epth Gage standard measuring tool of industry epth Micrometer SERIES 329, 129 Interchangeable Rod Type This type uses interchangeable rods to enable wide-range measurement. Order Nos. 329-250-30, 329-251-30, 329-350-30, and 329-351-30 allow integration into statistical process control and measurement systems. Measuring rod diameter: ømm Measuring rod lock. Ratchet stop provides constant measuring force. Technical ata ccuracy: ±3μm/±.00015 for micrometer head (Excluding quantizing error) Flatness of reference face: 1.3μm (.00005 ) for 63.5mm (2.5 ) length base, 2μm (.00008 ) for 101.6mm ( ) length base Flatness of measuring rod face: 0.3μm Parallelism between reference face and measuring rod face: (+R/50)μm, R = Max. measuring length (mm) Fraction rounded up ±(2+R/75)μm for interchangeable rod, R = Max. range (mm) Fraction rounded up Battery: SR (1 pc), 938882, for initial operational checks (standard accessory) Battery life*: pprox. 2. years under normal use * igital models Scale type: Electromagnetic induction absolute encoder 129-110 329-250-30 Order No. Range Resolution No. of rods igimatic (C) 329-250-30 0-150mm 6 0.001mm 101.6 x 16mm 329-251-30 0-300mm 12 Order No. Range Graduation No. of rods nalog 129-15 0-25mm 129-155 101.6 x 16mm 1 129-109 0-50mm 129-113 101.6 x 16mm 2 129-110 0-75mm 3 129-11 101.6 x 16mm 0.01mm 129-111 0 - mm 129-115 101.6 x 16mm 129-112 0-150mm 129-116 101.6 x 16mm 6 129-152 0-300mm 129-153 101.6 x 16mm 12 Interchangeable rod (Optional ccessories) (Check and adjust the origin point before measurement) / Order No. Range Resolution No. of rods igimatic (C) 329-350-30 0-6.00005"/0.001mm 6 x.63 329-351-30 0-12.0001"/0.001mm 12 Order No. Range Graduation No. of rods nalog 129-129 0-2 x.63 2 129-126 2.5 x.63 0-3 129-130 x.63 3 129-127 2.5 x.63 0-129-131.001" x.63 129-128 2.5 x.63 0-6 129-132 x.63 6 129-19 2.5 x.63 0-12 129-150 x.63 12 * For the function of igimatic models 329-250-30, 329-251-30, 329-350-30, and 329-351-30, refer to page -62. These models are not waterproof. Optional accessories for 329-250-30, 329-251-30, 329-350-30, and 329-351-30. For details, refer to page -21. Connection cable for 329-250-30, 329-251-30, 329-350-30, and 329-351-30 05CZ662: SPC cable with data button (1m) 05CZ663: SPC cable with data button (2m) USB Input Tool irect 06V380B: SPC cable for USB-ITN-B (2m) Connection cables for U-WVE-T 02Z790B: SPC cable for U-WVE with data button (160mm) 02ZE10B: SPC cable for footswitch Range 0-25mm 25-50mm 50-75mm 75 - mm - 125mm 125-150mm 150-5mm 5-200mm 200-225mm 225-250mm 250-275mm 275-300mm nalog models Order No. 983501 983503 983505 983507 983509 983511 983525 983527 983529 983531 983533 983535 10mm 129mm 15mm 9mm 20mm 229mm 25mm 279mm 30mm 329mm 35mm 379mm Order No. 983505 983507 983509 983511 983525 983527 983529 983531 983533 983535 9881 9882 igimatic models 15mm 9mm 20mm 229mm 25mm 279mm 30mm 329mm 35mm 379mm 0mm 29mm Range 0-1 1-2 2-3 3 - - 5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 Order No. 983502 98350 983506 983508 983510 983512 983526 983528 983530 983532 98353 983536 nalog models 10.3mm 129.7mm 155.1mm 180.5mm 205.9mm 231.3mm 256.7mm 282.1mm 307.5mm 332.9mm 358.3mm 383.7mm Order No. 983506 983508 983510 983512 983526 983528 983530 983532 98353 983536 9883 988 igimatic models 155.1mm 180.5mm 205.9mm 231.3mm 256.7mm 282.1mm 307.5mm 332.9mm 358.3mm 383.7mm 09.1mm 3.5mm -61
