Data centre solutions - energy efficient by design

Similar documents
Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Repeatable IT Hub Rooms

Case Study Host Europe Group

Repeatable IT Hub Rooms

APC by Schneider Electric Elite Data Centre Partner

Engineering & Support Services

Case Study Leicester City Council

The PowerLogic range. Gain energy insight and control

Case Study The University of Warwick

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Industry leading low energy evaporative fresh air cooling.

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

1.0 Executive Summary. 2.0 Available Features & Benefits

Simple Electrical Utility Cost Allocation Solutions

Tel: AC Power for Business-Critical Continuity TM

Data Centre Solutions Expertly Engineered APC Management Software

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Planned Preventative Maintenance Schedule. Raised Access Floor PPM Schedule

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

The synergy of SCADA with energy control

The challenge is that BAS are often very complex with 1000s of data points to review. EMS Optimization Software

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Data Centre Optimisation Services

Energy Solutions for Buildings

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MODULAR CIRCUIT MONITORING SYSTEM

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Power Generation. Power Generation services deliver continuous and predictable power availability for 24/7 mission critical environments.

18 th National Award for Excellence in Energy Management. July 27, 2017

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MEASURE MONITOR UNDERSTAND

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Modular, scalable, high-efficiency power protection for data centers

EDX DC-3 environmental monitoring solution

Data Center Infrastructure Management (D.C.I.M.)

Integrated Energy Management System

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Engineering and Manufacturing Excellence in Data Centre Infrastructure

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

Excel Power Distribution

Modular, scalable, high-efficiency power protection for data centers

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

10G the Next Generation Structured Cabling. Technology Paper 002

MGE Galaxy /900 kva

ECOWISE EM100 THE MULTI-FUNCTIONAL DEVICE SERVER

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

PowerLogic Branch Circuit Power Meter Series. Harness industry-leading monitoring capabilities for maximum power reliability

Comprehensive Data Center Energy Management Solutions

DIRIS A. Multifunction measurement units for managing your electrical networks

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Power Management Solutions Maximise the reliability and efficiency of your power critical facility

ims - Modular DCIM Solution

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management

Total Modular Data Centre Solutions

Building Management Solutions. for Data Centers and Mission Critical Facilities

Thermal management. Thermal management

Data Centre In A Box

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Data Center Integrated solutions

Data Center Integrated solutions

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

Com X 210, Com X 510 Technical Datasheet

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Simple, fast data acquisition and transfer for big data analytics

Highly Efficient Power Protection for High Density Computing Applications

Table of Contents. PowerTag - Smallest Wireless Energy Sensor

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

Green Computing: Datacentres

Ecotel Free Cool 5-15kW

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Product Brochure Eaton 93PR UPS kw

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

PowerLogic TM Tenant Metering Solutions. Neel Sharma Schneider Electric 1

SMARTER BUILDING. Give your buildings a new dimension Scalable solutions for energy and asset management

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

Green Data Centers A Guideline

Nominee: Riello UPS with The Rosebery Group

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Transcription:

Data centre solutions - energy efficient by design scalable data centre energy management solution Creating an effective workspace environment

scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology Ltd Metering total energy is important, but it does not show how energy consumption is being used within a data centre facility. Without measurement it can be hard to understand why and where energy performance is poor and how to improve it. It is a recommendation of the Carbon Trust* that sub metering of high energy consumption infrastructure is implemented. EcoMeasure is a service which enables data centre managers to accurately measure the performance and energy consumption of any data centre facility. EcoMeasure can be deployed in new or retrofitted within existing environments. The system provides direct information on power and energy consumption and delivers accurate benchmarking of data centre energy efficiency. EcoMeasure will deliver a comprehensive range of metrics and readings including Power Usage Effectiveness** (PUE), Data Centre Infrastructure Efficiency** (DCiE), UPS efficiency, mechanical services; and critical equipment loads. The more granular the measurement the more effective EcoMeasure becomes. EcoMeasure provides equipment level metering for customer billing when combined with our metered epdu technology. Workspace Technology provides expert analysis and interpretation of energy data through our Managed EcoMeasure service. This service ensures peak performance is maintained throughout the life of the data centre. This is achieved by constant configuration adjustment which compensates for the inevitable on-going changes to the critical equipment profile. EcoMeasure empowers data centre managers to track energy costs and to validate savings when investments are made in either infrastructure or technology. * Carbon Trust is a UK Government body which works with business and the public sector to cut carbon emissions and capture the commercial potential of low-carbon technologies. ** Data Centre Infrastructure Efficiency / Power Usage Effectiveness are industry recognized standards for data centre room efficiency measurement introduced by the Green Grid. 2

