CoNeT Mobile Lab: Ethernet IP on Allen Bradley platform

Similar documents
FieldServer Driver - Ethernet FS EtherNet/IP

FieldServer Driver - Ethernet FS EtherNet/IP

CoNet Mobile Lab: EtherNet/IP on Allen Bradley platform

1769 Expansion Cables

CompactLogix Selection Guide

eth1000_large.jpg Using ICC ETH-1000 EtherNet/IP Interface with Mitsubishi iq PLC

Allen-Bradley Communications Modules Implementing network-based access control for users, devices and networks

Select Family: MicroLogix 1100 or 1400 Controller

Connect to the Future Today with Allen-Bradley s SLC 5/05 Processor with Ethernet

Logix5000 Controllers Design Considerations

EtherNET/IP Software Help File

CompactLogix 5370 L2 Programmable Automation Controllers

PROGRAMMABLE LOGIC CONTROLLERS LAB ELEC 2141

Integrated Architecture. Putting the Pieces Together

EtherNet/IP Communication Modules in Logix5000 Control Systems

SmartRail I/O Ethernet Base HE599ETX300

Tritex II EtherNet/IP - Option

DriveLogix Controller Firmware Revision 11 / RSLogix 5000 Version 11

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview

L05 - PowerFlex Drives Configuration & Programming

CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter

EtherNet/IP with Applied Motion Drives

DEFAULT IP ADDRESS

POINT I/O Family. Chapter. Overview

Modular Controller System KS vario

EtherNet/IP Network Configuration

EtherNet/IP Network Configuration

Integrated Safety & PowerFlex DriveGuard

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Additional instructions Videographic recorder LINAX DR3000. EtherNet/IP Adapter

POINT I/O Family. Chapter. Overview

EtherNet/IP - Getting Started User's Manual

FlexLogix System L33 and 1794-L34. User Manual. Allen-Bradley HMIs

CompactLogix Communication Options

PanelView 5000 Portfolio of Graphic Terminals

PLC-5 Programmable Controllers Comparison

EtherNet/IP Network Configuration

ControlNet Communication Options for 1768 CompactLogix Controllers

Reference Manual. SAI Standard Automation Interface

eth1000_large.jpg Using ICC ETH-1000 EtherNet/IP Interface with Mitsubishi iq PLC

PLC-5 Programmable Controllers Comparison

Select a Micro800 Controller

CompactLogix 5370 L3 Programmable Automation Controllers. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

ControlLogix EtherNet/IP Communication Interface Module

Application Note: 105U/905U-G-ET1 EtherNet IP & CompactLogix PLC

Device-Level Ring Topology

Connections and Data Exchange

Soloist Linear Series

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

EtherNet/IP to Allen-Bradley DH+ or Remote I/O Gateway AN-X-AB-DHRIO

6053/6055 ControlNet Communications Interface

User Manual. PowerFlex ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx

EtherNet/IP Configuration for a Moxa MGate 5105-MB-EIP and an Allen-Bradley CompactLogix L32E. Copyright 2013 Moxa Inc Released on July 15, 2013

ControlNet Network Configuration

FLEX I/O Dual Port EtherNet/IP Adapter Modules

ControlMonitor CoMo View

VersaMax Micro and Nano Technical Product Presentation

PowerFlex 520-Series AC Drives. The Next Generation of Powerful Performance. Flexible Control.

WebAccess Driver Configuration Manual

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

TeSys T LTM R EtherNet/IP with a Third-Party PLC Quick Start Guide

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

EtherNet/IP USER'S GUIDE ACS Servo ACS Stepper ACSI Servo

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

ControlLogix Communication Modules

EtherNet/IP - EtherNet/IP

PowerFlex 750-Series AC Drives

Extending EtherNet/IP TM to Resource- Constrained Industrial Things. Dayin XU, Rockwell Automation Paul Brooks, Rockwell Automation.