IMENSIONS Functions of 329-250-30, 329-251-30, 329-350-30, and 329-351-30 ORIGIN set: Resets the BS (absolute) origin at (BS measurement system) the current position. 16 ZERO set: (INC measurement ) The display is set to zero at the current position for incremental (comparative) mode measurements. bsolute system measurement mode can easily be restored when required. 101.6 ø Range 18 53 80.8 Preset: Enters a specified value into the display at the current position. ø18.3 Hold: The displayed value is temporarily held at the current value so that the instrument can be moved before the display is read. Useful for making measurements in difficult-to-access. 329-250-30, 329-251-30 Measurement data output: Equipped with a igimatic data output port to incorporate instrument into an SPC or networked measurement system. uto-power ON/OFF: If the instrument is not used for approximately 20 minutes, the display turns off while keeping the current origin of the BS measurement system. The display is restored when the spindle is rotated. Error alarm: If overflow of the display or a calculation error occurs, the measurement function stops and a message is displayed. Measurement will not be continued so as to avoid an erroneous display value. Warning light indicates low battery. 101.6 (63.5) 16 Range 18 ø 8.8 ø18.3 129-109, 129-113 ( ): 129-109 Function lock: PRESET (origin set) and ZERO (zero set) buttons can be locked in order to prevent them being changed unintentionally. -62
epth Gage standard measuring tool of industry epth Micrometer SERIES 128 Measuring rod diameter: ømm Measuring rod lock is attached. *Measuring rod is attached on the rear side of the micrometer. Carbide-tipped measuring rod model is available. Ratchet stop provides constant measuring force. 128-102 128-101 Technical ata ccuracy: ±3μm (±.00015 ) Flatness of reference face: 1.3μm (.00005 ) for 63.5mm (2.5 ) length base, 2μm (.00008 ) for 101.6mm ( ) length base Flatness of measuring spindle face: 0.3μm Order No. Range Graduation 128-101 128-103* 1 0-25mm 0.01mm 128-102 101.6 x 16mm 128-10* 1 *1 with carbide-tipped measuring rod Order No. Range Graduation 128-105 2.5 x.63 0-1.001" 128-106 x.63 epth Micro Checker SERIES 515 The epth Micro Checker is designed to check and help set the range-end points of a depth micrometer. n inspection certificate is supplied as standard. Refer to page X for details. 515-5 515-571 Order No. Range Block pitch accuracy nvil block accuracy 515-5 0-150mm 515-571 0-300mm ±(1+/150)µm, = ength to check (mm) ±0.5µm Order No. Range Block pitch accuracy nvil block accuracy 515-575 0-6 ±(0+/0.15) μinch, = ength to check (inch) 0µinch IMENSIONS 25mm anvil block provides the reference surface for the depth micrometer rod 515-571 200 5 150 125 75 50 25 515-5 9 35 300 275 250 225 150 125 75 50 25 9 16 180 72 92 92-63
BSOUTE igimatic epth Gage SERIES 571 Optional accessories for IP67 coolant proof models For details, refer to page -39. Connecting cables 05CZ62: SPC cable with data button (1m) 05CZ625: SPC cable with data button (2m) USB Input Tool irect 06CV380: SPC cable for USB-ITN-B (2m) Connecting cables for U-WVE-T 02Z790: SPC cable for U-WVE with data button (160mm) 02ZE10: SPC cable for footswitch Optional accessories for other than IP67 coolant proof models For details, refer to page -39. 95913: ata hold unit Connecting cables for IT/P/MUX 95919: SPC cable with data button (1m) 959150: SPC cable with data button (2m) USB Input Tool irect 06V380C: SPC cable for USB-ITN-C (2m) Connecting cables for U-WVE-T 02Z790C: SPC cable for U-WVE with data button (160mm) 02ZE10C: SPC cable for footswitch Coolant proof models achieve IP67 protection level. Enables stable depth measurement with a resolution of 0.01mm. BSOUTE igital Caliper (Refer to page -8 for BSOUTE function.) Sliding operation of models with the measuring ranges 150mm (6"), 200mm (8") and 300mm (12") is smooth