Central Power Research Institute, Medipally PO, Uppal, Hyderabad, Telangana. Discipline Electrical Testing Issue Date

Similar documents
This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CG Transformer Division Laboratories, Crompton Greaves Ltd., Kanjurmarg (East), Mumbai, Maharashtra

Annexure-1 (CC no )

Quality assurance Test Facilities for Gapless ZnO Surge Arresters in High Voltage Division of CPRI, Bengaluru

Externally Gapped Line Arresters Smart Solution for Stable Power Supply

Externally Gapped Line Arresters Smart Solution for Stable Power Supply

Plug and Operate Transformer Technology

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Medium Voltage Metal-Enclosed Power Capacitor Banks

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

National Electrical Test Facility (NETFA)

for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages

File Ref: CP No.: CP1205 Rev. 0 Page: 1 of 25 CERTIFIED TEST REPORT. Cooper Power Systems. 28 kv Class 600 Amp 16.2 / 28.

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Each VariSTAR Type AZU arrester must pass the following production tests: 100% Physical Inspection 100% Leakage Current Test 100% RIV Test

Power Transmission Division Link between power generation and distribution

ZORC Surge Suppressor. Operating Manual

Elastimold Molded Vacuum Recloser - MVR

2 Principle of lightning protection

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

INTERNATIONAL STANDARD

CERTIFIED TEST REPORT

02/11/2015

PROTEC Z. High Frequency Transient Surge Suppressors For protection of medium voltage motors, generators and dry type transformers

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

Type VRLTC tap changer

HiRES TRANSIENT RECORDER

INTERNATIONAL STANDARD

APPROVED SIGNATURES/ 客户确认. Manufacturer/ 制造商

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Standards Update Notice (SUN) Issued: August 11, 2017

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

ENGR. MARITES R. PANGILINAN, P.E.E.

Overvoltage Protection Devices

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

MINI-PS AC/10-15DC/8

HE Insert Series. Product Specification Sep 11 th, 2015 Rev. B. Table of contents

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Representatives Meeting June 7, Oil insulated instrument transformers Reimund Gross Product Manager High-Voltage ITs

P r o t e c t o r s C h a p t e r 227

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

ZORC Surge Suppressor. Operating Manual

Autodaptive Capacitor Control M 2501B

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Motor Surge Suppressors and Cable Considerations

Providing the missing piece in your Condition Based Monitoring platform

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

Electromagnetic Compatibility ( EMC )

QUALITROL QTMS Transformer Monitoring System

APPROVED SIGNATURES/ 客户确认. Manufacturer/ 制造商

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

LPI SG + SST Spark Gap Surge Filter

Programmable Power Supply with DALI

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Technical Specification

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

NI Serial Hardware Specifications Guide

Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

PCT2000. User Manual. Precision current transducer 2000 A

HV-CS kv Edge Mount Triaxial Jack

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Testing Instruments Manufactured by

CONNEX. The Plug-in Connection System for Power Transformers and Gas-Insulated Switchgear. the power connection THE PFISTERER GROUP

2701DLA 25kV Class DEADBREAK to LOADBREAK ADAPTER

PT 3-PB-ST. Extract from the online catalog. Order No.:

TF501, TF521 Terminal Bases

R3&A Limited, Cobourg, ON

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Mini PCI Express Card Socket

RE9RA21MW7 off-delay timing relay s V AC -

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

4 channel PD tester for semiconductor test TPP

PRODUCT SPECIFICATION

NEW surge protective devices

Surge Protective Device

LPI SST Surge Filters

Technical Data Sheet Medium Current Power Surge Filters

TU531, TU532 Terminal Unit

Double metallized film pulse capacitor, polypropylene dielectric According to IEC Grade 1.1 Small sizes Replacing PHE427, PHE428

New Solutions. for AC Motor Starters

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Proposal for Ethernet IEEE802.3 isolation requirements Rev.1

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

Safety Standards. Model Number:

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

ATX-3000 Product Specification Enhance Electronics Co.,LTD

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

EngyVolt RV12 and RV15

Transcription:

