Safe monitoring relays

Similar documents
E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Two-hand control unit

Safe timer relay/contact expansion modules

Safe monitoring relays

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Contact expander modules

Faults on the system Proximity switch connection technology:

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

PNOZ s1. Safety relays. Operating Manual EN-07

Electronic monitoring relays PMDsrange

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s9. Safety relays. Operating Manual EN-08

Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

20 inputs for connecting, for example:

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

Datasheet SRB301ST 24V (V.2)

PHOENIX CONTACT Features

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Datasheet - SLB 200-C04-1R

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

QUINT-PS/ 1AC/24DC/20/CO

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MINI-PS AC/10-15DC/8

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PHOENIX CONTACT - 07/2006

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

3 Pole Contactors with AC operating coils

TeSys IEC Contactors and Overload Relays

PNOZ X1. } Safety relays. Operating Manual EN-08

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Contact protection relay

QUINT-PS/ 1AC/24DC/ 5

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Power supply module, bus connection module

Installation / Control Technique

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

MIC-2 MKII, Multi-instrument DATA SHEET

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

Transcription:

monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator for: Supply voltage on channel 1/2 Switch status Fault signal if simultaneity time is exceeded Semiconductor outputs signal: Error Switch status Semiconductor input for reset function Measuring inputs for single or three-phase motors Measuring voltage selectable Feedback loop Plug-in connection terminals (either cage clamp terminal or screw terminal) See order reference for unit types Unit description The unit is used for safe standstill monitoring. It is designed for use on monitoring on plants with dangerous machine parts or tools (EN 1088 clause 7.4), Safety circuits in accordance with EN 60204-1 and IEC 60204-1. is only detected on powerfree measuring circuits. Residual voltages, induced voltages or drives within the position control will prevent safe standstill detection! Safety features Relays K1 and K2 are interlocked in such a way that the unit cannot be switched back on in the case of contact welding or an open circuit. The unit monitors the measuring circuits for open circuit. If an open circuit occurs between the unit and the motor or on the motor itself, the unit immediately switches off. The standstill monitor prevents the plant from being enabled in the following cases Power supply failure Component failure Measuring circuits are open circuit Coil defect/open circuit A1 A2 L2 L3 13 23 41 ~ = Input K1 Power Feedback 0 V 24 V Reset K2 Y1 Y2 Y30 Y31 Y32 Y35 RESET 14 24 42

Function description The device uses two separate measuring channels to measure the regenerated voltage, induced from the motor during the rundown period or during start-up. If the voltage falls below the set response value (standstill threshold), the standstill monitor enables the monitored plant. If the voltage exceeds the set release value, the standstill monitor disables the monitored plant. To reactivate, the voltage at both channels must fall below the response value U on within the time t g (simultaneity monitoring). To do this the feedback loop Y1-Y2 must be closed. If the Timing diagram simultaneity requirement is exceeded, the standstill monitor does not enable the monitored plant. The unit can be reactivated by switching 24 VDC on and off at the RESET input. The response value U on can be set jointly for both channels in order to suit the motor that is to be monitored. The release value U off (hysteresis) corresponds to twice the response value. When used with frequency converters, the cannot detect standstill until the controller inhibit has been switched off. After the supply voltage is switched on, the unit performs a self test. The unit simulates a situation in which the release value is exceeded and the measuring circuit has an open circuit. The correct function of the output relay and feedback loop is also tested. The test takes ca. 1.5 s. Operating modes: Single-channel operation: One measuring circuit affects both channels No redundancy (failsafe) in the measuring circuits Dual-channel operation: Two redundant (identical) measuring circuits affect channel 1 and 2 Monitoring of voltages in the measuring circuit (failsafe in the event of a short circuit) POWER Feedback Output safe Output aux Semi Y35 RESET U/UL2 U off U on t < tg t > tg 50 ms 1,5 s Key POWER: Supply voltage U/UL2: Input circuit, L2, L3 Feedback: Feedback loop Y1-Y2 Output safe: Safety contacts 13-14, 23-24 Wiring Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24 are safety contacts, output 41-42 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the Output aux: Auxiliary contact 41-42 Semi Y35: Semiconductor output for fault signal RESET: Reset input RESET U on : Response value output contacts (see technical details). Use copper wire that can withstand 60/75 C. When used with converters: Use screened cable for the wiring between the standstill monitor and the U off : Release value t g : Simultaneity motor. Connect the cable screening on the motor. -2

