XT IEC Power Control Contactors, Starters and Overload Relays

Similar documents
IEC Contactors & Starters XT IEC Power Control

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Large Frame IEC Contactors

Allen-Bradley Bulletin 100 Contactors

Mini Contactors & Overloads

Contactors and Contactor Assemblies

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Power Control Contactors and Contactor Assemblies

CS7 Industrial Control Relays

TeSys IEC Contactors and Overload Relays

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Contactors and Contactor Assemblies

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

3RT, 3TB, 3TF Contactors for Switching Motors

CS8 Industrial Control Relays

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Table of Specifications

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Micro Contactor MA Series

Allen-Bradley 700-K40E-DJ

3 Pole Contactors with AC operating coils

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Series CA7 Contactors

3RA13, 3RA14 Contactor Assemblies

194E FA 32 E P11 P11 6

CS7 Industrial Control Relays

Controls Enclosed Non-Combination Starters - PESW Series

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Motor protection relays

EU Declaration of Conformity

TeSys contactors From 115 to 2750 A

EU Declaration of Conformity

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

EU Declaration of Conformity

C E R T I F I C A T E O F C O M P L I A N C E

C 2 5 D N A A A

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

IEC Contactor Specifications

Series CA9 Contactors

Protection Equipment

Contactors and Contactor Assemblies

Cert.Record No _C_000, Class No , DQD No 548 Rev

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

RiLine Compact The smart power distribution system

Miniature Circuit Breakers and Supplementary Protectors. Contents

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

EC Declaration of Conformity

Controls Contactors and Contactor Assemblies

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Allen-Bradley Drives

78 Series Electromechanical Relay Selection Guide

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Solid-State Contactors

onlinecomponents.com

EU Declaration of Conformity

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

ITEM ESM-BA301

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

UL 489 DIN Rail Miniature Circuit Breakers

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Circuit Breakers Type CTI 25M, CTI 45MB

Features, Benefits and Functions

Series CA7 Contactors

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

Simply on. Simply off. Day and Night. sirius SWITCHING

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

Revolutionizing control wiring

Control, Timing + Ice Cube Relays

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Connectivity Solutions

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Connectivity Solutions

UL 489 DIN Rail Miniature Circuit Breakers

Ultra Slim Relays 24

K-Line Mini - Contactors, Overload Relays and Accessories

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Connectivity Solutions. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

UL 489 DIN rail branch circuit breakers

WMS SUPPLEMENTARY PROTECTORS

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Thermal Overload Relays. XT IEC Power Control

Pluggable interface relays CR-P Pcb relays

Bulletin 700-HA Tube Base Relay

Disconnect Switches. Safe Switching and Disconnecting

MOTOR CONTROL. Mini-Contactors and Thermal Overload Relays. SK Series 62C1-E-0022

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

Safe monitoring relays

Solid-State Switching Devices

Go to:

PRODUCT SPECIFICATION. PC Board Relays. Series.

Transcription:

May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........ 6 Non-reversing Starters, Bimetallic Overload........ 8 Reversing Starters, Bimetallic Overload........ 9 Non-reversing Starters, C96 Electronic Overload................. Reversing Starters, C96 Electronic Overload................. Star-Delta (Wye-Delta) Starters.................. Accessories................ 8 Renewal Parts.............. 8 Technical Data and Specifications............. 9 Dimensions................ 8 Reference Data............. 99 XT Family of Contactors Contactors and Starters Product Description Eaton s new line of XT Contactors and Starters includes non-reversing and reversing contactors, overload relays and a variety of related accessories. Because XT meets IEC, UL, CSA, CCC and CE standards, it is the perfect product solution for IEC applications all over the world. The compact, space saving, and easy to install XT line of IEC contactors and starters is the efficient and effective solution for customer applications from A to 000A. AC control from V to 0V 0/ Hz DC control from V to 0V Available with screw or spring cage terminals Reversing or non-reversing contactors and starters AC- contactor ratings to 00A and AC- contactor ratings to 000A Non-reversing starters to A Panel or DIN rail mounting to 6A IP0 finger and back-of-hand proof Large ambient temperature range, - to 0 C [- to F] AC and DC controlled contactors in the same compact frame Low power consumption DC coils Built-in NO or NC auxiliary contacts to A Plug-in accessories for reduced installation time replacement on Frames C N (8 80A) Contact replacement on Frames D N (0 80A) Integrated suppressor A DC operated contactors and 8 000A AC and DC operated contactors Standards and Certifications IEC EN 9 CE Approved UL CSA CCC ATEX RoHS Note: For Type Coordination, see Page 99. CA0000E

