C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

Similar documents
ic60n RCBO 30 ma IEC , IEC , AS/NZS

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

C60 multi-standard range

Section 4 Ground-Fault Protection Devices

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

ict contactors EN 61095, IEC 1095 Interference

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

TeSys IEC Contactors and Overload Relays

1492-SP Supplementary Protectors

Supplementary Circuit Protectors Type GSB63

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

em4 Accessories Digital expansions

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Multifunction

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

60103 Circuit Breaker

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Horizontal distribution busbar HX 3 80/125 A plug-in

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

RB60 RANGE. Miniature circuit breakers

Datasheet - SRB 402EM-24V

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

the Santon FCS-type switch Disconnect Superior Switch Solutions

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Type of surge arrester

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

Description. Installation. Power supply

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Safety switches for hinged doors

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MOTOR & CIRCUIT PROTECTION

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

Motor protection circuit breakers

Allen-Bradley 1492-RCDA4A40

Motor protection circuit breakers

UL 489 DIN Rail Miniature Circuit Breakers

C60 UL 489 / CSA C22.2 No IEC / GB

Redundancy unit CP-A RU

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

3 Pole Contactors with AC operating coils

Datasheet - SRB 301LC/B-24V

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Residual Current Devices drcm Digital

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

EMS CX 3 - State and control module for Latching relays and Contactors

UL 489 DIN Rail Miniature Circuit Breakers

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue

DC-Switch With G20S/G20. next

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

WEG Contactors - CWM and CWME Series

SIRCO Load break switches for power distribution from 125 to 5000 A

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Power supply CP-C 24/5.0

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Thermal-Magnetic Circuit Breaker 2216-S

MULTI 9 System Catalog

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

Power supply CP-C 24/5.0

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Air Circuit Breaker (ACB)

Tongue Switches Trojan 5 & 6

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

MULTI 9 System Catalog

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

DSE201, DSE201 M Compact design with enhanced protection

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Nemo SX - Multifunction control module

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Electronic timer CT-ARS.11

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Datasheet SRB301ST 24V (V.2)

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Safety switches with separate actuator

Overvoltage Protection Devices

Safety switches with separate actuator

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Electronic timer CT-AHD.22

EMS CX 3 - State and control module for Latching relays and Contactors

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Transcription:

DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram). Combined with a switch (of the C60NA-DC type, for example), the C60PV-DC will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter. C60PV-DC can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the C60PV-DC with: b a residual current device at the AC end, b a fault passage detector (insulation monitoring device) at the DC end b an earth protection circuit breaker at the DC end (see Practical Advice CA908035). In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). C60PV-DC is not polarity sensitive: (+) and (-) wires can inversed without any risk. The C60PV-DC is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-2 e DB404840 Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) 1.5 ka Impulse voltage (Uimp) 6 kv Electrical connection By the bottom for In and Out Number of poles 2P Number of modules of 9 mm 8 Diagrams DB122506 DB122703 IN IN OUT OUT 1 3 2 4 IN OUT 1 3 2 4 1 3 2 4 Standards IEC 60947-2 EN 60947-2 Rating (A) Catalogue numbers 1 A9N61653 2 A9N61654 3 A9N61655 5 A9N61656 8 A9N61657 10 A9N61650 13 A9N61658 15 A9N61659 16 A9N61651 20 A9N61652 25 A9N61660 Auxiliaries See modules CA907008 and CA907013 108 Version : 1.2 06/06/2013 CA901031E

DC circuit supplementary protectors for photovoltaic C60PV-DC (cont.) Application diagram DB404621 String PV protection enclosure Photovoltaic string modules PV Inverter protection enclosure PV Inverter PV Inverter protection enclosure PV Inverter MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC CA901031E Version : 1.2 06/06/2013 109