Last Amended on 31.07.2015 Page 1 of 11 I. SWITCHGEAR EQUIPMENT 1. High Voltage switchgear & control gear and AB switches Ratings upto 1200 kv system Switching Impulse Voltage (Dry & Wet) Power Frequency Voltage (Dry & Wet) (EMC) Radio interference Voltage IEC 62271-102: 2001, Amd. 1: 2011, Amd.2: 2013 IEC 62271-1: 2007 Amd.1: 2011 IEC 62271-203: 2011 IS 9921 (Part 1): 1981, IS 9921 (Part 2): 1982, IS 9921 (Part 3): 1982, IS 9921 (Part 4): 1985, All Part (RA 1992) IS 9920 (Part 1): 2002 IS 9920 (Part 2): 2001 IS 9920 (Part 3): 1982 IS 9920 (Part 4): 1985 (RA 2002) Mechanical Endurance IS 9920 (Part 4): 1985 (RA 2002) IS 9921 (Part 4): 1985 (RA 2002) IEC 62271-102: 2001 Amd.1: 2011 Amd. 2: 2013 Mechanical operations Artificial Pollution by Salt-fog Method on Insulators upto 800 kv System IEC 60507: 2013 IS 8704: 1995 Corona Inception & Extinction Voltage SOP No. 01/01, 02/01, 03/01, Visible Discharge

Last Amended on 31.07.2015 Page 2 of 11 2. Alternating Current Circuit breakers Rating upto 1200 kv System Switching Impulse Voltage (Dry & Wet ) Power Frequency Voltage (Dry & Wet) IEC 62271-100: 2008, Amd. 1: 2012 IEC 62271-200: 2011, IEC 62271-203: 2011 IEC 62271-1: 2007, Amd. 1: 2011, Amd. 2: 2013 IS 12729: 2004, IS 13118: 1991 (RA 1997) (EMC) Radio Interference Voltage Artificial Pollution by Salt-fog Method on insulators upto 800 kv System IEC 60507/2013; IS 8704/1995 Corona Inception & Extinction Voltage Visible Discharge SOP No. 01/01, 02/01, 03/01, II. TRANSFORMERS AND REACTORS 1. Reactor upto 1200 kv System withstand IEC 60076-4: 2002 IS 5553 (Part 1 to 8): 1990 2. Combined instrument transformer (up to 1200 kv System) Power frequency Voltage (Dry & Wet) IEEE C57.13: 1993 IEC 61869-1: 2007 IEC 61869-2: 2012 and IEC 61869-3: 2011, IS 2705 (Part 1): 2002 IS 2705 (Part 2): 2002 IS 2705 (Part 3): 2002 IS 3156 (Part 1 to 4): 1992 (RA 2002)

Last Amended on 31.07.2015 Page 3 of 11 3. Current Transformer (upto 1200 kv System) s for Accuracy IS 2705 (Part 1): 2002 IS 2705 (Part 2): 2002 IS 2705 (Part 3): 2002 IEC 61869-1: 2007 IEC 61869-2: 2012 0.1 Class and above (100 A to 5 ka) Temperature rise 1 C to 75 C (Temp rise) Enclosure tightness at ambient temperature High Voltage power frequency on primary winding High Voltage power frequency on Secondary winding High Voltage power frequency wet withstand Voltage on outdoor Current transformer Measurement of capacitance and Dielectric Dissipation factor (Tan Delta) for liquid immersed Current transformer RIV Qualitative (Visual check for leakages) C: 0.01 pf up to 75 nf Tan delta: 1 x 10-4 to 100

Last Amended on 31.07.2015 Page 4 of 11 Current Transformer (upto 1200 kv System) Verification of Terminal Markings & Polarity Over Voltage inter turn IS 2705 (Part 1): 2002 IS 2705 (Part 2): 2002 IS 2705 (Part 3): 2002 IEC 61869-1: 2007 IEC 61869-2: 2012 Qualitative (Visual check) 20 kv rms to 1200 kv rms Lightning impulse Voltage on primary winding Chopped Lightning impulse Voltage on Primary winding Measurement of Transmitted over Voltage Switching impulse Voltage withstand on primary winding (Dry & Wet) Chopped wave / Fast Transient Corona SOP No. 01/01, 02/01, 03/01, 4. Voltage transformer & capacitor Voltage transformers transformer (upto 1200 kv System) s for Accuracy IEC 61869-1: 2007 IEC 61869-3: 2011 IEC 61869-5: 2011 IS 3156 (Part 1 to 4): 1992 (RA 2002) 0.1 Class and above () Temperature rise 1 C to 75 C (Temp rise) Enclosure tightness at ambient temperature Qualitative (Visual check for leakages)

