Product Specification. Senseair LP8. Miniature CO 2 sensor module for battery-powered applications

Similar documents
Product Specification. Sensor Module and OEM Platform

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

Product Specification. CO 2 Engine K30 STA. Sensor Module and OEM Platform

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

tsense (Disp) T RH RL

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

Modbus on tsense. Table of contents:

Datasheet: K-33 BLG Sensor

Modbus on CO 2 Engine and esense

MH-Z16 Intelligent Infrared Gas Module

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

Trueyes Inc. Carbon Dioxide (CO2) Module

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

MH-Z16 Intelligent Infrared Gas Module Manual

an ISO9001/14001 company

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6

The CO 2 Engine Infrared Gas Sensing For OEM Applications

The unit is designed for connecting to Direct Digital Control (DDC). The linear output functions are pre-programmed as CO 2

Intelligent Infrared CO 2 Gas Sensor. (Model: MH-711A) Manual. Version: 3.3. Valid from: May 1st, 2014

2.2 Main technical parameters. Detection range. 0~5%vol(0~100%vol optional) Warm-up time. SPAN <±500ppm Long-term drift

2 AA Cell to 3.3V USB On-The-Go Devices White LED Drivers Handheld Devices. The HM3200B is available in the 6-pin SOT23-6.

HX4002 HX1001. White LED Backlighting Li-Ion Battery Backup Supplies Local 3V to 5V Conversion Smart Card Readers PCMCIA Local 5V Supplies

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan

DS21T09 Plug and Play SCSI Terminator

AN2408 Application note

MH-Z14 Intelligent Infrared Gas Module User s Manual

Manual iaq-core Indoor Air Quality sensor module

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

DS WIRE INTERFACE 11 DECOUPLING CAP GND

Manual iaq-engine Indoor Air Quality sensor

Application Note. E2 Interface for EE871, EE892 and EE893

Triple Touch DIMMER for Low Power LEDs

TS04. 4-Channel Self Calibration Capacitive Touch Sensor SPECIFICATION V2.0

AL3159 Evaluation Module

DS1233A 3.3V EconoReset

User s Manual. Electrochemical Ozone Detection Module. (Model:ZE25-O3) Zhengzhou Winsen Electronics Technology Co., Ltd. Version: 1.

Datalogging IAQ Meter Instruction Manual

LCMM024: DRV8825 Stepper Motor Driver Carrier,

AIC1520. Ferrite Bead GND. *33µF, 16V Tantalum, or 100µF, 10V Electrolytic Bold line indicate high-current traces. USB High-Side Power Switch

MP6302 Energy Storage and Release Control IC

NSGV Series "90DM3" Carbon Dioxide Detector

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

Low Voltage, 10-Bit Digital Temperature Sensor in 8-Lead MSOP AD7314

Evaluation Board for the AD7790/AD /24-Bit, Low Power, Σ- ADC

MegaAVR-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER

BCT mA Buck/Boost Charge Pump LED Driver

MP6500 Stepper Motor Driver, Digital Current Control

DIO5151B 700mA/1A Buck/Boost Charge Pump LED Driver

DS2223/DS2224. EconoRAM FEATURES PACKAGE OUTLINE. PIN CONNECTIONS Pin 1 GND Ground Pin 2 DQ Data In/Out Pin 3 V CC Supply Pin 4 GND Ground

BT-22 Product Specification

A general-purpose industrial input/output

T67xx C0 2 Sensor Module Application Note

TSYS01-FAMILY Digital Temperature Sensors

OEM Digital NDIR CO 2

MAX14653/MAX14654/ MAX14655/MAX High-Current Overvoltage Protectors with Adjustable OVLO

STBC ma standalone linear Li-Ion battery charger with thermal regulation. Description. Features. Applications

Craft Port Tiny RS-232 Transceiver for Portable Applications ADM101E. Data Sheet FUNCTIONAL BLOCK DIAGRAM

DS21S07AE. SCSI Terminator

User s Manual. Electrochemical CH 2 O Detection Module. (Model:ZE08-CH 2 O) Zhengzhou Winsen Electronics Technology Co., Ltd. Version: 1.