and comfortable. Battery: SR (1 pc), 938882. For initial operational checks (standard accessory) Optional longer extension bases are available. (Except for models with measuring ranges of 600, 750, 0mm) 571-251-10 571-201-30 Order No. Range Resolution ccuracy* Repeatability (W x T) Battery life 571-201-30 0-150mm ±0.02mm 5years 571-202-30 0-200mm 571-203-20 0-300mm ±0.03mm x 6mm 3.5years 0.01mm 571-251-10** 0-150mm ±0.02mm 3years 571-252-10** 0-200mm 0.01mm 571-253-10** 0-300mm ±0.03mm x 6.3mm 1years 571-20-10 0-50mm ±0.05mm 571-205-10 0-600mm 0.01mm 250 x 10mm 3years 571-206-10 0-750mm ±0.06mm 571-207-10 0-0mm ±0.07mm * Excluding quantizing error ** IP67 Coolant Proof model IMENSIONS / Order No. Range ccuracy* Repeatability (W x T) Battery life 571-211-30 0-6 ±.001"/±0.02mm 571-212-30 0-8 ±.001"/±0.02mm 5years 571-213-10 0-12 ±.0015"/±0.03mm 3.5years 3.93 x.23 571-261-10** 0-6 ±.001"/±0.02mm 3years 571-262-10** 0-8 ±.001"/±0.02mm 0005"/ 571-263-10** 0-12 ±.0015"/±0.03mm 0.01mm 1years 571-21-10 0-18 ±.002"/±0.05mm 571-215-10 0-2 ±.002"/±0.05mm 571-216-10 0-30 ±.0025"/±0.06mm 9.8 x.39 3years 571-2-10 0-0 ±.0025"/±0.07mm * Excluding quantizing error ** IP67 Coolant Proof model 75.3 (73.7) 2.1 5 9.5 3.5 Thickness of main beam 7 86.7 2 36.5 (0.9) 16 571-201-30, 571-202-30, 571-203-20, 571-251-10, 571-252-10 *( ): No. 571-251-10, 571-252-10 20 8 12.5 250 65 65 (27.5) 25 13 -ø9 Range thickness 0-150mm 237 6 0-200mm 287 6 0-300mm 03 (0) 6 (6.3) 0-50mm 635 10 0-600mm 785 10 0-750mm 935 10 0-0mm 1200 10 ( ): Coolant Proof models 2.1 5 6 5 12 3.8 Thickness of main beam 7 2-.1 571-253-10 20 Thickness of main beam 65 27.5 571-20-10, 571-205-10, 571-206-10, 571-207-10-6
epth Gage standard measuring tool of industry Vernier epth Gage SERIES 527 Standard gage for depth measurement. Optional longer extension bases are available. (Except for models with measuring ranges of 600 and 0mm) 527-201 527-101 Fine adjustment Order No. Range Vernier reading ccuracy (W x T) Remarks 527-201 0-150mm ±0.05mm 527-202 0-200mm x 6.5mm 527-203 0-300mm 0.05mm ±0.08mm 527-20 0-600mm ±0.10mm 250 x 10mm 527-205 0-0mm ±0.15mm Order No. Range Vernier reading ccuracy (W x T) Remarks 527-101 0-150mm 527-102 0-200mm 0.02mm ±0.03mm x 6.5mm with fine adjsutment Order No. Range Vernier reading ccuracy (W x T) Remarks 527-111 0-6 527-112 0-8 ±.001 3.93 x.25 527-113 0-12.001 ±.0015 with fine adjustment 527-11 0-2 ±.002 9.8 x.39 527-115 0-0 ±.003 IMENSIONS 10 7 2- -ø9 527-201, 527-202, 527-203 (27.5) 16 11 Thickness of main beam Range 0-150mm 260 0-200mm 310 0-300mm 10 65 Range 0-600mm 800 0-0mm 1200 6 8 250 65 20 10 7 2 30 Thickness of main beam 527-101, 527-102 110 16 20 3.5 11 Thickness of main beam Range 0-150mm 260 0-200mm 310 65 (27.5) 527-20, 527-205 13 25-65
10 21 11 epth Gage SERIES 527, 571 Hook End Type The end of the main beam is hook-shaped to allow depth and thickness measurements of a projected portion or lip in a hole, in addition to standard depth measurement. Coolant proof models achieve IP67 protection level. Enables stable depth measurement with a resolution of 0.01mm. BSOUTE igital Caliper (Refer to page -8 for BSOUTE function.) 527-01 igital models display the compensation value by pressing the OFF switch to allow direct reading. Slider operation of the digital models is smooth and comfortable. llows integration into statistical process control and measurement systems for models with measurement data output connector. Refer to page -3. Battery: SR (1 pc), 938882. For initial operational checks (standard accessory) Battery life: pprox. 