Last Amended on 31.07.2015 Page 5 of 11 Voltage transformer & capacitor Voltage transformers transformer (upto 1200 kv System) High Voltage power frequency withstand s on primary terminals (On external insulationwet ) IEC 61869-1: 2007 IEC 61869-3: 2011 IEC 61869-5: 2011 IS 3156 (Part 1 to 4): 1992 (RA 2002) Verification of terminal Markings & Polarity Qualitative (Visual check) High Voltage Power Frequency withstand s on Secondary Terminals Ferro Resonance and Transient Response Short Circuit Withstand Capability (Except PD measurement) Chopped Lightning Impulse Voltage on Primary Winding Switching impulse Voltage withstand on primary winding (Dry & Wet) Lightning impulse Voltage withstand on Capacitor Voltage transformer RIV

Last Amended on 31.07.2015 Page 6 of 11 Voltage transformer & capacitor Voltage transformers transformer (upto 1200 kv System) Measurement of Transmitted over Voltage IEC 61869-1: 2007 IEC 61869-3: 2011 IEC 61869-5: 2011 IS 3156 (Part 1 to 4): 1992 (RA 2002) Measurement of Capacitance and Dielectric Dissipation Factor (Tan Delta) on Capacitor Voltage Transformer IEC 60358: 1990 IS 9348: 1998 C: 0.01 pf upto 75 nf Tan delta: 1 x 10-4 to 100 Measurement of High Frequency Capacitance & Equivalent series Resistance Measurement Measurement of Stray Capacitance and Conductance Measurement IEC 60358: 1990 HFC: 20 pf to 20 nf ESR: 0.2 Ω to 200 Ω Stray C: 2 pf to 500 pf Stray conductance: 0.2 S to 200 S Corona SOP No. 01/01, 02/01, 03/01, 5. Power/ Distribution/ Traction/Auto Transformers upto 1200 kv System Separate Source Voltage withstand Measurement of dielectric Dissipation Factor (tan delta) and Capacitance of the Windings withstand (dry) Chopped Lightning IS 2026 (Part 3): 2009 IS 2026 (Part 3): 2009 IS 11171: 1985 (RA 2006) IEC 60076-3: 2013 IEC 60310-1: 2014 BS 171 (Part 3): 1987 ANSI:C-57.12.00: 2000 ANSI:C.57.12.90: 1993 C: 0.01 pf upto 75 nf Tan delta: 1 x 10-4 to 100 Transfer Surge

Last Amended on 31.07.2015 Page 7 of 11 III. TRANSMISSION LINE EQUIPMENT AND LINE ACCESSORIES 1. Hollow Insulator, Post insulator (Indoor/ Outdoor) upto 1200 kv System withstand Dry or wet Power frequency Voltage withstand IEC 60168: 2001 IS 5621: 1980 (RA 1988) IS 5350 (Part 1): 1970 (RA 1999) IS 5350 (Part 2): 1973 (RA 1991) IS 5350 (Part 3): 1971 (RA 1991) Dry or wet Power frequency Voltage flashover Switching impulse Voltage withstand (Dry & Wet) 2. HV Fuses (Horn Gap) upto 33 kv System Lightning impulse Voltage Dry Power Frequency Voltage dry and wet IEC 60282-1&2: 2002 and 2008 IS 9385 (Part 2): 1980 (RA 2002) ANSI C37.41: 2000 3. Porcelain Insulators for over Head Power Lines with Nominal Voltage greater than 1000 V, Insulator string, Post insulators, Solid core insulator, Composite insulators, pin Insulator, Polycrete Housings up to 1200 kv System Visual Examination Verification of Dimensions Visible Discharge Dry Power frequency Voltage withstand and Flashover Wet Power Frequency Voltage withstand and Flashover IEC 60168: 2001 IEC 60383-1: 1993 IEC 60383-2: 1993 IEC1109: 2008 IEC 60433: 1998 IS 2544: 1973 (RA 2006) Amd. 4: 1991 IS 731: 1971 Amd. 7: 2008 IS 1445: 1977, Amd. 5: 1993, (RA 1989) Qualitative (Visual check)

