Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog

Similar documents
Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology. Liquid-Level Transmitter Accessories Catalog

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level Plus. Liquid-Level Product Catalog. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Document Part Number Revision E

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

T E M P O S O N I C S I I I INSTALLATION

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series Board Replacement Operation Manual

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

Temposonics. Magnetostrictive, Linear-Position Sensors. G-Series Embedded Redundant Model GTE Analog (Voltage/Current) Data Sheet

Data Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

Temposonics. R-Series POWERLINK. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Family of Water Cut Analyzers

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

LTM IntelliGage Series Magnetostrictive Level Transmitters

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Profibus-DP Output.

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. HART Interface Manual LP Series

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Safety Manual LP Series. Safety Integrity Level IEC 61508

Temposonics. User s Manual. MH-CAN Testkit. CANopen & SAE J1939. Absolute, Non-Contact Position Sensors. Document Part Number.

MTS Sensors. NEWS 2013 / 2014 Agritechnica 2013 / Hall 1, Booth E127. Position and Angle Measurement in Mobile Machines. The Measurable Difference

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

FTP Factory Trade-In Program

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Level Plus Liquid-Level Sensors With Temposonics Technology

Level Measurement Continuous level measurement - Ultrasonic transmitters

Temposonics. Magnetostrictive Linear Position Sensors. EE Analog Data Sheet

Gladiator Acoustic Switch Series

4110 HART Level Encoder

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Profibus-DP Output B Product Specification

Universal IV Water Cut Meter

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

Flow Measurement SITRANS F M

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. E-Series Models EP and EL Analog and Start/Stop Outputs.

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Clamp-On Transit Time Ultrasonic Flow Meters

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

SCADAPack Modbus multivariable transmitter

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Flow Measurement SITRANS F M

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Series DMHF Heat Meter

Level-Lance Model 5400A

DMTFP Portable Ultrasonic Flow Meters

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Level Measurement Continuous level measurement - Ultrasonic transmitters

Flow Measurement SITRANS F US Clamp-on

L-Dens 4X7 Series. Process Density Sensors. ::: Process instrumentation at its best

Intrinsically Safe Temperature Concentrator System

Power/RS 485 Comm. Ultrapure Water

imag 4700 Series FLANGED MAGMETER

SCADAPack Modbus multivariable transmitter

Temposonics. Magnetostrictive Linear Position Sensors. PROGRAMMING & CONFIGURATION GBS Analog via Bluetooth. The Measurable Difference

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

imag 4700 Series FLANGED MAGMETER

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

2910 Float & Tape Transmitter

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Simplified information where and how you want it.

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

FlexBar HRT Pressure Transmitter

Welcome to the Webinar

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

LiquiDens. SensoTech. Process density meter for liquids Product description

Variable Area Flowmeter DATASHEET

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Sensors Division. Level Plus Direct Digital Access (DDA) Tank Gauge. Operation Guide and Installation Manual. P/N Revision D

TRICOR Series TCM Coriolis Mass Flow Meters

Flow Measurement SITRANS F C

Ultrasonic Heat Flow Meters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

MMT330 Series Moisture and Temperature Transmitters for Oil

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

MCG 1500SFI. MCG 1500SFI Smart Flash Infrared Servo Gauge. Features. Smart Flash Infrared Servo Gauge

Trident and Trident X2 Digital Process and Temperature Panel Meter

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Model Sono-Trak General Specification

SERIES 8000-SAN PRESSURE AND LEVEL TRANSMITTERS ALL STAINLESS DESCRIPTION. OUTPUT 4-20 ma / 2-WIRE ZERO AND SPAN ADJUSTABLE

2900 Float & Tape Transmitter

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

FOR LIQUIDS AND SOLIDS

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

High Voltage DC Meter

Micro Motion R-Series General Purpose Mass and Volume Flowmeter

Transcription:

Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology Accessories Catalog SENSORS Document 551103 Revision C Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Features Variety of Styles and Sizes to Fit Most Applications Available in 316L Stainless Steel, Teflon, Hastelloy C-276 and Nitrophyl Custom ing Available Applications Custody Transfer Inventory Control Bulk Storage Sanitary Process Control Markets Petroleum and Petrochemical LPG Terminals Biotech and Pharmaceutical Food and Beverage Waste and Wastewater Accessories overview offers a variety of floats to meet your application needs. Our floats come in a variety of sizes from less than 38 mm (1.5 in.) up to 178 mm (7 in.) in diameter. Float materials are available in stainless steel, Teflon, Hastelloy C-276 and Nitrophyl. weighted floats are also available for applications requiring ATEX approval. However, product viscosity, specific gravity, and temperature can vary widely in a process or tank gauging application. Because of these variables and others, such as tank pressure and corrosiveness, no one float can meet all requirements. Therefore, a variety of float styles are available and we will assist you in choosing the one that best meets your requirements. When choosing a float for your application, MTS recommends you choose one that has a specific gravity of at least 0.05 less than that of the measured liquid. For interface measurement, a minimum of 0.05 specific gravity differential is recommended between upper and lower liquids. also offers a variety of meters, housings, and calibration equipment as accessories to our transmitter range. Meters are available for analog, DDA, and Modbus outputs. For more information, please contact the applications department or go to www.mtssensors.com for more information. MTS Offers a Variety of M-Series Liquid-Level Product Accessories to Choose From All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to http://www.mtssensors.com for the latest support documentation and related media.

Standard Float Options General tes: 1. 2. 3. 4. 5. 6. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. When the magnet is not shown, the magnet is positioned at the center line of float. weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The offset option is required for installations that must conform to ATEX standards. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. STANDARD product Floats Pressure Temp. 0.65 251981-1 77 mm (3.01 in.) 29.3 bar (425 psi) 0.67 251981-2* 0.68 Hastelloy C 251981-3 47 mm (1.85 in.) dia. 0.71 Hastelloy C 251981-4* 0.48 251387-1 57 mm (2.22 in.) 22.4 bar (325 psi) 59 mm (2.32 in.) dia. 0.48 251387-2* 0.74 200938-1 35.5 mm (1.4 in.) 8.6 bar (125 psi) 41 mm (1.61 in.) dia. 0.74 200938-2* 50 mm (1.95 in.) 51.7 bar (750 psi) 0.74 252354* 55 mm (2.14 in.) dia. 50 mm (1.96 in.) 54 mm (2.11 in.) 4.1 bar (60 psi) 0.6 201605-2 47 mm (1.83 in.) dia. 2

Standard Float Options STANDARD product Floats Pressure Temp. 0.43 251469-1 91 mm (3.57 in.) 29.3 bar (425 psi) 89 mm (3.5 in.) dia. 0.45 251469-2* Low-liftoff FLOAT Pressure Temp. 15 mm (0.57 in.) Ref 39 mm (1.52 in.) 26 mm (1 in.) 38 mm (1.5 in.) 76 mm (3 in.) 8.6 bar (125 psi) 0.65 252228-3* 101 mm (3.95 in.) O.D. (0.7 in.) I.D. min. Standard Interface Floats Pressure Temp. 77 mm (3.01 in.) 29.3 bar (425 psi) 251982-1 251982-2* 251982-3 Hastelloy C 47 mm (1.85 in.) dia. 251982-4* 251983-1 77 mm (3.01 in.) 29.3 bar (425 psi) 1.03-1.10 251983-2* 251983-3* 47 mm (1.85 in.) dia. Hastelloy C 251983-4* 27 mm (1.06 in.) 31 mm (1.22 in.) 4.1 bar (60 psi) 0.85-0.9 201606-2 47 mm (1.83 in.) dia. 3

Sanitary Float Options General tes (for sanitary applications): 1. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 3. Sanitary polish is available for stainless-steel floats up to 200 Grit/Ra 25. 4. Electropolish is available for stainless-steel floats up to 240 Grit/Ra 15. 5. When the magnet is not shown, the magnet is positioned at the center line of float. 6. weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The offset option is required for installations that must conform to ATEX standards. 7. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 8. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. tes: 1. Float meets 3A Sanitary specifications. 2. Use this float with all Sanitary transmitter wells as other floats may enter the inactive zone when the tank is emptied. Sanitary Floats Pressure Temp. 108 mm (4.25 in.) 89 mm (3.5 in.) 47 mm (1.85 in.) dia. Centerline of magnet 10.3 bar (150 psi) 0.66 200 Grit/ Ra 25 240 Grit/ Ra 15 401513-1 401513-2* 401513-3* 401513-4* tes: 1. 2. Float meets 3A Sanitary specifications. Float may enter the inactive zone when used with 3A Sanitary transmitter wells Pressure Temp. 75 mm (2.95 in.) 59.5 mm (2.34 in.) dia. C L 38 mm (1.5 in.) 63.5 mm (2.5 in.) C L of magnet with 22.4 bar (325 psi) 22.4 bar (325 psi) 0.63 0.63 200 Grit/ Ra 25 240 Grit/ Ra 15 200 Grit/ Ra 25 240 Grit/ Ra 15 200931-1* 200931-2* 200931-3* 200931-4* 200931-5* 200931-6* 200931-7* 200931-8* 4

