Applying branch circuit breakers and supplementary protectors in North America

Similar documents
Applying branch circuit breakers and supplementary protectors in North America

UL 489 DIN rail branch circuit breakers

Miniature Circuit Breakers and Supplementary Protectors. Contents

Bulletin 1489 Circuit Breakers. Selection Guide

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

WMS SUPPLEMENTARY PROTECTORS

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

60103 Circuit Breaker

Section 4 Ground-Fault Protection Devices

Circuit Protection Methods

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Control Circuit and Load Protection Products

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Solid-State Switching Devices

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

1492-SP Supplementary Protectors

MULTI 9 System Catalog

Application Techniques CENTERLINE 2100 Motor Control Centers

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

IELR Rail-Mount Series Magnetic Circuit Protectors

Selection Guide. Control Circuit and Load Protection

TeSys IEC Contactors and Overload Relays

UL 508 A standard-compliant design of industrial control panel

Selection Guide. Control Circuit and Load Protection

IELR Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Multi 9 System Catalog

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Miniature Circuit Breakers for Railway Applications

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

For Sales and Support call KMParts.com (866)

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

9926 Series Branch Rated Circuit Breakers AC Version

C E R T I F I C A T E O F C O M P L I A N C E

Panelboard and switchboards series rating information manual

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

SECTION SWITCHBOARDS

MULTI 9 System Catalog

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

UL 508A Industrial Control Panels Eaton. All Rights Reserved.

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Problem solver for the North American market: PKZM4-...-CB

1. Coordination of series-rated devices is permitted where indicated on Drawings.

EDR-3000 Eaton Distribution Relay

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

APL/UPL, 205/295 Series Magnetic Circuit Protectors

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Supplemental Protectors

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Introduction Circuit Protection

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

ASCO 920 Remote Control (RC) Switches

Solid-State Contactors

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Miniature Circuit-Breaker IEC Series 8562

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

IELR Rail-Mount Series Magnetic Circuit Protectors

SECTION PANELBOARDS

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

WHITE PAPER. Overload or Short Circuit Protection? How to protect your design against both dangers. E-T-A Circuit Breakers USA. E-T-A Circuit Breakers

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Motor protection relays

Protection Equipment

920 Remote Control (RC) Switches

Cutler-Hammer. January 2001

UL 489 or UL 1077 in control panels and equipment a quick guide

SECTION DISCONNECT SWITCHES

4. CIRCUIT BREAKERS. Functional Emergency Switching

Allen-Bradley Bulletin 100 Contactors

Requirements for machine approval in North America under the new NEC 2017

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Transcription:

Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North America. The first version, WMZT, fully complies with the Molded Case Circuit Breaker standard UL 489 and the Canadian equivalent CSA 22.2 No. 5-02, which states that devices within that range can be applied legitimately as Feeder and Branch Circuit Protective devices per the US and Canadian electrical Codes. A second version, WMZS, is recognized per UL 1077 and certified per CSA C22.2 No. 235 as a Supplementary Protector and can be fully utilized per the National Electrical Code (NEC ) and the Canadian Electrical Code (CEC) in that capacity. For international purposes, the entire WMZ family is CE marked and in full conformity with the applicable IEC standards for miniature circuit breakers, EN/IEC 60 898 and EN/IEC 60 947-2. Both WMZS and WMZT are offered in various ampere ranges and tripping characteristics. This paper will focus on the main technical aspects of the entire line and should assist in the proper selection and application of all versions.

