Cylindrical Proximity Sensor

Similar documents
Inductive Proximity Sensor

Inductive Proximity Sensor

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

E2E. High performance in small sizes. Miniature Cylindrical Proximity Sensor. Ordering Information

Thread length (overall length)

Thread length (overall length) material

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

E2Q4 Square Proximity Sensor

E2EM. Long-distance Proximity Sensor. Ordering Information. Safe Mounting with Greater Sensing Distance and Easy Wiring with No Polarity

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Mini Photoelectric Sensor

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Miniature Inductive Prox TL-W

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

Miniature Inductive Prox TL-W

Cable specifications PVC

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Chemical Resistant Inductive Prox

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Inductive Proximity Sensor

Photoelectric Sensor

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Safety Relay Unit (I/O Unit Type)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Rotary Encoder. Output configuration Open collector Voltage Line driver (see note 3) 35 ma max. Residual voltage: 0.7 V max.

Capacitive Proximity Sensor E2K-X

Chip Immune Inductive Prox E2EZ

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Photoelectric Sensor

BGS (at min. setting) BGS (at max. setting)

Capacitive Prox E2K-X

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Switching Power Supply

Capacitive Prox E2K-X

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

E2K-X4ME1 2M E2K-X4ME2 2M

I/O delay. (0.32 in ±0.06 in)

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Absolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Plastic Cylindrical Inductive Prox

Small-diameter Proximity Sensor E2E

(see note 1) --- E3G-MR19 block ON or OFF delay 0 to 5 s (adjustable) 0.2 to 2 m

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Outside. A pair of E32-T10V A combination of

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Capacitive Proximity Sensor E2K-C

Adjustable Capacitive Prox E2K-C

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX-E Series. Sensors

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Special-purpose Basic Switch

Compact Inductive Proximity Sensor

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block ---

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

2. Actuator B: Ball type P: Pin type F: Flat type

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

Solid-state Timer H3YN

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E3G. Photoelectric switch with built-in amplifier (long distance) in plastic housing. Features

Model Number Structure

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

E2K-C25MY1 E2K-C25MY2

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Long-distance Photoelectric Sensor

DC 2-wire Cylindrical Inductive Proximity Sensor

Model Number Structure

Ordering Information Absolute Rotary Encoders. Application Examples

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Photoelectric Sensor. Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor

D2SW-3L1HS D2SW-01L1HS

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

E2FM. Highly Durable Proximity Sensor for Tough Environments. Proximity Sensor with All-stainless Housing. Features

ZX-E Series. Ordering Information. Smart Sensors (Inductive Displacement Type) Sensors. High-accuracy Detection of Metal Workpiece Displacement

One-piece completely stainless-steel housing with a face thickness of 0.8 mm. 0.8 mm. Brush Test Continuous Impact Test Chemical and Detergent Proof

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

Transcription:

Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition to the, the new series of E2E/E2E2 models are available. Ideal for a variety of applications. With a metal connector that can be tightened securely and a cord protector. With an easy-to-see yellow indicator, deeper mounting holes, and tightening flats for wrenches. The new series of models includes M8 plug-in connector models. Note: Detailed information is available for the replacement of conventional models. Ask your OMRON representative for a copy of OMRON s /E2E/E2E2 Conversion Guide. Ordering Information DC 3-wire/Pre-wired Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO -X1R5C1 -X1R5B1 NC -X1R5C2 -X1R5B2 M12 2 mm NO -X2C1 -X2B1 NC -X2C2 -X2B2 M18 5 mm NO -X5C1 -X5B1 NC -X5C2 -X5B2 M30 10 mm NO -X10C1 -X10B1 NC -X10C2 -X10B2 Unshielded M8 2 mm NO -X2MC1 -X2MB1 NC -X2MC2 -X2MB2 M12 5 mm NO -X5MC1 -X5MB1 NC -X5MC2 -X5MB2 M18 10 mm NO -X10MC1 -X10MB1 NC -X10MC2 -X10MB2 M30 18 mm NO -X18MC1 -X18MB1 NC -X18MC2 -X18MB2 1