3 years under normal use (for digital models) Optional longer extension bases are available. pplications 1 = Reading on depth vernier 2 1 2 = Reading on hook vernier 3 = Reading on hook vernier Reading on depth vernier 3 Optional accessories for digital models For details, refer to page -21. Connection cables for coolant proof models 05CZ62: SPC cable with data button (1m) 05CZ625: SPC cable with data button (2m) USB Input Tool irect 06CV380: SPC cable for USB-ITN-B (2m) Connecting cables for U-WVE-T 02Z790: SPC cable for U-WVE with data button (160mm) 02ZE10: SPC cable for footswitch IMENSIONS 9.5 2- Thickness of main beam 527-01, -02, -03 571-25-10 Order No. Range: 1 (2 and 3) Resolution ccuracy* (W T) igimatic (C) 571-25-10** 10-160mm (0-150mm) 571-255-10** 10-210mm (0-200mm) nalog 527-01 10-150mm (0-150mm) 0.01mm ±0.03mm 6mm ±0.05mm 527-02 10-200mm (0-200mm) 0.05mm 527-03 10-300mm (0-300mm) ±0.08mm * Excluding quantizing error ** IP67 Coolant Proof model 6.5mm / Order No. Range: 1 (2 and 3) Resolution ccuracy* (W T) igimatic (C) 571-26-10. - 6. (0-6 ) 571-265-10. - 8. (0-8 ).0005 / 0.01mm ±0.0015"/ ±0.03mm 6mm * Excluding quantizing error Order No. Range: 1 (2 and 3) Vernier reading ccuracy (W T) nalog 527-11 10-150mm (0-150mm) ±0.03mm 527-12 10-200mm (0-200mm) 0.02mm 6.5mm 527-13 10-300mm (0-300mm) ±0.0mm 2-57.5 Range 0-150mm 260 0-200mm 310 0-300mm 10 26 10 10 ***10.16 (0. ) 0.9 16 571-25-10/571-255-10 *** 571-26-10/571-265-10 Range 0-150mm 27 0-200mm 297 3.5 7-66
epth Gage standard measuring tool of industry Extension s Optional accessory for epth Gage ttaches to the base (reference face) plate of a depth gage to extend its span. Refer to the illustrations at left for attachment details. Extension base is three times the length of the base for models of less than 300mm range. These extension bases cannot be attached to 0-600mm, 0-0mm, 0-2 and 0-0 range models. Example of attaching the extension base Extension base Order No. Size n 9003 180mm 2 900371 260mm 5 900372 320mm IMENSIONS 900372 Order No. Size n 900367 7 2 900368 10 5 900369 12 Extension base B B epth gage base Washer Mounting screw M n holes tapped M 0.7 R5 R5 7 Order No. B n T 9003 180 55 2 900371 260 35 60 5 8 900372 320 55 T: thickness epth Gage ttachment Optional ccessory for Calipers ttaching this depth gage attachment to the depth measurement face of the caliper makes depth measurement accurate and secure. Order No. Size pplicable measuring range of caliper 050083-10 75mm mm, 150mm, 200mm,, 6 and 8 05008-10 mm mm, 150mm, 200mm,, 6 and 8 050085-10 125mm 300mm and 12 05008-10 IMENSIONS C E Example of attaching the extension base B Size B C E T 75mm 75 25 26.5 18.5 12 mm 13 125mm 30 125 28.5 20 1 T: thickness -67
Note: *1 Caution should be exercised when exchanging a contact point of a epth Gage (ial/igimatic Indicator) If a different size contact point is mounted, displacement of the contact point from the base contact surface will be changed and as a result, measurement range may not be maintained. contact point cannot be mounted to a epth Gage, if its diameter is too large for the hole diameter of the base. Parallelism adjustment with the bottom face of the base is required when mounting a flat contact point such as the flat/needle or carbide-tipped contact point. *2 Caution on should be exercised when using an extension rod If the total length of the extension rod exceeds 110mm (.5") use the instrument in a vertical position (contact point downward). Use a master gage (such as Gauge blocks) to perform zero-setting when the extension rod is mounted. (Master gage is an optional accessory.) ial epth Gage SERIES 7 Optimal for hole, narrow groove and step measurement. 