Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

Similar documents
Measurement and Management Technologies (MMT)

Innovative Data Center Energy Efficiency Solutions

18 th National Award for Excellence in Energy Management. July 27, 2017

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Center Infrastructure Management (D.C.I.M.)

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Optimizing Cooling Performance Of a Data Center

Recapture Capacity for Existing. and Airflow Optimization

MSYS 4480 AC Systems Winter 2015

Green IT and Green DC

Power Monitoring in the Data Centre

Efficiency of Data Center cooling

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

MEASURE MONITOR UNDERSTAND

Maximising Energy Efficiency and Validating Decisions with Romonet s Analytics Platform. About Global Switch. Global Switch Sydney East

RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

EDX DC-3 environmental monitoring solution

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

DCIM Data Center Infrastructure Management

CyrusOne Case Study About CyrusOne

Comprehensive Data Center Energy Management Solutions

Power and Cooling for Ultra-High Density Racks and Blade Servers

DCIM Data Center Infrastructure Management Measurement is the first step

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

84 kw, Tier 3, Direct Expansion, 937 ft 2

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Impact of Air Containment Systems

Energy Efficient Data Centers

Building Management Solutions. for Data Centers and Mission Critical Facilities

Virtualization and consolidation

Data Center Infrastructure Management ( DCiM )

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Committed to Energy Efficiency

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Rockwell Automation ODVA Annual Meeting

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

DATA CENTER AIR HANDLING COOLING SOLUTIONS

WIRELESS ENVIRONMENTAL MONITORS

Rittal Cooling Solutions A. Tropp

Data Center Energy Savings By the numbers

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

ECOBAY: Closed loop water cooled server cabinet for data centers

HP Rack Thermal Sensor Monitoring Solution

Reducing Data Center Cooling Costs through Airflow Containment

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

1.0 Executive Summary. 2.0 Available Features & Benefits

Tridium - Introduction

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

How High-Density Colocation and Enhanced Visibility Improve Business Performance

A Green Approach. Thermal

Chiller Replacement and System Strategy. Colin Berry Account Manager

The Energy. David L. Moss Dell Data Center Infrastructure

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

Thermal management. Thermal management

APC APPLICATION NOTE #74

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

1008 kw, Tier 2, Chilled Water, ft 2

INNOVATE DESIGN APPLY.

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

ROI CASE STUDY MAY Logicalis Achieves 159% ROI* with CA DCIM Solution

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

INNOVATE DESIGN APPLY.

Data Center Infrastructure Management (DCIM) Demystified

Data Center Optimized Controls

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Driving Business Value through Enterprise Agreements and Partnering

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Leveraging DCIM to Increase Energy Efficiency and Savings

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Data Center Lifecycle and Energy Efficiency

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

Switch to Perfection

Application of TileFlow to Improve Cooling in a Data Center

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

Green Data Centers A Guideline

DC Energy, Efficiency Challenges

Jack van der Horst, Regional Technology Manager, Asia Pacific. ABB

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance

Raytheon s Strategic IT Energy and Resource Management Program

Overcoming the Challenges of Server Virtualisation

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Simple, fast data acquisition and transfer for big data analytics

Regional Seminar Series. Critical Facilities, Data Center,& IT

ANCIS I N C O R P O R A T E D

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

System architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,

Transcription:

Information and Communication Technology Portfolio Review San Francisco, CA March 2011 Project Name: Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities Lead organization: IBM T.J Watson Research Center PI (or PIs): Hendrik F. Hamann, David E. Seeger Partners Georgia Institute of Technology: Technology Development Partner AT&T: Field Experiment Partner Project start and completion dates 04/01/2010 03/31/2012 Project type Field experiment (Demonstration) Hendrik F. Hamann / 1

Background Scalability and Metrics Each DC is unique (business requirements, IT components, facilities etc.) DCs include very diverse technology components: (power delivery, power and facilities management, cooling technologies, IT core technology) Most of today s solutions apply only to subset of the problem DC market is highly fragmented, which has prevented technology scaling. Meaningful metrics for DC Efficiency are not easily obtainable E.g., DCIE metric can be problematic: DCIE is weather-, location-, application-,tier dependent non-linear, awards UPS consumption (IT power usage) DCIE is often insufficient for proving and managing energy efficiency Because of lack of meaningful metrics $ savings are difficult to prove and investments do not have a clear business case Hendrik F. Hamann / 2