ControlsLab TM. Programmable Automation Training

CompactLogix Controllers, Revision 15

CompactLogix System. Selection Guide

Technical Application Note

Input Conversion Type. Response, per Channel. 70 ms at Notch = 60 Hz (default) 80 ms at Notch = 50 Hz 16 ms at Notch = 250 Hz 8 ms at Notch = 500 Hz

FLEX 5000 Digital I/O Modules

Channel Digital Input Module 24 V DC High-side switching

1769 Packaged Controllers

CompactLogix5320. Technical Data. Catalog Number 1769-L20

SMVector EtherNet/IP Communication Module Communications Interface Reference Guide

ControlLogix EtherNet/IP Bridge Module

DIRECTORATE OF TECHNICAL EDUCATION DIPLOMA IN ELECTRICAL AND ELECTRONICS ENGINEERING III YEAR M SCHEME V SEMESTER.

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

SI-EN3 and SI-EN3/V EtherNet/IP Option Product Demonstration Unit Technical Manual

1738 ArmorPOINT I/O EtherNet/IP Adapters

Select Micro800 Plug-in Modules and Accessories

PowerFlex 750-Series AC Drives

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

WAGO Energy Data Management Efficiency Is That Easy!

Logix Controllers Comparison

ControlLogix Controllers Revision 14

M-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

EtherNet/IP USER'S GUIDE ACS Servo ACS Stepper ACSI Servo

Driver Manual. FS EtherNet/IP

RS 485 Mini Modbus 1AO

AKD EtherNet/IP Communication

ArmorPoint I/O Product Compatibility

RS485 MODBUS Module 8I8O

Transcription:

Lesson Ethernet IP on Allen Bradley platform CoNeT Mobile Lab: Ethernet IP on Allen Bradley platform Introduction 1 Distributed control architecture 2 Real-time control system and real-time network 3 Monitoring and testing the Ethernet network 4 Introduction to EtherNet/IP technology 5 Introduction to laboratory: Description of laboratory and basic scenario 6 Software tools Co-operative Network Training 2011 Maciej Rosół, Department of Automatics and Biomedical Engineerimg, AGH University of Science and Technology

What is EtherNet/IP? EtherNet/IP is an industrial application layer protocol (CIP) operating over the Ethernet medium and used for communication between industrial control systems and their components, By Ethernet, we mean a TCP/UDP/IP based network Typically 100 MBps Twisted Pair, star topology and switch Could be 10 MBps Coaxial 1 GBps Fiber 11 MBps Wireless By CIP we mean the Common Industrial Protocol. CIP is an application protocol. It defines rules for organizing and interpreting data and is essentially a messaging structure that is independent of the underlying physical layer. It is freely available and accessible to anyone, and widely supported by many manufacturers. Specification downloadable at www.odva.org EtherNet/IP can be easily confused as a combination of Ethernet (the physical layer, link, or medium used in most office and many industrial networking environments) and the Internet Protocol (IP) 2011 Wojciech Modzelewski, Wojciech Grega, Department of Automatics, AGH-UST <4 Introduction to EtherNet/IP Technology> <4.1 Introduction>

Why is worth to use EtherNet/IP? Open industrial networking standard, Designed for use in process control, hard real-time systems, industrial automation applications, Wide-spread standard (low cost per node), Classified as Class 1 Real Time Ethernet (can be extended to class 2), Emerged from Common Industrial Protocol, TCP/UDP/IP encapsulation, Ensures the desired level of service quality (QoS). 2011 Wojciech Modzelewski, Wojciech Grega, Department of Automatics, AGH-UST <4 Introduction to EtherNet/IP Technology> <4.1 Introduction>

EtherNet/IP in OSI Reference Model Fig. 4.1. (EtherNet/IP), Comparison of DeviceNet and ControlNet OSI [1] 2011 Wojciech Modzelewski, Wojciech Grega, Department of Automatics, AGH-UST <4 Introduction to EtherNet/IP Technology> <4.1 Introduction>

