Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Similar documents
Fiber Optic Cabling Systems for High Performance Applications

Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

400GE at the Cost of 4 x 100GE

DC Network Connectivity

100G and Beyond: high-density Ethernet interconnects

Next-gen 400 and 200 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation. IEEE Draft 0.3

Arista 400G Transceivers and Cables: Q&A

DELL EMC NETWORKING TRANSCEIVERS AND CABLES

400G PAM4 The Wave of the Future. Michael G. Furlong - Senior Director, Product Marketing

Ethernet evolution: what s new and what s next

New Data Center and Transport Interconnect Technology

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

ETHERNET OPTICS TODAY: 25G NRZ

Consensus building discussion on next-generation MMF PMDs. Presented by Robert Lingle, Jr. IEEE Interim Huntington Beach, CA January 9 th, 2017

Pivotal Issues for 400 Gb/s Ethernet

Cisco 100GBASE QSFP-100G Modules

Dell Networking Optics and Cables Connectivity Guide

Ethernet The Next Generation

Ethernet 100G and Beyond

Roadmap to 400 Gigabit Ethernet over Multimode Fiber WHITEPAPER

WHITE PAPER THE CASE FOR 25 AND 50 GIGABIT ETHERNET WHITE PAPER

100G SWDM4 MSA Technical Specifications Optical Specifications

100 GBE - WHAT'S NEW AND WHAT'S NEXT

Optics Modules and Cables Data Sheet

40G and 100G Products

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Next-gen 200 and 400 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation

Disruptive Technologies Shaping Data Center Growth

High Speed Migration 100G & Beyond

Data center applications standards reference guide

Scaling the Compute and High Speed Networking Needs of the Data Center with Silicon Photonics ECOC 2017

Optical Trends in the Data Center

Data Center High Speed Migration: Infrastructure issues, trends, drivers and recommendations

128GFC. Fiber Channel Leading Charge for Higher Speeds Skip Jones Date: Tuesday, October 15 Time: 2:10pm 2:50pm Location: Room 102B

Higher Speed Ethernet

Next-gen 200 and 400 Gb/s PHYs over Fewer MMF Pairs Call For Interest Consensus Presentation

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

Cisco 100GBASE QSFP-100G Modules

What s the technology Buzz at the 2017 Optical Fiber Communications Conference?

The Ethernet Rate Explosion John D Ambrosia

Cisco 40GBASE QSFP Modules

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

ETHERNET ROADMAP UPDATE. Scott Kipp October 2014

Ethernet Adoption: SERDES Rates & Form Factors

Data Center Optical Connectivity with Bend-Optimized OM3/OM4 Multimode Optical Fiber

Trends in Testing Data Center Infrastructure. Ed Gastle VIAVI Solutions

40 Gbit/s Small-Form Low-Power Optical Transceiver

Optics Modules and Cables Data Sheet

Delivering100G and Beyond. Steve Jones Phone: blog.cubeoptics.

In Support of a 500m objective for 200G Ethernet: Part II

100G-Optics Next Gen Possible PMD Set

Adrian Young Leviton Network Solutions

Optical multi-speed splitting

Fiber in Data Centers What s Next? Srinivasan B, RCDD

QDR Active Optical Cables. SC 10 New Orleans

Future Datacenter Interfaces Based on Existing and Emerging Technologies

Wideband Multimode Fiber What is it and why does it make sense?

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity

Objectives for HSSG. Peter Tomaszewski Scientist, Signal Integrity & Packaging. rev3 IEEE Knoxville Interim Meeting, September 2006

Alternate Path to Consensus on 400 GbE PMDs

25 Gb/s Ethernet Study Group CSD: Technical Feasibility. Joel Goergen - Cisco Matt Brown APM Version goergen_25ge_01_0914d

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd.

Ethernet Alliance Technology Exploration Forum 2014 The Rate Debate

Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center

Objectives for NG 200G and 400G PHYs

Optical Transceivers for 100GE

Optical Fiber Networks: Industry. and New Options for Networks

Arista 7500 Series Interface Flexibility

DENSIFICATION DATA CENTER JULY 2018 FOR PROFESSIONALS MANAGING THE CABLE AND WIRELESS SYSTEMS THAT ENABLE CRITICAL COMMUNICATIONS DESIGN TECHNOLOGY

Expanding your network horizons

Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk?

