onlinecomponents.com

Similar documents
onlinecomponents.com

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Push-Pull and E-Stop Switches. Datasheet

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

SMART Position Sensor, 100 and 180 Arc Configurations

PRODUCT SPECIFICATION. PC Board Relays. Series.

EM-F-7G Safety Extension Module

Datasheet - SLB 200-C04-1R

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Datasheet - SRB 301LC/B-24V

Operating instructions. Switching amplifier DN0210 DN / / 2015

Ultra Slim Relays 24

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Datasheet - SRB 402EM-24V

S82S (3/7.5-W Models)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions. Standstill monitor A / / 2011

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

MICRO SWITCH Snap-in Panel Mount Basic Switches. DM DP Series. Datasheet

PSR DC/ESP4/2X1/1X2

FF-ST2 Series. Type 2 Safety Light Curtains for Industrial Machine Safeguarding

ETD-BL-1T-OFF-CC- 10S

Datasheet SRB301ST 24V (V.2)

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

PanelView Plus/VersaView CE Terminals and Display Modules

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Making Hazardous Operations Safe and Productive

Two-hand control unit

Operating instructions. Speed monitor D / / 2014

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Installation, Operation and Maintenance Instructions

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

E-STOP relays, safety gate monitors

PSR UC/ESAM4/3X1/1X2/B

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Operating instructions Safety sensor BNS About this document. Content

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Two-hand control unit

Quick Start Guide for the Limitless WLS Series Single Switch Adapter

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

Models IM-T-9A and IM-T-11A Interface Modules

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Solid State Relays with Failure Detection Function

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

E-STOP relays, safety gate monitors

Number of input channels

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

LCI User Manual mantracourt.com

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

E-STOP relays, safety gate monitors

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

DeltaV Bulk Power Supplies

Compact Coded Magnetic Safety Interlock Switch and Control Units

NJ-Series Power Supply Unit NJ-PA/PD

E-STOP relays, safety gate monitors

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Safe monitoring relays

DeltaV Bulk Power Supplies

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

PHOENIX CONTACT - 07/2006

Operating Instructions

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

SR103AM. User Information for SR103AM. Correct Use

Two-hand control unit

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

PRSU/5 Safety Interface Controller

Model 7026 (1x32) 2-wire Multiplexer

Safety Monitoring Relays

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

Electronic timer CT-ERD.12

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Transcription:

FF-RE59292 Extension Module Instructions for use (pending) (pending) IMPROPER INTALLATION Consult with U and/or European safety agencies and their requirements when designing a machine control, interface and all control elements that affect safety. trictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. PRODUCT DECRIPTION The FF-RE59292 Extension Module provides contact multiplication for emergency stop modules, safety door modules and other safety sensors with final switching device monitoring capability (FF-B, FF-L, FF-CAN, FF-P4 or Detector 3 safety light curtains). This product has two safety relays with positive-guided contacts to ensure redundancy and offers four NO contacts and one NC contact. Its slim housing of only 22,5 mm (0.89 in) width allows this safety control module to fit into most cabinets and even helps to keep the overall cabinet size small. APPROVAL CE The product, packaging and documentation of FF-R eries products carry the CE mark; the CE declaration of conformity is attached on the last page. curus This product is currently being assessed (pending) by Underwriters Laboratories Inc. according to Canadian and U.. safety requirements. DIRECTIVE COMPLIANCE Machine Directive 98/37/EC Low Voltage Directive 73/23/EC Electromagnetic Compatibility Directive 89/336/EC REGULATION COMPLIANCE Regulation Title OHA 29 CFR Requirements and afeguarding 1910.217 of Mechanical Power Presses TANDARD COMPLIANCE tandard Title EN 292 afety of Machinery Basic Concepts, General Principles for Design EN 60204 afety of Machinery Electrical Equipment of Machines EN 954-1 afety of Machinery afety related Parts of Control ystem ANI B11.1 Construction, Care and Use of Mechanical Power Presses ANI B11.2 Construction, Care and Use of Hydraulic Power Presses ANI B11.19 afeguarding Performance Criteria for the Design, Construction, Care and Use ANI/RIA afety Requirements for Industrial R15.06 Robots and Robot ystems UL 508 Industrial Control Equipment NFPA 79 Electrical tandard for Industrial Machinery 107080-10 -EN FR26 GLO 202 Printed in Germany 1