Sanitary Float Options te: Use this float with all Sanitary transmitter wells as other floats may enter the inactive zone when the tank is emptied. Sanitary Floats (continued) Pressure Temp. 51 mm (2 in.) dia. Over weld bead 25 mm (.98 in.) 48 mm (1.9 in.) 102 mm (4.02 in.) 8.6 bar (125 psi) 0.48 240 Grit/ Ra 15 252228-1* 41 mm (1.6 in.) (.7 in.) I.D. Min. 92 mm (3.6 in.) dia. tes: 1. Float is for clean-in-place and drain-in-place applications. 2. Float may enter the inactive zone. Consult factory about viability of usage. 51 mm (2 in.) O.D. Over weld bead 25 mm (.98 in.) ±.4 mm (.015 in.) 50 mm (1.96 in.) ±.76 (.03 in.) 22.4 bar (325 psi) 0.74 200 Grit/ Ra 25 251234-1* P/N 401467 Retainer (2X) (0.7 in.) Min I.D. Spacer 251234-2* tes: 1. Floats meet 3A Sanitary specifications. 2. Float is for clean-in-place and drain-in-place applications. 3. Float may enter the inactive zone. Consult factory about viability of usage. R.157 (4) Min. position CL 56.2 mm (2.21 in.) 72.4 mm (2.85 in.) dia. 8.6 bar (125 psi) 0.83-.86 240 Grit/ Ra 15 560564-1 23 mm (.9 in.) dia. 80 mm (3.15 in.) dia. 560564-2 5

Teflon Float Options General tes: 1. 2. 3. 4. 5. 6. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. When the magnet is not shown, the magnet is positioned at the center line of float. weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The offset option is required for installations that must conform to ATEX standards. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Teflon Floats Pressure Temp. 9 mm (0.35 in.) 0.86 Teflon 201109* 76 mm (3 in.) Centerline of 1.7 bar (25 psi) 38 C (100 F) 0.95 Teflon 251115* 61 mm (2.38 in.) dia. 1.04-1.11 Teflon 251116* 135 mm (5.3 in.) 67 mm (2.65 in.) Centerline of 1.7 bar (25 psi) 38 C (100 F) 0.86 Teflon 251939* 49 mm (1.9 in.) dia. (0.7 in.) 115 mm (4.5 in.) 28 mm (1.1 in.) dia. Centerline of 1.7 bar (25 psi) 38 C (100 F) 0.9-0.95 Teflon 251119* 115 mm (4.5 in.) dia. 1.04-1.11 Teflon 251120* 6

Nitrophyl Float Options General tes: 1. 2. 3. 4. 5. 6. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. When the magnet is not shown, the magnet is positioned at the center line of float. weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The offset option is required for installations that must conform to ATEX standards. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Nitrophyl Floats Pressure Temp. 201643-1 0.39 Nitrophyl 201643-2 (.07 in.) dia. 17.2 bar (250 psi) 104 C (220 F) 0.80-0.86 Nitrophyl 201649-1 201649-2 C L 76 mm (3 in.) 31 mm (1.2 in.) dia. Added weight for interface floats 0.91 - Nitrophyl 201650-1 201650-2 Stainless cover 17.2 bar (250 psi) 104 C (220 F) Nitrophyl 252999* Stainless float post 168 mm (6.61 in.) C L 152 mm (5.99 in.) 30 mm (1.19 in.) 153 mm I.D. (6.00 in.) dia. Nitrophyl base 7