Product Application AP01102005E Characteristics of IEC-style Miniature Circuit Breakers Because WMZ Miniature Circuit Breakers are IEC-style devices, it is important to understand their inherent characteristics before examining them in the context of UL / CSA requirements. IEC-style miniature circuit breakers are thermal-magnetic, inverse time protective devices, with both a fixed thermal and a fixed magnetic trip setting. They are toggle operated, and like all modern circuit breakers, feature a trip-free mechanism. This means that the tripping action works independently of the handle position for safety purposes. They all mount on a standard 35mm DIN-rail and share a common single pole width of 17.5 mm. Most comply with EN/IEC 60898 and EN/IEC 60947-2, which are the relevant international performance and testing standards for low voltage (<1000V) circuit breakers in Europe and the rest of the IEC world. Outside North America, they can be used in both residential and industrial applications as feeder and branch circuit protective devices. In North America, most European Miniature Circuit Breakers are only UL recognized and CSA certified as Supplementary Protectors, meaning they cannot be utilized as feeder or branch circuit protective devices per the local electrical codes. This commonly restricts their use to applications where closer protection is desired than that offered by a branch circuit protection device. Some variations, like the new WMZT line have been specially designed to meet UL and CSA requirements for Molded Case Circuit Breakers and are marked accordingly. This makes them suitable for feeder and branch circuit protection applications in North America. Supplementary Protectors As mentioned, the standard WMZS line fulfills all of the criteria per Code of Supplementary Overcurrent Protective Devices, or Supplementary Protectors, as they are better known. What is the definition of a Supplementary Protector per North American standards? A Supplementary Protector is a manual reset device designed to open the circuit automatically on a predetermined value of time versus current or voltage within an appliance or other electrical equipment. It may also be provided with manual means for opening or closing the circuit. (Source: UL 1077) In the US (and similarly in Canada) the NEC further defines supplementary protectors as devices intended to provide limited overcurrent protection for specific applications, such as lighting fixtures and appliances. This limited protection is in addition to the protection provided in the required branch circuit by the branch circuit overcurrent protective device. Clearly, the underlying message in those definitions is that Supplementary Protectors are not Branch Circuit overcurrent protective devices per Code, and neither are they tested that way per UL and CSA standards. They cannot replace the primary protective role performed by listed and certified molded case circuit breakers and fuses. That explains, in part, their status by UL as recognized only devices. Supplementary Protectors will never bear a UL listing mark, simply because their suitability as protective devices is dependent on a number of acceptability conditions which can vary from make to make and ultimately define the manner in which they can be properly applied per Code. The manufacturer should be consulted in all cases when evaluating the suitability of recognized only components such as UL 1077 Supplementary Protectors. WMZS protectors are not subject to any specific restrictions in this respect, other than, like all Supplementary Protectors, they must never be used as a substitute for true listed and certified primary overcurrent protective devices. Where can Supplementary Protectors be used effectively per Code standards? Eaton WMZS Supplementary Protectors can be used in a number of significant areas. To more clearly illustrate potential applications, however, let s first present the NEC s definition of a Branch Circuit: The circuit conductors between the final overcurrent device protecting the circuit and the outlets. (Source: NEC). A branch circuit is that portion of the electrical distribution system which extends beyond the final branch circuit overcurrent protective device and is intended to serve lighting, appliance, motors and/or other individual loads. Typically, the Branch Circuit Overcurrent Protective Device (BOPD) will be either a listed molded case circuit breaker or fuse. Supplementary Protectors, such as Eaton WMZS, can therefore be added to any of these branch circuits to supplement the branch circuit protection. Examples of applications ideally suited for these devices can include: Any type of OEM electrical equipment which is fed from a service panel board and which often requires additional protection for sensitive internal circuitry and components. (Test and medical equipment, copiers and printers, computers and power supplies etc.) The need for manual reset devices with optional accessories such as auxiliary contacts and voltage trips to accomplish fuseless protective circuit designs and enhance operational diagnostics. Isolation and protection of control cable, coils, contacts and circuit elements of motor control circuits tapped from the load side of the branch circuit protective device. Protection of control circuit transformers, especially in the secondary where the manual reset protector can be used to isolate, as well as protect, secondary circuit conductors and loads. Recognized only mark from UL All UL 1077 Supplementary Protectors are recognized only devices. They are subject to Conditions of Acceptability in order to be applied properly per the intent of the Electrical Codes. 2