PECIFICATION Input minal voltage 24 Vac, (-20 %, +10 %), 24 Vdc (-10 %, +10 %) minal consumption ac: 2,1 VA; dc: 1,5 W minal frequency 50 Hz to 60 Hz Output Contacts 4 NO, 1 NC contacts Contact type afety relay, positive-guided Response time Max. 35 ms witching Capability Power factor = 1 with resistive load Current Range (min. to max.) 1 ma to 5 A (see Caution) Voltage Range (min. to max.) 0,1 to 250 Vac/dc witching capability per NO contact: 3 A/250 Vac NC contact : 2 A/250 Vac AC15 (EN60947-5-1) Typical Electrical Life Expectancy Power factor = 1 at 230 Vac (see te 1) 1 A 2 000 000 operations 2 A 1 000 000 operations 5 A 220 000 operations Typical Power Factor (cos ϕ) Limitation Factor (see te 2) 0,3 0,45 0,5 0,70 0,7 0,85 1 1 Operating frequency 1200 operating cycles/h Fuse rating 4 A time delayed (max.) Mechanical life Ten million operating cycles General Temperature range -15 C to + 55 C (5 F to 131 F) at 90 % humidity (max.) ealing Housing IP 40; Terminals IP 20 Housing material Thermoplastic Vibration resistance Amplitude 0,35 mm; Frequency 10 to 55 Hz Wire connection 1 x 2,5 mm 2 solid (max.) [14 AWG] or 2 x 1,5 mm 2 (max.) [16 AWG] stranded wire with sleeve DIN 46288 Wire/conductor attachment Removable terminal strips with M 3,5 screws; wire contacts are enclosed to prevent from electrical shock Mounting Quick install rail mounting EN 50022-35, width: 35 mm (1.38 in) Weight 180 g (0.39 lb) NOTE 1: Install arc suppression device across load to avoid module contact arcing and ensure specified relay life expectancy. Install module to allow maximum air circulation around the safety module. NOTE 2: Total operations = operations at power factor 1 multiplied by the limitation factor. If the power factor is 0,5 at 230 Vac, 2 A (1 000 000 operations), the limitation factor is 0,70. Total operations: 1 000 000 x 0,70 = 700 000 Figure 1. Contact life for 100 % resistive load (typical) power factor = 1 (cos ϕ), (see te 1) Operations 10 7 7 5 3 2 10 6 7 5 3 2 10 5 0,5 1 1,5 2 witching Power [kva] FRE5929_5 Figure 2. Limitation factor for inductive loads Power factor < 1 (cos ϕ), (see te 2) Limitation factor F 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,2 0,4 0,6 0,8 1 Power factor FRE5929_4 Contact damage To ensure the 1 ma switching capability during the lifetime of the contact, never exceed 300 ma or 60 V. Failure to comply with these instructions will result in loss of low current switching capability. 2 107080-10 -EN FR26 GLO 202 Printed in Germany