Long-gauge Float Options General tes: 1. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The offset option is required for installations that must conform to ATEX standards. 5. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 6. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Long-gauge Floats Pressure Temp. 92 mm (3.6 in.) dia. 28 mm (1.1 in.) dia. 0.54 251223-1 0.65 Hastelloy C 251223-3* 88 mm (3.44 in.) C L 29.3 bar (425 psi) 251224-1 Hastelloy C 251224-3* 44 mm (1.72 in.) 1.03-1.10 251225-1* Hastelloy C 251225-3* C L 92 mm (3.6 in.) dia. 28 mm (1.1 in.) dia. 0.54 252961-1 252961-2* 76 mm (3 in.) 88 mm (3.44 in.) 29.3 bar (425 psi) 252962-1 252962-2* 1.03-1.10 252963-1* 252963-2* 0.44 250709-1* 0.52 Hastelloy C 250709-3* 127 mm (4.98 in.) CL 37.9 bar (550 psi) 250714-1* Hastelloy C 250714-3* 63 mm (2.49 in.) 28 mm (1.1 in.) dia. 130 mm (5.11 in.) 1.03-1.10 250855-1* Hastelloy C 250855-3* 8

6.95 in. (00.0 mm) Long-gauge Float Options Long-gauge Floats (Continued) Pressure Temp. 0.44 201248-1 0.44 201248-2* 127 mm (4.98 in.) 116 mm (4.55 in.) C L 37.9 bar (550 psi) 252959-1 252959-2* 28 mm (1.1 in.) 130 mm (5.11 in.) 1.03-1.10 252960-1* 252960-2* 178 mm (7 in.) 178 mm (7 in.) 48 mm (1.9 in.) I.D. 17.2 bar (250 psi) 0.44 0.47 Hastelloy C-22 Hastelloy C-22 251426-1* 251426-2* 251426-3* 251426-4* 251427-1* 251427-2* 251427-3* 251427-4* 1.03-1.10 251428-1* 251428-2* 201232-1 0.66 28 mm (1.1 in.) dia. 201232-2* 127 mm (5.01 in.) 22.4 bar (325 psi) 0.70 Hastelloy C 201232-3* 201232-4* 70 mm (2.76 in.) max. dia. 0.92-201233-1* 201233-2* 9

Process Meters and Enclosure Options Analog Process Meters LED Display Universal Analog Process Meter Precision Digital PD690-3-N 4 ½ Digit LED display Input: Analog 4-20 ma Output: ne 110 VAC Input Power 11 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (2 Relays) Precision Digital PD690-3-14 4 ½ Digit LED display Input: Analog 4-20 ma Output: 2 relays (2 Amp @ 250 SPDT) 110 VAC Input Power 11 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (4 Relays) Precision Digital PD690-3-17 4 ½ Digit LED display Input: Analog 4-20 ma Output: 4 relays (2 Amp @ 250 SPDT) 110 VAC Input Power 11 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (2 Relays, 4-20 ma) Precision Digital PD690-3-16 4 ½ Digit LED display Input: Analog 4-20 ma Output: 4-20 ma and 2 relays (2 Amp @ 250 SPDT) 110 VAC Input Power 11 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel XP Loop Powered Analog Meter Loop Powered on 4-20 ma output Displays in Percentage Only Embedded in XP Housing XP: Class I, II, III; Division 1; Groups B-G IS: Class I, II, III; Division 1; Groups A-G 380071 380072 380073 380095 380062 Loop Powered Analog Meter F090-A-HC-PL-XX-ZX Loop Powered on 4-20 ma output Displays loop current, engineering units, and/or value Selectable on screen engineering units IP 67 / NEMA Type 4X Intrinsically Safe 380088 10

Process Meters and Enclosure Options ANALOG PROCE METERS (CONTINUED) Multi-Channel Consolidating Analog Process Meter Precision Digital PD941-8K9-15 Input: 4 Analog 4-20 ma Output: 4 Analog 4-20 ma, 9 relays 110 VAC Input Power 32 point linearization 380089 MODBUS PROCE METERS Multivariable Modbus Process Meter Display levels in feet, inches, and 16ths of an inch Scrolling Display of Product, Interface, Temperature, or combination Input: RS485 Modbus RTU Output: 2 Form A relays and 4-20 ma 110 VAC Input Power 16 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel Single Variable Modbus Process Meter Precision Digital PD865-6R5-16 6 Digit Display in Decimal Format Display 1 process variable without interrupting Master/Slave communication Input: RS485 Modbus RTU Output: 2 Form A relays and 4-20 ma 110 VAC Input Power 16 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel 380086 380094 Modbus Master Display Modbus Master Display Product, Interface, and Temperature Input: 7 Modbus transmitters Output: ne UL Class 1, Div. 2 approved 253023-3 DDA PROCE METERS DDA Spy Display DDA Slave Display Product, Interface, and Temperature Input: 1 DDA transmitters Output: ne UL Class 1, Div. 2 approved 253023-2 11

