - 10/2009

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Laser Triangulation Displacement Sensors

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. optoncdt // Laser displacement sensors (triangulation)

Access Terminal IF-800

Laser Triangulation Displacement Sensors

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Reference Guide METTLER TOLEDO WMH Weighing Platforms

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. colorsensor // Colour Sensors, LED Analyzers

More Precision. scancontrol BL // 2D/3D blue laser scanner

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

FL MC 2000E (SM40) LC

F1000 User's Manual. (Version: V1.01)

Type ME43. Quickstart

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Laser Triangulation Displacement Sensors

AX3000 Platine Terminal Ethernet TCP/IP

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Measurement range, typical

LVX Control Unit. Features:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Instruction Manual scancontrol 29xx/BL

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

FSM-510G Series Ethernet Management Switch Quick Start Guide

AX3000 Platine Terminal Ethernet TCP/IP

Instruction Manual Cooling Jacket Advanced. Cooling Jacket Advanced Cooling Jacket Advanced Extended

IF-80x Outdoor Terminal

More Precision. optoncdt // Laser displacement sensors (triangulation)

Flow Sensor SONOFLOW CO.55

Fieldbus Gateway Type ME43

MC 11 EB-2 Power supply cabinet with external bus, AC version

More Precision. colorsensor // Colour Sensors, LED Analyzers

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

3/4 U CPCI Serial Case System

More Precision. optocontrol // Optical precision micrometers

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

More Precision. colorsensor // Color sensors, LED Analyzers

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w

IMC-21 Quick Installation Guide

User Manual. Printer P-52RUE

Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

Fiber optic converter audio and CAN TA OPERATION MANUAL

CMC III Universal Sensor

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

3+1 U CPCI Serial System

Inclinometer. 4-20mA and RS232

M2-iLAN-2 Laser Scanner

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Contents. Part no.: MLC500T Safety light curtain transmitter

Accessories and options

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

More Precision. optoncdt // Laser displacement sensors (triangulation)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating Instructions 10/200 10/400 25/200 25/400

CPCI-PS24 24V-Power Supply

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

eddyncdt 3060 eddyncdt 3061

Operating Instructions

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

38 MHz Passive Voltage Probe R&S RT-ZP1X

Transcription:

Assembly Instructions scancontrol 2700/2750 (500) 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply must not exceed the specified limits. > > Danger of injury, damage or destruction of the sensor Avoid shock and vibration to the sensor. Avoid continuous exposure to dust and spray on the sensor. Avoid exposure to aggressive materials (e. g. washing agent, penetrating liquids or similar) on the sensor. > > Damage to or destruction of the sensor Read the detailed instruction manual before operating the sensor. You will find this manual on the provided CD or online at www.micro-epsilon.com. 2. Notes on CE Marking The following applies to the scancontrol 27xx: EU directive 2014/30/EU EU directive 2011/65/EU, RoHS category 9 The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed. 3. Proper Environment Protection class: IP 65 (Only applies to connected output plugs or protective caps) Operating temperature: 0 to +50 C (+32 to +122 F), by free circulation of air Storage temperature: -20 to +70 C ( -4 to +158 F) Humidity: 5-95 % (non condensing) Vibration: DIN EN 600068-2-6 (sine shaped) Mechanical shock: DIN EN 60068-2-29 4. Scope of Delivery of scancontrol 27xx 1 Sensor scancontrol 27xx with integrated controller 1 power supply cable PC2700-4,5, length 4,5 m; ODU round connector and free cable ends 1 scancontrol Software CD with programs and documentation 1 Sensor inspection log / assembly instructions 1 Bag of accessories with one ODU male connector 6-pin (RS 422) and two protective caps for ODU female connector (6- or 8-pin)

5. Laser Safety The scancontrol 27xx sensors operate with a semiconductor laser having a wavelength of 660 nm (visible/red). The laser operation is indicated visually by the LED on the sensor. scancontrol 27xx sensors with a maximum laser power up to 10 mw are classified in Laser Class 2M (IIM). The following information labels are fitted to the sensor housing (front and rear side). If both information labels are hidden in the installed state, the user must ensure that additional labels are fitted at the point of installation. IEC 60825-1: 2015-07 P 10 mw; E 65 W/m²; =660 nm Hazard to the eye via laser radiation! Consciously close your eyes or turn away if the laser radiation impinges on the eye. Lasers of Class 2M are not subject to notification and a laser protection officer is not required. Mark the laser area recognizable and everlasting. Laser Class 3B scancontrol 27xx sensors with a maximum laser power up to 20 mw are classified in Laser Class 3B (IIIB). When using lasers of 3B class appropriate protective glasses are necessarily! Injury of the eyes and the skin by laser radiation! Class 3B (IIIB) laser sensors are notifiable and a laser protection officer is required either. During operation the laser area has to be restricted and marked. The following information label should be fitted to the sensor housing (front and rear side): Warning - Laser radiation Avoid exposure to beam Class 3B Laser Product IEC 60825-1: 2015-07 P 50 mw; =660 nm i Beam attenuator The beam attenuator prevents access to all laser and collateral radiation. The figures show the sensor with closed and open beam attenuator. The beam attenuator must be open during measurement. Sensors of Laser Class 3B (IIIB) need an external key switch to switch off the laser, see Chap. Laser switching.