Figure 3. QUADRATIC TOTAL CURRENT LIMIT Figure 5. INTALLATION DIAGRAM I 2 (A 2 ) Quadratic total current (A 2 ) 120 100 80 60 40 20 0 10 20 30 40 50 60 T ( C) 32 50 68 86 104 122 140 T ( F) Ambient temperature Quadratic total current limit (see figure 3) displays the maximum recommended external temperature versus the total load of all the safety module contacts. To use this curve, do the following: (1) quare the current in each contact branch, then sum all the results to obtain the vertical axis value. (2) Follow the horizontal line from the obtained value and note intersection of the appropriate curve. (3) Follow the intersection point down to determine the maximal recommended external temperature. (Ex: Ι 2 = 120 A 2 current inside safety contacts, then T = 35 C (95 F). If the module is located in a higher temperature environment, the lifetime of the electronic components may be reduced. Ventilation of the cabinet may be required. MECHANICAL INTALLATION The FF-RE59292 must be installed inside a NEMA 3 (IEC IP 54) rating enclosure or better. The module can be clipped easily onto a 35 mm (1.38 in) width DIN rail (see Figure 4) for DIN rail installation and removal. pecific features of this product include removable block terminals. This feature provides easy access to wiring during installation and reduces machine downtime during maintenance. To remove a terminal block, slide the terminal block out using a screw driver (see Figure 6). Figure 4. Mounting dimensions (for reference only) a Width: 22,5 mm / 0.89 in b Height: 74 mm / 2.91 in c Depth: 121 mm / 4.77 in 22,5 FRE5929_6 Figure 6. REMOVABLE TERMINAL BLOCK crewdriver Removable Terminal Block CONTROL RELIABILITY Control Reliability essentially means that the sensor, system or interface shall be designed, constructed and interfaced such that any single component failure within the device, interface or system shall not prevent normal stopping action from being applied but shall prevent the initiation of a successive operation until the failure is corrected. OHA 29 CFR 1910.217 states that the device shall be constructed so that a failure within the system does not prevent the normal stopping action from being applied to the press when required, but does prevent initiation of a successive stroke until the failure is corrected. The failure shall be indicated by the system. AFETY CATEGORY OF INTERFACE The safety category of the complete interface is dependent on the safety category of the main safety device (emergency stop modules, safety light curtains, etc.) and the way of interconnecting it to the FF-RE5929 Extension module. The safety of the interconnection mainly relies on redundancy and the final switching device monitoring: afety devices offering the Final witching Device (FD) monitoring capability provide the compulsory monitoring of the correct functioning of the internal relays of the FF-RE59292 Extension module. Interconnecting the FF-RE59292 extension module to the emergency stop module using two redundant channels and the emergency stop module s FD monitoring capability help to build a safe electrical interface. FR1 FRE5929_9 74 Rail 118 FRE5929_3 107080-10 -EN FR26 GLO 202 Printed in Germany 3

ELECTRICAL INTALLATION ELECTRICAL HOCK Remove power from FF-R eries control modules and machine during installation. Failure to comply with these instructions could result in death or serious injury. Multiple wiring configurations are possible for the FF-RE59292 extension control module. General guidelines are provided because there are various ways to interface the module to machine control circuitry. Refer to the important warnings (page 5) and the application examples (pages 6 through 7). Figure 7. TERMINAL ARRANGEMENT A1 A2 A3 A4 A1 A3 51 13 23 33 43 14 24 34 44 A2 A4 52 FUNCTIONAL DECRIPTION This module receives two safety inputs between A1/A2 and A3/A4 from a connected safety device. If a safety device is actuated (an emergency stop condition occurs), the normally open contacts will open immediately and the normally closed contact will close. When wired correctly to a proper machine control, the emergency stop condition is signalled to the machine control circuitry by the module s normally open safety contacts to stop the hazard and remove power. Figure 8. BLOCK DIAGRAM 51 52 FRE5929_7 The normally closed contact of the extension module (51/52) must be connected to the Final witching Device (FD) monitoring loop of the connected safety device. This configuration will ensure that the two safety relays in the extension module are operating correctly. One or more FF-RE59292 Extension Modules can be cascaded or external contactors with positive guided safety contacts can be used to increase the number of contacts. If multiple safety contacts are used in parallel with one load, the maximum admissible current can be increased. LED INDICATOR The FF-RE59292 module has two green LED status indicators ( and ) as illustrated in Figure 9. Illuminated and/or LEDs indicate(s) that the corresponding internal safety relay is energized. Both and relays must be energized to have the normally open contacts 13/14 43/44 in a closed condition. If one of the safety relays de-energizes, the normally open contacts will open immediately. Figure 9. MODULE FRONT PANEL 13 14 A1 23 A3 51 FF-RE59292 33 43 13 23 33 43 51 14 24 34 44 52 24 34 44 A2 A4 52 FRE5929_10 A1 A3 13 23 33 43 51 A2(-) A4(-) 14 24 34 44 52 FRE5929_8 4 107080-10 -EN FR26 GLO 202 Printed in Germany

