AVTRON MODEL K899 PERFORMANCE VIEW TM - ADDvantage Hardware Manual

Similar documents
1 Getting and Extracting the Upgrader

1 Getting and Extracting the Upgrader

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel

Westinghouse Nuclear Automation. Ovation -based Rod Control Logic Cabinet

Gemini Intercom Quick Start Guide

Firmware Upgrade Wizard v A Technical Guide

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015

Avigilon Control Center Virtual Matrix User Guide. Version 6.8

1 Getting and Extracting the Upgrader

DIVAR IP 3000 Field Installation Guide

Product Release Notes

Customized RTU for Local and Remote Supervision

Avigilon Control Center Server User Guide. Version 6.4

VMware EVO:RAIL Customer Release Notes

Admin Report Kit for Exchange Server

This Datasheet for the IC697CHS770. Redundant Rack (Dual) Rear Mount.

SMART Room System for Microsoft Lync. Software configuration guide

Wave IP 4.5. CRMLink Desktop User Guide

CaseWare Working Papers. Data Store user guide

ES93x INCA Add-On V1.4.0

Model 86A00-2 Home Theater Extender 2 (HTX2)

Avigilon Control Center Server User Guide. Version 6.8

Customers should provide all necessary operating supplies upon request of the engineer.

DELL PowerVault MD3200/MD3220 Series of Storage Arrays. A Dell Transition Guide Version 1.0

HP Server Virtualization Solution Planning & Design

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide

Milestone Solution Partner IT Infrastructure Components Certification Summary

HPE BladeSystem c3000 Tower Enclosure Quick Setup Instructions

IT Essentials (ITE v6.0) Pretest Exam Answers 100% 2016

Customers should provide all necessary operating supplies upon request of the engineer.

System Requirements for SurveyTracker Plus 6.0

Milestone XProtect. NVR Installer s Guide

SafeDispatch SDR Gateway for MOTOROLA TETRA

Launching Xacta 360 Marketplace AMI Guide June 2017

Dell EqualLogic PS Series Arrays: Expanding Windows Basic Disk Partitions

Connect+/SendPro P Series Networking Technical Specification

User Manual 3-Channel Pressure Datalogger Model SD750

I. Introduction: About Firmware Files, Naming, Versions, and Formats

Application Notes for Stratus ftserver 6310 with VMWare and Avaya Aura Contact Center Release 6.2 Issue 1.0

RACK-360G 4U Rackmount Chassis

Announcing Veco AuditMate from Eurolink Technology Ltd

Enterprise Installation

2. When logging is used, which severity level indicates that a device is unusable?

USER MANUAL. RoomWizard Administrative Console

CSC IT practix Recommendations

GE Multilin F650 Feeder Protection Relay and Bay Controller Specifications

Application Note. Digi Connect Wi-SP Troubleshooting Guide. Digi Technical Support 10 May 2016

Dear Milestone Customer,

3 Channel Pressure Datalogger. Model SD750 USER GUIDE

Product Release Notes

AFX CABINET SYSTEMS. AFX Series. 18 kva/kw to 150 kva/kw. DC, Hz Vac L-N / Vac L-L / 0 - ± 425 Vdc Bipolar

Service Level Agreement

User Guide. ACE Data Source. OnCommand Workflow Automation (WFA) Abstract PROFESSIONAL SERVICES

CCNA 1 Chapter v5.1 Answers 100%

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers

ADS ECHO Qstart Quick Reference Guide. 340 The Bridge Street, Suite 204 Huntsville, Alabama (256)

TPP: Date: October, 2012 Product: ShoreTel PathSolutions System version: ShoreTel 13.x

ABELDent Platform Setup Conventions

Document Revision CSSIR 03/07

Infinity RGB & Grayscale SERIES

PCI Multiple I/O Host Adapter 1. Introduction

Customer Information. Agilent 2100 Bioanalyzer System Startup Service G2949CA - Checklist

HPE AppPulse Mobile. Software Version: 2.1. IT Operations Management Integration Guide

SolarEdge. Communication Options. Version 1.1

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to:

September 24, Release Notes

multiflex cooling controllers

EBC-2102-R10 EBC-2102W-R10 Chassis for EPIC NANO Series

Element Creator for Enterprise Architect

HW4 Software Version 3.4.1

CLOUD & DATACENTER MONITORING WITH SYSTEM CENTER OPERATIONS MANAGER. Course 10964B; Duration: 5 Days; Instructor-led

Please contact technical support if you have questions about the directory that your organization uses for user management.