Brocade Ethernet Optics Family

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

100 GIGABIT ETHERNET. So we ve got 802.3ba, now what do we do with it? Chris Bull Service Provider ANZ

THE FABULOUS, FAST MOVING, FEVER PITCH, FOREVER ACCELERATING FIBER FRENZY Rodney Casteel, RCDD, DCDC, NTS, OSP - CommScope, Chair TIA FOTC Cindy

LAN Standards, News & Trends Update 2017 June 15, 2017

Data Center architecture trends and their impact on PMD requirements

Connectivity Solutions Utilizing Base-8 Structured Cabling

Technical Feasibility of 4x10G and 10x10G Electrical Interfaces

Is 1Tb/s Ready for Prime Time? Engineering Reality Check

Industry Standards for the Exponential Growth of Data Center Bandwidth and Management. Craig W. Carlson

BROCADE OPTICS FAMILY

Driving the future of datacenters

Corning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver

OIF CEI-56G Project Activity

ProLabs new product releases

400GBase-LR8: A Proposal for 10 km Objective Using 50 Gb/s PAM4 Signaling

OFC/NFOEC 2011 Interoperability Demonstration

100 GBE AND BEYOND. Diagram courtesy of the CFP MSA Brocade Communications Systems, Inc. v /11/21

ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide

ARISTA WHITE PAPER Arista 7500E Series Interface Flexibility

Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables

Solutions Guide. Pluggable Optics for the Data Center

Solutions Guide. Pluggable Optics for the Data Center

Datacom Market Update

100 Gigabit Ethernet. An Industry Update. John D Ambrosia Chair, IEEE P802.3ba Task Force Senior Scientist, Force10 Networks October 8, 2009

Transcription:

Optical Trends in the Data Center Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Telecom 2017 Corning Restricted Incorporated 2

Server Access Switch Speed Migration Increased server access switch data rates demand higher data rate uplinks 40/100/200/400G Telecom 2017 Corning Restricted Incorporated 3

Server and Switch Trends Telecom 2017 Corning Restricted Incorporated 4

40/100/400G Switch Port Transition Telecom 2017 Corning Restricted Incorporated 5

Speed Migration on Servers Total Market Telecom 2017 Corning Restricted Incorporated 6

Speed Migration on Servers Cloud Market Telecom 2017 Corning Restricted Incorporated 7

Enterprise Only Telecom 2017 Corning Restricted Incorporated 8

Enterprise and Hyperscale Telecom 2017 Corning Restricted Incorporated 9

OM3 System Length System Length Product Manufactured 01/2014-12/2016 50% 1 Trunk, 40% 2nd Trunk, 10% 3rd Trunk 2000 12000% Frequency 1800 1600 1400 1200 1000 800 600 Average: 491 m 10000% 922% 8000% 6000% 4000% Frequency Cumulative % 400 200 2000% 0 000% 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 More System Length (meters) Telecom 2017 Corning Restricted Incorporated 10

OM4 System Length System Length (OM4) Product Manufactured 01/2014-12/2016 50% 1 Trunk, 40% 2nd Trunk, 10% 3rd Trunk 1850 12000% 1650 1450 10000% 903% 1250 8000% Frequency 1050 850 650 450 Average: 487 m 6000% 4000% Frequency Cumulative % 250 50 2000% -150 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 More System Length (meters) 000% Telecom 2017 Corning Restricted Incorporated 11

Single-Mode Enterprise 1400 1200 System Length (SM-without Hyperscale) Products Manufactured 01/2014-12/2016 50% 1 Trunk, 40% 2nd Trunk, 10% 3rd Trunk 12000% 10000% 1000 8000% Frequency 800 600 400 Average: 757 m 748% 6000% 4000% Frequency Cumulative % 200 2000% 0 000% System Lengths (meters) Telecom 2017 Corning Restricted Incorporated 12

Single-Mode Hyperscale Hyperscale System Length (OS2) Product Manufactured 01/2014-12/2016 20% 1 Trunk, 80% 2nd Trunk 12000% 500 10000% 400 8000% Frequency 300 Average: 1645 m 6000% Frequency Cumulative % 200 4000% 100 295% 2000% 0 10 30 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 System Length (meters) 000% Telecom 2017 Corning Restricted Incorporated 13

Data Center Fabrics SAN HPC LAN Telecom 2017 Corning Restricted Incorporated 14

Data Center Logical Data Flow LAN Core Switch SAN Switch Ethernet Edge Switch Fiber Channel Ethernet Fiber Channel OM4 Cable Twinax Cable Server Storage Telecom 2017 Corning Restricted Incorporated 15