DC circuit supplementary protectors for photovoltaic C60PV-DC (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN 60947-2 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Main characteristics Rated service breaking capacity (Ics) 100 % of the Icu Endurance (O-C) Electrical 1,500 cycles (where L/R=2 ms) Mechanical 20,000 cycles Mechanical Degree of pollution 2 Category Tropicalisation 20,000 cycles Temperature Operating -25 C to 70 C Storage -40 C to 85 C A (no delay in accordance with IEC / EN 60947-2 standards) Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) 1 9200 9200 9.2 2 5104 2552 10.2 3 2980 993.3 8.9 5 2000 400 10 8 1384 173 11.1 10 680 68 6.8 13 572 44 7.4 15 600 40 9 16 648 40.5 10.4 20 588 29.4 11.8 25 488 19.5 12.2 Derating table (A) C60PV-DC Ambient temperature ( C) Rating -30-25 -20-15 -10-5 0 +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +55 +60 +65 +70 1 A 1.18 1.17 1.15 1.14 1.12 1.1 1.09 1.07 1.05 1.04 1.02 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 0.84 0.82 2 A 2.54 2.5 2.45 2.41 2.36 2.31 2.26 2.21 2.16 2.11 2.06 2 1.94 1.88 1.82 1.76 1.7 1.63 1.56 1.48 1.41 3 A 3.78 3.71 3.65 3.58 3.51 3.45 3.38 3.3 3.23 3.16 3.08 3 2.92 2.84 2.75 2.66 2.57 2.48 2.38 2.27 2.17 5 A 6 5.92 5.83 5.74 5.66 5.57 5.48 5.39 5.29 5.2 5.1 5 4.9 4.8 4.69 4.58 4.47 4.36 4.24 4.12 4 8 A 9.64 9.5 9.36 9.22 9.08 8.93 8.78 8.63 8.48 8.32 8.16 8 7.83 7.67 7.49 7.31 7.13 6.95 6.76 6.56 6.36 10 A 12.6 12.4 12.2 11.9 11.7 11.5 11.2 11 11.8 10.5 10.3 10 9.7 9.4 9.2 9.9 8.6 8.2 7.9 7.6 7.2 13 A 15.5 15.3 15.1 14.8 14.6 14.4 14.2 14 13.7 13.5 13.2 13 12.7 12.5 12.2 12 11.7 11.4 11.1 10.8 10.5 15 A 18.6 18.3 18 17.7 17.4 17.1 16.7 16.4 16.1 16.7 15.4 15 14.6 14.3 13.9 13.5 13.0 12.6 12.2 11.7 11.2 16 A 19.4 19.1 18.9 18.6 18.3 18.0 17.6 17.3 17.0 16.7 16.3 16 15.7 15.3 14.9 14.6 14.2 13.8 13.4 13.0 12.5 20 A 24.1 23.7 23.4 23.0 22.7 22.3 21.9 21.6 21.2 20.8 20.4 20 19.6 19.2 18.7 18.3 17.9 17.4 16.9 16.4 15.9 25 A 30.4 29.9 29.5 29.0 28.5 28.1 27.6 27.1 26.6 26.1 25.5 25 24.5 23.9 23.3 22.7 22.1 21.5 20.9 20.2 19.6 110 Version : 1.2 06/06/2013 CA901031E

DC circuit supplementary protectors for photovoltaic C60PV-DC (cont.) Technical data (cont.) Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the C60PV-DC protective devices to provide greater insulation of the terminal screws b a spacer clips 9 mm in each side to provide isolation. DB404478 DB404479 DB404480 d Required to have a 9 mm space isolation in each side" 9 mm mini 9 mm mini Weight (g) Circuit breaker Type C60PV-DC 545 DB405613 Dimensions (mm) DB122701 Connection Rating Tightening torque Without accessory With accessories Copper cables UL 486A 50 mm 2 Cu/Al Terminal Ring tongue terminal screw connection Rigids Flexibles with ferrule PZ2 14 mm 6.5 mm DB112804 DB112805 DB118755 DB118756 y 25 A 2.5 N.m 1 to 25 mm 2 1 to 16 mm 2 50 mm 2 Ø 5 mm CA901031E Version : 1.2 06/06/2013 111

C60NA-DC PB108404-50 The C60NA-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the string of photovoltaic modules and the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the C60PV-DC type, for example), the C60NA-DC will be installed in a string PV protection enclosure close to the strings of photovoltaic modules. It can also be installed near the PV inverter. It can be locked (by a padlocking device) in OFF position to ensure safety during maintenance operations. the C60NA-DC can switch a multi-directional current. C60NA-DC is not polarity sensitive: (+) and (-) wires can inversed without any risk. The C60NA-DC is delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-3 e DB404841 Main characteristics Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB122506 20 A: 1000 V CC 32 A: 800 V CC 50 A: 700 V CC 1,000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P 1 3 2 4 1 3 2 4 DB122704 1 3 2 4 IN OUT IN IN OUT OUT Standards IEC 60947-3 EN 60947-3 Catalogue number Auxiliaries A9N61690 See modules CA907008 and CA907013 112 Version : 1.2 06/06/2013 CA901032E

