VersaMax IP I/O Module

Similar documents
VersaMax IP Input Module

GFK-2415A March Type of sensor connection

VersaPoint I/O Module

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IB IL 24 DI 16 IB IL 24 DI 16-PAC

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

VersaMax IP. Proficy Machine Edition. Publication Reference Chart

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

IBS IL 24 BK RB-T-2MBD

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Rexroth RECO Fieldline INTERBUS Devices

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

AXL E PB DIO16 M12 6P

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

RSTI-EP Slice I/O. Digital Output Module

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

IB IL IB IL PAC

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

8 24 V DC, 8 24 V DC,

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

VAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves

DPO A4. Description. Module with 4 digital outputs. Datasheet

AXL E IOL AO1 U M12 R

General information. Display. Supply voltage

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

AS-i Safety Input Modules (M12), IP67

IndraControl S67. Fieldbus coupler PROFINET

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Data sheet CPU 115 (115-6BL02)

Communication modules. Serial interface module

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

Data sheet CC 03, Commander Compact (603-1CC21)

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

GE Intelligent Platforms. Programmable Control Products. VersaMax* IP. Installation Manual, GFK-2307B

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

Data sheet VIPA CPU 115DP (115-6BL22)

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

General information. Display. Supply voltage

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

FL MC 2000E (SM40) LC

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

General information. Display. Supply voltage. Input current

IBS ST (ZF) 24 BK LB-T

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

General information Engineering with Programming package. Display with display

TM221CE24R controller M IO relay Ethernet

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Digital I/O modules. 8 inputs/outputs, M8

TM221CE40R controller M IO relay Ethernet

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

KeConnect I/O modules

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ILC 200 IB ILC 200 IB-PAC

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

BMX DDM Mixed Relay Input/Output module

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM241C40R controller M IO relay

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

General information. Display. Supply voltage. Input current

Overview. Application. Function. Technical specifications. Home

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

Transcription:

Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001) / PROFINET Interface Unit (IC677PNS001). Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 70mm x 178mm x 49.3mm (2.756in. x 7.008in. x 1.941in.) 2-, 3-, and 4-wire sensors, 2- and 3- wire actuators -25 C to +60 C (-13 F to +131 F) -25 C to +85 C (-13 F to +185 F) 95%. Slight condensation is permitted occasionally on the outer housing, for short periods. Degree of protection IP67 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Module Power Nominal value 24VDC Tolerance +/-25% Current consumption U L at 24VDC Features Connection to digital sensors and actuators using M12 connectors Flexible voltage supply Diagnostic and status indicators Short-circuit and overload protection of outputs and sensor supply IP67 protection Ordering Information At 500kbaud At 2 Mbaud Current consumption U S at 24VDC Current consumption at U AXX at 24VDC 40mA typical, 50mA: maximum 45mA typical, 50mA: maximum 5mA typical plus sensor current 600mA maximum 3mA typical + actuator current (4A maximum) Module with 4 Inputs and 4 Outputs IC676ACC001 VersaMax IP Point Labels, qty 50 IC676ACC002 Protective Caps. Male, for unused I/O connectors and/or outgoing bus and power connectors, qty 5 IC676ACC003 Protective Caps, Female, for unused incoming power connections, qty 5 1

Module Dimensions Internal Circuit Diagram Functional earth ground Optocoupler Power Supply with electrical isolation input LED (status indicators) Output Isolated area 2

Module LEDs D Green LED Diagnostics Bus active Flashing 0.5Hz Flashing 2Hz Flashing 4Hz Communications power present but bus not active Communications power present and bus active, I/O error Communications power present but device to the left of the flashing device failed or devices to the right of the flashing device are not configured Communications power not present and bus not active US Green LED Voltage supply for the inputs Voltage supply present Voltage supply too low E Red LED Overload of Voltage Supply U S Voltage supply overloaded Voltage supply not overloaded XX Yellow LEDs Input Status Indicators Input active Input not active YY Yellow LEDs Output Status Indicators Output active Output not active ZZ Red LED Overload of the Outputs Output overloaded Output not overloaded UA11 Green LED Voltage supply for Outputs 1 and 2 Voltage supply for outputs 1 and 2 is present Voltage supply for outputs 1 and 2 is too low UA12 Green LED Voltage supply for Outputs 3 and 4 Voltage supply for outputs 3 and 4 is present Voltage supply for outputs 3 and 4 is too low 3

Module Connectors Connector FE LB IN LB OUT U LS IN U LS OUT Function Functional earth ground Local bus In Local bus out Voltage supply in (logic and sensor supply) Voltage supply out (logic and sensor supply) for additional modules IN1 to IN4 Inputs 1 to 4 OUT1 to OUT4 Outputs 1 to 4 U A IN Voltage supply IN of the outputs (OUT1 to OUT4) with voltages U A11 and U A12 U A OUT Voltage supply OUT of the outputs for other devices Connection Guidelines Meet Noise Immunity Requirements. Connect FE using a mounting screw, or on a non-conductive surface using a cable connection to the FE connection point. Ensure IP67 Protection. Cover the unused sockets with protective caps (IC676ACC002 and ACC003). Avoid Damage to the Electronics. Supply the sensors with the appropriate voltage U S at the connection points. In general, the maximum current load of 4A per contact must not be exceeded. Avoid Polarity Reversal of supply voltages U L, U A and U S. Connect sensors to correct points (shown on next page). Local Bus Pin Assignments M12 B-encoded Pin Bus In Bus Out 1 DO DO 2 DO DO 3 DI DI 4 DI DI 5 GND GND The thread is used for shielding. 4