Ethernet/IP type of messages Explicit: Uses TCP/IP connections (port number 0xAF12), Client-server type transactions, Message connections are point-to-point communication paths between two devices, Forms of messaging: - Unconnected messaging (should be used only when the application requires very irregular and infrequent request intervals), - Connected messaging requires setting up a connection first, useful in applications that require periodic requests). Implicit (I/O messaging): Uses UDP/IP connections (port number 0x08AE), Producer-Consumer type transactions, Data field contains only real-time data, UDP packets are transmitted using multicast communication (a specific device allocated IP multicast address). 2011 Wojciech Modzelewski, Wojciech Grega, Department of Automatics, AGH-UST <4 Introduction to EtherNet/IP Technology> <4.1 Introduction>

Ethernet/IP Type of messages - Summary Message type Explicit Implicit Communication relationship Transport protocol Communication type and typical use Unconnected Connected TCP/IP Request/Reply Non time-critical information data Connected UDP/IP I/O Data Transfer Real-time I/O data

CIP device representation Fig. 4.2.. A typical CIP device representation The objects required in a typical device: Connection Object, Identity Object, Network-specific link objects (depends on network), Message Router Object. Access to the device requires object number, instance number and attribute number The CIP Family of Protocols contains a large collection of commonly defined objects. The overall set of object classes can be subdivided into three types: General-use, Application-specific, Network-specific.

CIP Exemplary objects The following group of objects is Identity object Mandatory Attributes: Vendor ID Device Type Product Code Revision Status Serial Number Product Name Optional Attributes: State Configuration Consistency Value Heartbeat Interval Languages Supported Application-specific object: - AC/DC Drive - Analog Group - Analog Input Group - Analog Output Group - Analog Input Point - Analog Output Point - Block Sequencer - Command Block - Control Supervisor - Discrete Group - Discrete Input Group - Discrete Output Group - Discrete Input Point - Discrete Output Point - Group - Motor Data - Overload - Position Controller - Position Controller Supervisor - Position Sensor - Presence Sensing - S-Analog Actor - S-Analog Sensor - S-Device Supervisor - S-Gas Calibration - S-Partial Pressure - S-Single Stage Controller - Safety Supervisor - Safety Validator - Softstart Starter - Trip Point

CIP Device profiles Devices of similar functionality have been grouped into Device Types with associated profiles CIP profile contains the full description of the object structure and behavior: Communication networks, Objects Device profiles: AC Drives Device (0x02) Communications Adapter (0x0C) Contactor (0x15) ControlNet Physical Layer Component (0x32) ControlNet Programmable Logic Controller (0x0E) DC Drives (0x13) DC Power Generator (0x1F) Encoder (0x22) Fluid Flow Controller (0x24) General Purpose Discrete I/O (0x07) Generic Device (0x00) Human Machine Interface (0x18) Inductive Proximity Switch (0x05) Limit Switch (0x04) Mass Flow Controller (0x1A) Motor Overload Device (0x03) Motor Starter (0x16) Photoelectric Sensor (0x06) Pneumatic Valve (0x1B) Position Controller (0x10) Process Control Valve (0x1D) Residual Gas Analyzer (0x1E) Resolver (0x09) RF Power Generator (0x20) Safety Discrete I/O (0x23) Softstart Starter (0x17) Turbomolecular Vacuum Pump (0x21) Vacuum/Pressure Gauge (0x1C)

CIP connections Fig. 4.3. Multicast I/O connection [1] Fig. 4.4. Explicit connection [1] All connections on EtherNet/IP are established using a UCMM (Unconnected Message Manager) Forward_Open message When a connection is established, the transmissions associated with that connections are assigned a Connection ID (CID). If the connection involves a bidirectional exchange, then two Connection ID values are assigned

