Leica RX1250 & TPS 1200 Robot

Similar documents
TDS Nomad Connect To Bluetooth Instrument. Tested with Trimble Nomad with integrated Bluetooth, and Sokkia 530R3 total station.

Altus APS3 Configure Rover for Radio, NTRIP or GPRS RTK Link

Sokkia GSR 2700 ISX GPRS Configuration

X PAD Construction 2.5.5

Quick Start Guide. Leica TPS TC1800 (Direct) Leica - Communication Settings (19200,8,None,1)

Perpendicular Offsets - point picker is a check-box type button and will now remain in effect until switched off.

Evidence Recorder Release Notes

Leica Viva SmartWorx Viva on TS

Contents Introduction Installation/Deinstallation of SurveyOffice Getting Started... 3

APS-3 with FieldGenius Configuration Manual

GeoMax TPS. Zipp20 Series. Installation Guide. Version: 1.0 English. Zipp20 TPS Series Installation Guide

Viva TPS. TS11/15 Total Stations Connect the CS Controller and TS15 with Bluetooth. October Summary

This document contains a list of all changes, new features, bug fixed introduced in this last version of X PAD Survey.

Use of SmartRinex for Post Processed Kinematic Surveys

FieldGenius 2005 Ver 1.2 MicroSurvey Software, Inc. 2005

Topcon GRS-1 1 Receiver Field Preparation

This firmware is protected and can only be loaded onto instruments with valid firmware (software) Maintenance date.

LEICA MobileMatriX Equipment List

APS-3 with Seismic Surveyor

Leica Viva TS11 & TS15 Hardware

GeoMax FieldGenius for Zipp20 Quick guide

SmartWorx Viva How to Record Static Observation Data On-Board GS Receivers Operating in Base Mode

Sokkia Layout v2.0 (12/15/2009) Part Number Rev. A ECO#3767. Copyright 2009 Topcon Positioning Systems, Inc. All Rights Reserved

MaCORS Quick Guide. Rover Configuration for Topcon GR 3 using Carlson SurvCE 2.x & Internal CDMA Modem

Awaken Your Inner GIS Solution. The webcast will begin at 10:01 AM (MDT)

TYPING IN ARABIC (WINDOWS 7)

Technical Note. 12 August 2009 PocketDTM Utility Surveys Brief Outline. Atlas Computers Ltd

Increase Field Survey Efficiency by Merging Technologies in NOVA MultiStation. Vincent Lui Leica Geosystems Ltd

Install UHF Radio. SF-3040 Battery Installation

Leica TPS1200 Series High performance Total Station

LEICA TCRA1103 INSTRUMENT SETTINGS

Version 2.0 English. Leica FlexLine TS02/TS06/TS09 Quick Guide

Leica TPS1200+ Series High performance Total Station

Trimble Survey Controller. Release Notes

EL-CID Quick Reference Version 6.0

MicroSurvey Software Inc. All rights reserved

High-End Surveying Precise, Fast and Intelligent. LEICA TPS1100 Professional Series

Softrock GeoMos Manual For AutoSlope Users

Leica Zeno Field for Zeno 5 Users Guide for Laser GPS Offset

FieldGenius 2010 Release Notes

Leica Viva Imaging Enrich your Surveying Workflow

Topcon Link Quick Reference Guide

Leica s Pinpoint EDM Technology with Modified Signal Processing and Novel Optomechanical Features

Table of Contents 1 PURPOSE SCOPE DEFINITIONS PROCEDURE... 5

When user select menu 2. Tables from the Main menu, the following screen will appear:

Reno A & E, 4655 Aircenter Circle, Reno, NV (775) Release Date: February 5, 2008 All Reno A&E monitors. All versions of RaeComM.

Leica TPS1200 Series High performance Total Station

Persian (Farsi) Keyboard Instructions and Specifications

Scepter / Scepter II Getting Configured for Real Time Networks with an Internet Hot Spot

Setup a VSN Survey Style Using Trimble Access (MiFi Card)

County of Sacramento Instructions for filling out an online Tree Permit

Setup a VSN Survey Style Using Trimble Access (Bluetooth Phone)

NEW FEATURES. FieldGenius Release Notes May 10, 2017

Leica TS30 and TM30 Equipment List

Leica TPS800 Series Powerful, efficient, reliable and intuitive. PinPoint Technology

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60, TS13 GNSS Sensors: GS18 T

