This guide covers the basic operation and use of your PCAN-Diag FD. You can find a detailed documentation in PDF format...

Similar documents
PCAN-Diag FD Mobile Diagnostic Device for CAN and CAN FD Busses. User Manual. Document version ( )

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

PCAN-Flash Windows-Software for Flashing Firmware via CAN. Operation Instructions. Document version ( )

PCAN-Gateway Quick Start Guide

PCAN-B10011S Bus Converter High-speed CAN to Truck-Trailer CAN. User Manual V2.0.0

PCAN-Diag 2 Handheld Device for CAN Bus Diagnostics. User Manual. Document version ( )

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual. Document version ( )

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

PCAN-cPCI CAN Interface for CompactPCI. User Manual. Document version ( )

PCAN-PCI Express CAN Interface for PCI Express. User Manual. Document version ( )

PCAN-PCI/104-Express CAN Interface for PCI/104-Express. User Manual. Document version ( )

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual V1.0.1

PCAN-Diag 2 Handheld Device for CAN Bus Diagnostics. User Manual V2.3.1

PCAN-PCI Express FD CAN FD Interface for PCI Express. User Manual. Document version ( )

PCAN-LIN Interface for LIN, CAN, and RS-232. User Manual. Document version ( )

PCAN-ExpressCard CAN Interface for the ExpressCard Slot. User Manual. Document version ( )

PCAN-MiniDiag FD PCAN-MiniDiag Diagnostic Device for CAN FD FD Buses. User Manual. Document version ( )

PCAN-ExpressCard 34 CAN Interface for the ExpressCard/34 Slot. User Manual. Document version ( )

PCAN-Diag 2 Handheld Device for CAN Bus Diagnostics. User Manual V2.0.0

PCAN-PCI Express PCI Express to CAN Interface. User Manual V3.2.0

PCAN-B10011S. Converter High-speed CAN to Truck Trailer CAN. User Manual

PCAN-PCI/104-Express PCI/104-Express to CAN Interface. User Manual V2.1.0

PCAN-PCI PCI to CAN Interface. User Manual V2.1.0

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

PCAN-USB FD CAN FD Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-cPCI CompactPCI to CAN Interface. User Manual V2.0.0

PCAN-miniPCIe FD CAN FD Interface for PCI Express Mini. User Manual. Document version ( )

PCAN-PC Card PC Card to CAN Interface. User Manual V2.1.1

PCAN-ExpressCard ExpressCard to CAN Interface. User Manual V2.0.0

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-Explorer 6. Tel: Professional Windows Software to Communicate with CAN and CAN FD Busses. Software >> PC Software

PCAN-PC/104 CAN Interface for PC/104. User Manual V2.2.3

PCAN-Repeater 2-Channel CAN Repeater with galvanic isolation. User Manual V1.0.0

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

PCAN-M.2 CAN FD Interface for M.2 (PCIe) User Manual. Document version ( )

PCAN-PCI Express. PCI Express to CAN Interface. User Manual

PCAN-PCI Express PCI Express to CAN Interface. User Manual V2.0.0

PCAN-USB X6 CAN FD Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-MicroMod Mix 3 Application-specific PCAN-MicroMod Motherboard. User Manual V2.1.0

PCAN-USB Pro FD CAN FD and LIN Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

PCAN-PCI. PCI to CAN Interface. User Manual

PCAN-USB Pro CAN/LIN Interface for High-Speed USB 2.0. User Manual. Document version ( )

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual V1.1.0

PCAN-PCI (ISO) Adapter Card PC-PCI to High-speed CAN. User Manual

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-Dongle. Parallel Port to CAN Interface. User Manual

User Manual. CANopenIA-M0. Starter Kit

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

PCAN-Dongle. User Manual. Parallel Port to CAN Interface. Document version ( )

Wireshark Dissector for PCAN-Gateways IPEH , IPEH ,IPEH (A) User Manual. Document version 1.0 ( )

User Manual. HOPPECKE sun powerpack premium. service software

PCAN-Router. Universal CAN Converter. User Manual

PEAK-System Technik. New products for 2010 / Accessories

CANcheck. Installation Tester for CAN/CANopen Networks MANUAL ENGLISH

DIAGNOSTICS PN# / / FSP

Product End-of-Life Announcement Portable Data Recorder HMG 3010

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

PCAN-Wireless Gateway CAN to WLAN Gateway. User Manual. Document version ( )

PCAN-Router Universal CAN Converter. User Manual V1.2.0

WinFlash2 & USB Flash Prommer/SimLock

PLIN-Slave Test-Slave for the LIN Bus with Various I/Os. User Manual V1.1.0

PEAK-System Product Overview

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

LPMS-CU2 Quick Start Guide ver. 1.2

USB 3.0 Docking Station

Manual Lindab Analysis. PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function. Art. n.