6. Connections, LED Displays laser on state 1394/Ethernet 1394/ Ethernet 24 VDC RS 422 RS 422 24 VDC LLT27xx, top side LLT27xx (501), rear side The sensors are available in two versions: Sockets on the top side or on the rear side. LED displays LED laser on Green: Laser on Note: The status LED flashes green; long during LED state : Green: Measurement active data transmission Two-color LED Green flashing: Data transmission and short for controller (red / green) Red flashing: Error code accesses. The state LED indicates different error conditions by flashing. If no flashing occurs for several seconds, no error has occurred. Power supply (Power) Pin no. Belegung Steckverbinder 24 VDC Standard Adernfarbe PC2700; alte Ausführung in ( ) Options 502, 503, 504, 505 Color PC2700(002) 1 24V+ white (rot) 24V+ pink Range: 11 V 30 V (Rated value 24 V) DC; maximum current 500 ma 2 n.c. n.c. LH+ gray n.c. 3 n.c. n.c. Laser off+ yellow 4 n.c. n.c. Laser off- green n.c. 5 n.c. n.c. LH- brown 6 24V GND brown (black or blue) 24V GND white 1 6 2 5 3 4 View on solder pin side, male cable connector, counting direction anticlockwise

External laser switching Series LLT27xx (502), LLT27xx (503), LLT27xx (504) and LLT27xx (505) sensors offer this function. i Sensors of Laser Class 3B (IIIB) need an external key switch to switch off the laser. Use a serial key switch inside the control circuit to switch off the laser. You will find details for the wiring in the instruction manual, Chap. 5.2.4. RS422, Synchronization Pin no. Assignment connector RS422 RS422 General 9-pin Sub-D 1 1 RX1 CH1 2 2 /RX1 /CH1 3 5 GND1 5 3 TX2 CH2 9 4 /TX2 /CH2 1 6 GND2 5 1 6 2 5 3 4 View on solder pin side, male cable connector The pin numbers refer to the scancon- TROL 27xx sensor. Micro-Epsilon recommends the use of the interface cable SC2700-4.5 RS422 from the optional accessories. The RS422 port can be used with either of the following configurations: RS422: Loading of programs and transmitting of measurement results. Synchronization/Triggering: Synchronization resp. triggering using switching signals. 1) Optional RS422 interface cable (SC2700-4,5RS422) from Micro-Epsilon, compatible to the RS422 to USB converter. All outputs or inputs are designed symmetrically. Internal terminating resistors 120 Ohm.

Ethernet connection, standard link to the PC Pin no. RJ45 connector 8-pin. connector The pin Color stranded hook-up wire Pin no. 10BaseT, 100BaseTX 1000BaseT 1 white (orange) 5 Tx+ D1+ 2 orange 6 Tx- D1-3 white (green) 8 Rx+ D2+ 4 blue 1 D3+ 5 white (blue) 2 D3-6 green 7 Rx- D2-7 white (brown) 3 D4+ 8 brown 4 D4- View: pin side male cable connector 1 1 7 6 32 8 4 5 View on solder pin side, ODU numbers refer to the scancon- TROL 27xx unit. Micro-Epsilon recommends using the Ethernet connection cable SC2700-5/ ET from the recommended accessories. The sensors are supported by an automatically, sensor adapted IP address in the link-local-net (169.254.x.x). There is no collision testing effected. This is the standard setting. The sensor supports the DHCP protocol. This setting is activated by default and has priority over the retrieval in the link-local-net. A fixed IP address can be used. Use the Ethernet Configurator software provided on the CD in order to make the sensor settings described above. 7. System Requirements scancontrol Configuration Tools The following minimum system requirements are necessary: Windows 7 (32 bit and 64 bit), Windows 8 or 8.1 (32 bit and 64 bit), Windows 10 (32 bit and 64 bit) 1-GHz processor (32 bit and 64 bit) or faster / 1 GB RAM Screen resolution: 1024 x 768

8. Quick Start: Commissioning, Software Install the software. Please insert the scancontrol Software CD in the CD-ROM device. Follow the dialog through the installation process. A. Reading of installation help B. Installation of software C. Further informations in the online documentation Mount the sensor according to the installation instructions. Connect the sensor to the PC via the Ethernet cable. Connect the sensor to display or monitoring units. Connect the sensor to the power supply. The connectors for the operating voltage, switching signals and Ethernet are fitted with push-pull locking. i Pull apart at the grip to release the connection. Connect the shield of the power supply cable to the PE protective earth conductor of the main power supply. Close unused connection plugs with the provided protective caps. Switch on the power supply (24 VDC). Only connect the sensor to the peripheral equipment, if it is disconnected from the power supply, i.e. only when the operating voltage is switched off. The sensor needs a warm-up time of typically 20 minutes for high precision measurements. Please wait until the scancontrol device is recognized by the PC. This may take a few seconds. Now you can operate the scancontrol measurement system with the scancon- TROL software packages. i No driver is required for scancontrol devices with an Ethernet interface.

9. First Profile Now start the scancontrol Configuration Tools software. Click on Display Profiles in the main window. If the software shows the error message No scancontrol found in the status line, please check the Ethernet connection between scancontrol and PC. On the left side you can adjust the settings for your measurement task, the right side shows the profile data and information about the measurement. 10. How to Access Profile Data Profile data of scancontrol can be accessed via: GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration (C, C++, C# and others) For details how to access profile data refer to the enclosed online manual.

11. Further Information Please refer to the enclosed online manual the section Status and Error Messages and Notes in the scancontrol Configuration Tools manual. You will find details to the separate programs in the respective instruction manuals or in the instruction manual of this sensor, Chap. 6.2. You will find the instruction manuals online or on the provided CD. www.micro-epsilon.com MICRO-EPSILON Messtechnik GmbH & Co. KG Königbacher Str. 15 94496 Ortenburg / Germany, Tel. +49 (0) 85 42/1 68-0 *X9771182.500-B01* X9771182.500-B011127HDR