Product Application AP01102005E IEC based miniature circuit breakers, such as the WMZS, are much more than just conventional supplementary protectors from an internal design point of view and can provide an ideal means to enhance the protective capabilities of any circuit. As mentioned, they are in full compliance with the pertinent EN/ IEC standards (EN/IEC 60898, EN/IEC 60947-2) for miniature circuit breakers and can thus be applied, outside of North America, as full-fledged stand-alone overcurrent protective devices in both residential and industrial applications. As this typical let-through current curve shows, they are highly current limiting devices which appreciably limit the amount of let-through current and destructive energy within their ratings to minimize damage levels to downstream loads and circuits. Circuit breakers that are classified as current limiting have the ability to clear damaging short circuit currents within the first half cycle of the fault, resulting in better overall protection for all circuit components. WMZS Typical let-through curve profile of a current-limiting device The X axis shows the prospective short circuit current levels. The Y axis indicates the actual let-through values (Let-through current in the example shown) at those prospective fault ratings for each WMZ device plotted. As can be interpreted from the bend in the plotted curves, each device acts to limit the damaging let-through energy (and current) at those values of short circuit current. By design, all Eaton WMZS Supplementary Protectors and WMZT Circuit Breakers are current limiting protective devices. They come in a variety of tripping characteristics, which is ideal when customizing protection to match specific load requirements. WMZS Supplementary Protectors offer a total of three different protection characteristics for this purpose: B, C, and D tripping characteristics. They feature a number of electrical accessories to enhance the performance and diagnostic capabilities of control panels, as well as a means to facilitate panel mounting and wiring. ping characteristics Miniature circuit breakers are thermal-magnetic, inverse time tripping devices. From a thermal point of view, all WMZ protectors are calibrated to trip at the same level, which is 135% of the device s fixed current rating for single pole and 145% for multi-pole at an ambient reference temperature of 40 C. Note: Higher ambient temperatures, as well as density of mounting groups, can all be accommodated but may be subject to de-rating factors. Please consult technical data for further information and appropriate curves. It is the response time of the magnetic trip which differentiates each characteristic and for which an identifying letter is assigned. The IEC 898 standard only specifically covers the B, C and D characteristics. The rest can vary from brand to brand, but essentially follow a uniform convention. 3

Product Application AP01102005E The following magnetic response times apply to each of the characteristic letters referenced in Eaton WMZ series part numbers: B: Instantaneous response between 3 5 x In (In = fixed current rating of each unit) Ideally suited for resistive loads, such as conductors or heaters. C: Instantaneous response between 5 10 x In Ideally suited for inductive loads, such as motors and solenoids. D: Instantaneous response between 10 20 x In Ideally suited for highly inductive loads, such as lighting and higher efficiency motors. Typical Inverse Time tripping characteristic of a miniature circuit breaker Inverse Time refers to the device s tripping characteristic. As the curve shows, the higher the current, the lower the tripping time. The trip response on the thermal portion is uniform throughout the line. The instantaneous response differs, depending on the characteristic selected. (e.g. B, C or D) ping is very quick (less than a half cycle) in the upper range of overcurrents (bottom right) due to the current limiting design of the Eaton Circuit Breakers. WMZT Miniature Circuit Breakers As previously mentioned, we have expanded our WMZ line of miniature circuit breakers to include a version which is listed and certified as a Molded Case Circuit Breaker (UL 489 and CSA No. 5). This line is rated up to 40A and comes in single, double and triple pole versions with instantaneous trip characteristics C and D. Of course, the line is also in conformity with the IEC standard for molded case circuit breakers, IEC 60947-2, and can therefore be universally applied. The NEC defines a circuit breaker as follows: A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating. This definition sets circuit breakers apart from any other protective device and establishes their role as primary overcurrent protective switches in all types of electrical circuits. UL listing (and CSA Certification) requires additionally that regular testing on circuit breakers be conducted by UL and CSA at the manufacturer s plant to monitor construction and verify their performance. The Eaton series includes two types: the WMZT with traditional box terminals for multiple wires, and the WMZT...T which accommodates ring-tongue terminals. Both versions can utilize a commoning link connection system available with the line. t [s] 7200 3600 1200 600 300 120 60 30 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 1.13 1.45 ➀ ➀ ➁ Specified non-tripping current I nt = 1.13 X I n for t > 1 h Specified tripping current I t = 1.45 X I n for t < 1 h ➀ 2.55 X I n : t = 1 60 s (I n < 32 A) t = 1 120 s (I n > 32 A) ➁ Type B: 3 X I n : t > 0.1 s ➂ Type B: 5 X I n : t < 0.1 s ➃ Type C: 5 X I n : t > 0.1 s ➄ Type C: 10 X I n : t < 0.1 s ➅ Type D: 10 X I n : t > 0.1 s ➆ Type D: 20 X I n : t < 0.1 s ➂ ➄ B ➃ C ➅ D 0.002 0.001 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 ➆ Multiples of I n 4