0 Product Family Overview May 00 Table 6. Product Identification No. Description Page Contactor Up to A AC- AC: 0V, 0,, 0/ Hz 0.8. x U c DC: 0V XTCE B_ ( A): 0.8. x U c XTCE C_ XTCE G_ (8 A): 0.. x U c V: 0.. x U c at 0 C without additional auxiliary contacts s for Special Voltages Safe Isolation to IEC 6 between coil and contacts Suppressors RC suppressor Varistor suppressor Free-wheel diode suppressor Overload Relays Can be mounted directly Separate mounting, possible Protection of EEx e motors 9 Auxiliary Contact Modules -pole, plug-in type -pole, plug-in type Overlapping contacts -pole, side mounting 8 CA0000E

May 00 Product Family Overview 6 Table. XTCE8 XTCEC0 Contactors No. Description Page XTCE Contactors for 8 000A (AC-) Multi-Voltage s: 8V DC 8 V AC/DC 0V AC/DC 0 00V AC 0.. x U c Actuation Options: Directly From the PLC With low-consumption contact Minimized pick-up and sealing power. XTCS Contactors for 8 00A (AC-) Control Voltages: V 0/ Hz 0 0V 0/ Hz Conventional operation. Cable Terminal Block or conductors per phase Round and flat conductor connectable Finger-proof Flat Strip Conductor Terminals or strips per phase Control circuit terminal Cover for fingerproofing Mechanical Interlock Fits between contactors Overload Relays Can be mounted directly Separate mounting, possible Protection of EEx e motors PTB certificate 9 Terminal Shroud 6 Finger-proof Auxiliary Contact Modules -pole, side mounting 8 CA0000E

Catalog Number Selection May 00 Catalog Number Selection Table 8. XT IEC Contactors & Starters Catalog Numbering System X T C E C 0 0 B 0 A D P 6 Designation XT XT Line of IEC Control Type CE -Pole FVNR IEC Contactor CS -Pole FVNR S Series IEC Contactor CF -Pole FVNR IEC Contactor CR -Pole FVR IEC Contactor CC IEC Capacitor Contactor AE FVNR IEC Starter AS FVNR S-Series IEC Starter AR FVR IEC Starter Blank C Terminations Screw Terminals (6 6A); mm (80 A); No Lugs (8 000A) Spring Cage Terminals (6 A); Spring Cage Terminals Only (8 00A) Current Ratings, AC- 00 009 0 0 08 0 0 00 00 06 080 09 8 0 00 00 00 A 9A A A 8A A A 0A 0A 6A 80A 9A A A 8A A 0A 00A 00A 00A 80 80A A 0 0A 80 80A C 00A Frame Size Designation B mm 0 NC NO C mm D mm F mm G mm Built-In Auxiliary Contact 00 0NO-0NC L 0 mm M mm N 0 mm C 00A, AC- P mm C6 0A, AC- R mm C0 000A, AC- XTAE, XTAS and XTAR Starters Only Maximum Overload Relay XTOB Maximum Overload Rating Frame D P6 0. 0.6A P 0.6 0.A P0 0. 0.A P 0. 0.6A 00 0.6 A P6.0.6A P.6.A 00. A 006 6A 0 6 A 0 9 A 06 6A Frame C P6 0. 0.6A P 0.6 0.A P0 0. 0.A P 0. 0.6A 00 0.6 A P6.0.6A P.6.A 00. A 006 6A 0 6 A 06 6A 0 6 A 0 A 0. 0.A 0..0A A.6 8A 6. Frame C 0. 0.A 0..0A A.6 8A 6. A Frame D 6. A 9 A A Codes See Table. 0 6 A 06 6A 0 6 A 00 0A 0 0 A 06 0 6A Frame F 0 A 00 0A 00 0 0A 0 0 0A Frame G 0 A 00 0A 00 0 0A 0 0 0A 9 A A Frame L 00 0 0 0 0 0A 0 0A 9 A A 0A 00 0A C96 Maximum Overload Rating Suffix Std. Class //0/0 EP0 E00 E00 E008 E0 EP0 E00 E00 E008 E0 E0 E0 E0 Frame F A E Frame G 0 A E CA0000E