Background Risks and Integration Energy efficiency improvements have to be manageable without compromising reliability of the operation Current DC monitoring/management solutions and modeling tools are limited in their ability to provide dependable insights DCs lack generally manageability and visibility to improve efficiency without increasing risk Today, most energy efficient technologies do not offer a clear pathway towards such integration but rather proprietary software and architectures. Integration has to include the underlying IT technology, energy and thermal management, power delivery technologies as well as cooling and facilities. Significant energy efficiency improvements will originate from integrating over the different technology components, which will enable a much more holistic management approach. Hendrik F. Hamann / 3

Project Objectives Development, Demonstration, and Commercialization of a DC Measurement and Management Technology (MMT) 1. Development: Complement DC Sensing and Measuring Technologies: Ultra-sensitive and inexpensive corrosion sensors Retrofit-able, circuit-level power monitoring Enhance Modeling Technologies: CFD models for operational decision support and continued control Statistical and reduced-order real-time heat transfer models Software / Management: Integrate other data sources (weather, IT, facility, BMS, assets) Develop various control algorithms for best practices, ACU, set point and free control controls and power management Transfer technology to IBM Maximo product Hendrik F. Hamann / 4

Project Objectives Development, Demonstration, and Commercialization of a DC Measurement and Management Technology 2. Field Testing: Deploy MMT at several different sites throughout US Legacy DC, Enterprise DC, VHO (Video Hub Office), MTSO (Mobility Telephone Switching Office), CO (Central Office), Cell phone Tower DCIE of 0.8 at one site and 12.5% improvement for all remaining tests Demonstrate 5 control schemes (controls for best practices, ACU, set point, free cooling and power management) Demonstrate open integration of MMT with other data sources Demonstrate fast energy savings (50 % after 9 M and 100 % after 18 M) 3. Commercialization: Productize MMT through IBM s Software and Service Groups Commercialize sensor-related technologies with business partners Drive business with internal WW deployment Hendrik F. Hamann / 5

What is MMT? (Data Center) Measurement and Management Technology: Real-time and high resolution Measurements Measurement-based Modeling Management and Control Hendrik F. Hamann / 6

MMT - Approach High level of applicability to meet requirements of different types of DCs so technology can be scaled A real-time and high resolution measurement system including IT sensors to quantify energy savings so business cases can be supported. Measurement-based, real-time modeling to provide maximum visibility to manage energy efficiency without increasing risk. Control technologies for best practices, ACU utilization and fans, set points of chilling systems, free cooling as well as power management for optimum energy efficiency. An open architecture to integrate with facilities, BMS, IT, power delivery devices and other DC tools to provide a holistic end-to end management solution. Provide rapid energy saving opportunities in the short-term but also continued energy efficiency improvements as IT efficiency increases. Hendrik F. Hamann / 7

Corrosion Management One of the main inhibitor for Air-side economization is corrosion risk Developed a high sensitivity corrosion management system Sensitivity of 1 A o per day corrosion rate (equals 1 atomic layer) 10 x more sensitive than any commercial sensor system allows remote real-time corrosion monitoring Technology can access corrosion risk based on indoor and out door environmental with the goal to optimize free cooling technologies Corrosion Monitoring Hardware Corrosion GUI Real-time Corrosion Monitoring Hendrik F. Hamann / 8

Power Management developed a low cost, multiplexing, retrofit-able PDU power monitoring solution based on Hall sensing of the magnetic field 4x42 Hall sensors are deployed in a single PDU to monitor current of each circuit without disconnecting IT equipment Gateway gathers all data and communicates with MMT server for power management analytics MMT SW visualizes and manages full power chain (from PDU to server) and then relations Alarm system to warn about increased power/current limits on each circuit to optimally utilize existing power infrastructure Hendrik F. Hamann / 9

MMT Adapters - New Data Sources AEM (IT-Metrics) PI / OSISOFT MMT Server Open API OPC (BMS) New Adapters Maps Weather Autocad db2 mysql SMNP etc. Hendrik F. Hamann / 10

CFD Physics-based Models (Base Models) Optimized PDE solver has been developed and implemented Benchmark show excellent accuracy Real measurements (air flow values, temperatures) are leveraged to simply model description c v T ( k T ) h Temperature and flow measurements are directly fed into PDE as boundaries Superposition p principles is leveraged for racks faster models 3D version of this technology has been deployed and runs hourly for several projects Hendrik F. Hamann / 11