LogicStudio Training Guide

User Manual MHD44. HDMI Matrix Switcher. All Rights Reserved. Version: MHD44_2014V1.0

Service tool HENRI. Technical Documentation. Short reference guide for proceeding internal HENRI functions JMo/Roe Version 2.0 KA.

BNI USB A501. USB IO-Link Master User's Guide. english

PEAK-System Product Overview

USER MANUAL. IST channel speed calibrator

CarScope VISO Getting started manual DITEX. CarScope VISO. Getting started manual

Manual Light Driver 5.0

User Manual MHD44. HDMI Matrix Switcher. All Rights Reserved. Version: MHD44_2014V1.0

Product description Rev. 3 11/06/14

PCAN-PassThru API. User Manual. Pass-Thru API and Connection of Pass-Thru Software to PEAK CAN Interfaces. Document version 1.1.

1. Introduction P Package Contents 1.

SPORTY - First start guide & useful hints MAYAH Communications

Technical Information Memobase Plus CYZ71D

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

DSC-N114_Network_Video_Recorder

iscan USB User Manual

USB 2.0 PRINT SERVER Quick Installation Guide

mobilecam GM-GV3 mobilecam & Viewer Software User Guide

UserGuide_TempSensor_with_Alarms Issue 4/

BYOD-HUB-UT Install Guide

English 1. Package Contents. The package contains the following items. In case there is any missing or damaged item, contact your dealer immediately.

Serial to LANC Adapter User s Guide

nüvi 3700 series quick start manual for use with these nüvi models: 3750, 3760, 3790

Analog DECT Phone AGR-8206-SMK. Quick Installation Guide V 1.01

PCAN-Router Pro 4-Channel CAN Router with Data Logger. User Manual. Document version ( )

Operation Manual Locator Wöhler L 200

Amcrest Eco HDCVI DVR Quick Start Guide

Transcription:

PCAN-Diag FD Quick Start Guide This guide covers the basic operation and use of your PCAN-Diag FD. You can find a detailed documentation in PDF format...... on the PCAN-Diag FD memory card in the directory: PCAN-Diag FD\Documentation.... on the supplied product DVD in the directory: Tools\PCAN-Diag FD\Documentation.... on our website. See the last page of this quick start for download links.

Connectors Display connector (Micro-HDMI)... to display the screen signal with an external monitor or beamer. CAN connector (D-Sub)... for connecting a High-speed CAN bus. PC connector (USB)... for configuring the device with the software PCAN-Diag FD Editor and for accessing the memory card. Lock switch... for securing the device for transport. If the switch is on the left on Locked, the device cannot be switched on. Voltage supply... 12 V DC (9-28 V possible). GND socket (4 mm)... for establishing a separate ground connection between the PCAN-Diag FD and the device under test. Trigger output (4 mm)... for providing the oscilloscope trigger signal for external measurement devices. Operation Voltage Supply Set up the voltage supply with the included AC adaptor. Apply the appropriate plug adaptor to the AC adaptor (Euro, U.S., or UK). For mobile use, the PCAN-Diag FD can be supplied via the internal rechargeable batteries. Charging is carried out with external supply, even during operation. Switching On and Off Set the Lock switch on the rear of the device to the position Ready. Hold down the push dial for at least half a second to switch on the device. Select Power Off from the main menu or hold down the push dial for at least 10 seconds to switch off the device.