APPLICATION WARNING IMPROPER INPUT CONNECTION To ensure the highest level of safety, connect the two safety device outputs to the redundant inputs A1/A2 and A3/A4 of the FF-RE59292 Extension Module. If only one safety output from the safety sensor is used, connect the FF-RE59292 module as shown in the single input channel example. In this case, take extra precaution to avoid any short circuit possibilities on this single input channel. Conduit may be used to protect wiring. Additional protection may also be applied to the terminal strips inside the machine cabinets to avoid any possible short circuits. IMPROPER FF-RE59292 MONITORING Always connect the normally closed contact of the extension module (51/52) to the Final witching device (FD) monitoring loop of the safety control module or any other safety sensor offering the FD monitoring capability. This configuration will ensure that the two internal safety relays of the extension module are checked and operate correctly. CONTACT WELDING Always protect all safety contacts with correctly rated fuses. These fuses must never exceed the rated FF-RE59292 safety output capability to prevent contact welding. IMPROPER EXTERNAL AFETY RELAY MONITORING When using additional safety relays, always connect one normally closed contact of each relay in series to the Final witching Device (FD) monitoring loop of the safety control modules or any other safety device offering the FD monitoring capability. This connection will ensure correct operation of the external relays after each FF-RE59292 activation. If the FF-RE59292 is not activated often, the customer should perform additional test procedures of the safety components. This testing may be done every day by removing the power from the FF-RE59292 at machine power up. IMPROPER ARC UPPREOR INTALLATION NEVER install an arc suppressor across the safety output contact of the safety control module. ALWAY install arc suppressors across the coils of external safety relays. Failure to comply with these instructions could result in death or serious injury. NOTICE The FF-RE59292 will immediately change state when the two input channels A1/A2 and A3/A4 receive power. timing limitation exists when power is applied to each of these two inputs. 107080-10 -EN FR26 GLO 202 Printed in Germany 5

APPLICATION EXAMPLE Figure 10. Two channel connection of an FF-RE59292 extension module to a FF-R59352 Dual Channel Emergency top Module (Recommended interface) 24 Vdc Fuse Dual output of safety switching devices (A) (OD) (A) OD1 OD2 0 Vdc A1 Power A2 (-) K3 11 33 1 2 12 34 22 Internal witches 21 PE Restart pushbutton 13 23 33 41 FF-R59352 14 24 34 42 0 Vdc 1 and 1 NC afety Contacts A1 A2 (-) A3 FF-RE59292 0 Vdc A4 (-) 14 13 23 Machine Control 33 43 24 34 44 4 NO afety Contacts This circuit uses redundancy in the extension module circuit, because of its two channel connection to the emergency stop module. It offers the highest possible safety level. APPLICATION NOTE: NOTE (A): Dual Channel afety devices This may be a dual output safety switching device (OD) with cross-monitoring such as emergency push-buttons, safety light curtains (FF-B, FF-L), single beam (FF-P), modular safety light curtains (FF-CAN), safety laser scanner (FF- E), dual output safety limit or interlock switches with positive opening (for example, 2CL and GK). FUNCTIONAL DECRIPTION: After activation of the safety device, both LEDs and K3 of the FF-R59352 emergency top module will turn OFF, indicating that the two internal safety relays and K3 are de-energized. The normally open safety outputs 13/14, 23/24 and 33/34 will open and the normally closed safety output will close. Then both LEDs and on the FF-RE59292 extension modules go off indicating that the two internal safety relays are de-energized. afety contacts 13/14 to 43/44 open and 51/52 closes. 1. After removing the emergency stop condition, press and release the restart push-button to restart the FF-R59352 emergency stop module. 2. If the FF-RE59292 extension module is operating properly, both LEDs and K3 of the FF-R59352 module illuminate, indicating that the safety relays and K3 are energized. At this time, the three normally open safety contacts will close and the normally closed safety contact will open. Both LEDs and of the FF-RE59292 illuminate, indicating that safety relays and are energised. afety contacts 13/14 to 43/44 will close and 51/52 will open. This action will allow the machine to operate. The proper operation of the FF-RE59292 extension module is monitored by connecting the NC contacts 51/52 in series to the restart circuit (33/34) of the FF-R59352 emergency-stop module. 51 52 FRE5929_12 6 107080-10 -EN FR26 GLO 202 Printed in Germany