Max 8/16 and T1/E1 Gateway, Version FAQs

ADSS Server Evaluation Quick Guide

multiport Floppy Drive User s Manual

Networks: Communicating and Sharing Resources. Chapter 7: Networks: Communicating and Sharing Resources

Silent Messenger MegaTech Control Console

Service Level Agreement

Intro. to Computer Repair & Advanced Computer Repair

I. Introduction: About Firmware Files, Naming, Versions, and Formats

FollowMe. FollowMe. Q-Server Quick Integration Guide. Revision: 5.4 Date: 11 th June Page 1 of 26

EView/400i Management Pack for Systems Center Operations Manager (SCOM)

ABELMed Platform Setup Conventions

DELL EMC VxRAIL vcenter SERVER PLANNING GUIDE

Welcome to Remote Access Services (RAS) Virtual Desktop vs Extended Network. General

Dolby Conference Phone Support Frequently Asked Questions

Frequently Asked Questions

Setting up the ncipher nshield HSM for use with Kerberized Certificate Authority

Relion 650 General specifications

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems

HPE LoadRunner Best Practices Series. LoadRunner Upgrade Best Practices

Little Green Button (LGB)

CMC Blade BIOS Profile Cloning

HP ExpertOne. HP2-T21: Administering HP Server Solutions. Table of Contents

Statement of Work (SOW) IT activities associated with the Acne Sales Office Relocation Project

Apply power, the appliance may be powered by connecting:

INSTALLING CCRQINVOICE

RACK-3000G 4U Rackmount Chassis

Model WM100. Product Manual

Customers should provide all necessary operating supplies upon request of the engineer.

Transcription:

AVTRON MODEL K899 PERFORMANCE VIEW TM - ADDvantage Hardware Manual 2008 Avtrn Industrial Autmatin, Inc. September 2, 2003 Cleveland, Ohi Rev. Aug. 5, 2008

AVTRON MODEL K899 PERFORMANCE VIEW TM ADDvantage Hardware Manual TABLE OF CONTENTS Sectin Page I INTRODUCTION... 1-1 1.1 Overview.. 1-1 II SYSTEM DESCRIPTION... 2-1 2.1 Cllectr/Server... 2-1 2.1.1 PC.. 2-1 2.1.2 UPS System.. 2-1 2.2 Viewer.. 2-2 2.2.1 PC.. 2-2 2.2.2 Printer 2-3 2.2.3 Additinal Viewing Statins. 2-3 2.2.3.1 Desktp Statin... 2-3 2.2.3.2 Rack Munt Statin. 2-3 2.2.3.3 NEMA/Operatr Statin. 2-3 2.3 Ethernet I/O Subsystem... 2-4 III PREPARATION FOR USE. 3-1 3.1 Envirnmental/Pwer Requirements 3-1 3.1.1 Rack Munt/Desktp Equipment.. 3-1 3.1.2 NEMA Operatr s Statin 3-1 3.1.3 Ethernet I/O System.. 3-2 IV INSTALLATION.... 4-1 4.1 Rack Munt.. 4-1 4.2 Desktp.... 4-2 4.3 NEMA Operatr s Statin... 4-2 V TROUBLESHOOTING.. 5-1 VI SUPPORTED THIRD PARTY PROTOCOLS.. 6-1 PF/kv i

AVTRON MODEL K899 PERFORMANCE VIEW TM ADDvantage Hardware Manual SECTION I INTRODUCTION 1.1 OVERVIEW The Avtrn Mdel K899 Perfrmance View TM Graphic Trending and Event Histry Recrder is a sftware cntrlled device which prvides cmplete mnitring and trubleshting in supprt f prcesses such as machine cntrl systems, PLCs, and drive systems, including the Avtrn ADDvantage-32 Digital Drive. Diagnstic capabilities prvide early ntificatin and priritizatin f system irregularities, allwing fr the applicatin f preventive maintenance, rapid trubleshting, and reduced system dwntime. System data is acquired and cmmunicated ver an Ethernet netwrk, allwing fr real-time data display, r recall (histrical) display f stred data. *********************************************************** C A U T I O N D NOT attempt t replace the perating system. Cntact Avtrn's Service Department at 216-642-1230, Ext. 1255. *********************************************************** C A U T I O N Keep all manuals and sftware fr all cmpnents f this system in a safe lcatin. Avtrn is nt respnsible fr dcumentatin/sftware f third party cmpnents f this system. *********************************************************** Perfrmance View is a trademark f Avtrn Industrial Autmatin, Inc. Mdbus is a registered trademark f Mdicn, Inc. 1-1