UM3221E/UM3222E/UM3232E

TouchCore351-ML16IP. Capacitive Touch Sensor Controller

Page 1 of 11 Version 1.2 Release Date: PenMount PM2204 PCI Controller Board Data Sheet. Table of contents

WBI Series Mass flow sensors for gases

Carbon Dioxide Monitor/Controller With The USB Data Logger

SN8200 LI+ DUAL BATTERY CONTROLLER

High-Current/Overvoltage Protection Switch IC with Voltage Suppressor

Temperature and humidity module DHT11 Product Manual

NanoPower BPX. Datasheet High-capacity battery pack for nano-satellites

Modbus on K45 asense. Table of contents:

Expansion Module HZS 541-1S

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Product Specification

PCD DIGITAL Differential pressure probe

Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

ILI2511. ILI2511 Single Chip Capacitive Touch Sensor Controller. Specification ILI TECHNOLOGY CORP. Version: V1.4. Date: 2018/7/5

Auxiliary Board MP-Bus HZS 562

LGR-5325 Specifications

Two-wire. Jumper for 12V. J2 Enable Adjust D/A1. Super PLC Warning: Warranty Void if this label is damaged 62256LP-12 CMOS RAM 4.

Electro Optical Components, Inc.

UM3222E,UM3232E. High ESD-Protected, Low Power, 3.3V to 5.5V, True RS-232 Transceivers. General Description. Applications.

Grove - Multichannel Gas Sensor

ILI2312. ILI2312 Single Chip Capacitive Touch Sensor Controller. Specification ILI TECHNOLOGY CORP. Version: V1.03.

High Current Power Switch

ISO K line serial link interface

V PP IN V CC3 IN V CC5 IN EN0 EN1 MIC2561 V CC5_EN V CC3_EN

HM9708 HM9708. Battery-Powered Equipment Motherboard USB Power Switch USB Device Power Switch Hot-Plug Power Supplies Battery-Charger Circuits DC+ VIN

ZigBee Compliant Platform 2.4G RF Low Power Transceiver Module for IEEE Standard. DATA SHEET Version B

Features. Applications. Regulator with Adjustable Output

C7110C1001A / C7110D1009A WALL MODULES

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

Trend-1 Vibration Data Logger. User Manual

MIC2027/2077. Features. General Description. Applications. Typical Application. Quad USB Power Distribution Switch

Transcription:

Product Specification Senseair LP8 Miniature CO 2 sensor module for battery-powered applications General LP8 is a miniature sensor module for battery-powered applications. It gives a full control on sensor integration into a host system, flexibility in changing of the CO 2 measurement, period and power consumption. One measurement requires 3.6mC of charge (or energy 11.9mJ at 3.3V battery supply). To minimise power consumption, the sensor should be turned OFF between measurements. 1 (8)

Item Senseair LP8 Article No. 00-0-0001, 00-0-0003 Target gas Carbon dioxide (CO 2 ) Operating Principle Non-dispersive infrared (NDIR) Operating environment range 0 0 C, 0 8%RH (non-condensing) Measurement range, calibrated Accuracy CO 2 0 2000ppm (extended range up to 10000ppm) 1, 2, 3 ±0ppm, ±3% of reading (extended range ±10% of reading) 1, 2, 3, 4 RMS noise CO 2 14ppm @ 400ppm, 2 C, 2ppm @ 1000ppm, 2 C Accuracy Temperature ±0.7 C Storage Temperature -40 70 C Power supply Peak current max 2.9.V unprotected against surges and reverse connection 140mA @ 0 C (typical 12mA @ 2 C) Leakage Shutdown current 1µA, 6 Charge per measurement 3.6mC (worst case) Energy per measurement 11.9mJ @ 3.3V (measurement period 16s) Current consumption 16second sampling 60second sampling Measurement period 22µA, 6 61µA, 6 (3.2mJ) 16s Measurement repeatability Response time T 90% 16 seconds sampling 60 seconds sampling Max. ±1% of specified CO 2 concentration, ±10ppm @ 1000ppm Filtered signal Non-filtered signal 4 minutes 7 minutes 3 minutes 10 minutes Dimensions 00-0-0001 (with pin headers) 00-0-0003 (no pin headers) Life expectancy 33.4 x 19.9 x 12.4mm (max dimensions L x W x H) 33.4 x 19.9 x 8.mm >1 years Storage temperature -40 70 C Weight <8g Serial communication Maintenance UART (host-slave protocol) Table 1. Key technical specification for the Senseair LP8 A host system counts ABC (Automatic Baseline Correction) period itself and has to write ABC command to the Calculation Control byte when ABC period (eight (8) days) expires. Note 1: Accuracy is met at 10 40 C, 0 60%RH, after minimum three (3) performed Automatic Baseline Corrections, preferably spanning eight (8) days in-between, or a successful zero-calibration. Note 2: Based on reading filtered CO2 measurement data in stable environments and in continuous operation by control mode Note 3: Accuracy specification is referred to calibration gas mixtures with additional uncertainty of ±1% Note 4: Extended range accuracy is not calibrated or guaranteed, it is extrapolated from calibrated range Note : Resistor network for measuring VCAP voltage adds 14µA @.V Note 6: External super-capacitor leakage is not considered 2 (8)