DC 3-wire/M12 Plug-in Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO -X1R5C1-M1 -X1R5B1-M1 NC -X1R5C2-M1 -X1R5B2-M1 M12 2 mm NO -X2C1-M1 -X2B1-M1 NC -X2C2-M1 -X2B2-M1 M18 5 mm NO -X5C1-M1 -X5B1-M1 NC -X5C2-M1 -X5B2-M1 M30 10 mm NO -X10C1-M1 -X10B1-M1 NC -X10C2-M1 -X10B2-M1 Unshielded M8 2 mm NO -X2MC1-M1 -X2MB1-M1 NC -X2MC2-M1 -X2MB2-M1 M12 5 mm NO -X5MC1-M1 -X5MB1-M1 NC -X5MC2-M1 -X5MB2-M1 M18 10 mm NO -X10MC1-M1 -X10MB1-M1 NC -X10MC2-M1 -X10MB2-M1 M30 18 mm NO -X18MC1-M1 -X18MB1-M1 NC -X18MC2-M1 -X18MB2-M1 DC 3-wire/M8 Plug-in Shield Size Sensing Output Part number distance configuration NPN PNP Shielded M8 1.5 mm NO -X1R5C1-M3 -X1R5B1-M3 Unshielded M8 2 mm NO -X2MC1-M3 -X2MB1-M3 2

Specifications Ratings/Characteristics -X C /B DC 3-wire Models Item -X1R5 C /B -X2M C /B -X2 C /B -X5M C /B -X5 C /B -X10M C /B Size M8 M12 M18 M30 -X10 C /B -X18M C /B Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance Supply voltage (operating voltage range) (see note) Current consumption Sensing object 1.5 mm ±10% 2 mm ±10% 2 mm ±10% 5 mm ±10% 5 mm ±10% 10 mm ±10% 10 mm ±10% 18 mm ±10% 12 to 24 VDC, ripple (p-p): 10% max., (10 to 40 VDC) 13 ma max. Magnetic metals (refer to Engineering Data for non-magnetic metals) Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm Standard object (mild steel) Differential travel 8 x 8 x 1 mm 12 x 12 x 1 mm 10% max. of sensing distance 12 x 12 x 1 mm 15 x 15 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm Response frequency 2.0 khz 0.8 khz 1.5 khz 0.4 khz 0.6 khz 0.2 khz 0.4 khz 0.1 khz Operation (with sensing object approaching) Control output (switching capacity) Circuit protection Indicator Ambient temperature C1/B1 models: C2/B2 models: ON OFF 200 ma max. 200 ma max. (300 ma max. at 55 C or less) NPN or PNP open collector Reverse connection protection, surge absorber, load short-circuit protection (yellow LED) Operating: 40 C to 70 C (with no icing) Ambient humidity Operating: 35% to 95% Temperature influence ±15% max. of sensing distance at 23 C in temperature range of 40 C to 70 C ±10% max. of sensing distance at 23 C in temperature range of 25 C to 70 C Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Residual voltage M8: 2.0 V max. (under load current of 200 ma with cable length of 2 m) M12 to M30: 2.0 V max. (under load current of 300 ma with cable length of 2 m) Insulation resistance Dielectric strength Vibration resistance 50 MΩ min. (at 500 VDC) between current carry parts and case 1,000 VAC for 1 min between current carry parts and case Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 (approx. 50G) for 10 times each in X, Y, and Z directions Enclosure rating IEC IP67 Destruction: 1,000 m/s 2 (approx. 50G) for 10 times each in X, Y, and Z directions 500 m/s 2 (approx. 50G) for E2E-X5M Weight Pre-wired Approx. 45 g Approx. 120 g Approx. 160 g Approx. 270 g Connector --- Approx. 25 g Approx. 45 g Approx. 125 g Approx. 124 g Material Case Stainless steel Brass Sensing surface PBT Note: models with an M18 or M30 connector operate at a non-smoothed, all-wave rectified, mean voltage range of 24 VDC ±20%. 3

Engineering Data Operating Range (Typical) Shielded Models -X C /B -X C /B Sensing distance X (mm) E2E -X2 Sensing distance X (mm) E2E -X10 E2E -X1R5 E2E -X5 Y (mm) Y (mm) Unshielded Models -X MC /B -X MC /B Sensing distance X (mm) E2E -X5M Sensing distance X (mm) E2E -X18M E2E -X2M E2E -X10M Y (mm) Y (mm) 4