Intrductin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual *********************************************************** W A R N I N G The perating sftware installed in the Avtrn Perfrmance View TM is critical t the peratin f the system. Installatin r peratin f any ther sftware prgrams, especially games r screen savers, is prhibited and vids any and all warranties. Installatin r peratin f ther sftware prgrams may interfere with the installed sftware, and damage t the cmpnents r peratin utside peratinal/safety rated limits may ccur, resulting in injury r death t persnnel, and/r damage t attached equipment. *********************************************************** W A R N I N G Cnnectin f external netwrk devices t the system is strictly prhibited withut the cnsent f Avtrn Industrial Autmatin, Inc. Ding s will vid any and all warranties. Lss f netwrk integrity/privacy may result. Cnsult Avtrn fr prper design techniques that wuld nt jepardize the netwrk architecture integrity. *********************************************************** W A R N I N G This system is a realtime data cllectin device. D nt attempt t change the system clck r Time zne while the cllectin sftware is running. Clse the Perfrmance View TM viewer first; then shut dwn the Cllectr using the Stp_Cllectr icn. It is nw safe t change the time. Rebt the system when dne. *********************************************************** W A R N I N G If using the ptinal NEMA Operatr s Statin be sure t munt the enclsure as specified befre use. *********************************************************** 1-2

System Descriptin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual SECTION II SYSTEM DESCRIPTION 2.1 COLLECTOR/SERVER Data acquisitin is managed by the Perfrmance View TM Cllectr/Server. The primary respnsibility f the Cllectr/Server statin is t cllect and stre data frm the cnnected devices and prvide the data t the viewer statins. 2.1.1 PC The Cllectr/Server PC cnfiguratin typically includes tw CPUs, 1 GB RAM, six high-speed disk drives (10K RPM) in a RAID cnfiguratin, a flppy disk drive, readable CD ROM, and scanners fr data cllectin. Tw hard-drives are used t stre the system perating sftware and event cllectin set-up data. A special Linux perating system prvides real-time enhancement. Fur (r mre) hard drives are used t stre real-time data and event histry. The fllwing minimum requirements must be met: (Qty. 2) 2.0 GHz CPU, 400 MHz FSB, 512 L2 Cache 1GB DDR Ram (Qty. 2) 18GB, 10,000 RPM SCSI hard drive (Qty. 4) 36GB, 10,000 RPM SCSI hard drive Readable CD ROM drive 3.25 flppy disk drive 56 KB Internal Phne Mdem 10/100T Netwrk Interface Card (Qty. 5) PCI-X expansin slts 10/100/1000T Embedded Netwrk Interface Card 19 Rack munt frm factr, 5U height, with rails fr server rack (fr rack munt cnfiguratin nly) 2.1.2 UPS SYSTEM The Uninterruptible Pwer Supply (UPS) is a device that sits between a pwer supply (e.g. a wall utlet) and a device (e.g. a cmputer) t prevent undesired characteristics f the pwer supply (utages, sags, surges, bad harmnics, etc.) frm the supply frm adversely affecting the perfrmance f the device. The UPS system used fr this system can be rack muntable r desktp based n cnfiguratin f system, have 2000VA/1600W minimum utput capacity, and supprt serial cnnectin t the hst cmputer. A 20 Amp, 110 VAC electrical utlet is required fr the UPS (Uninterruptible Pwer Supply) system. 2-1