Explicit message exemplary configuration Explicit Message TAG is created on PLC 1 Request (write or read data) PLC 1 Client Response Message type TAG definition PLC 2 Server Message configuration

Explicit message connection configuration Explicit Message over Ethernet/IP must be: CIP Data Table Read PLC 1 reads data from PLC 2. CIP Data Table Write PLC 1 writes data to PLC 2. Destination (local) TAG on PLC 1 Read message Source (remote) TAG on PLC 2 Destination (remote) TAG on PLC 2 Write message Source (local) TAG on PLC 1

Implicit message exemplary configuration PLC 1 Consumer Consumed type TAG definition on PLC 1 Each RPI PLC 1 receives data from PLC 2 Consumer PLC 1 needs the data from Producer PLC 2 to be delivered periodically Implicit message can be either multicast or unicast PLC 2 Producer Produced type TAG definition on PLC 2

Producer TAG properties TAG name TAG type Maximum number of consumers

Consumer TAG properties TAG name TAG type Path to producer RPI value Data required by a consumer

Lesson Ethernet IP on Allen Bradley platform CoNeT Mobile Lab: Ethernet IP on Allen Bradley platform Introduction 1 Distributed control architecture 2 Real-time control system and real-time network 3 Monitoring and testing the Ethernet network 4 Introduction to EtherNet/IP technology 5 Introduction to laboratory: Description of laboratory and basic scenario 6 Software tools Co-operative Network Training 2011 Maciej Rosół, Department of Automatics, AGH University of Science and Technology

<5 Introduction to laboratory: Description of laboratory and basic scenario > 5.1 System architecture 5.2 Aerolift overview 5.3 Network structure 5.3 References Content of the lesson Ethernet IP on Allen Bradley platform

System Architecture Fig. 5.1. Schematic diagram of the laboratory setup Six nodes: 1. CompactLogix L35E PLC 2. POINT_IO: 1734-AENT 3. PowerFlex 40 inverter 4. WAGO 750-341 Coupler 5. Internet Camera (WebCam) 6. PanelView 600 Plus Touch Panel (now unused) Features: All nodes communicate via EtherNet/IP protocol All nodes are placed in a specially designed Allen- Bradley demo case PC is used as a development and Ethernet monitoring platform WebCam generates a noises in the network packet traffic <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

Compact Logix Controller 1769-L35E PLC CLC 1769-L35E is equiped with: CPU (Central Processing Unit) firmware revision 19.0, 1.5 MB internal memory, One RS232 serial port and one 100Mb/s EtherNet/IP port, Compact Flash card socket, Power supply Allen-Bradley 1769-PA2: input:120/240vac, output: 24VDC, Max. 30 local IO modules, EtherNet/IP Connections: 32 TCP/IP 32 CIP. Local I/O Modules: the Digital I/O module Allen-Bradley 1769-IQ6XOW4 (firmware revision 2.1 series B), the analog I/O module Allen-Bradley 1769-IF4XOF2 (firmware revision 1.1 series A), the terminal of the CompactBUS Allen-Bradley 1769-ERC. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

Compact Logix Controller 1769-L35E - local I/O Modules Table 5.1. The main parameters of the CompactLogix L35E local I/O modules 1756-ENBT 1769-IQ6XOW4 1769-IF4XOF2 Interface for a ControlLogix controller to communicate with other devices over an EtherNet/IP network, Adapter for 1756 I/O modules, Web server to provide diagnostic and status information, Communication via produced/consumed tags and MSG instructions. 6 digital inputs 24V DC (sinking/sourcing), operating voltage range 10 to 30 V, 4 digital outputs 24V relay (AC/DC), operating voltage range 5 to 265V AC and 5 to 125V DC I/O diagnostic LEDs. 4 analog inputs (differential or single-ended), analog normal operating ranges: voltage 0-10V, current 0-20 ma, resolution: 8-bits plus sign, response time: 5 ms/channel, 2 analog outputs (single-ended), analog normal operating ranges: voltage 0-10V, current 0-20 ma, resolution: 8-bits plus sign, response speed: 0.3 (resistance, inductor), 3 ms (capacitance). <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

