E-STOP relays, safety gate monitors

Similar documents
E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

Safety relays PNOZsigma

Two-hand control unit

E-STOP relays, safety gate monitors

Two-hand control unit

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safe monitoring relays

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Contact expander modules

Safe monitoring relays

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PNOZ s1. Safety relays. Operating Manual EN-07

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

PNOZ s2. Safety relays. Operating Manual EN-07

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

20 inputs for connecting, for example:

PNOZ s9. Safety relays. Operating Manual EN-08

Faults on the system Proximity switch connection technology:

Datasheet - SRB 402EM-24V

Electronic monitoring relays PMDsrange

Datasheet - SRB 301LC/B-24V

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

PNOZ X1. } Safety relays. Operating Manual EN-08

PNOZ X2.1. } Safety relays. Operating Manual EN-05

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet SRB301ST 24V (V.2)

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Datasheet - SLB 200-C04-1R

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

MSR178DP. Description. Features. Specifications

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

PHOENIX CONTACT Features

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

Non-Contact Safety System CES-AZ

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

PSR UC/ESAM4/3X1/1X2/B

Datasheet - AZM 200SK-T-1P2PW

Datasheet - CSS 11-30S-D-M-ST

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Transcription:

Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Gertemerkmale Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary contacts (N/C), instantaneous Connection options for: E-STOP pushbutton Safety gate limit switch Reset button Light barriers LED indicator for: Switch status channel 1/2 Supply voltage See order reference for unit types ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Sicherheitseigenschaften Zusatz - AC/DC-Gerte_PNOZ The tranformer is short circuitproof. An electronic fuse is used on a DC supply. Approvals Unit description SÜDDEUTSCHLAND Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates Light beam devices Zulassungen Block diagram Blockschaltbild A1 A2 3 7 13 23 33 43 53 6 3 71 81 91 01 ~ = Input Input Input Reset/ Start Reset/ Start K1 Power K2 Feedback K3 Y2 14 24 34 44 54 6 4 72 82 92 02

Function description ][Funktionen_einkanalig_nur_24_V_ACDC Single-channel operation (only with U B 24 VAC/DC): no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ][Funktionen_zweikanalig_ohne_quer Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits in the input circuit and, with a monitored reset, in the reset circuit too. Timing diagram ][Funktionen_zweikanalig_mit_quer_manu Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits and shorts between contacts in the input circuit. ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_manuStart Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ][Funktionen_berStart_allg Monitored reset: Unit is active once the input circuit is closed and then the reset circuit is closed and opened again. the reset circuit is closed and then opened again once the input circuit is closed. ][Funktionen_Kontaktvervielfachung Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Zeitdiagram_auto_manu_ueber1_aux 1 2 3 a b a b POWER Reset/Start Input Output safe Output aux. t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t2 t1 t3 Key Power: Supply voltage Reset/Start: Reset circuit 3()- Input: Input circuits -, - Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64 Wiring ][Verdrahtung_Si_Hi_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64 are safety contacts, outputs 71-72, 81-82, 91-92, 01-02 are auxiliary contacts (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cabling runs l max in the input circuit: Output aux: Auxiliary contacts 71-72, 81-82, 91-92, 01-02 : Automatic reset : Manual reset : Monitored reset a: Input circuit closes before reset circuit I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation t 3 : Recovery time -2

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC A1 A2 L1 N PE A1 L+ A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts E-STOP with detection of shorts across contacts Safety gate without detection of shorts across contacts S2 Safety gate with detection of shorts across contacts S2

Reset circuit Reset circuit E-STOP wiring (single-channel) Safety gate (single-channel) E-STOP wiring (dual-channel) Safety gate (dual-channel) Automatic reset 3 Manual reset 3 Monitored reset 3 7 7 Feedback loop Feedback loop Automatic reset Monitored/manual reset Contacts from external contactors Y2 13 (23... 63) 14 (24... 64) K5 K6 K5 K6 L1 N Y2 13 (23... 63) 14 (24... 64) K5 K6 K5 K6 L1 N Key /S2 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration Klemenbelegung 3 7 Y2 A1 13 23 33 43 53 63 71 81 91 01 13 23 33 43 53 63 71 81 91 01 POWER 19517 CH.1 CH.2 14 24 34 44 54 64 72 82 92 02 14 24 34 44 54 64 72 82 92 02 A2 Installation Dimensions Montage_PNOZ_X The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). 121 (4.76") Abmesungen 75 (2.95") 87 (3.42") 90 (3.54")