System Descriptin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual The UPS system is als used t intelligently shut dwn the Cllectr/Server and Viewer in such a way as nt t crrupt any f the database files. DO NOT attempt t perate the Cllectr/Server r Viewer withut a prperly cnfigured UPS. 2.2 VIEWER The user interface t the Perfrmance View TM Cllectr/Server is thrugh the Perfrmance View TM Viewer Statin. 2.2.1 PC The Viewer PC incrprates a Windws 2000 Prfessinal Operating System and must cntain at minimum the fllwing hardware: 2.0 GHz CPU, 400 MHz FSB, 512 L2 Cache 256 MB DDR Ram 18GB, 10000 RPM IDE hard drive 3.25 flppy disk drive 56 KB Internal Phne Mdem (Qty. 2) PCI-X expansin slts (Qty. 2) 10/100/1000T Embedded Netwrk Interface Card 19 Clr CRT Mnitr Windws Keybard Standard Muse 19 rack munt frm factr, 2U height, with rails fr server rack 2-2

System Descriptin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual 2.2.2 PRINTER HP Inkjet 5850 desktp clr printer, r equivalent, used t print real-time r histrical representatin f data and graphical trending screens. 2.2.3 ADDITIONAL VIEWING STATIONS Multiple viewing statins may be added t the netwrk. Each viewing statin must be cmpsed f a PC, mnitr, keybard and muse. 2.2.3.1 Desktp Statin An additinal desktp viewing statin may be added t the Perfrmance View TM ADDvantage system as an ptin. The additinal viewing statin requires an additinal desktp PC (the same minimum requirements listed in sectin 2.2.1 abve), 19 mnitr, keybard, and muse. 2.2.3.2 Rack Munt Statin An additinal rack munt viewing statin may be added t the Perfrmance View TM ADDvantage system as an ptin. The additinal viewing statin requires an additinal rack munt PC (the same minimum requirements listed in sectin 2.2.1 abve), 19 mnitr, keybard, and muse. 2.2.3.3 NEMA Operatr Statin The add-n NEMA peratr statin can extend a viewing statin ut t the factry flr. This statin utilizes a NEMA 4x, 18.1, TFT, flat panel mnitr, NEMA 4x panel munt keybard with hula pint device, and chice f NEMA 12 r 4x enclsure. The viewing statin can extend ut n the factry flr frm the viewing statin PC (lcated within a cntrl rm) up t 500 ft. r 1,000 ft. using a KVM extender. The NEMA enclsure can be manufactured fr wall r pedestal munted depending n applicatin. 2-3

System Descriptin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual 2.3 ETHERNET I/O SUBSYSTEM An ptinal Ethernet remte I/O system may als be added t the Perfrmance View TM System. This interface can be made using a Netwrk Interface Unit (NIU), supprting EGD prtcl nly, which may supprt up t eight f the fllwing available I/O mdules per NIU: 16 pints, 120VAC discrete input islated 16 pints, 120VAC discrete (2 grups f 8 pints) 16 pints, 24VDC discrete (2 grups f 8 pints) 8 channel 16-bit analg input (vltage/current) 8 channel 12-bit analg input (vltage/current) 8 channel 15-bit analg differential vltage input 8 channel 15-bit analg differential current input 15 channel, 15-bit analg vltage input 15 channel, 15-bit analg current input All I/O mdules are DIN rail muntable including the NIU interface mdule. Additinal infrmatin n the ptinal Ethernet I/O system may be fund in the Avtrn Supprted GE Fanuc Autmatin Prgrammable Cntrl Prducts: VersaMax Mdules, Pwer Supplies, and Carriers supplement t this manual. 2-4

Preparatin fr Use Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual SECTION III PREPARATION FOR USE 3.1 ENVIRONMENTAL/POWER REQUIREMENTS Befre using any f the cmpnents fr this system, ensure the fllwing envirnmental and pwer requirements are within the recmmended ranges. 3.1.1 RACK MOUNT/DESKTOP EQUIPMENT The listed envirnmental cnditins must be kept within the fllwing limits fr all cmpnents with exceptin t the ptinal NEMA Operatr s Statin and the ptinal Ethernet I/O system. Operating Temperature: 10º C t 35º C (50º F t 95º F) Strage Temperature: -40º C t 65º C (-40º F t 149º F) Operating Relative Humidity: 8% t 80% nn-cndensing Strage Relative Humidity: 5% t 95% nn-cndensing Operating Vibratin: 0.25G at 3Hz t 200Hz fr 15 minutes Strage Vibratin: 0.5G at 3Hz t 200Hz fr 15 minutes Operating Shck: 6 shck pulses f 50G fr up t 2ms Strage Shck: 6 shck pulses f 92G fr up t 2ms Operating Altitude: -16m t 3,048m (-50 ft. t 10,000 ft.) Strage Altitude: -16m t 10,600m (-50 ft. t 35,000 ft.) Operating Air Quality: Dust-free, ffice-grade air required fr ventilatin 3.1.2 NEMA OPERATOR S STATION The envirnmental cnditins f the NEMA enclsure must be within the fllwing range: Operating Temperature: 0º C t 40º C (32º F t 104º F) 0º C t 55º C (32º F t 131º F) with ptinal cling unit installed n enclsure Strage Temperature: -20º C t 50º C (-4º F t 122º F) Operating Relative Humidity: 20% t 80% nn-cndensing Strage Relative Humidity: 20% t 80% nn-cndensing Operating Vibratin: 1.0G at 5Hz t 2000Hz Strage Vibratin: 2.5G at 5Hz t 2000Hz Operating Shck: 15G fr up t 11ms Strage Shck: 30G fr up t 11ms 3-1