Compact Logix Controller 1769-L23E The 1769-L23E CompactLogix system is a packaged controller for smaller, machine-level control applications. PLC CLC 1769-L23E is equiped with: CPU (Central Processing Unit) firmware revision 19.0, 512 kb internal user memory, Max. 128 I/O points, One RS232 serial port and one 100Mb/s EtherNet/IP port, EtherNet/IP Connections: 8 TCP/IP 32 CIP, 16 DC inputs: 24VDC, 16 DC outputs: 24VDC, Max. 3 local IO expansions. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

POINT_IO Modules Table 5.2. Parameters of the distributed POINT_IO modules 1734-AENT 1734-IB8 1734-OB4E Serves as a bridge between POINT I/O modules and the Ethernet/IP network, Provides communication for CompactLogix, ControlLogix controllers (supports of connections from multiple controllers simultaneously), Communication via produced/consumed tags, EtherNet/IP messages encapsulated within standard TCP/UDP/IP protocol, Half/full duplex 10 Mbit or 100 Mbit operation (RJ-45, interfacing via category 5 rated twisted pair cable). 8 digital inputs module: 24 V DC, sink, Operating voltage range: 10 28.8 V DC. Allows input filter time in the range of 0 63 ms. 4 digital outputs module: 24 V DC, source, Output current rating max. 1 A/channel, Outputs are not isolated, Operating voltage range: 10 28.8 V DC. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

POINT_IO Modules Table 5.2. Parameters of the distributed POINT_IO modules 1734-IE2V 2 analog inputs module. Operating ranges voltage: -10... +10 V. Input resolution: 15-bits plus sign ( 32,768...+32,767), 1734-OE2V The module produces 6 bytes of input data and fault status data: 2-bytes data/channel, 1-byte status/channel, Operates in unipolar or bipolar mode. 2 analog outputs module. Output voltage signal range: 0... +10 V or -10... +10 V, Output resolution: 13-bits plus sign ( 32,768...+32,767), The module consumes 4 bytes of output data: 2-bytes/channel, The module produces 2 bytes of fault status data: 1- byte/channel, Operates in unipolar or bipolar mode, 20µs conversion rate. 1734-VHSC24 Very High Speed Counter module: 24V, Accepts feedback from an encoder (either single ended or differential), pulse generators, or mechanical limit switches at frequencies up to 1 MHz, Allows filtering with four settings (50Hz, 500Hz, 5kHz or 50kHz). <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

Allen-Bradley PowerFlex 40 AC Main features of the PowerFlex40 AC drive: Integral keypad for simple operation and programming, 4 digit display with 10 LED indicators for display of drive status, Communication with PC using the RS-485 interface, Ethernet/IP (also DeviceNet, PROFIBUS DP, LonWorks and ControlNet interface are available), Autotune allows to adapt to individual motor characteristics, Sensorless Vector Control provides exceptional speed regulation and very high levels of torque across the entire speed range of the drive, Built-in PID cotroller, Timer, Counter, Basic Logic and StepLogic functions, Built-in digital and analog I/O (2 analog inputs, 7 digital inputs (4 fully programmable), 1 analog output, 3 digital output), Easy set-up over the network (RS NetWorx property). <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

PanelView Plus 600 & EtherNet/IP Configuration Works as an operator interface, Works under Windows CE operating system, Communication via Ethernet interface, Has possibilities in data presenting, trends and data collection, Visualization can be implemented using RSView Studio environment. The information required to configure the network: Parameters of the Ethernet network: IP address, Subnet mask, Gateway address. Types and parameters of the installed modules. Requested Packet Interval (RPI) time. The RPI is a common parameter configuration for all the modules connected to a network. It specifies the period at which data is updated over a connection. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