40GbE Port Roadmap Physical Medium Dependent Sublayers for 40GbE PMD Name Electrical Interface to Optical Module Reach Medium Date Standard Ratified 40GBASE-CR4 Not Applicable 7 m Twinax 2010 40GBASE-SR4 XLAUI / XLPPI 100/150 m OM3/OM4 2010 40GBASE-LR4 XLAUI / XLPPI 10 km OS1/OS2 2010 40GBASE-FR XLAUI 2 km OS1/OS2 2011 40GBASE-ER4 XLAUI 40 km OS1/OS2 2015 40GBASE-T Not Applicable 30 m Cat 8 2016 Source: Ethernet Alliance Telecom 2017 Corning Restricted Incorporated 16

40GeSR4 Extended Reach Parallel Optics 40G esr4 Parallel Optics Extended Reach OM3/OM4: o 300 m / 400 m (Standard Assumptions) o 330 m / 550 m (Corning Connectivity) Corning collaborated with FIT (Avago) to verify the QSFP+ esr4 modules met link distance specifications for 40G Ethernet applications Internal testing demonstrated 1250m+ with random transceiver and OM4 fiber Source: Avago Commercially available now Telecom 2017 Corning Restricted Incorporated 17

40G BiDi MMF Transmission Performance Duplex OM3/OM4/OM5 LC Connectivity/Polarity QSFP Transceiver Form Factor (35w) Up to 100/200/200m on OM3/OM4/OM5 Tap Modules Available Telecom 2017 Corning Restricted Incorporated 18

40G Duplex OM3/OM4/OM5 SWDM Transmission 40G SWDM QSFP transceiver 4x10G WDM Distance: OM3/OM4/OM5: 240/350/440m Expected Commercial Availability: 2017 SWDM Manufacturers Finisar and Lumentum Source: swdm Alliance Telecom 2017 Corning Restricted Incorporated 19

High Level Differences Between SR4 and BiDi/SWDM LC Duplex Cable 2F BiDi/SWDM MPO Connector 8/12F MPO 100G GbE QSFP 100G GbE QSFP Telecom 2017 Corning Restricted Incorporated 20

100GbE Port Roadmap PMD Name Electrical Interface to Optical Module Reach Medium Date Standard Ratified 100GBASE-CR10 N/A 7 m Twinax 2010 100GBASE-SR10 CAUI-10 100/150 m OM3/OM4 2010 100GBASE-LR4 CAUI-10 10 km OS1/OS2 2010 100GBASE-ER4 CAUI-10 40 km OS1/OS2 2010 100GBASE-CR4 N/A 5 m Twinax 2014 100GBASE-SR4 CAUI-4 70/100 m OM3/OM4 2015 100GBASE-LR4 CAUI-4 10 km OS1/OS2 2015 Source: Ethernet Alliance Telecom 2017 Corning Restricted Incorporated 21

8023bm 100GBASE-SR4 Guidance Identical Parallel Optical Lane Assignments to 40GBASE-SR4 Identical 8F MPO Connectivity for 40GBASE-SR4 and 100GBASE- SR4 24F MPO Connectivity not Compatible Eight OM3 or OM4 Multimode Fiber Compatible Source: IEEE Draft 8023bm and 8023ba Telecom 2017 Corning Restricted Incorporated 22

8023bm 100GBASE-SR4 Guidance 8 or 12F MPO Maximum link distance is based on an allocation of 15 db total connection The loss of a single connection shall not exceed 075 db The maximum discrete reflectance shall be =< 20 db 12F MPO 12F MPO Transceiver Interface Source: IEEE 8023bm and 8023a Telecom 2017 Corning Restricted Incorporated 23

Extended Link esr4 QSFP28-100GBASE-eSR4 Type MMF Transceiver Identical build standard to 100G QSFP28 SR4 300m (200m) target OM4 (OM3) MMF transmission FEC per IEEE 8023bm for both SR4 and esr4 4 x 2578Gb/s VCSEL TOSA/ ROSA Operating temperature 0ºC to 70ºC 30W max power consumption (CDRs on) Compliant to QSFP28 MSAs, Technology scalable to 25GE SFP28 esr l Source FIT Available 4 th Quarter 2017 Telecom 2017 Corning Restricted Incorporated 24

100G BiDi MMF Transmission Performance Duplex OM3/OM4/OM5 LC Connectivity/Polarity 2x50G PAM4 or 2x20G NRZ 850nm/900nm wavelengths FEC Integrated into Transceiver QSFP Transceiver Form Factor Up to 70/100/150m on OM3/OM4/OM5 Backward compatible with 40G BiDi Available late 2017 100GE PAM4 BiDi In QSFP28 Source FIT Source: FIT Telecom 2017 Corning Restricted Incorporated 25