EcoMeasure Deployment Benefits Assists in reducing the cost of energy consumption, minimising environmental and economic impacts associated with excessive energy use Green Grid Category 2 / 3 Compliant measurement of PUE within a data centre Room, PDU and rack level customer billing and power consumption verification where chargeback is required. Scalable configurations to suit individual data centre and server room topologies what ever the size and complexity of the power distribution Instant confirmation of Data Centre PUE efficiency ratings Accurate proof of any claimed energy efficiency deployments throughout the life of the facility Measurement of energy consumption, critical load trends, power quality and response time of emergency power plant Ensure utility bills are correct Opportunities to improve a server room or data centres operational efficiency Shows how a server room or data centre compares to other internal or competitive facilities. 3

EcoMeasure Efficiency Metrics EcoMeasure provides data centres with an impressive array of power and energy measurements. In addition to traditional measures, the solution will provide data centre managers with PUE and DCiE energy efficiency metrics. Power Usage Effectiveness (PUE) = Total Facility Power and its reciprocal, the DCiE is defined as: I.T Equipment Power Data Centre Infrastructure Efficiency (DCiE) = I.T Equipment Power I.T Equipment Power Total Facility Power This includes the load associated with all of the I.T equipment, such as compute, storage and network equipment, along with supplemental equipment such as KVM switches, monitors, and workstations/laptops used to monitor or control the data centre. Total Facility Power This includes everything that supports the I.T equipment load such as: Total I.T equipment power Power delivery components such as UPS, switch gear, generators, PDU s batteries, and distribution losses external to I.T equipment Cooling systems components such as chillers, computer room air conditioning units, direct expansion air handler (DX) units, pumps, and cooling towers Other misc. loads including lighting, BMS panels etc. 4

Why Does Data Centre Energy Efficiency Matter? Data centre managers may ask, Does it matter what the energy efficiency rating of my room is? Table 1 below demonstrates the answer to this question in financial terms. Table 2 shows the answer in terms of CO 2 emissions. Table 1 Comparison of energy running costs for typical data centre s with different efficiency ratings (10p per KW/hr). Critical Load Kw DCiE 25% PUE 4.0 DCiE 50% PUE 2.0 DCiE 66% PUE 1.5 DCiE 80% PUE 1.25 DCiE 100% PUE 1.0 10 35,040 17,520 13,140 10,950 8,760 20 70,080 35,040 26,280 21,900 17,520 25 87,600 43,800 32,850 27,375 21,900 50 175,200 87,600 65,700 54,750 43,800 100 350,400 175,200 131,400 109,500 87,600 150 525,600 262,800 197,100 164,250 131,400 200 700,800 350,400 262,800 219,000 175,200 300 1,051,200 525,600 394,200 328,500 262,800 500 1,752,000 876,000 657,000 547,500 438,000 750 2,628,000 1,314,000 985,500 821,250 657,000 1000 3,504,000 1,752,000 1,314,000 1,095,000 876,000 Rate per KwH 0.1 Table 2 Comparison of CO 2 with different efficiency ratings Critical Load Kw DCiE 25% PUE 4.0 CO Tonnes 2 DCiE 50% PUE 2.0 CO Tonnes 2 DCiE 66% PUE 1.5 CO Tonnes 2 DCiE 80% PUE 1.25 CO Tonnes 2 DCiE 100% PUE 1.0 CO Tonnes 2 10 2,102 1,051 788 657 526 20 4,205 2,102 1,577 1,314 1,051 25 5,256 2,628 1,971 1,643 1,314 50 10,512 5,256 3,942 3,285 2,628 100 21,024 10,512 7,884 6,570 5,256 150 31,536 15,768 11,826 9,855 7,884 200 42,048 21,024 15,768 13,140 10,512 300 63,072 31,536 23,652 19,710 15,768 500 105,120 52,560 39,420 32,850 26,280 750 157,680 78,840 59,130 49,275 39,420 1000 210,240 105,120 78,840 65,700 52,560 Kw to CO 2 Kw Conversion 0.006 5