Notice ][WICHTIG_PDB_alt This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC1: 230 V DC13: 24 V Lebensdauerkurve AC15: 230 V DC1: 24 V AC1: 400 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœuvres x 10 3 NL Aantal schakelingen x 10 3 ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage U B AC 24 V, 42 V, 110-120 V, 230-240 V Supply voltage U B DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 10.0 VA No. 774700, 774701, 774703, 774706 Power consumption at U B DC 5.5 W No. 774709 Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 50.0 ma Reset circuit DC: 24.0 V 100.0 ma Feedback loop DC: 24.0 V 100.0 ma Number of output contacts Safety contacts (S) instantaneous: 6 Auxiliary contacts (N/C): 4 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Safety contacts: AC1 at 400 V I min : 0.01 A, I max : 5.00 A P max : 2000 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Contact material AgSnO2 + 0.2µ Au -6

Electrical data External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 6 A Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 45 Ohm No. 774709 single-channel at U B AC 45 Ohm No. 774700, 774701, 774703, 774706 dual-channel without detect. of shorts across contacts at U B DC 90 Ohm No. 774709 dual-channel without detect. of shorts across contacts at U B AC 90 Ohm No. 774700, 774701, 774703, 774706 dual-channel with detect. of shorts across contacts at U B DC 15 Ohm No. 774709 dual-channel with detect. of shorts across contacts at U B AC 15 Ohm No. 774700, 774701, 774703, 774706 Min. input resistance in the starting torque 89 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 t M in years 20 Times Switch-on delay with automatic reset typ. 180 ms No. 774700, 774701, 774703, 774706 190 ms No. 774709 with automatic reset max. 250 ms with automatic reset after power on typ. 200 ms with automatic reset after power on max. 300 ms with manual reset typ. 200 ms with manual reset max. 250 ms on monitored reset with rising edge typ. 150 ms No. 774700, 774701, 774703, 774706 165 ms No. 774709 on monitored reset with rising edge max. 200 ms No. 774700, 774701, 774703, 774706 220 ms No. 774709 Delay-on de-energisation with E-STOP typ. 20 ms with E-STOP max. 30 ms with power failure typ. 170 ms with power failure max. 250 ms Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 300 ms Min. start pulse duration with a monitored reset with rising edge 50 ms Simultaneity, channel 1 and 2 150 ms Supply interruption before de-energisation 35 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm

Environmental data Climatic suitability EN 60068-2-78 Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.00 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.20-4.00 mm², 24-10 AWG No. 774701, 774703, 774706 0.20-4.00 mm², 24-10 No. 774700, 774709 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.20-2.50 mm², 24-14 AWG No. 774701, 774703, 774706 0.20-2.50 mm², 24-14 No. 774700, 774709 without crimp connectors or with TWIN crimp connectors 0.20-2.50 mm², 24-14 AWG No. 774701, 774703, 774706 0.20-2.50 mm², 24-14 No. 774700, 774709 Torque setting with screw terminals 0.60 Nm Dimensions Height 87.0 mm Width 90.0 mm Depth 121.0 mm Weight 540 g No. 774709 720 g No. 774700, 774701, 774703, 774706 Technische Daten_Satz No. No. stands for order number. Technische Daten_Satz Normen The standards current on 2009-04 apply. ][Dauerstrom_ACDC Conventional thermal current Number of contacts I th (A) at U B DC I th (A) at U B AC 1 8.00 A No. 774709 8.00 A No. 774700, 774701, 774703, 774706 2 8.00 A No. 774709 7.00 A No. 774700, 774701, 774703, 774706 3 7.00 A No. 774709 5.60 A No. 774700, 774701, 774703, 774706 4 6.10 A No. 774709 4.90 A No. 774700, 774701, 774703, 774706 5 5.40 A No. 774709 4.40 A No. 774700, 774701, 774703, 774706 6 5.00 A No. 774709 4.00 A No. 774700, 774701, 774703, 774706 Bestelldaten Order reference Type Features Terminals Order no. 24 VAC Screw terminals 774 700 42 VAC Screw terminals 774 701 110-120 VAC Screw terminals 774 703 230-240 VAC Screw terminals 774 706 24 VDC Screw terminals 774 709-8