Spengler goes Florentil Electrostatic printing assist system the original

Similar documents
SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

ELECTROSTATIC FIELDMETER

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Technical Data. Dimensions

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

SMARTLINE RM76 Supplementary instructions

SCHOTT EasyLED Series

Model VDL 115 Vacuum drying chambers for flammable solvents

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Grounding Monitoring Device Series 8485

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Servicing and Maintenance

SolConeX extra-low voltage flange socket

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Model VD 23 Vacuum drying chambers for non-flammable solvents

The Solid-State Decoupler (SSD)

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

Grounding Monitoring Device Series 8485

FLEXICEL UF (UNDER FLOOR)

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Duris E5 PowerFlex LED Strips 25mm LED Pitch

DATA SHEET. L1210/65/68 Tray loaders incorporating VAM1202/12 mechanism for 2x Speed. Philips Optical Storage. Philips Components

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

Troubleshooting Manual

Slot Resistance Thermometers

Duris P5 32 Strip Deep Blue

Zener Barriers Bulletin 937Z

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Datasheet. Dragon1IR PowerStars. LED Solutions. ILH-ID01-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

Fieldbus Independent I/O Modules 1 AI DMS Manual

OSLON IR 17 PowerFlood

PHOENIX CONTACT - 12/2007

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay

Labour standards ESD protection

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

PI-EX-ME-2NAM/COC-120VAC

CARTRIDGE REMANUFACTURING INSTRUCTIONS XEROX PHASER 6180 TONER CARTRIDGE

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Ground Monitoring Device Series 8485

PI-EX-ME-2NAM/COC-24VDC

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-CVS NC

HelioKlischograph K6. HelioKlischograph K6 THE AUTOMATIC ENGRAVER. Based on Innovation.

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

OSLON IR 72 PowerFlood

Atmer TM anti-static. Reduce static charge & minimise dust pick up. Innovation you can build on TM

Operating instructions. Standstill monitor A / / 2011

LS 6600 Technical Datasheet

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

2-Line BUS-Port ESD-Protection - Flow Through Design FEATURES VBUS052CD-FAH VBUS052CD-FAH-GS MOLDING COMPOUND FLAMMABILITY RATING

Tilt Sensor Switch. Item No. RBS Description Photoelectric Version 14 Page 1 of 9 Publish Date May. 31, 2018

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Series 3730 Electropneumatic Positioner Type

Coil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4

Solution Railway. tgood.com

PCB Keyswitches Product Survey Versions Recommended Key grid Illumination Keyswitch Signal indicator Keyswitch height Contacts RACON 8 12 mm Non-illum

Devices raised mounting

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Applying branch circuit breakers and supplementary protectors in North America

DeltaV Bulk Power Supplies

Thickness of the standard piece: 10 mm The most important calibration data are engraved in the side face of the specimen.

Control Head for the integrated mounting on process valves

IM /2016 REV01 LACI Production Monitoring Module

Technical Data Sheet 5mm Silicon Phototransistor T-1 3/4

Thermocouples Model TC200, for Additional Thermowell

Universal Tristop Cylinder for Cam Brakes

Level Measurement. Tank Level Instruments TLI

OSLON IR 27 PowerFlood

VACUUM FLUORESCENT DISPLAY MODULE SPECIFICATION SPECIFICATION NO. : DS DATE OF ISSUE : Dec., 04, 1995 (00)

CARTRIDGE REMANUFACTURING INSTRUCTIONS TONER CARTRIDGE DRUM CARTRIDGE

LIMO LM Medical Series Version March 01, 2010 HIGH-POWER DIODE LASER

CONTROL PANEL WIRING SPECIFICATIONS


CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

DeltaV Bulk Power Supplies

Series 3730 Type Electropneumatic Positioner

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

HD 46 HME 46. Instructions for use

Pneumatic Control/Feedback

Power Supply HARTING pcon

Product and functional description

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

Digital Positioner 8049

Resistance thermometer With spring-loaded tip Model TR55

Wöhler Miniature Camera Head Colour Ø 26 mm

Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP (System Level ESD)

List of forms CLAP/WGP by subject /68/UE

PHOENIX CONTACT - 05/2007

Surface Mount Multilayer Ceramic Chip Capacitors for Commodity Applications

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Transcription:

Spengler goes Florentil Electrostatic printing assist system the original by Alfred Doppler, managing director of Spengler Electronic AG Our team - comprised of joint venturers and partner companies with whom we have worked together for many years - has been developing and producing for decades the worldwide, renowned Spengler technology and quality in the field of specialised electro-technical devices for electrostatic applications, used in the most innovative, worldwide industrial applications. One of our core competencies are electrostatic printing assist systems in the rotogravure printing industry. Electrostatic printing assist systems (ESA) are the current state-of-the-art in rotogravure for illustrations or packaging print and are a must have for all quality printing. Task Electrostatic printing assist systems ensure colour transfer from the paint cups of gravure printing cylinders onto the print substrate, paper or film and prevent formation of missing dots. Missing dots are points that are missing in the print where the printing ink has not been transferred from the cup of the gravure printing cylinder onto the paper or the film. Missing dots mostly occur on rough or uneven surfaces of the printing material or on fast-running gravure printing presses. Physical principle of electrostatic printing assist systems The impression roller is controlled, loaded with a DC voltage and serves as current source over the printing substrate. The goal here is to achieve an even flow of current to the electrically grounded gravure cylinder over the entire print width. Paint spot without ESA The evenness of the current flow is defined by the loading system and the quality of the impression roller. The dipoles of the printing ink in the cup of the grounded gravure cylinder, which is comprised of various materials such as pigments, solvent and binding agent, are polarised within the field of the DC current, resulting in an increase in volume that ensures improved colour transfer onto the print substrate. Paint spot with ESA Spengler Electronic AG www.spengler.ag 1 of 6

You only need a minimal current that generates a current field for polarisation work in the printing ink to achieve this effect. We know from experience that in case of indirect loading systems, a current flow of approx. 15-20 μa per cm is required; in case of direct loading systems, a current flow of approx. 30-40 μa per cm impression width is required. This means that a powerful, direct loading system should be designed for a power of at least 10 ma for an impression width of 308 cm. The voltage between the print substrate and the impression roller - the nip voltage - is then usually between 600 and 1000 volts using common ESA impression rollers. U1 1 U1 U2 R1 R2 I1 Supply Voltage Nip-Voltage Semi-conductive layer of impression roller Printing substrate DC-Current 1 charged semi-conductive layer of impression roller 2 Nip-voltage 3 Printing substrate 4 Engraved cylinder R1 R2 I1 U2 2 3 4 An operating voltage of 20,000 volts is therefore required for indirect systems and up to 3,000 volts for direct loading systems to compensate for transfer losses through the semi-conducting impression rollers and air gaps. Expected results We guarantee print-out quality for all of our loading systems, even in case of only partial assignment of the maximum printing width - throughout all tonal ranges (gravure depth 5-40 μm), especially within the half-tone and quarter-tone ranges - over the entire paper web width - over the entire paper web length - with no high-frequency or low-frequency fluctuations - The fluctuation in densitometric density, which is not to be attributed to gravure tolerances, is not exceeded by more than ± 0.01in the bright range or by ± 0,05 in the dark range, evaluated as standard deviations. - The impression contact pressure can be reduced up to 50%. This increases the lifetime of the impression roller and saves energy. We offer several loading systems depending on the wishes of the respective customer, the conditions at the machine end and the ESA impression rollers. All systems comply to the current state-of-the-art and therefore fulfil without exception the legal requirements of European ATEX Ordinance 2014/34/EU. Spengler Electronic AG www.spengler.ag 2 of 6

Our classic, the loading system H-35 The power range of the loading electrode is almost that of the impression roller width. The even current flow of this non-contact loading system is achieved over the length of the loading electrode. Print-out is guaranteed, even in case of a reduced web width. The H-35 loading system requires a two- or three layer ESA impression roller. Indirect loading with long electrodes has the advantages of simplicity and reliability. The main disadvantage is that the long electrode gets dirty and has to be regularly cleaned, especially at the border and edge areas. The short, the loading system H-98 A patented further development from Spengler is the short electrode. The electrode can be designed at a length of 1/6 of the width of the impression roller. The complete electrode is placed within the print substrate and therefore protected from dirt and spray mist. The cleaning cycles are longer by several factors and handling is therefore simpler. The even current flow of this non-contact loading system is achieved by a highly-conductive layer in the interior of the impression roller. Print-out is guaranteed, even in case of a reduced web width. The H-98 loading system requires a three layer ESA impression roller. This loading system is an alternative to the almost maintenance-free side-loading systems. Spengler Electronic AG www.spengler.ag 3 of 6