Operating the Device The operation is done primarily with the push dial: Dial: Changes the selection or the value to be edited. Press: Executes the selected function or sets the adjusted value. The functions of the four hotkeys vary and are indicated on the display beside the control panel. CAN Connection Connect the PCAN-Diag FD to a CAN bus via the CAN connector (D-Sub) on the rear of the device. To successfully establish a connection, the CAN configuration of the PCAN-Diag FD must match the parameters of the connected CAN bus. In the Settings area you can adjust the necessary settings. CAN protocol Configuration of the CAN protocol to be used. Allow bit rate switch Allows transmission of the data part of CAN messages with the higher data bitrate if using the CAN FD protocol. Bit Rate Configuration of the bitrates via preconfigured profiles (CAN Bit Rate Presets) or selection lists: Clock: The possible bitrates derive from the selected clock frequency. Nominal Bit Rates: With the nominal bitrate, the bitrate of the CAN communication is set. Data Bit Rates: If using the CAN FD protocol, a higher bitrate for the transmission of the data part of CAN messages is set with the data bitrate. Please note: With Detect CAN bit rate the bitrates can be determined automatically. This function requires data traffic on the CAN bus between at least two nodes.

Receiving and Transmitting Messages Displaying Incoming CAN Messages Navigate to the menu item CAN Data > CAN Message View. Incoming CAN messages are displayed as a list, sorted by the CAN ID (column RxID). The representation of the CAN data bytes (Data 0...N ) is in hexadecimal format. Each occurrence of a CAN message increments its Count. Creating and Transmitting CAN Messages Navigate to the menu item CAN Data > CAN Message View. With the View function you can display the transmit list (table with the column TxID). Creating a CAN message Select the transmit list by rotating and pressing the push dial. Open the context menu with the MENU hotkey and choose Add. Enter the parameters for the new CAN message. Save the message with the OK hotkey. This closes the dialog and the new CAN message appears in the transmit list. Transmitting a CAN message Select a CAN message from the transmit list. You can start or stop the periodic transmission by pressing the push dial. With the SEND hotkey, you can transmit the message manually once.

Oscilloscope Function In order to analyze incoming signals with the oscilloscope function, select Scope from the main menu. If needed, you can adjust the configuration of the oscilloscope in the Settings area. Trigger View Export Selection of the event that triggers the sampling of the signals (e.g. start or end of a CAN frame, CAN ID, CAN error, or bitrate switch of a CAN FD frame). In this section, you can customize the signal sources to be displayed. In this section, you can configure which data will be saved on the memory card when using the Export function. After confirming the settings with the SAVE&OK hotkey, you can start the sampling. Single Run/Stop Triggers a single sampling of the signal. Starts and stops the repeated sampling of the signal. The presentation of the signal course can be manipulated via menu functions. Zoom H-pos. Zooms in or out. Moves the visible section horizontally. Device Configuration with Projects The PCAN-Diag FD can be adapted quickly to different application scenarios. The device settings and required files are set up in form of projects with the Windows software PCAN-Diag FD Editor; afterwards the projects are transferred to your PCAN-Diag FD via USB. You can find the program (PcanDiagFdEdt.exe)...... on the PCAN-Diag FD memory card in the directory: PCAN-Diag FD\Tools.... on the supplied product DVD in the directory: Tools\PCAN-Diag FD\Tools.... on our website. Detailed instructions about the creation of and the work with projects can be found in the PCAN-Diag FD user manual or in the PCAN-Diag FD Editor software help.

Documentation Simplified EU Declaration of Conformity PEAK-System Technik GmbH declares: The product PCAN-Diag FD (IPEH-003069) is in compliance with the EU EMC Directive 2014/30/EU. The full text of the EU declaration of conformity is available in the PCAN-Diag FD documentation. With these links you can get the documentation from our website. Documentation German (pdf) Documentation English (pdf) www.peak-system.com/ quick/doc3069d www.peak-system.com/ quick/doc3069e Updating the Firmware Keep your PCAN-Diag FD up-to-date. The PCAN-Diag FD package is available for download on our website. It contains the latest firmware, documentation, device help, and software. Download the latest PCAN-Diag FD data package from our website or directly with the following link to your PC. Unpack the data package. Make sure that the PCAN-Diag FD is supplied externally. Connect your PCAN-Diag FD to the PC. For this, use the supplied USB cable and activate the USB connection via the main menu item USB Connection. Update the data on the memory card. The new firmware file (*.bin) must be saved to the directory /PCAN-Diag FD/Firmware/. End the USB connection. Navigate to the menu item Support > Update Firmware. Select the new firmware (*.bin) from the list to start the update. As soon as the process is completed, the device switches off. Download Package (zip) www.peak-system.com/ quick/dlp3069