Version 3.0 English. GRX1200 Series Getting Started

Version 1.0 English. Leica TS15 Quick Guide

Changing Your Network Password

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 5 th March 2018

Help Contents. Creating a Query - Synopsis

Trimble Survey Controller. Release Notes

Instrument Interface to. Workshop Manual

IP RECEIVER. New features GDD Rx program. Models GRx8-32 or GRx8mini. Version

NAV31. User s Manual GEOMAR SOFTWARE INC. Tel: Fax:

This how to guide should be used in conjunction with the following documentation:

Version 7.1 English. Leica GPS1200+ Applications Field Manual

Leica Captivate. Software Release Notes. Field Controllers: CS20, CS35 Total Stations: TS16, TS60, MS60. Release date 7 th June 2016

How to Archive s in Outlook 2007

PE7 / PE77 Series Plasma TV Tuner Firmware Installation Instructions. Table of Contents

User Manual. August 2008 Revision 1.0. SKH300 ibutton Reader Configuration Utility

ProScript. Quick User Guide. Helpdesk Phone number:

Filename:QIM-DP-03-Enter and Save Packager Issued Reject (K) Page 1 of 19

Evidence Recorder Release Notes

DIGITAL PROCESS CONTROLLER

Leica icon Series. Licence Installation and Activation Guide. Version 1.1 English

Leica FlexLine TS09plus Full Precision at High Performance

Leica FlexLine plus. Product Presentation V4.00

Version 5.5 English. Leica GPS1200 System Field Manual

Created December 2008

How to setup the WA232E Serial WiFi adapter

Audit report and analyse overview. Audit report user guide v1.1

General GPS TPS ROB X POLE VOL RDN RPL Jobs management System settings (units, precision, parameters, etc.)

Lab - Monitor and Manage System Resources in Windows 7 and Vista

DMC-L1 Camera Lens Firmware Installation Instructions. Table of Contents

History. The Lingo. I am confused by the different models, what are the differences?

Web Accessibility Change Your Mouse Pointer Visibility Handbook

Upgrade 6081RC Firmware

Provided by Xpert Survey Equipment Click Topcon GPT-8003A for Product Info and Updated Pricing GPT-8000A/GTS-810A SERIES AUTO TRACKING TOTAL STATION

Interface to. Instrument Manual

Exporting distribution lists from Thunderbird to Outlook

Saving an Alignment on the Smart Aligner Tool

Accessibility Options for Visual Impairment. Date: November 2017

SiteMetrix Configuring RTK Corrections

User s guide December 2011

Printer Settings. Accessing Power Saver. Selecting Output Options. Phaser 5500 Laser Printer

Unit 12. Electronic Spreadsheets - Microsoft Excel. Desired Outcomes

Label Program Printing Shelf Labels

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

EM61MK2 Version 2.25

Transcription:

Leica RX1250 & TPS 1200 Robot Total Station Extended GeoCOM & Firmware Check For FieldGenius to work correctly with your Total Station, Smart Rover and RX1250, Extended GeoCOM must be enabled. This mode will usually have been turned on by your dealer. You can confirm if it is enabled on your Total Station by using the following steps: 1. From the Main Keyboard press the USER key. 2. On the User Menu, press the F3 (STAT) 3. From the Status Menu, highlight System Information then press F1 (CONT) 2012 MicroSurvey Software Inc. Page 1 of 13

4. On the System Information Menu, on the Instrument page scroll down until you see Extd GeoCOM. This must be enabled (YES) for FieldGenius to work correctly. 5. To check the firmware on the Total Station, press F6 (Page) 6. On the Firmware page you will see the firmware versions currently installed on the Total Station. Press F1 (Cont) to return back to the Main Menu. 2012 MicroSurvey Software Inc. Page 2 of 13

RX1250 Extended OWI & Firmware Check **Please Note: This check is only necessary if you also plan to work with GPS. For FieldGenius to work correctly with your Total Station, Smart Rover and RX1250, Extended GeoCOM must be enabled. This mode will usually have been turned on by your dealer. You can confirm if it is enabled on your RX1250 by using the following steps: 1. From the Windows desktop, start SmartWorxs 2. From the Main Menu press the USER key. 3. On the User Menu, press the F3 (STAT) 4. From the Status Menu, highlight System Information then press F1 (CONT) 2012 MicroSurvey Software Inc. Page 3 of 13