Table 2 Comparison of CO 2 with different efficiency ratings Typical Datacenter Target Datacenter Chiller Plant 40% PUE = 2.5 CRAC Loads 50% PUE = 2.0 UPS/Transformer Loss Lighting IT Load The relationship between power and energy. Technology Platform The EcoMeasure solution is delivered through the deployment of equipment provided Schneider Electric, the industry leader in power metering and power management software products. PowerLogic* ION Enterprise software is a complete power management solution which comprehensively delivers the management functions of the EcoMeasure service. It is a scalable software platform with options to support different numbers of remote devices and clients. Additional data servers are also available depending on the application. Characteristics Compatible with all PowerLogic ION-series meters, PowerLogic PM800 series, PM750 and PM710, PM210 as well as MicroLogic A, P and H breaker control units Supports third-party meters, sensors and other equipment through Modbus protocol or OPC Connects to remote devices over internet, ethernet, wireless, modem, satellite, and serial connections Integrates metering of all utilities (e.g. electricity, gas, water, air) Customisable ION architecture Multi-site meter aggregation and trending, coordinated control functions, complex calculations and alarming Inter-operability with third-party systems, applications and services (e.g. BAS, DCS, ERP, web) through ODBC, OPC, XML, email, FTP, CSV, PQDIF (power quality) 6

Scalable architecture, Windows SQL Server 2005 database, ODBCcompliant, support for multiple distributed servers and clients Enterprise web portal access to system-wide display of real-time measurements, equipment status, event and historical logs, customizable graphics, trends, captured waveforms Preconfigured and custom reports, report wizard, scheduled distribution via email or web Trend graphing for any measured parameter, load aggregation Power quality analysis including compliance monitoring to international standards (IEC 61000-4-30, EN50160), wide-area event monitoring and tolerance curve plotting, waveform viewer, measurement of harmonics, K-factor, crest factor and symmetrical components Trigger on complex conditions, alarming, event logging Manual or coordinated setpoint-triggered control of loads, generators, and other equipment. 7

PowerLogic PM750* meter The PM750 digital meters, provide flexible metering deployment within custom panels, switchboards, switchgear, gensets, motor control centres and UPS systems as required to deploy a complete EcoMeasure client solution. The PM750 meter supports direct connection up to 480V AC and seamlessly integrates with the PowerLogic energy management system. The PowerLogic PM750 meter combines quality, versatility and functionality in a cost-effective, ultra compact unit. It can be easily retrofitted into an existing metering system, and is simple to use and configure with user-friendly software and a large, bright LCD display for easy readability, even in extreme lighting conditions and viewing angles. PM700 services metre front/rear view Complete with power, demand, energy, power factor and frequency measurements, the PM750 meter is available in a variety of configurations and has IEC 62053-21 Class-1 and IEC 62053022 Class 0.5S certification for basic sub-billing or cost allocation. The meter produces high accuracy measurements that can be used for bill verification, monitoring back-up power for critical systems and costeffective energy management solutions. In addition, the PM750 meter allows for monitoring down to tool level to help manage cost centers, identify opportunities for demand control and check energy consumption patterns. For greater control over the performance and overall health of a system, the PM750 meter comes equipped with remote monitoring and control capabilities, allowing it to diagnose and isolate impending problems before they lead to equipment malfunctions or downtime. It features 15 user-configurable alarms, covering the most prevalent over and under conditions in typical power systems. Combining any of the PM750 meters I/Os with these alarms allows for communication through its two-wire RS-485 port for remote monitoring and control. Characteristics: Requires only 50mm behind mounting surface Large back lit display with integrated bar charts Intuitive use Power and current demand, THD and min/max reading in basic version Energy class 1 as defined by IEC 61036 8

PowerLogic EGX100* Ethernet Gateway The EGX100 gateway serves as an Ethernet coupler for PowerLogic System devices and for other communicating devices that use RS485 Modbus protocol. The EGX100 gateway offers complete access to all measurements and status information from connected devices. Characteristics: 10/100Base-Tx ethernet port RS485 / RS232 serial port, optically isolated 2-wire and 4-wire compatibility Support for serial master to ModbusTCP/IP routing P30, DIN rail mounted enclosure Web Interface for configuration, diagnostic and maintenance Advanced security through ModbusTCP/IP filtering with configurable access levels (read-only or full access) Secure user interface including user's name & password log-in User interface in English, French, German, and Spanish Control power through PoE (Power over Ethernet) or 24 Vdc power source Rated for use in industrial environments (-25 to 70oC). * Registered Trademarks of Schneider Electric. 9