Preparing for operation Supply voltage Supply voltage AC DC A1 A1 L+ A2 N A2 L- Input circuit Input circuit Single-phase motor Three-phase motor N M ~ L2 L3 L2 L3 M ~ L2 L3 Feedback loop Contacts from external contactors or link Y1 Y2 13 (23) 14 (24) K5 K6 K5 K6 N Y1 Y2 Semiconductor output Y32: Semiconductor output for switch status Y35: Semiconductor output for fault signal Y31 Y32 Y35 Y30 24 V DC SPS Input SPS Input 0 V Semiconductor input SPS Output 0 V RESET Y30

Terminal configuration Installation The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions * with cage clamp terminals 121 (4.76") 94 (3.70") * 101 (3.98") 45 (1.77") -4

Notice Service life graph This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC15: 230 V DC13: 24 V AC1: 230 V DC1: 24 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 GB Cycles x 10 3 F Nombre de manœvres x 10 3 E Número de ciclos x 10 3 I Numero dei cicli di commutazione x 10 3 NL Aantal schakelingen x 10 3 Technical details Electrical data Supply voltage Supply voltage U B AC/DC 24-240 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 5.0 VA Power consumption at U B DC 3.0 W Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Feedback loop DC: 24.0 V 35.0 ma Number of output contacts Safety contacts (S) instantaneous: 2 Auxiliary contacts (N/C): 1 Category of output contacts in accordance with EN 954-1 Safety contacts (S) instantaneous: 4 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V P max : 1500 VA Safety contacts: DC1 at 24 V P max : 150 W Auxiliary contacts: AC1 at 240 V P max : 1500 VA Auxiliary contacts: DC1 at 24 V P max : 150 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 3.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 4.0 A Auxiliary contacts: AC15 at 230 V I max : 3.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 4.0 A Contact material AgCuNi + 0.2 µm Au

Electrical data External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 6 A Auxiliary contacts: 6 A Blow-out fuse, slow Safety contacts: Auxiliary contacts: Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: Auxiliary contacts: Semiconductor outputs (short circuit proof) 24.0 V DC, 50 ma External supply voltage 24.0 V DC Voltage tolerance -20 %/+20 % Semiconductor input High 15 VDC Low 5VDC Input current 20 ma Measuring circuit Input voltage -L3, -L2, L2-L3 0 690 VAC/DC Input voltage in accordance with UL 0 600 VAC Frequency range 0 3000 Hz Input impedance 1300 kohm Switching threshold per channel Response value U on 7,5 500 mv Order no.: 777951, 787951 20-500 mv Order no.: 777949, 787949 120-3000 mv Order no.: 777950, 787950 Release value U off 2 x Uon Max. inrush current: 10 A, max. 20 ms Times Switch-on delay at motor standstill Max. 1,500 ms After power on max. 2,200 ms Delay-on de-energisation after motor on max. 170 ms Recovery time at max. switching frequency 1/s after power failure 2200 ms Simultaneity, channel 1 and 2 7 s Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage EN 60947-1 Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0-6

Mechanical data Max. cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-1WG Order no.: 777949, 777950, 777951 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG Order no.: 777949, 777950, 777951 without crimp connectors or with TWIN crimp connectors 0.50-1.50 mm², 24-16 AWG Order no.: 777949, 777950, 777951 Torque setting with screw terminals 0.60 Nm Order no.: 777949, 777950, 777951 Max. cross section of external conductors with cage clamp terminals/spring-loaded terminals: Flexible without crimp connectors 787951 0.20-1.50 mm², 24-16 AWG Order no.: 787949, 787950, Cage clamp terminals/spring-loaded terminals: Terminal points 2 Order no.: 787949, 787950, 787951 per connection Stripping length 8 mm Order no.: 787949, 787950, 787951 Dimensions Height 101.0 mm Order no.: 787949, 787950, 787951 94.0 mm Order no.: 777949, 777950, 777951 Width 45.0 mm Depth 121.0 mm Weight 315 g Order no.: 787949, 787950, 787951 320 g Order no.: 777949, 777950, 777951 The standards current on 03/05 apply. Order reference Type Features Terminals Order no. C 24-240 VAC/DC 0,02-0.5 V Cage clamp terminals 787 949 24-240 VAC/DC 0,02-0.5 V Screw terminals 777 949 C 24-240 VAC/DC 0,12-3 V Cage clamp terminals 787 950 24-240 VAC/DC 0,12-3 V Screw terminals 777 950 C 24-240 VAC/DC 0,0075 0,5 V Cage clamp terminals 787 951 24-240 VAC/DC 0,0075 0,5 V Screw terminals 777 951