Sensing Distance vs. Sensing Object (Typical) -X1R5C /B -X2C /B -X5C /B t = 1 mm t = 1 mm Sensing distance (mm) Brass Aluminum Mild steel Stainless steel (SUS304) Sensing distance (mm) Mild steel Stainless steel (SUS304) t = 1 mm Brass Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) -X10C /B -X2MC /B -X5MC /B t = 1 mm Sensing distance (mm) t = 1 mm Mild steel Stainless steel (SUS304) Brass Aluminum Sensing distance (mm) t = 1 mm Mild steel Stainless steel (SUS304) Brass Copper Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) -X10MC /B -X18MC /B Mild steel t = 1 mm Sensing distance (mm) t = 1 mm Stainless steel (SUS304) Brass Aluminum Sensing distance (mm) Mild steel Stainless steel (SUS304) Aluminum Brass Side length of sensing object d (mm) Side length of sensing object d (mm) 5

Operation Output Circuits -X C NPN Open Collector Output Brown -X B PNP Open Collector Output Brown 100 Ω Main circuit Black Output Main circuit Black Blue 0 V 100 Ω Blue 0 V Operating Chart -X C /B NPN/PNP Open Collector Output Sensing object Red indicator Control output Yes No Lit Not lit ON OFF 6

Dimensions Note: All units are in millimeters unless otherwise indicated. Type Part number DC 3-wire Pre-wired Shielded M8 -X1R5C /B 1 M12 -X2C /B 3 M18 -X5C /B 5 M30 -X10C /B 7 Unshielded M8 -X2MC /B 2 M12 -X5MC /B 4 M18 -X10MC /B 6 M30 -X18MC /B 8 Connector (M12) Shielded M8 -X1R5C -M1/B -M1 9 M12 -X2C -M1/B -M1 11 M18 -X5C -M1/B -M1 13 M30 -X10C -M1/B -M1 15 Unshielded M8 -X2MC -M1/B -M1 10 M12 -X5MC -M1/B -M1 12 M18 -X10MC -M1/B -M1 14 M30 -X18MC1-M1/B1-M1 16 Connector (M8) Shielded M8 -X1R5C1-M3/B1-M3 17 Unshielded -X2MC1-M3/B1-M3 18 Figure no. 7

Pre-wired Models (Shielded) Fig. 1 : -X1R5C /B Pre-wired Models (Unshielded) Fig. 2 : -X2MC /B 15 dia. 15 dia. Operation M8 x 1 indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores 6.1 dia. M8 x 1 Operation indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores Fig. 3 : -X2C /B Fig. 4 : -X5MC /B 21 dia. 21 dia. Operation indicator Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores 9 dia. Operation indicator Two clamping nut Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 3 cores Fig. 5 : -X5C /B Fig. 6 : -X10MC /B 29 dia. 29 dia. Operation M18 x 1 indicator Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 14.8 dia. M18 x 1 Operation indicator Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores Fig. 7 : -X10C /B Fig. 8 : -X18MC /B 42 dia. 42 dia. M30 x 1.5 Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 26.8 dia. M30 x 1.5 Operation indicator Two clamping nut Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 3 cores 8

Connector Models (Shielded) Connector Models (Unshielded) Fig. 9 : -X1R5C -M1/B -M1 Fig. 10 : -X2MC -M1/B -M1 15 dia. 15 dia. M8 x 1 6.1 dia. M8 x 1 Fig. 11 : -X2C -M1/B -M1 Fig. 12 : -X5MC -M1/B -M1 21 dia. 21 dia. 9 dia. Fig. 13 : -X5C -M1/B -M1 Fig. 14 : -X10MC -M1/B -M1 29 dia. 29 dia. M18 x 1 14.8 dia. M18 x 1 Fig. 15 : -X10C -M1/B -M1 Fig. 16 : -X18MC -M1/B -M1 42 dia. 42 dia. 26.8 dia. M30 x 1.5 M30 x 1.5 9

M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Fig. 17 : -X1R5C1-M3/B1-M3 Fig. 18 : -X2MC1-M3/B1-M3 15 dia. M8 x 1 15 dia. M8 x 1 M8 x 1 6.1 dia. M8 x 1 Mounting Holes F Dimensions 4 dia. M5 5.4 dia. M8 M12 M18 M30 F (mm) 4.2 +0.5 / 0 dia. 5.5 +0.5 / 0 dia. 5.7 +0.5 / 0 dia. 8.5 +0.5 / 0 dia. 12.5 +0.5 / 0 dia. 18.5 +0.5 / 0 dia. 30.5 +0.5 / 0 dia. 10