EcoMeasure Integration Services The deployment of EcoMeasure consists of sequenced activities to ensure that full and accurate measurement can be achieved for each server room or data centre environment. Step 1 - Electrical Services Audit The initial step will require site audit to establish potential measurement points to ensure as a minimum Total Facility Power and I.T Equipment Power readings are captured. In addition we will investigate the deployment of further meters which will help provide wide range of metrics for the facility. Total Facility Power is measured at the input power feeds to the data centre. This should represent the total power entering the data centre (for which the utility supplier will charge). The practical measurement point for I.T Equipment Power is the output of the UPS, UPS bypass switch, or critical distribution power boards which support the critical I.T equipment load. Ideally this is measured at the equipment power intake. Site sketches, photographs and initial recommendations will form the output of this step. Step 2 - EcoMeasure Design Following the initial EcoMeasure audit, Workspace Technology engineers will generate a configuration to deliver a range of practical readings and metrics which will include:- Total Facility Power and I.T Equipment Power as a minimum design target. The output of this step is a high level electrical schematic with identified measurement points, PowerLogic equipment schedule, wiring configuration and software configuration parameters. Step 3 - EcoMeasure Installation Measurement technology will be deployed within power distribution boards as specified during the audit phase. Works will be programmed to ensure minimum disruption to services with out of hours installations where power downs are required. Installation services include all metres, CT s, control cable, gateway connections, PoE and Ethernet connectivity. The result of this step is a fully installed and wired measurement and analysis solution. Step 4 - Configure and Commission EcoMeasure Software Workspace Technology consultants will configuration and software set up the PowerLogic* ION Enterprise software to deliver all agreed metrics and measurements. 10

Managed EcoMeasure TM Service The power consumption and associated energy efficiency within any data centre is in a constant state of flux. Typically the critical load will increase or decrease in response to user compute demands, ICT refresh and deployment of additional services. Very often Data Centre Managers are focused on performance and availability of core ICT services, with little opportunity or the means to manage optimum energy efficiency within their facilities, and as a consequence the data centre PUE will slowly drift from the peak design capability Workspace Technology s Managed EcoMeasure service provides ongoing analysis and interpretation of readings and metrics for data centre facilities. The Managed EcoMeasure service helps Data Centre Managers maintain peak PUE performance. Continued use of the Managed Service will ensure that performance levels are maintained throughout the life of the facility. Peak performance will be achieved through facility adjustments to compensate for the inevitable on-going changes to the IT critical load profile. Workspace Technology s EcoMeasure service will achieve tangible reductions in data centre carbon emissions, and reduced energy consumption. The Managed service pricing model consists of a one of set up costs with monthly, bi monthly or quarterly reporting charges as mutually agreed for the facility. Additional charges apply to system changes and modifications inline with recommendations. 11

Making the difference Connecting with our clients Workspace Technology s Data Centre Solutions division offer clients Data Centre, Server and Communications Room solutions and services which are Energy Efficient by Design. By engaging you and taking the time to understand the business and performance related issues Workspace Technology is able to effectively address the demands of your business. Workspace Technology welcomes this opportunity to connect with you as a valued customer. We would like to share our vision and expertise through a partnership approach. Our ability to deliver integrated, scalable, energy efficient solutions has made us the preferred choice for many public sector and commercial businesses today. is part of Workspace Technology s Ecodesign range of products and services. Operating throughout the UK, Workspace Technology offers clients an enthusiastic and refreshing approach, combined with teamwork that takes performance and service to new levels of excellence. The design and implementation EcoMeasure solutions forms part of Workspace Technology s overall strategy, providing clients with a complete turnkey approach to the design and build of data centre and server room solutions. Further details of Workspace Technology s products and services can be found at www.workspace-technology.com. Approved Endorser EU Code of Conduct on Data Centre Efficiency APC Elite Partner Data Centre Certified Workspace Technology s Commitment to help clients reduce their carbon footprint through the deployment of energy efficient technology and design. Creating an effective workspace environment Workspace Technology Limited Technology House, 5 Emmanuel Court, Reddicroft, Sutton Coldfield, West Midlands B72 1TJ. Tel : 0121 354 4894 Fax: 0121 354 6447 email : sales@workspace-technology.com www.workspace-technology.com