Product Application AP01102005E The advantages of a current limiting device As already mentioned, all Eaton series WMZ devices are current limiting by design. In the case of the UL 489 devices, they are also classified by UL/CSA in that manner and are marked on the label. A circuit breaker that is marked as a current limiting device is one that does not use a fusible element and, when operating within its current limiting range, limits the let-through energy (I2t) to less than the energy of a ½ cycle wave of the available symmetrical current. The label on WMZT devices lists the actual let-through energy (I2t = 60 ka2 s) and peak let-through current (6.2kA) at the maximum interrupting rating of 10kA. Current limiting circuit breakers substantially reduce the amount of damage sustained by downstream components in the event of a high short circuit fault by clearing the fault in the shortest amount of time possible due to the quick separation of its contacts and ensuing extinction of the arc current. HACR and SWD WMZT circuit breakers are also marked HACR for use in Heating, Air Conditioning and Refrigeration applications. In addition, the abbreviation SWD on the label indicates the devices are suitable for switching fluorescent lighting loads on a regular basis. Short Circuit markings on WMZ devices Below is tabulated summary of short circuit rating values that apply to the WMZS line of Supplementary Protectors and WMZT Circuit Breakers. It is important to keep in mind that short circuit markings on WMZS Supplementary Protectors (UL 1077) and WMZT Circuit breakers (UL 489) must not be interpreted in the same manner. Supplementary Protectors have short circuit markings in association with upstream primary overcurrent protective devices. Conversely, Circuit Breakers are primary overcurrent protective devices and their ratings thus refer to their short circuit Interrupting capability. Table 1. Supplementary Chart WMZS Supplementary Protectors (UL 1077) Single pole Single pole Characteristic Max. Amps Max. Volts Short Circuit Rating B and C 0.5 35A (B 6... 35A) 277 V AC 10kA 40 63A 277V AC 5kA 0.5 63A 48V DC 10kA D 0.5 40A 277 V AC 5kA 48V DC 10kA 2, 3 pole B and C 0.5 35A (B 6... 35A) 480Y/277V AC ➊ 10kA 40 63A 480Y/277V AC ➊ 5kA 2 poles in series 6 25A 96V DC 10kA 2, 3 pole D 0.5 40A 480Y/277V AC ➊ 5kA 2 poles in series 96V DC 10kA WMZT Branch Circuit Breakers (UL 489) Characteristic Max. Amps Max. Volts Single pole C and D 0.5 32A 480Y/277 V AC ➊ 10kA 40A 240V AC 10kA Single pole C and D 0.5 40A 48V DC 10kA 2, 3 pole C and D 0.5 32A 480Y/277V AC ➊ 10kA 40A 240V AC 10kA 2 pole C and D 0.5 40A 96V DC 10kA Short Circuit Interrupting Rating ➊ A circuit breaker with a 480Y/277V AC rating can be applied in a solidly grounded circuit where the nominal voltage of any conductor to ground does not exceed the lower value of the circuit breaker s rating (e.g. 277V AC) and the nominal voltage between any two conductors does not exceed its higher value (480V AC). 5

Product Application AP01102005E Table 2. Supplementary Chart WMZH Branch Circuit Breakers (UL 489) Characteristic Max. Amps Max. Volts Short Circuit Rating Single Pole C 15 25A 480Y/277 VAC 14kA 2,3 pole C 15 25A 480Y/277 VAC 14kA Single Pole D 13 20A 480Y/277 VAC 14kA 2,3 pole D 13 20A 480Y/277 VAC 14kA 2 poles in series C 15 25A 96 V DC 10kA 2 poles in series D 13 20A 96 V DC 10kA WMZD Branch Circuit Breakers (UL 489) Characteristic Max. Amps Max. Volts Single pole C 2 40A 125 V DC 10kA 2 pole in series C 2 40A 250 V DC 10kA Short Circuit Interrupting Rating Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved Printed in USA Publication No. AP01102005E February 2011 The National Electrical Code is a registered trademark of the National Fire Protection Association. All other trademarks are property of their respective owners.