May 00 Non-reversing Contactors Table 9. Full Voltage Non-reversing -Pole Contactors, Frame G I e (A) I e I th Maximum kw Maximum -Phase Motor Rating, UL/CSA (A) Ratings AC- AC- 9 9.. Frame C 8 8 Frame D 0 0 6 Frame F 80 9 Frame G Underscore (_) indicates magnet coil suffix required. See Table, Page. For Spring Cage Terminals, insert C after the fourth digit of the Catalog Number. Example: XTCEC00BA. For A XTCEC Contactors, the power, auxiliary and coil terminals are spring cage. For 8 A XTCEC Contactors, the auxiliary and coil terminals are spring cage. For 0 A XTCEC Contactors, the coil terminals only are spring cage. For electrical life contactor application data, see Table, Page. Notes: AC- ( C) 0 0 0 0 0 0 0 0 0 0 0 0 0 6 80 Aux. Contacts Catalog Number Screw Terminals -Phase Motors 0 Hz -Phase hp Ratings -Phase hp Ratings AC 0/ 80/ V 6/ V 00V 0V 00V 0V V V 0V 00V 6V.......... 0 0 8...... 8. 0.. 8 8.. 8 8 0 9 8 0 9 Frame C Frame D Frame F G.... 6. 6. 0 6 96 / / / / -/ -/ / / -/ -/ -/ -/ 0 -/ -/ -/ -/ 0 0 0 -/ -/ 0 0 0 0 0 0 0 0 0 0 -/ -/ 0 0 0 0 0 NO NC NO NC NO NC NO NC NO NC NO NC NO NC XTCE00B_ XTCE00B0_ XTCE009B_ XTCE009B0_ XTCE0B_ XTCE0B0_ XTCE0B_ XTCE0B0_ XTCE08C_ XTCE08C0_ XTCE0C_ XTCE0C0_ XTCE0C_ XTCE0C0_ XTCE00D00_ XTCE00D00_ XTCE06D00_ XTCE080F00_ XTCE09F00_ XTCEG00_ XTCEG00_ Price U.S. $ 9. 9... 9. 9... 9. 9. 9. 9... 9. 8. 0. 88. 68. 8.. DC 6. 6... 6. 6... 80. 80. 08. 08. 9. 9. 0... 8.. 0.,. The A XTCE Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules. The 0 6A XTCE Contactors have positively driven contacts within the auxiliary contact module. 6 auxiliary contacts are possible with a combination of side mounted and front mount auxiliary contacts. DC operated contactors (Frames B G, A) have a built-in suppressor circuit. C contactors with NC built-in auxiliary are mirror contacts (XTCE...B0_ XTCE...C0_). Contact Sequence (Circuit Symbols)................... Page Voltage Chart.................... Page Accessories........................ Page 8 Dimensions......................... Page 8 Overload Relays..................... Page 9 Discount Symbol.................... CD CA0000E