5. On the System Information Menu, on the Instrument page scroll down until you see Extd OWI. This must be enabled (YES) for FieldGenius to work correctly with GPS equipment. If this setting is not enabled, contact your Leica dealer. 6. To check the firmware on the Total Station, press F6 (Page) 7. On the Firmware page you will see the firmware versions currently installed on the Total Station. Press F1 (Cont) to return back to the Main Menu. 2012 MicroSurvey Software Inc. Page 4 of 13

Configure the Total Station ATR Settings The ATR mode set on the instrument should be confirmed. 1. From the Main Menu, highlight Config and press F1 (CONT) 2. On the Configuration Menu, highlight Instrument Settings., then press F1 (CONT) 3. On the Instrument Menu, highlight EDM and ATR Settings, the press F1 (CONT) 4. On the EDM & ATR Settings Menu, scroll down and check that the ATR Setting is set to Normal. Depending on the conditions you are surveying in you may need to change this from time to time to one of the other ATR modes, but for most applications leaving this set to Normal will be ok. 2012 MicroSurvey Software Inc. Page 5 of 13

5. Press F1 (CONT) to save the settings. 2012 MicroSurvey Software Inc. Page 6 of 13

Configure the Total Station Search Settings The Search mode set on the instrument should be confirmed. 1. From the Main Menu, highlight Config and press F1 (CONT) 2. On the Configuration Menu, highlight Instrument Settings., then press F1 (CONT) 3. On the Instrument Menu, highlight Automatic Prism Search, the press F1 (CONT) 4. On the Automatic Prism Search Menu, make sure After Prediction Search With is set to No Search. 2012 MicroSurvey Software Inc. Page 7 of 13

5. Press F1 (CONT) to save the settings. 2012 MicroSurvey Software Inc. Page 8 of 13

Configure the Total Station Communications Settings 1. Turn on the instrument 2. Level the instrument 3. On your instrument select menu item 5 (Configuration) 4. Select menu item 4 (Interfaces) 5. Press the down arrow to highlight GeoCOM Mode then press F4 (CTRL) 6. Make a note of the Link Number as you will need to set this in FieldGenius. Leave the instrument setup as Base 2012 MicroSurvey Software Inc. Page 9 of 13

7. Press F1 (CONT) which will take you back to the Interfaces Screen. 8. Press the down arrow to highlight GeoCOM Mode then press F3 (Edit) 9. Verify that the communication parameters match the following: 10. Press F5 (Device) 11. Use the up/down arrows to highlight RH 1200 then press F3 (Edit) 2012 MicroSurvey Software Inc. Page 10 of 13

12. Verify that the communication parameters match the following: 13. Press F1 (Store) to set the parameters and go back to the Devices screen. 14. Press F1 (Cont) to continue back to the GeoCOM Mode screen. 15. Press F1 (Cont) to continue back to the Interfaces screen. 16. Press F1 (Cont) to continue back to the Main Menu. 17. On the instrument handle, you should see a green power light. Configure the Leica RX1250 Controller Aside from installing the FieldGenius software, nothing needs to be configured on the data collector s operating system. Run FieldGenius by double-tapping on the desktop icon. If you do not see the FieldGenius icon, then turn the RX-1250 off then back on again. 2012 MicroSurvey Software Inc. Page 11 of 13

Configure FieldGenius on the RX1250 Controller Instrument Profile Create a profile for your Leica 1200, and Edit it to access the instrument settings. Model and Communication Make: Leica Model: TPS Robot (GeoCOM) Port: Radio Baud Rate: 115200 Data Bits: 8 Stop Bits: 1 Parity: None EDM Settings Enable the Set Instrument to Zero option, and enter the Prism Offsets as follows: if you are using a Leica 360 prism you would put a +23.1mm offset in FieldGenius; a Leica Circular prism offset would be 0mm in FieldGenius, a Leica mini prism would be +17.5mm in FieldGenius, and for the RL reflectorless offset leave it set to 0mm. For more information, please refer to our Leica RX-1250 & TPS 1200 Prism Offsets document. 2012 MicroSurvey Software Inc. Page 12 of 13

Tolerance Settings Specify your desired multiset tolerances, or leave the default values. Search Settings Search Mode: PS Next (CCW or CW) Enable the Auto search for prism option. Radio Settings Select Internal Radio. Set the controller to Remote mode (since the instrument is in Base mode). Set the same Link Number as specified in the instrument (see step 6 in first section). 2012 MicroSurvey Software Inc. Page 13 of 13