Pin Assignment of the Voltage Supply Pin In Out 1 U L +24V U L +24V 2 U S GND U S GND 3 U L GND U L GND 4 U S +24V U S +24V 5 500 kbaud / 2 MBaud 500 kbaud / 2 MBaud The transmission speed is switched at the Bus Interface Module Pin Assignment of the Voltage Supply at the Outputs Pin In Out 1 U A11 +24V U A11 +24V 2 U A12 GND U A12 GND 3 U A11 GND U A11 GND 4 U A12 +24V U A12 +24V 5 Not used Not used Pin Assignment of the Inputs and Outputs Pin Input Socket Output Socket 1 US +24V Not used 2 See input socket assignments below Not used 3 GND GND 4 Input Output 5 FE FE Input Socket Assignments Two input signals can be connected to each input socket. If both inputs of the same socket are used, the other socket must not be used (1 or 2, and 3 or 4, as shown at left). 5

Connection Example Program Data ID number Input address area Output address area BF hex (191 decimal) 4 bits 4 bits Process I/O Data Format This module provides 4 bits of input data and receives 4 bits of output data. Connection points are assigned to these bits as shown below: Bit Number 3 2 1 0 Input 4 3 2 1 Bit Number 3 2 1 0 Output 4 3 2 1 6

Technical Data Discrete Inputs Number 4 Switching thresholds Nominal input voltage U IN Range Nominal input current U IN Current flow Delay time Permissible cable length to the sensor Input Characteristic Curve Input voltage (V) <5V maximum low voltage level >11V minimum high voltage level 24VDC -30V < U IN < +30VDC 5mA Linear in the range 2V < U IN < 30 V On: 3.1 ms typical Off: 4.1ms typical Up to 30m (98.43ft)) Typical input current (ma) -30 < U IN < 0.7 0 3 0.5 6 1.0 9 1.6 12 2.3 15 3.0 18 3.8 21 4.5 24 5.2 27 6.0 30 6.7 Sensor Supply Minimum sensor voltage Nominal current per channel Nominal current per module Overload Protection Short-circuit protection U S - 1V 600mA 600mA Electronic per module Electronic per module Input Error Messages Short circuit of sensor supply Overload of sensor supply Yes Yes. If an error is triggered by an overload or short circuit of the sensor supply, the module switches off the sensor supply of the channels and reports a peripheral fault. Local Bus Interface Transmission speed, incoming and outgoing Shield connection, incoming and outgoing 500 Kbaud / 2 Mbaud Direct to FE 7

Discrete Outputs Number 4 Nominal output voltage U OUT U AXX 1V Differential voltage for I NOM Nominal current I NOM per channel Total current Up to 1V 2A 8A. If all outputs are on at the same time, maximum temperature is derated as shown: Protection At ambient temperatures of 45 degrees C (113 degrees F) or above, voltages U L and U S at socket U LS OUT can each carry a maximum current of only 2A. All channels are thermally-isolated. An error in one channel can affect the other channels. The outputs have separate overload protection. Nominal load per channel Ohmic: 48W Inductive: 48VA (1.2H, 12 Ohms) Lamp: 48W Signal delay at powerup Signal delay at power down Approximately 140µs, typical Approximately 3.4ms, typical Switching frequency with: Nominal Ohmic load: 500Hz maximum * Nominal Inductive load: 0.1Hz (1.2H, 12 Ohms), maximum Nominal Lamp load: 500Hz maximum Overload response Restart frequency with ohmic overload (2 Ohms) Response with inductive overload Reverse voltage protection against short pulses Resistance to permanently-applied reverse voltages Response upon power-down Validity of the output data after power up Limitation of the voltage induced on circuit interruption Single maximum energy in free running Protective circuit type Overcurrent shutdown Output current when switched off Output current with ground connection interrupt when switched off Cable length to the actuator * Depends on number of bus devices, bus structure, and control system Automatic restart 45Hz approximately Output may be damaged Yes No The output follows the supply voltage without delay 5ms, typical -11V approximately 1500W Integrated free-wheeling diode for each channel 2.6A, minimum 20μa, maximum 5mA maximum Up to 30m (98.43 ft) 8

Output Characteristic Curve when Switched On (Typical) Output Current (A) Differential Output Voltage (V) 0 0 0.20 0.01 0.40 0.03 0.75 0.05 1.00 0.07 1.50 0.12 1.75 0.13 2.00 0.17 Output Characteristic Curve for Ground Connection Interrupt (U Axx = 30VDC) Load Resistance (K Ohms) Output Error Messages Overload of outputs Output Voltage (V) 29.9 1000 28.8 100 25.0 10 13.6 1 3.8 Yes. If an error is triggered at the outputs due to an overload, the module switches off the corresponding output and sends an error message. Isolation, Test Distance 24V supply (bus logic) / FE 24V supply (bus logic) / digital inputs (sensor supply / I/O) 24V supply (bus logic) / digital outputs (actuator supply) 24V supply (bus logic) / local bus Digital inputs (sensor supply) / I/O) / FE Digital inputs (sensor supply) / I/O) / digital outputs (actuator supply) Digital inputs (sensor supply) / I/O) / local bus Digital Outputs (actuator supply) // FE Digital outputs (actuator supply) / local bus Local bus / FE Test Voltage 9