Last Amended on 31.07.2015 Page 8 of 11 Porcelain Insulators for over Head Power Lines with Nominal Voltage greater than 1000 V, Insulator string, Post insulators, Solid core insulator, Composite insulators, pin Insulator, Polycrete Housings up to 1200 kv System Voltage Distribution (As per Customer Request) & power Frequency puncture withstands (dry) and 50% impulse Voltage Flashover Switching Impulse Voltage withstand (dry & wet) IEC 60168: 2001 IEC 60383-1: 1993 IEC 60383-2: 1993 IEC1109: 2008 IEC 60433: 1998 IS 2544: 1973 (RA 2006) Amd. 4: 1991 IS 731: 1971 Amd. 7: 2008 IS 1445: 1977, Amd. 5: 1993, (RA 1989) Corona Inception and Extinction Voltage SOP No. 01/01, 02/01, 03/01, Artificial Pollution by Salt-fog Method IEC 60507: 2013 IS 8704: 1995 4. High Voltage insulators upto 1200 kv System Radio Interference Voltage IEC 60437: 1997 5. Surge Arrester for Alternating Current Systems upto 1200 kv System Power Frequency Voltage withstand s of arrester Housing (Dry & Wet) on Arrester Housing (Dry) Switching impulse Voltage on Arrester Housing (Dry & wet) RIV IEC 60099-4: 2014 IS 3070 (Part 3): 1993 (RA 2004)

Last Amended on 31.07.2015 Page 9 of 11 Surge Arrester for Alternating Current Systems upto 1200 kv System Corona SOP No. 01/01, 02/01, 03/01, Contamination/Pollution on Lightning Arrester ANSI/IEEE C62.11: 2005, and IS 3070 (Part 3): 1993 (RA 2004) 6. Bushing for Alternating Voltage upto 1200 kv System Dry Power Frequency Voltage Withstand Wet Power Frequency Voltage withstand (on outdoor, Outdoor- Indoor and Outdoor-Oil Immersed Bushing of which units upto 245 kv) IEC 60137: 2008 IS 2099: 1986 (RA 2003) Amd. 1: 1989, Amd. 2: 1993 IEEE C 57.19.01: 2000 withstand (dry) and 50% Impulse Voltage Flashover. Switching Impulse Voltage withstand (Dry & wet) EMC (RIV) Measurement of Dielectric Dissipation Factor and Capacitance at Ambient Temperature C: 0.01 Pf upto 75 nf Tan delta: 1 x 10-4 to 100

Last Amended on 31.07.2015 Page 10 of 11 Bushing for Alternating Voltage upto 1200 kv System Corona SOP No. 01/01, 02/01, 03/01, Artificial Pollution by Salt-Fog Method IEC 60507: 2013 IS 8704: 1995 7. Aluminium Conductor for Overhead Transmission Lines Connectors & Clamps upto 1200 kv System Radio Interference Voltage Corona inception and extinction Voltage IEC 60437: 1997 IS 398 (Part 5): 1992 (RA 1997) IEC 61284: 1997 SOP No. 01/01, 02/01, 03/01, 8. On load Tap Changer & Tap Changers Power Frequency Voltage Lightning Impulse Voltage withstand IS 8468: 1977 (RA 2006) Amd. 1: 1980 IEC 60214: 2003 9. Coupling Capacitor and Capacitor Divider upto 1200 kv System on Arrester housing (Dry) IEC 60358: 1990 IS 9348: 1998 IEC 61869-5: 2011 Switching Impulse Voltage withstand (Dry & Wet) Discharge Measurement of Capacitance and Dielectric dissipation Factor (Tan delta) C: 0.01 pf up to 75 nf Tan delta: 1 x 10-4 to 100

Last Amended on 31.07.2015 Page 11 of 11 Coupling Capacitor and Capacitor Divider upto 1200 kv System High frequency Capacitance and ESR Measurements Stray Capacitance and Conductance Measurements IEC 60358: 1990 IS 9348: 1998 & As per customer Reference IEC 61869-5: 2011 HFC: 20 pf to 20 nf ESR: 0.2 Ω to 200 Ω Stray C: 2 pf to 500 pf Stray conductance: 0.2 S to 200 S 10. Insulators and similar Equipment upto 800 kv DC System Dry DC Voltage withstand and flashover Wet DC Voltage withstand and flashover IEC 61325: 1995, IEC 60060-1: 2010 (±) 8 kv to (±) 1200 kv DC Dry DC Voltage long duration withstand IEC 60060-1: 2010 (±)8 kv to (±)1200 kv DC Wet DC Voltage long duration withstand RIV IEC 60437: 1997, IEC 61284: 1997, CISPR 18-2: 2010 Corona IEC 61284: 1997 PGCIL/NTPC specification (±)8 kv to (±)1200 kv DC Lightning impulse Voltage Dry and Wet switching Impulse Voltage IEC 61325: 1995, IEC 60060-1: 2010 -X-X-X-X-X-X-X-X-X-X-X-X-X-X-