100G Duplex OM3/OM4/OM5 SWDM Transmission 100G SWDM QSFP transceiver 4x25G WDM Distance: OM3/OM4/OM5: 75/100/150m Expected Commercial Availability: 2017 SWDM Manufacturers Finisar and Lumentum Source: swdm Alliance Telecom 2017 Corning Restricted Incorporated 26

100G SM Activity IEEE failed to acquire 75% membership approval for a 100G SM short reach (500m to 2km) variant Proprietary Alliance/MSA Activities Data Center Focus CWDM4 MSA 1310nm, 4x25G cwdm4 500m 2km PSM4 MSA 1310nm and 1550nm 4x25G parallel =< 500m 4x25G QSFP28 4x25G Source FIT SM Telecom 2017 Corning Restricted Incorporated 27

IEEE 8023 25 Gb/s Ethernet 8023by Task Group ToR to Server interconnect focus 25G Objectives: MMF at least 100m (2F) Twinax at least 3m and 5m Standard completed July 2016 8023cc Task Group ToR to Server interconnect and Carrier focus 25G Objectives SM at least 10km (2F) SM at least 40km (2F) Estimated Standard completion October 2017 AOC, Pluggable Transceiver Modules and Twinax Will be Primary Server Interconnect Method Source: IEEE 8023 Call For Interest 25Gb/s Ethernet over a single lane for server interconnect July 2014 San Diego Telecom 2017 Corning Restricted Incorporated 28

IEEE 8023bs 400G Ethernet Task Force Study Group Adopted November 2013 400G Objectives: At least 100 m over MMF At least 500 m over SMF At least 2 km over SMF At least 10 km over SMF Hyperscale Data Center Focus IEEE 8023bs 400G Task Force Approved March 2014 Expected standard completion date: December 2017 Telecom 2017 Corning Restricted Incorporated 29

400G MMF Variants First Generation Standards Guidance 32F Parallel Optics (2017) 400GBASE-SR16 Tx 16x25G and Rx 16x25G (NRZ) 32F MPO Connector, Double Array Minimal traction expected with AOC primary use (Pending) Second Generation Expected to Utilize 8F Parallel Optics with WDM (2019) Tx 4x100G and Rx 4x100G Two wavelengths at 25Gbaud PAM4 Four wavelengths at 25Gbaud NRZ 8/12F MPO Connector Deployed as pluggable module / embedded optics for core to edge uplinks Source: USConec 2x16 format 1x12 or 8 format Telecom 2017 Corning Restricted Incorporated 30

IEEE 8023bs adopts 200G SM 200Gb/s PHYs SMF at least 2km (2F) 200GBASE-FR4 SMF at least 10km (2F) 200GBASE-LR4 SMF at least 500m (8F) 200GBASE-DR4 50G PAM4 Modulation 200G SMF Parallel 4x50G (PAM4) Telecom 2017 Corning Restricted Incorporated 31

400G SMF Variants At least 500m - 8F Parallel Optics 400GBASE-DR4 Tx 4x100G and Rx 4x100G (50Gbaud PAM4) 8F or 12F MPO Connector At least 2km - 2F Serial Optics 400GBASE-FR8 8x50G WDM (25Gbaud PAM4) 2F LC Connector At least 10km - 2F Serial Optics 400GBASE-LR8 8x50G WDM (25Gbaud PAM4) 2F LC Connector 200/400G SM Connector RL Requirements : MPO: -45 db, LC : -35 db Telecom 2017 Corning Restricted Incorporated 32

400G Pluggable Modules QSFP-DD and OSFP 32 ports per 1U line card 100/200G breakout capability Module power 10-12w MPO or LC Connector MM and SM Capable 2018-2019 Availability OSFP QSFP-DD Micro-LC 32 OSFP or 32 QSFP-DD Ports 128 Tb / 1U Telecom 2017 Corning Restricted Incorporated 33

Multi-Level Encoding 50G (PAM4) MMF and SMF Non-Return to Zero (NRZ) Typical modulation method to 25G at 1 bit / symbol Electrical channel loss and noise issues at =>25G Two amplitude levels Potential MMF VCSEL NRZ limit Pulse Amplitude Modulation (PAM4) Evolving systems increase the amount of information (bits) sent with each symbol Requires more complex transceivers Doubles the BW with 2 bits/symbol Four amplitude levels 4-6 dbo optical penalty FEC power gain compensates Extends MMF VCSEL lifecycle Source:KEYSIGHT Technologies Telecom 2017 Corning Restricted Incorporated 34