May 00 Non-reversing Contactors Frame L Frame M Frame N Frame P Frame R Table 0. Full Voltage Non-reversing -Pole Contactors, Frame L Frame R I e (A) I e I th Maximum kw Maximum -Phase Motor Rating, UL/CSA (A) Ratings AC- AC- AC- ( C) Aux. Contacts Catalog Number Screw Terminals -Phase Motors 0 Hz -Phase hp Ratings -Phase hp Ratings AC 0/ 80/ V 6/ 00V V 00V 0V 00V 0V V V 0V 00V 6V Frame L Standard (/V, 0/0V AC Only) 8 0 0 0 Frame L Electronic 8 0 0 0 8 8 0 0 8 8 8 8 8 8 Frame M Standard (/V, 0/0V AC Only) 00 00 00 00 00 00 00 0 Frame M Electronic 00 00 00 00 00 00 Frame N Electronic 80 0 80 00 800 80 0 00 00 8 0 0 00 0 00 0 80 0 00 80 0 00 8 00 6 86 86 0 0 00 0 0 800 800 00 Frame P Electronic 00 XTCECP_,00. Frame R Electronic 0 800 00 0 0 0 00 0 0 XTCEC6R_ 6,. 000 XTCEC0R_,0. Underscore (_) indicates magnet coil suffix required. See Table, Page. For 8 00A Contactors at 6/6V or 00V: Do not reverse directly. When operating the 80 000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test see Pub, Pub9. 0 0 0 0 00 00 0 0 0 0 00 00 00 0 00 0 0 00 00 0 00 00 0 00 00 00 00 0 00 80 00 0 00 0 00 00 00 00 00 00 0 0 00 8 980 XTCS8L_ XTCSL_ XTCS0L_ XTCE8L_ XTCEL_ XTCE0L_ XTCS00M_ XTCS00M_ XTCS00M_ XTCE00M_ XTCE00M_ XTCE00M_ XTCE80N_ XTCEN_ XTCE0N_ XTCE80N_ XTCECN_ Price U.S. $,.,8.,00.,.,6.,0.,0.,68.,6.,0.,9.,.,.,. 8,.,.,. DC,.,6.,0.,0.,9.,. Table. Contactor Application Data Catalog Prefix AC- Electrical Life (Operations) XTCE0B A million XTCE0B A. million XTCE08C 8A million See Page 8 for Electrical Life Curves. Note: AC and DC operated contactors have a built-in suppressor circuit (Frames L R, 8 000A). Table. Full Voltage Non-reversing -Pole Contactors Contact Sequence (Circuit Symbols) Standard Offering Contactor Frame B C B C Auxiliary Contacts NO NC D G L R Contact Sequence A A 6 A A 6 A A 6 A A 6 Voltage Chart.................... Page Accessories......................... Page 8 Dimensions......................... Page 8 Overload Relays..................... Page 9 Discount Symbol..................... CD CA0000E

May 00 Table. Full Voltage -Pole Non-reversing Contactors with Screw Terminals I e (A) AC- Maximum kw Ratings AC- AC- -Phase Motors 0 Hz ( C) 0/ 0V 80/ 00V V 6/ 6V Maximum -Phase Motor Rating -Phase hp Ratings -Phase hp Ratings 00V V 0V 00V 0V V V Contact Sequence Catalog Number 0.. 6. / -/ -/ A XTCF00B00_. 69. Price U.S. $ AC DC Underscore (_) indicates magnet coil suffix required. See Table 8. A 6 8 Table. Controlling XTCS and XTCE Contactors Frame L R (8 000A) Description XTCS8L XTCS00M XTCEC6R, XTCEC0R XTCE8L XTCECP Conventional A/A are applied to voltage in the usual manner. (+) L (+) L (+) L A A A A A A A A A A A A A A TY TX A A A A Direct from the PLC A V output from the PLC can be connected directly to connections A/A. (+) L A A (+) L A A A A A A TY A A TX A A V GND V GND From Low-Consumption Command Devices Command devices which can only be subject to minimal loads such as circuit board relays, control circuit devices or position switches can be connected directly to A/A. (+) L A A A A (+) L A A A A TY TX A A A A Standstill in an emergency (Emergency-Stop). Command device connection. Discount Symbol....................... CD CA0000E