Figure 11. One channel connection of an FF-RE59292 Extension Module to a FF-R59342 ingle Channel Emergency top Module 24 Vdc Fuse ingle Channel afety Device (A) 0 Vdc Restart pushbutton A1 Y1 Y2 13 23 Power / 33 34 1 NC safety contact FF-R5934 13 23 14 24 14 24 A2 (-) A1 A2 (-) A3 FF-RE59292 A4 (-) 14 13 23 Machine Control 33 43 51 24 34 44 52 4 NO safety contacts This circuit has NO redundancy in the extension module circuit due to the single channel connection to the emergency stop module. This interface offers a lower safety level. APPLICATION NOTE te (A): ingle Channel afety Devices This may be an emergency stop push-button or another single output safety device such a safety limit switch or key interlock switch (for example: CL, GK or G). FUNCTIONAL DECRIPTION: After activation of the safety device, the LEDs Power and / of the FF-R59342 Emergency top module will turn OFF, indicating that the two internal safety relays and are de-energized. The normally open safety outputs 13/14 and 23/24 will open. Then, both LEDs and of the FF-RE59292 extension modules go off indicating that the two internal safety relays are de-energized. afety contacts 13/14 to 43/44 open and 51/52 closes. 1. After removing the emergency stop condition, the LED Power will light on. Press and release the restart pushbutton to restart the FF-R59342 emergency stop module. 2. If the FF-RE59292 extension module is operating properly, the LED / of the FF-R59342 module illuminate, indicating that the safety relays and are energized. At this time, the two normally open safety contacts will close. Both LEDs and of the FF-RE59292 illuminate, indicating that safety relays and are energised. afety contacts 13/14 to 43/44 will close and 51/52 will open. This action will allow the machine to operate. FRE5929_13 The proper operation of the FF-RE59292 extension module must be monitored connecting the rmally Closed contacts 51/52 between Y1/Y2 of the FF-R59342 emergency stop module. 107080-10-EN FR26 GLO 202 Printed in Germany 7

Figure 12. FF-RE59292 troubleshooting flow diagram Machine Down FRE5929_14 Damaged contacts. Ensure maximum load is within specification. Replace module. Are the outputs contacts 13/14,..., 43/44 closed? Are AND LEDs ON? Machine Working Is the problem resolved? The problem is external to the module. Check for external causes (wiring, etc.). Replace the safety module. Are AND LEDs OFF? Is the contact 51/52 closed? Is voltage between A1/A2 AND A3/A4 present AND within specifications? Apply correct voltage AND/ OR check for correct operation of previous connected safety device. Replace safety module and activate restart circuitry. 8 107080-10 -EN FR26 GLO 202 Printed in Germany

WARRANTY AND REMEDY warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to during that period of coverage, will repair or replace without charge those items it finds defective. The foregoing is the Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. ORDER GUIDE FF-RE5929 G Voltage: 2 = 24 Vac/dc (only) While we provide application assistance, personally, through our literature and the website, it is up to the customer to determine the suitability of the product in the application. pecifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. ALE AND ERVICE serves its customers through a world-wide network of sales offices and distributors. For application assistance, current specifications, pricing or the name of the nearest distributor, contact a nearby sales office or call: TELEPHONE + 61 (0) 2 9370 4500 Australia + 1-800-737-3360 Canada + 33 (0) 1 60 19 82 68 France + 49 (0) 69 8064 444 Germany + 34 91 313 61 00 pain + 1-815-235-6847 International + 44 (0) 1698 481 481 UK + 1-800-537-6945 UA FAX + 61 (0) 2 9370 4525 Australia + 1-800-565-4130 Canada + 33 (0) 1 60 19 81 73 France + 49 (0) 69 8064 442 Germany + 34 91 313 61 29 pain + 44 (0) 1698 481 276 UK + 1-815-235-6545 UA EC DECLARATION OF CONFORMITY INTERNET http://www.honeywell.com/sensing/ info.sc@honeywell.com 2002 International Inc. All rights reserved. Control Products 21, Chemin du Vieux Chêne 38243 Meylan Cedex - FRANCE IO 9OO1 AFAQ N 1994/2213 C E R T Q U A L I T Y I F I E D E Net Y T E M 107080-10-EN FR26 GLO 202 Printed in Germany