Enclosure, Terminal and Programming Options Process Meter Enclosures XP Enclosures Display 380086 or 380094 Display 380088 XP Enclosures are available for most process meters, please contact factory for more information. 561452 561453 RST A B C D E ENTER LOCK PREA PRE B VIEW PRGM RST A B C D E ENTER LOCK PRE A PRE B VIEW PRGM NEMA Enclosures Single NEMA 4X Display 380071, 380072, 380073, 380095 Dual NEMA 4X Display 380071, 380072, 380073, 380095 Single NEMA 7 Display 380071, 380072, 380073, 380095 NEMA Enclosures are available for most process meters, please contact factory for more information. 401150 401151 400454 Modbus Terminals LCD Modbus Terminal Displays up to 4 tanks (2 levels, temp, volume) Displays up to 8 tanks (2 levels, temp) Displays levels in ft., in, and 16ths in. Input: Up to 8 Modbus transmitters Output: Modbus Mounted in NEMA 4 box Class 1 Div. 2 Includes Power Supply Calibrate from Screen 280494-X Touchscreen Modbus Terminal Displays up to 16 tanks (2 levels, temp, volume) Displays levels in ft., in, and 16ths in. Input: up to 16 Modbus transmitters Output: Modbus Pictorial display of tanks Touchscreen Mounted in NEMA 4 box Class 1 Div. 2 Includes Power Supply Calibrate from Screen 280508 12

Programming and Hardware Options Programming Accessories HT100 Hand Held Terminal M-Series Model MG Transmitter with DDA output Remote setup, troubleshooting, and maintenance 251259 Setup Software Hardware M-Series Model MG with Modbus PC setup software on CD Includes RS-485 to RS-232 adapter, part no. 380075 M-Series Model MG with Modbus PC setup software on CD M-Series Model MG with DDA PC setup software on CD M-Series Model MR PC setup software on CD Includes HART adapter, part no. 380068 M-Series Model MR PC setup software on CD HART to RS-232 adapter (SMAR H1-311) RS-485 to RS-232 adapter converter (B & B Electronics) 625051 625052 625053 252273-1 252273-2 380068 380075 3-A Label Stencil (for products that meet 3-A specifications only) Order If your transmitter must be marked with 3-A specification identification. 400868 Hex Bushing 2 in. MNPT x 3/4 in. FNPT Hex Bushing 2 in. FNPT x 4 in. MNPT Hex Bushing 1 in. FNPT x 3/4 in. MNPT 561440 561441 561448 13

and Assembly Options and weight assemblies 51 mm (2 in.) 76 mm (3 in.) 150 lb. Pull For LDF long transmitter and M-Series transmitters. (Top ring must be removed before installation) 560604 127 mm (5 in.) 51 mm (2 in.) Standard 11 lb. For M-Series transmitters 401059 A 193 mm (7.5 in.) dia. 165 mm (6.5 in.) dia. 84 mm (3.3 in.) 3 mm (.13 in.) 16 mm (.63 in.) Low Liftoff 11 lb. Assembly Use with float, part no. 252999 402364 A Section A-A 89 mm (3.5 in.) dia. 32 mm (1.25 in.) dia. (2X) 114.3 mm (4.5 in.) 1.3 X 45 Chamfer 37 mm (1.44 in.) Narrow 11 lb. Use with M-Series transmitters 402647 63.5 mm (2.5 in.) 21 mm (.81 in.) dia. FM APPROVED : 551103 Revision C 05-09 MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending. Printed in USA. Copyright 2009 MTS Systems Corporation. All Rights Reserved in all media. SENSORS MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, rth Carolina 27513, USA Tel.: +1-800-633-7609 Fax: +1-919-677-2343 +1-800-498-4442 e-mail: sensorsinfo@mts.com http://www.mtssensors.com MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 D - 58513 Lüdenscheid, Germany Tel.: +49-2351-9587-0 Fax: +49-2351-56491 e-mail: info@mtssensor.de http://www.mtssensor.de Technology Corporation 737 Aihara-cho, Machida-shi Tokyo 194-0211, Japan Tel.: +81-42-775-3838 Fax: +81-42-775-5516 e-mail: info@mtssensor.co.jp http://www.mtssensor.co.jp