7211 721 7222 Example of use Extension rod Master gage (optional accessory) Contact point *3 Indicators Indicators for a epth Gage is used for the epth Gage. When the indicator is exchanged and extension rod is connected longer, the contact-point may incline significantly. Code No.53-00B / 53-02B for epth Gage has a measuring force less than 1.5N. Order No. Range Graduation ccuracy Stroke Measuring force 722 7231 W T Flatness Mounting position of a dial indicator Provided with a needle 7210 0-10mm 0mm point (No.13713) 7211 ±15µm 10mm 1.N 63.5mm Provided with a carbidetipped ball point 0-200mm 7212 101.6mm 16mm 1 (No.21J22) 7213 63.5mm Provided with a carbidetipped ball point 0-210mm ±30µm 30mm 2.5N 721 101.6mm (No.21J225) 7220 mm 2 Provided with a carbidetipped ball point 0-200mm 0.01mm 18mm 5µm 7221 150mm 3 (No.21J22) 10mm Provided with a needle 7222 mm 0-10mm ±15µm 1.N point (No.13713) 7223 ø25mm Provided with a carbidetipped ball point 722 ø0mm 1 (No.21J22: mm) 7231 0-200mm 5mm 63.5mm 16mm (No.21J226: 22mm) Order No. Range Graduation ccuracy Stroke Measuring force 72S 7218S 7237T 7238T 0-8.001 ±.002 1 2.5N.2 1.N W T Flatness 63.5mm 101.6mm Mounting position of a dial indicator 63.5mm 16mm.0002" 1 101.6mm 7220 and 7221 allow the mounting position of a dial indicator to be varied. Contact point* 1 Extension rod* 2 Indicator* 3 (dial indicator) 5 pcs. (10, 20, 30, 30, mm) 3 pcs. (30, 60, 90mm) 5 pcs. (10, 20, 30, 30, mm) 5 pcs. (10, 20, 30, 30, mm) 2902SB for epth Gage 2952SB for epth Gage 2902SB for epth Gage 1162T for epth Gage (Back plunger type) Contact point* 1 Extension rod* 2 Indicator* 3 (dial indicator) Carbide ball point (No.21JZ22) Provided with a carbidetipped ball point (No.21JZ22:.8mm) (No.21JZ23: 22.9mm) 3 pcs. (1, 2, ) pcs. (.5, 1, 2, ) 290SB for epth Gage 1168T for epth Gage (Back plunger type) -68
epth Gage standard measuring tool of industry IMENSIONS 7 7 7 7 (10) (11) 35.5 12 ø15. 7210 SR 0.2 11 (10) 65 35.5 SR 0.2 hole diameter hole diameter ø3 hole diameter hole diameter ø6 ø0 7222 (11) (10) 35.5 8 W SR1.5 7223 W=ø25mm 722 W=ø0mm () (10) (35) (11) W SR 1.5 7211 W=63.5mm 7212 W=101.6mm ø0 7 7 7 (10) 7213, 721: (30) 72S, 7218S: (26) (35) (11) 1 (.8) hole diameter ø6 W SR1.5 7213, 72S W=63.5mm 721, 7218S W=101.6mm () (10) (35.7) (18) ø6.5 hole diameter ø11 25 7220 SR 1.5 50 (10) () (35.7) (18) 25 25 75 150 hole diameter ø11 7221 7231, 7237T, 7238T (No.-8 UNF) M2.5x0.5 Part No. 21J226 (7231) Part No. 21J23 (7237T, 7238T) (interchangeable point) is provided as standard. Order No. B C 7231 (5) 22 7237T, 7238T (5.).8 22.9 BSOUTE igimatic epth Gage SERIES 57 Easy-to-read dial effectively prevents misreading. llows integration into statistical process control and measurement systems for models with measurement data output connector. Refer to page -3. IMENSIONS 8 ø6.5 SR 1.5 6.5 (35) (11) hole diameter ø6 SR 1.5 B 63.5 SR 1.5 C 11 57 9 65 35.5 8 (105) 10 5 SR 0.2 (67) 57-211 Order No. Range Graduation Stroke ccuracy* Measuring Contact point* force 1 Extension rod* 2 Indicator* W T flatness 3 57-211 63.5mm 0.01mm ±20µm 5μm Provided with a 53-00B* 57-212 101.6mm 3 carbide-tipped ball 5 pcs. 0-200mm 12.7mm 1.5N 16mm 57-251 63.5mm point (10, 20, 30, 30, mm) 0.001mm ±5µm 2μm (No.21J22) 53-390B 57-252 101.6mm / Order No. Range Graduation Stroke ccuracy* Measuring force W T flatness Coutact point* 1 Extension rod* 2 Indicator* 3 57-2S 2.5.0005"/0.01mm ±.001.0002 Provided with a 53-02B* 57-218S 3 carbide-tipped ball pcs. 0-8.5 1.5N.63 57-257S 2.5 point (.5", 1", 2", ").00005"/0.001mm ±.0002.00008 (No.21JZ22) 53-392B 57-258S *1 to *3: Refer to page -68. *: Excluding quantizing error. (12) (35) (11) SR1.5 hole diameter ø6-69
-