Statistical Models (Dynamic Models) CFD models are complemented with statistical and/or reduced order models Models leverage reduced order representation of thermal profiles (s-curves) S-curves are fed as z-trend into 3D kriging for temperature forecasting Models include fundamental physics principles such as energy balance z [feet] Hendrik F. Hamann / 12

MMT Management Software MMT Software Features detailed ways to manage data center by an MMT layout editor real-time, 3D temperature, humidity, pressure distributions efficiencies in real-time and corresponding cooling zones reports and energy efficiency summaries Available in Maximo for Energy optimization (MEO) as a product or as a GTS service https://researcher.ibm.com/mmt2/launch.htm Hendrik F. Hamann / 13

Heat Distribution Analytics Heat Map Layer Real-time temperature Combination of measurement, base and dynamic model provides near real-time 3D temperature distribution Other Analytics: Humidity, DewPoint, Risk, Cooling Power, Air flow Hendrik F. Hamann / 14

Power Map Analytics Power Map Layer Real-time rack power ~ 713 W Circuit-level monitoring and MMT data model allows exploiting relationship between 12000 sensors (voltage/current/kva,power factor) and rack power delivery to derive power maps of a complete data center Hendrik F. Hamann / 15

Cooling Zone Analytics Zone Map Layer Perforated Tiles ACU Zone boundaries Zone is 38 % efficient ACU turned off Bar heights indicate efficiency of respective zones Hendrik F. Hamann / 16

MMT Controls: ACUs BEFORE: ACU Power Consumption = 11.5 kw (ACU#1 @ 100% + ACU#2 @ 100 % = 24800 cfm) Inlet Temperature Histogram # of occurances max. Temp. MMT Sensor and control network Inlet temps [F] AFTER: ACU Power Consumption = 3.5 kw (ACU#2 @ 84 % = 10416 cfm) Inlet Temperature Histogram Variable capacity AC unit (ACU) 51.1 F 93.2 F # of occurances lower temps with less energy Inlet temps [F] max. Temp. >2x reduction in (ACU) cooling power with no impact on inlet temperatures MMT includes both VFD and ON/OFF ACU Controls Hendrik F. Hamann / 17

Energy Savings MMT @ Work: Saving Predictions: In > 100 deployments of MMT base technology an average of > 10 % savings was achieved Nationwide deployment results in assuming - 7 GW for DCs + 2 GW for COs/Teleco spaces: - 50 % applicability - 50 % market acceptance - 10 % of savings 2 billion kw hours annually (@ 9 GW base) l

Project Status Field Testing General Site Info Technologies MMT Controls Power Management Free Cooling Control Set point Control ACU Control (fan speed) ACU Control (utilization) Best Practices Control Circuit level monitoring Air side economizer Plate frame VFD Chiller system Field test area [k square feet] Facility Type Classical DC Enterprise DC 130 CP x x x x x x 70 CP x x VHO 4 DX x x x x x x x MTSO 22 CP x x x x x x x Central Office 36 CP x x x x x All field tests have started and are on target Hendrik F. Hamann / 20

What s left and what happens after Sponsorship? Finish all outstanding technical work and field test R&D work: 40 % Field Testing: 50 % Commercialization: 60 % Scale technology IBM internal deployment (8M square feet) target large customers and project partners Continue to transfer technology and integrate technology with IT management Tivoli monitoring, Acitve Energy Manager Cloud technologies (xcat etc.) Drive additional commercialization through IBM and partners Expand technology to adjacent spaces Hendrik F. Hamann / 21

Summary MMT is a technology which addresses current inhibitors for DC energy efficiency improvements Scalable and thus will be an inexpensive technology Measurement-based, quantitative to support clear business objectives provides maximum visibility to manage risk associated with efficiency improvements Integrateable with other technologies (especially IT technologies) and thus expandable Main Highlights Corrosion and Power Chain Management Operational CFD and real-time modeling Unique analytics including physical ACU cooling zones and efficiencies Supports 6 main control technologies including VFD Control Integrated with BMS and IT monitoring tools Hendrik F. Hamann / 22

Back - up Hendrik F. Hamann / 23

Project Status Core Technologies Low power high resolution wireless sensor platform developed. Developed high sensitivity, low cost corrosion management system System allows remote real-time corrosion monitoring to enable free cooling Low cost, multiplexing, retrofit-able PDU power monitoring solution developed. MMT visualizes and manages full power chain (from PDU to server) Operational CFD modeling implemented using an optimized PDE solver Measurement points feed boundary conditions CFD models have been complemented with real-time statistical and reduced order models Hendrik F. Hamann / 24