PAM4 ASIC: 100G Module Implementation Example 50G PAM4 Each TOSA lasers 4*25G CAUI-4 Electrical Interface 4 Lane CAUI RX 4 Lane CAUI TX FEC Encod e PAM ASIC FEC Decod e PAM output ADC & DSP CDR DRV DRV TIA TIA P D x2 Optical Mux ROSA 2 λ 100G Optical Optical Demux 50G PAM4 Each Telecom 2017 Corning Restricted Incorporated 35

IEEE 8023cd 50/100/200G Task Force 50Gb/s MMF at least 100m (2F) 50GBASE-SR - 25Gbaud PAM4 SMF at least 2km (2F) 50GBASE-FR - 25Gbaud PAM4 SMF at least 10km (2F) 100 Gb/s, 50GBASE-LR 25Gbaud PAM4 MMF at least 100m (4F) 100GBASE-SR2 25Gbaud PAM4 25Gbaud PAM4 SMF at least 500 m (2F) 100GBASE-DR 50Gbaud PAM4 200 Gb/s MMF at least 100m (8F) 200GBASE-SR4 25Gbaud PAM4 Source: Brocade Telecom 2017 Corning Restricted Incorporated 36

Ethernet Speed Roadmap Ethernet Speed Roadmap Telecom 2017 Corning Restricted Incorporated 37

Ethernet Speed Roadmap Ethernet Speed Roadmap Telecom 2017 Corning Restricted Incorporated 38

Fiber Channel Speed Roadmap Source: FCIA Speedmap v20 Telecom 2017 Corning Restricted Incorporated 39

FC-PI7 64G / 256G Objectives Backward compatibility to 32GFC and 16GFC Same external connectors as present connector LC and SFP+ for 64GFC MPO and QSFP56 for 256GFC Distances 100m on OM4 cables for 64GFC (2F) 10km on SMF cables for 64GFC (2F) 100m on OM4 cables for 256GFC (8F parallel) 2km on SMF cables for 256GFC (8F parallel, 2F WDM) PAM4 multi-level encoding (28 GBaud (56GFC)) Server virtualization and flash storage require higher FC data rates Standard Completion 2018 Telecom 2017 Corning Restricted Incorporated 40

Server Virtualization Drives Higher Data Rates Multiple applications run in parallel on one server Increases utilization efficiency from < 20% to >70% CPU cores (4,8,1828) Typical Enterprise / Hyperscale server:4-12 cores Typical HPC server: 18-28 cores Typical 2-3GHz/core Increased Memory (6-12 TB) PCIe2: 8 lanes @ 5G 8b/10b PCIe3: 16 lanes @ 8G 128b/130b PCIe4: 16 lanes @ 16G 128b/130b (2018) Drives utilization of high data rate optical connectivity (40/100/400G) to support increased sever I/O speeds (10/25/50/100G) Telecom 2017 Corning Restricted Incorporated 41

Switch ASIC Roadmap Source: Broadcom Source: Broadcom Source: Broadcom Telecom 2017 Corning Restricted Incorporated 42

Ethernet Lane Speed Transition Telecom 2017 Corning Restricted Incorporated 43

Switch Silicon Manufacturing Status Source: Lightcounting Source: Lightcounting Telecom 2017 Corning Restricted Incorporated 44

Switch ASIC Environment Broadcom Tomahawk 32 Tb/s ASIC 128x25G SerDes lanes 7 Billion Transistors ~200W power dissipation 32x100G Ports, 128x25G ports, 64x50G ports Expected Industry ASIC Roadmap 32 Tb/s (25G per lane, 100G/port) 48Tb/s (25G per lane, 100G/port) 64 Tb/s (25/50G per lane, 100G/port) 128 Tb/s (50/100G per lane, 400G/port 256 Tb/s (100G per lane, 800G/port) 1 of 32 Quad SerDes Accton Switch with Tomahawk ASIC 32x100G Source:Broadcom Tomahawk ASIC 32x100G ports Telecom 2017 Corning Restricted Incorporated 45

ACCTON 64x100G 2U Switch (Tomahawk I 256x25G lanes) Telecom 2017 Corning Restricted Incorporated 46

OIF CEI-56G Baseline Clauses 56G PAM4 Telecom 2017 Corning Restricted Incorporated 47

Host Card Electrical Link Source: Brocade Telecom 2017 Corning Restricted Incorporated 48

OIF CEI-112-VSR Electrical Chip to Module Interfaces 56Gbaud (PAM4) Telecom 2017 Corning Restricted Incorporated 49

Evolution of Optical Interconnects Legacy Source: Corning Telecom 2017 Corning Restricted Incorporated 50

Contact Info Doug Coleman 800 17th Street NW Hickory, NC 28601 828-901-5580 dougcoleman@corningcom Telecom 2017 Corning Restricted Incorporated 51