Installation and soldering See Senseair LP8 Handling manual (ANO1332). Sample gas diffusion area Diffusion area Figure 1. Diffusion area Mechanical properties See Senseair LP8 Handling manual (ANO1332). Pin assignment Bottom layer VCAP GND PWM RESET VBB EN_VBB RxD TxD RDY Figure 2. Pin assignment Pin # Name Type Maximum Voltage, V Description JP1 (4-pin header) 1 VCAP Power 6. Lamp driver supply voltage 2 GND Power - Ground 3 PWM Output 3.6 I/O pin. PWM output or other function can be assigned. 4 RESET Input 2. Reset. Pull-up resistor (10k) is connected to 2.V JP2 (-pin header) 1 VBB Power. Supply voltage 2 EN_VBB Input VBB Enable pin to activate voltage regulator. I Max = 2µA, in logic low state. 3 RxD Input 3.6 UART receive pin to sensor MCU from host 4 TxD Output 3.6 UART transmit pin from sensor MCU to host RDY Output 3.6 Signal is used to synchronise sensor with a host system. Table 2. Terminals and I/O options dedicated in Senseair LP8 model 3 (8)

Time diagram Figure 3. Time diagram Note 1: typical values for 9600 baud rate 4 (8)

Self-diagnostics All EEPROM updates are checked by subsequent memory read back and data comparisons. EEPROM consistency is checked by page checksum calculation. Electrical specification Parameter Min Typical Max Unit Test conditions Power supply voltage: VBB (electronics) 2.9. V VCAP (lamp) 2.9 6. V Peak current: VBB = VCAP = 2.9.V VBB (electronics) 1.4 6 ma T amb = 0 0 C VCAP (lamp) 2 VCAP (lamp) 2 Note 1: Charging of 20µF decoupling capacitance is not considered Note 2: Charging of 220nF decoupling capacitance is not considered Note 3: Peak-current decreases with increasing temperatures Note 4: Without pull-down resistor 100k on EN_VBB (as default, this is not mounted on LP8) Note : Currently not available as purchasable option Recommended host connection 119 129 134 ma ma T amb = 2 C T amb = 0 C 3 T amb = 2 C, VCAP =.V Total (VBB + VCAP) 12 140 ma Leakage shutdown current VBB (electronics) 4 1 2 µa T amb = 2 C VCAP (lamp) 00kΩ resistor network 12 14 µa T amb = 2 C, VCAP =.V VCAP (lamp) without voltage 0.1 0.2 µa T amb = 2 C, VCAP =.V monitoring Charge per measurement cycle T amb = 0 0 C, VBB = VCAP = 2.9.V VBB (electronics) 1.1 1.2 mc Baudrate: 9600 1.0 1.1 mc Baudrate: 19200 VCAP (lamp) 2.2 2.4 mc Table 3. Electrical specification Figure 4. Recommended host connection In some battery-powered systems, current limiter can be a simply Ω resistor. Suggested super-capacitor type is Eaton Bussman PM-R0H474-R (0.47F V). It is specified for 8µA leakage current @ V, 20 C and 00mΩ ESR. An external low-leakage switch (for example TPS22907) can be used to switch OFF both VCAP and VBB between measurements. VBB can be supplied from super-capacitor. (8)