Project Status Energy Management Software Platform for control and DC management developed and productized Maximo for Energy Optimization: Release 7.1.1 (ega - Sept 17,2010) Includes heat, pressure, flow, utilization, power, cooling analytics, ACU cooling Additional data sources integrated: Assets, Autocad BMS, OPC, OSISoft IT, Tivoli, AEM MMT Sensor and control network ACU Control algorithms developed and tested: >2x reduction in (ACU) cooling power with no impact on inlet temperatures MMT includes both VFD and ON/OFF ACU Controls Variable capacity AC unit (ACU) Hendrik F. Hamann / 25

IBM Data Center IBM delivery centers Client centers managed by IBM Data Centers Square Feet (millions) Data Centers Square Feet (millions) Americas 90 2.0 Americas 107 2.8 Asia Pacific 42 1.2 Asia Pacific 85 0.8 Europe 85 0.6 TOTAL 217 3.8 Europe 53 0.6 TOTAL 245 4.2 Global at-aglance Up to 470 data centers +8 million square feet of space 1,291 Mainframes 1,144,430 MIPS 11,028 Terabytes 207,148 Mid Range Servers 3,775,388 equipped user seats 5 million square feet of work area space Data as 6/30/2009 Hendrik F. Hamann / 26

MMT Sensing and Measurements Detailed, high resolution assessment and survey data (MMT 1.0) Robotic 3D dimensional mapping tools for detailed environmental measurements Adapters to existing data sources (BMS, asset db) Real-time sensing networks (MMT 1.5) External and internal (via AEM, ITMfEM) Wireless and wired solutions Sensor grid solution with 1-wire protocol access points every 2 for thermal, flow, acoustics, pressure (all with the same network) Corrosion, power sensors are being developed MMT provides both high time & spatial resolution combining High resolution measurements / assessments for base model generation, sensor placement etc. Real-time sensing for feeding dynamic models Hendrik F. Hamann / 27

MMT Sensing and Measurements DoE Activities 1. Real-time Corrosion Management 2. Remote Power Monitoring 3. An Ultralow Power MMT Wireless Sensor Platform Hendrik F. Hamann / 28

WW Large-scale Sensor Deployments TYPICAL DEPLOYMENT 4300 thermal sensors 250 pressure sensors 612 flow sensors 300 humidity sensors 12000 power/current sensors Pull data every 2 mins Installs in all Geos: EMEA, Americas, AP Hendrik F. Hamann / 29

Pressure Distribution Analytics Pressure Layer Real-time Plenum Pressure 2.2 Pa Network of pressure sensors allows modeling of pressure fields Hendrik F. Hamann / 30

Air Flow Analytics Air flow Layer Real-time Perforated Tile Flow ~ 399 cfm Combination of pressure fields with tile impedances yield air flow values Hendrik F. Hamann / 31

Cooling Power Analytics Cooling Power Map Layer Real-time cooling power ~ 1513 W Analytics provides cooling power distribution (how much cooling power is provided where.) Exact match of cooling power to IT power will provide optimum energy efficiency Hendrik F. Hamann / 32

MMT - Integration: AEM, ITMfEM, Maximo Delivering key energy management metrics through an integrated solution Centralized Energy Views MMT Analytics and Visualization Role-based energy dashboard Control & Power Management IBM Director Active Energy Manager IBM Maximo Asset Manager for Energy Optimization IBM Tivoli Business Service Manager (optional) IBM Tivoli Monitoring for Energy Management Energy Reporting INFORMATION TECHNOLOGY FACILITIES & PROPERTY ASSETS Hendrik F. Hamann / 33

MMT in Maximo for Energy Optimization Hot and Cold Spots Thermal Zones MEO has released a new version of the product, Release 7.1.1 (ega - Sept 17,2010) Implemented a development architecture for the MEO development team to consume MMT features. Real-time collection of sensor data to render Heat and Humidity maps Thermal map that isolates Hot and Cold Spot Map that visualizes CRAC Zones and determines CRAC Utilization Provide a sensor map that visualizes sensors of any type (temp, humidity, power etc) and displays current readings relative to configured thresholds. Hendrik F. Hamann / 34