The direct, the loading system ESA-2000 This side-loading unit works with direct contact to the impression roller and is the most powerful in terms of efficiency worldwide! Depending on the design, this loading system requires a single-layer impression roller with insulated bearings (not in conformity to ATEX) or a three-layer impression roller with non-insulated bearings (in conformity to ATEX) and is considered to be maintenance-free. Due to the constructive design of the Spengler ESA-2000 side-loading unit, no power limitation is specified. The devices currently used work with a voltage of up to 3,000 volts and a current of up to 15 ma. This permits greater electrical resistance bandwidths of the semi-conductive coating, and greater production tolerances when manufacturing ESA impression rollers. Florentil, the New addition in package printing with impression roller sleeve system This novel innovation on the world market is comprised of an almost maintenancefree side-loading system, constructed on the basis of the powerful ESA-2000 loading principle, which has been tried-and-tested over many years. Comment on existing solutions from the perspective of standard technology: In case of already-known side-loading units with direct or indirect loading, voltage is applied to the entire impression core to facilitate replacement of the impression sleeve in the printing unit. To ensure that the voltage does not leak away, the impression roller bearing or the axles of impression rollers with inner bearings are electrically insulated. The single-layer sleeve is now contacted with the current-carrying axle, as is the case with antistatic impression rollers. Please note that for reasons of technical standards, this is not permitted in Europe when operating a gravure printing press with flammable solvent-based inks within an explosive environment. Observance of the standards laid down according to the European ATEX Ordinance is exhaustive and an absolute must for all operators. Spengler Electronic AG www.spengler.ag 4 of 6

Depending on the type of protection to ensure the loading unit complies to the standards, the power output of these competing systems must be severely limited to prevent dangerous flammable discharges from the live impression roller core. Please also note that no electrical current may be fed through roller bearings in explosive environments. In addition to the standards for electrical devices in explosive areas, the mechanical components and their conformity is also unfortunately often ignored. For instance, EN 13463-5 stipulates that all bearings must be protected against electrical currents, including stray currents. Electrical bearing insulations may also result in dangerous heat states in the bearings. Axle insulation not permitted EX area Florentil, the new addition to the Spengler loading unit family Using this system, which has already been registered for patent, the effective current transfer can also be made outside of the gravure unit and is therefore completely protected from dirt and spray mist. 1 Transfer unit 2 Impression roller axle 3 Impression roller bearing without insulation 4 Three-layer impression roller sleeve with interior contact Electrical contact of the three-layer sleeve is on a defined contact surface of the impression roller axle that is electrically insulated from the core. 1 Sleeve 2 Insulation 3 Contact surface 4 Impression roller bearing 5 Compressed-air line for sleeve replacement Spengler Electronic AG www.spengler.ag 5 of 6

The impression roller sleeve is constructed in three layers: GRP is the base material, followed by a highly-conductive layer for load distribution over the entire printing width and then a semi-conductive outer layer to limit the current. The highly-conductive layer is fed on one side to the inner surface of the GRP tube. An insulation ring is installed at one end in the impression roller core. A live ring is embedded at the outermost end of the insulation; when the impression roller sleeve is pulled on, this then contacts to the highly-conductive layer. 1 Semi-conductive layer 2 High-conductive layer 3 Insulating layer (GRP base material) 4 Insulator 5 Contact ring 6 Impression roller core In summary, the advantages of this contact system are: - more-or-less maintenance free loading of the impression roller - reduced soiling of the impression roller from spray mist - longer lifetime of the impression roller bearing - ESA and ESD impression roller in one unit The impression roller also functions as an antistatic impression roller when the ESA system is switched off. - Conformity to standards (ATEX) fulfilled completely - High resistance bandwidth and production tolerances of the ESA sleeve impression roller. - Longer maintenance cycles of the impression roller using tried-and-tested ESA 2000 side-loading technology with a maximum loading voltage of 3,000 volts. - Can be retrofitted to existing machines Compliance to the ATEX Ordinance standards is exhaustive. Two important points should be mentioned here: - no power reduction is required - no ball-bearing currents Checklist to evaluate an ESA system for operation in an explosive environment: EC-Type Examination Certificate(s) in compliance to ATEX Ordinance 94/9/EU Recognition of the quality assurance of the manufacturer by an approved test location within the EU. CE mark with ID number of the location mentioned that is involved during the production phase. Spengler Electronic AG www.spengler.ag 6 of 6