Installation Connection -X C DC 3-wire Models Brown Black Blue 24 VDC Pin Arrangement -X C /B -M1/M3 Connector Output configuration Applicable models M12 NO -X C1-M1 Pin arrangement Note: Terminal 2 is not used. -X B1-M1 Note: Terminal 2 is not used. NC -X C2-M1 Note: Terminal 4 is not used. -X B2-M1 Note: Terminal 4 is not used. M8 NO -X C1-M3 Note: Terminal 2 is not used. -X B1-M3 Note: Terminal 2 is not used. 11

Precautions Mounting Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Unshielded Model Note: The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. Type Part A Part B Length Torque Torque M8 Shielded 9 mm 9 N m 12 N m Unshielded 3 mm (91 kgf (120 kgf cm) cm) M12 30 N m (310 kgf cm) M18 M30 70 N m (710 kgf cm) 180 N m (1,800 kgf cm) Part B Part A Part B Part A Effects of Surrounding Metal When mounting the within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. d dia. Type Item M8 M12 M18 M30 -X C Shielded 0 mm 0 mm 0 mm 0 mm -X B d 8 mm 12 mm 18 mm 30 mm DC 3-wire D 0 mm 0 mm 0 mm 0 mm m 4.5 mm 8 mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm Unshielded 6 mm 15 mm 22 mm 30 mm Relationship between Screw Sizes and Models Type Part number M8 Shielded -X1R5C /B Unshielded d 24 mm 40 mm 55 mm 90 mm D 6 mm 15 mm 22 mm 30 mm m 8 mm 20 mm 40 mm 70 mm n 24 mm 36 mm 54 mm 90 mm -X2MC /B M12 Shielded -X2C /B Unshielded -X5MC /B M18 Shielded -X5C /B Unshielded -X10MC /B M30 Shielded -X10C /B Unshielded -X18MC /B 12

Mutual Interference When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. A B Type Item M8 M12 M18 M30 -X C Shielded A 20 mm 30 mm 50 mm 100 mm -X B B 15 mm 20 mm 35 mm 70 mm DC 3-wire Unshielded A 80 mm 120 mm 200 mm 300 mm B 60 mm 100 mm 110 mm 200 mm! Caution Power supply Item Do not impose an excessive voltage on the, otherwise it may explode or burn. Do not impose 100 VAC on any DC model, otherwise it may explode or burn. Sensor Brown Blue Black Incorrect Examples short-circuit Do not short-circuit the load, or the may explode or burn. The s short-circuit protection function is valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Brown Sensor Blue Black Incorrect Wiring Be sure to wire the and load correctly, otherwise it may explode or burn. Brown Sensor Blue Black Incorrect Sensor Brown Black Blue Incorrect Connection with no load Make sure to connect a proper load to the in operation, otherwise it may explode or burn. Sensor Brown Blue Incorrect Correct Use Installation Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Object Metal Coating: The sensing distances of the Proximity Sensor vary with the metal coating on sensing objects. Wiring High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cord of the Proximity 13

Sensor, wire the cord through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cord Tractive Force Do not pull cords with the tractive forces exceeding the following. Diameter Tractive force 4 dia. max. 30 N max. 4 dia. min. 50 N max. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Connection type Method Description AND (serial connection) OR (parallel connection) Correct Correct The Sensors connected together must satisfy the following conditions. i L + (N 1 ) x i Upper-limit of control output of each Sensor V S N x V R operating voltage N: No. of Sensors V R : Residual voltage of each Sensor V S : Supply voltage i: Current consumption of the Sensor i L : current If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. A minimum of three Sensors with current outputs can be connected in parallel. The number of Sensors connected in parallel varies with the Proximity Sensor model. 14

15

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D060-E1-1 OMRON Corporation Industrial Sensors Division Sensing Devices and Components Division H.Q. 28th Fl., Crystal Tower Bldg., 1-2-27, Shiromi, Chuo-ku, Osaka 540-6028 Japan Phone: (81)6-949-6012 Fax: (81)6-949-6021 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0998-1M (0796) 16