C60NA-DC (cont.) Application diagram DB404622 String PV protection enclosure Photovoltaic string modules Diagram with C60NA-DC for current y 20 A PV Inverter protection enclosure PV Inverter Diagram with SW60-DC for current between 20 and 50 A PV Inverter protection enclosure PV Inverter *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901032E Version : 1.2 06/06/2013 113

C60NA-DC (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Main characteristics Endurance (O-C) Electrical 1,500 cycles Mechanical Degree of pollution 2 Category Tropicalisation 20,000 cycles DC21B Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Derating table (A) C60NA-DC Ambient temperature ( C) Rating +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +60 +70 50 A 63 61 60 58 56 54 52 50 48 46 41 35 Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the C60NA-DC protective devices to provide greater insulation of the terminal screws b a Spacer clips 9 mm in each side to provide isolation. DB122714 DB122713 DB122715 9 mm mini 9 mm mini d Required to have a 9 mm space isolation in each side" 114 Version : 1.2 06/06/2013 CA901032E

C60NA-DC (cont.) Technical data (cont.) Weight (g) Dimensions (mm) Switch disconnector Type C60NA-DC 530 DB122712 DB122701 Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal Screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB112804 DB112805 DB118755 DB118756 DB118757 50 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901032E Version : 1.2 06/06/2013 115

Switch SW60-DC PB108406-50 The SW60-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the C60PV-DC type, for example) and a switch (of the C60NA-DC type, for example), the SW60-DC will be installed in the string PV protection enclosure close to the PV inverter (see application diagram). It can be locked (by a padlocking device) in OFF position to ensure safety when removing the PV inverter. SW60-DC is polarity sensitive: (+) and (-) has to be respected for connection. The SW60-DC is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN 60947-3 e DB404842 General technical data Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB122699 1000 V DC 1000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P DB122700 1 2 + 4 + 3 IN OUT OUT IN 1 2 4 3 1 2 4 3 IN OUT OUT IN Standards IEC 60947-3 EN 60947-3 Catalogue number A9N61699 116 Version : 1.1 06/06/2013 CA901030E

Switch SW60-DC (cont.) Applications DB404639 String PV protection enclosure Photovoltaic string modules Diagram with SW60-DC for current between 20 and 50 A PV Inverter protection enclosure PV Inverter *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901030E Version : 1.1 06/06/2013 117

Switch SW60-DC (cont.) Technical data Main characteristics b Position contact indication - suitability for isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Endurance (O-C) Electrical 1,500 cycles Mechanical Degree of pollution 2 Category Tropicalisation 20,000 cycles DC21A Temperature Operating -25 C to 70 C Storage -40 C to 85 C Rating adjustment 40 C Relative humidity: 95 % at 55 C in accordance with IEC 60068-2 and GB 14048.2 standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) 50 A 251 5.02 12.54 Derating table (A) SW60PV-DC Ambient temperature ( C) Rating +5 +10 +15 +20 +25 +30 +35 +40 +45 +50 +60 +70 50 A 63 61 60 58 56 54 52 50 48 46 41 35 Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the SW60-DC protective devices to provide greater insulation of the terminal screws. b a Spacer clips 9 mm in each side to provide isolation. DB122722 DB122723 DB122724 d 9 mm spacers must be used on both sides of the device to create a local ventilation space around the product. 9 mm mini 9 mm mini d Failure to match polarity during connection may lead to a fire hazard and/or serious injury. The connection polarity must be observed (marked on the front panel). Use only with direct current. 118 Version : 1.1 06/06/2013 CA901030E

Switch SW60-DC (cont.) Technical data (cont.) Weight (g) Dimensions (mm) Switch disconnector Type SW60-DC 530 DB123703 Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB112804 DB112805 DB118755 DB118756 DB123702 DB118757 50 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901030E Version : 1.1 06/06/2013 119