Sensor control by a host MCU system Figure. Sensor control by a host MCU system Measurement period of the sensor is determined by customer host system and may vary without degrading measurement accuracy. Minimum allowed measurement period is 16 seconds (below 16 seconds, accuracy is not guaranteed). Calibration ABC: A host system counts ABC period itself and has to writes ABC command to the Calculation Control byte when ABC period (eight days) expires. The lowest CO 2 value (400ppm defines in this case as fresh air, included remembered accompanying parameters ) measured during the period from the last Initial state - / ABC - / Background - / Zero calibration writes to the Calculation Control byte. Background calibration: a) Using unfiltered channel, sensor considers current unfiltered measurement values to provide calibration. b) Using filtered channel, sensor considers filtered values to provide calibration (sensor has to be exposed for fresh air >40 lamp pulses/measurement periods). Zero calibration: a) Using unfiltered channel, sensor considers current unfiltered measurement values to provide calibration. b) Using filtered channel, sensor considers filtered values to provide calibration (sensor has to be exposed for zero gas >40 lamp pulses). The LP8 sensor works as a slave and totally acts on the host/master actions applied through the Calculation Control byte. Default position: slave- power OFF (requires sensor power OFF). Sensor power ON: the sensor can perform the next measurement. 6 (8)

Error code and action plan ErrorStatus0 byte description Bit Bit Name Error Description Suggested Action 0 Fatal Error Fatal Error The bit is a joint bit for different error sources when sensor cannot provide correct operation, among them: Configuration EEPROM parameters are out of range or corrupted Virtual EEPROM memory read/write error Error in VCAP measurements Switch OFF/ON sensor power and start with Initial Measurement in the Calculation Control byte. Contact local distributor. 2 AlgError Algorithm Error Configuration EEPROM parameters are out of range or corrupted 3 Calibration Calibration Calculation Error Out of range error at Zero-/Background calibration and ABC 4 SelfDiag Self-Diagnostics Error Hardware error is detected or important EEPROM parameters are corrupted OutOfRange Out Of Range Error (OOR) Indicates an error which occurs at different stages of concentration calculation algorithm. Resets automatically after source of error disappears. 6 Memory Memory Error Virtual EEPROM read/write error: page checksum error during read or write verification, FLASH operation error. 7 WarmUp WarmUp bit Bit is not set in customer mode Table 4. ErrorStatus0 byte description ErrorStatus1 byte description Repeat recalibration or wait until next ABC event. Contact local distributor. Try sensor in fresh air. Perform sensor zero or background calibration. Check sensor temperature readings. Contact local distributor. Bit Bit Name Error Description Suggested Action 0 VCAP1 low VCAP1 voltage low Voltage measured prior lamp pulse is below preset threshold. The threshold is 2.8V ±3%. Check battery. Sensor supply voltage is below specified operational limit of 2.9V. 1 VCAP2 low VCAP2 voltage low Average voltage measured at the beginning of lamp pulse (during inrush steps) is below preset threshold 2.7V ±3%. 2 ADC Error ADC Error MCU ADC out-of-range error has occurred. 3 Reserved 4-7 Parameters override bits Table ErrorStatus1 byte description These bits indicate which parameter is forced to a predefined value in the debug mode. Should not appear during normal operation. - ESR (Equivalent series resistance) of the sensor power supply source (a battery or super-capacitor) is not enough to provide low-voltage drop during 12mA lamp inrush step. Switch OFF/ON sensor power and apply initial measurement to the Calculation Control byte. Contact local distributor. Bits 3 0 of the ErrorStatus2- and ErrorStatus3 bytes decode on what algorithm stage an Out Of Range Error (OOR) has occurred in unfiltered- and filtered calculation channel respectively. - Maintenance Senseair LP8 has a built-in self-correcting ABC algorithm. ABC period is adjustable by host. Discuss your application with Senseair in order to get advice for a proper calibration strategy. 7 (8)

Senseair AB Europe Senseair North America Box 96 29030 SW Town Center Loop East Senseair Asia Senseair Chengdu Gas Sensors Ltd. Stationsgatan 12 Suite 202 #169 First floor of 8th of Xingke South Road SE- 82060 Delsbo Wilsonville, OR 97070 Jiniu Hi-Tech Industrial Park Sweden USA 610036, Chengdu China Phone: +46(0)63 71 77 70 Phone: +1 (20) 349-7686 Phone: +86-028 - 87 928 8 E-mail: info@senseair.com E-mail: infoamerica@senseair.com E-mail: info@senseair.asia Web site: senseair.com Web site: senseair.com Web site: senseair.asia 8 (8)