Preparatin fr Use Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual Operating Altitude: 0m t 3,048m (0 ft. t 10,000 ft.) Strage Altitude: 0m t 12,192m (0 ft. t 40,000 ft.) The pwer requirement must be within the fllwing range: AC Pwer: 100 VAC t 240 VAC, 1.0 A, 50/60 Hz 3.1.3 ETHERNET I/O SYSTEM Refer t the Avtrn Supprted GE Fanuc Autmatin Prgrammable Cntrl Prducts VersaMax Mdules, Pwer Supplies, and Carriers supplement t this manual fr envirnmental and pwer specificatins. 3-2

Installatin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual SECTION IV INSTALLATION Installatin f the Perfrmance View TM ADDvantage System shuld fllw the typical layut f the example diagram shwn belw: Typical Perfrmance View System Layut Refer t the Avtrn Mdel K899 Perfrmance View Graphic Trending and Event Histry Recrder User s Manual fr infrmatin n sftware installatin. 4.1 RACK MOUNT The hardware installatin f the Perfrmance View TM ADDvantage rack munt cnfiguratin can be perfrmed as shwn in the included drawings (refer t wiring drawings included in drawing packet fr details). 4-1

Installatin Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual 4.2 DESKTOP The hardware installatin f the Perfrmance View TM ADDvantage desktp cnfiguratin can be perfrmed as shwn in the included drawings (refer t wiring drawings included in drawing packet fr details). 4.3 NEMA OPERATOR S STATION T prvide a user interface t the Perfrmance View TM ADDvantage system n the factry flr the NEMA Operatr s Statin ptin may be used t take the place f the mnitr, keybard, and muse cmpnents f the desktp cnfiguratin. The installatin f the NEMA Operatr s Statin can be cmpleted as shwn in the included drawings (refer t wiring drawings included in drawing packet fr details). 4-2

Trubleshting Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual SECTION V TROUBLESHOOTING Fr questins r prblems, refer t the Frequently Asked Questins (FAQ) under the Perfrmance View link n the Avtrn website (www.avtrn.cm) r call Avtrn supprt. 5-1

Supprted Third Party Prtcls Avtrn Mdel K899 Perfrmance View - ADDvantage - Hardware Manual SECTION VI SUPPORTED THIRD PARTY PROTOCOLS The fllwing prtcls are supprted fr lgging data frm a custmer-supplied third party device nly: Mdbus TCP/IP Ethernet Mdbus TCP/IP prtcl utilizes the Ethernet RJ-45 netwrk interface prt n the Cllectr/Server PC. Ethernet Glbal Data (EGD) EGD prtcl utilizes the Ethernet RJ-45 netwrk interface prt n the Cllectr/Server PC. Ethernet/IP Explicit Messaging Ethernet IP prtcl utilizes the Ethernet RJ-45 netwrk interface prt n the Cllectr/Server PC. Rckwell Autmatin PLC-5 (CSP) Ethernet CSP prtcl utilizes the Ethernet RJ-45 netwrk interface prt n the Cllectr/Server PC. Rckwell Autmatin SLC/05 (CSP) Ethernet CSP prtcl utilizes the Ethernet RJ-45 netwrk interface prt n the Cllectr/Server PC. Cnsult Avtrn fr availability f any ther custm prtcls. 6-1