EtherNet/IP Configuration Configuration is performed using RSLinx and RSLogix 5000 software. Table 5.4. Ethernet/IP parameters of the laboratory setup modules CompactLogix PanelView 1734-AENT PowerFlex40 CompactLogix L35E Plus 600 L23E IP Address 192.168.1.1 192.168.1.2 192.168.1.3 192.168.1.5 192.168.1.10 Subnet Mask 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 Gateway IP Address none none none none none <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.1 System architecture> Slide 1-10/29

Aero-Lift Test Rig AGH Aero-Lift 4 floor building model. Sensors meassure the cart position and detect the cart motion. High level control automata that have 8 inputs and one output. PLC Sensors AC Motor Fig. 5.2. Aero-Lift - laboratory test-rig Pipe Cart <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Aerolift Overview> Slide 1-10/29

Aero-Lift Test Rig a) F4 Proximity sensors b) A proximity sensor is a sensor able to detect the presence of nearby objects without any physical contact F3 F2 F1 Cart Blower F1 S1t S1b Fig. 5.3. Aero-Lift test rig: a) system overview, b) floor configuration A blower is supplied by 3-phase drive controlling from the PowerFlex inverter <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Aerolift Overview> Slide 1-10/29

Basis of the PLC controller PLC controller is an industrial computer, which works under the real time operation system. PLC Controller Analog/Digital Input Modules Sensors PLC program CPU RAM/ROM Memories Fig. 5.4. Components of the PLC system Analog/Digital Output Modules Actuators <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Basis of PLC> Slide 1-10/29

PLC operating cycle Reading inputs, outputs and times Fieldbus data, Data of I/O modules PLC cycle RUN PLC program in the RAM is processed Writing outputs Operating system functions, updating times Operating mode? STOP The completion of one cycle of this sequence is called a scan Fieldbus data, Data of I/O modules System diagnostics, communications, Time calculations <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Basis of PLC > Slide 1-10/29

Real-time network structure The presented structure can be used to demonstrate the performance of the Ethernet/IP protocol and observe propagation time delays between sensor - remote controller and remote controller - actuator. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Real-time network structure> Slide 1-10/29

Configuration User Interface Aero-lift the dynamical system sensitive for sampling time and latency in data transmission Fig. 5.4 User Configuration Interface <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Aerolift Overview> Slide 1-10/29

Real-time network structure What are the parameters deciding about a network control system quality and performance? 1. Scan time of a PLC. 2. Period time of an implemented Periodic Task. 3. Requested Packet Interval (RPI) time. 4. Latency in a data transmission. Possible problems to be solved on the laboratory setup: 1. Analyzing an influence of the sampling frequency and/or the RPI on the AeroLift stability and controllability. 2. Determination of a propagation time delays between sensor-remote controller and actuator in the Ethernet/IP network based on packet analysis. 3. Analyzing an influence of the latency time, observable as a jitter in the data delivery, on performance and quality of the control network system (to diagnose these effect the WireShark application can be used). <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.2 Real-time network structure> Slide 1-10/29

References [1] Allen Bradley, RSLogix5000. Programming Software, Version 16.03 [2] Allen Bradley, RSLinx Classic. Getting Results Guide, PUBLICATION LINX-GR001G-EN-E, September 2010. [3] Allen Bradley, Logix5000 Controllers I/O and Tag Data. Programming Manual, Publication 1756-PM004A-EN-P, July 2007. [4] WAGO Kontakttechnik GmbH & Co. KG, 750-341 Modular ETHERNET TCP/IP I/O-System. User s Manual, Ver. 1.1.1, Germany, 2007. [5] WAGO Kontakttechnik GmbH & Co. KG, Using the WAGO 750-341 as Remote I/O with a ControlLogix Ethernet/IP Bridge Module, Application Note, Germany, 2004. <5 Introduction to laboratory: Description of laboratory and basic scenario> <5.3 References> Slide 1-10/29